Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1020420603Wire · disconnectedWHITE EMERGENCY LIGHT AT SEAT 25D INOPERATIVE. HARNESS IS PULLED OUT. SPLICED AND SECURED WIRES UNDER SEAT 25D. OPS CHECK OK.SDR UALA2010082303088Pump · failedLEFT ENG HYD PUMP EICAS, FLT DIVERTED. FBO MECH FOUND HYD LEAK AT NR 1 ENGINE DRIVEN PUMP FLANGE. LT HYD RSVR WAS FOUND EMPTY. REPLACED NR 1 ENG HYD PUMP. RAN NR1 ENG FOR ENG DRIVEN HYD PUMP REPLACEMENT, OP CHECKED NR 1 ENG HYD IAW JRH. OP CHECKED GOOD.SDR UALA2012081304425Floorbeam · corrodedAFT CARGO BAY, BS 1380, RBL 10 TO 13, FLOORBEAM CORRODED. ACCOMPLISHED REPAIR PER EA PD57- 53-047 AND UAL EVA-80014.SDR UALA2010082303111O-Ring · leakingNR 5 FLT SPOILER ACTUATOR HAS A RUNNING LEAK AT OUTBOARD PLUG. ACTUATOR OUT OF STOCK SFO. STILL TRYING TO GET IPC BREAKDOWN OF ACTUATOR TO CHECK FOR POSSIBLE PLUG O-RING PACKING. ALSO LEFT HYD SYSTEM RESERVOIR WILL NEED SERVICING AT .87. REPLACED O-RING ON LESDR DALA1024580617Pressure Panel · corrodedCABIN AFT PRESSURE DECK CORRODED. INSTALLED REPAIR DOUBLER IAW SRM 51-40-02.SDR DALA1024640617Pressure Panel · corrodedCABIN SAFTEY PRESSURE DECK CORRODED AT STA 1680-1720 LBL 50. REPAIRED IAW SRM 51-60-51.SDR DALA1024730617Pressure Panel · corrodedMAIN CABIN PRESSURE DECK HAS AREAS OF CORROSION STA 1680-1685, BL0 - RBL54 ON TOP OF EXISTING DOUBLER. REMOVED AND REPLACED DOUBLER .SDR UALA2010082003072Power Supply · failedROW 18-26 ABC STOWBIN EMERGENCY LIGHTS DO NOT COME ON WHEN TESTED. REPLACED BATTERY POWER SUPPLY, M10818 AND BATTERY IAW MM. TESTS OK.SDR UALA2010082303104Relay · faultyFOUND GALLEY 4B BREAKER POPPED IN COCKPIT PRIOR TO ENG RUNS. RESET BREAKER AND IT WAS POPPED AGAIN AFTER RUNS COMPLETED. REPLACED CB C743 AND RELAY K10136. NO HELP. CB POPPING AFTER 10 SECONDS. SUSPECT M227 AFT GALLEY ELCU. REPLACED LT AFT GALLEY PWR ELESDR UALA2010082003062Pump · leakingLT HYD SYS LEAK, FLIGHT DIVERTED. FOUND HYDRAULIC FLUID LEAKING FROM NR 1 ENGINE DRIVEN HYD PUMP FLANGE. CARBON SEAL FROM HYD PUMP DRIVE NEEDS TO BE REPLACED. REPLACED SEAL. ENG 1 HYD PRESSURE AND CASE DRAIN FILTERS REMOVED FOR EDP REPLACEMENT AND FLUSH. INSTSDR UALA2010082003070Frame · corrodedAFT CARGO BAY, STA 1460, RBL 16 TO 20, FRAME IS CORRODED. REMOVED CORROSION FROM FRAME SM1460 RBC 16-20 ORIGINAL THICKNESS .063 MATERIAL REMOVED .0004 MATERIAL REMAINING .059, FOUND TO BE WITHIN LIMITS, REINSTALLED ATTACH FITTINGS OF TRANSITION PANEL.SDR DALA1020080680Wire · damagedDURING LAYOVER CHECK, MX FOUND THE ROW 29 & 30 EMERGENCY PATH LIGHTS INOPERATIVE. MX REPAIRED THE WIRING AT EACH LIGHT. OPS CHECK WAS GOOD.SDR UALA2010081803041Valve · out of toleranceTHE RT RECIRCULATION FAN IS PARTICULARLY LOUD ON THIS AIRPLANE. REF SERVICE TIP MM, ACCOMPLISHED STEP 6. TEST FAILED. REF STEPS 1 THRU 5 OF SERVICE TIP. ALREADY ACCOMPLISHED. ACCOMPLISHED DUCT CLEANING. DECIBEL READING WITHIN LIMITS. CFM 370 AND FPM 3357 WITHSDR UALA2010081703006Frame · corrodedAFT CARGO BAY, STA 1460, LBL 1 TO 9, FRAME IS CORRODED. MAJOR REPAIR ACCOMPLISHED: SMC005 ON NONROUTINE CARD 2217N00334 .SDR UALA2010081703013Connector · damagedIN-SEAT EMERGENCY LIGHT AT SEAT 23ABC INOP. RELAMPED, BUT NO HELP. FOUND PIN PUSHED BACK AND RESEATED PIN. OP CHECKED GOOD.SDR UALA2010081703014Lamp · inoperativeIN-SEAT EMERGENCY LIGHTS AT SEAT 15ABC INOP. RELAMPED AND OP CKD GOOD.SDR UALA2010081803040Bottle · reads lowSLIDE 3L BOTTLE PRESS INDICATOR IN THE RED. SLIDE READS LOW. REPLACED SLIDE ASSY.SDR UALA2010081602991Line · leakingL HYD SYS LOSS, RTFL. LT GEAR DOWN LOCK ACTUATOR PRESS FLEX LINE LEAKING. R & R LINE AFTER HYD SYS SERVICED, RAN SYS WITH LT ENG PUMP AND ELEC PUMP. RESTORED ALTERNATE FLAPS SWITCH TO NORMAL AND CYCLED FLAPS AND PRIMARY FLT CONTROLS SEVERAL TIMES. CLOSED ALSDR UALA2010081703003Slide · deployedDOOR 4R - DOOR SLIDE DEPLOYED. REPLACED DEPLOYED SLIDE WITH SERVICEABLE SLIDE ASSY.SDR UALA2010081602986Unknown · odorFLIGHT DECK REPORTS FUEL ODOR IN FLIGHT DECK AT GATE AFTER SHUTDOWN. RAN LT ENG. CHECKED FOR FUEL LEAKAGE AFTER SHUTDOWN AT DIFFUSER AND COMBUSTION SECTION. NO LEAKAGE NOTED AND NO SMOKE EVIDENT. REMAINING ODOR IS RESIDUAL. DEEMED OKAY FOR SERVICE.SDR DALA1024610617Stringer · corrodedSTR 29L CORRODED AT STA 1455. REPAIRED IAW PRI 484843-14 REVO.SDR UALA2010081602978Skin Panel · damagedFOUND ON ARRIVAL, RT WING NR 6 L/E SLAT UPPER PANEL HAS DAMAGE & DELAMINATION. HOLE DIMENSION IS APPROX 17 INCHES LONG BY 8 INCHES WIDE. AREA OF DELAMINATION IS APPROX 30 INCHES LONG BY 12 INCHES WIDE. INSTALLED NR 6 L/E SLAT & COMPLETED STEPS THRU 3F(12)(GSDR DALA1024590617Skin · dentedDENT IN FUSELAGE AT STA 364, S25R. CUT OUT DAMAGE AND INSTALLED DOUBLER IAW ER/A 485365-14.SDR DALA1019225503Skin · dentedDURING LINE INSP, FOUND FUSELAGE SKIN DENTED AT BS 620 FWD, OF DOOR L2 AT S16L. REPAIRED IAW ERA 484616-14, REV A.SDR DALA1019235503Stringer · damagedDURING LINE INSP, FOUND FUSELAGE STRINGER 16L DAMAGED AFT OF BS 620. REPAIRED IAW SRM 53-00-03 FIG 201, ERA 484616-14.SDR DALA1019265637Video Unit · odorDURING FLIGHT, CREW EXPERIENCED A CARBON-SMOLDER ODOR NEAR ROWS 1 & 2. VIDEO EQUIPMENT WAS SHUTOFF AND ODOR DISSIPATED. MX CHECKED SEVERAL CABIN SYS AND REPLACED THE VIDEO REPRODUCER AND CONTROL UNIT. OPS CHECK WAS GOOD.SDR UALA2010081302965Handle · separatedCAPTAIN'S SLIDING WINDOW HAND CRANK FELL OFF. NEEDS CLAMP UP BOLT ASSY. PN ABC7313. NHA TORQUE LIMITER 170-0030 ON ORDER. ACCOMPLISHED UA-EVA-74048.SDR DALA1019310668Wire Harness · damagedDURING LAYOVER CHECK, MX FOUND THE RED EMERGENCY PATH LIGHT AT 26D INOPERATIVE. MX REPLACED THE SEAT WIRE HARNESS. OPS CHECK WAS GOOD.SDR UALA2010081102907Actuator · faultySPAR VALVE EICAS AND L SPAR VALVE LT. WHEN ENG WAS FAILING, THE ENG VAL LIGHT WAS FLICKERING. REPLACED LT ENGINE SPAR VALVE ACTUATOR, OPS NORMAL.SDR UALA2010080902888Feeder Cable · disconnectedLT AISLE EMERGENCY LIGHTS BETWEEN SEAT ROW 15-22 ARE INOPERATIVE. TROUBLESHOT FOUND FEEDER WIRE ROW 17 WAS NOT CONNECTED. RECONNECTED IAW B757 MM. PERFORMED OPS CHECK IAW MM.SDR UALA2010080902889Light · inoperativeEMERGENCY LIGHTS INOP FROM ROW 16 TO ROW 22. REPAIRED EMERGENCY LIGHTS FROM ROW 16 TO ROW 22 IAW MM.SDR UALA2010080902891Nose Cowl · damagedACFT TAXIED INTO JETWAY DAMAGING LT ENGINE NOSE COWL. FOUND DAMAGE AT 12 O'CLOCK POS. DAMAGE 2 DENT ONE IS 12 IN WIDE X 8 IN LONG X 2 IN DP. THE OTHER IS 18 IN LONG X 4 IN WIDE X 1 IN DP. ENG 1 INLET L/E BEYOND ALLOWABLE DAMAGE LIMITS OF SRM. REPLACED INLSDR UALA2010080902900Control Module · faultySPOILER MSG. UPON ARRIVAL, FOUND SPOILER CONTROL MODULE 1L HAD MODULE FAULT LIGHT. REPLACED SPOILER CONTROL MODULE. TESTS NORMAL. ALSO PUT SPOILER CONTROL MODULE IN POSITION.SDR UALA2010080902883Skin · delaminatedLEFT OUTBOARD AFT FLAP DENTED AND POSSIBLE DELAMINATION. LOCATED INBOARD OF OUTBOARD CANOE NEAR TRAILING EDGE. REPAIRED AREA IAW SRM.SDR UALA2010080602863Cam · out of adjustDOOR 3R HANDLE MOVED OUT OF THE LOCKED POSITION ON LANDING UNCOMMANDED. EICAS R AFT DOOR. ADJUSTED UPPER AND LOWER LATCH CAMS IAW MM. INSPECTED LATCH ROLLER CRANK AND COCKING ROLLER CRANK LINKAGE. ALSO INSPECTED DOOR HANDLE MECHANISM. OPS CHECKS NORMAL.SDR UALA2010080502847Gcu · faultyON APPLICATION OF T/O POWER RT ENG TRIPPED OFF LINE WITH EICAS MSG. SAMC TEXT: CREW REPORTS THAT RT IDG FREQ FLUCTUATES BETWEEN 419 TO 420 HZ AND THEN GOES BLANK AT IDLE. REPLACED RT GEN CONTROL UNIT IAW MM. ALSO ADJ IDG FREQUENCY 5 TURNS CW EQUAL TO 15 HZ,SDR C8GA2010000015Eec · malfunctionedDURING TAKEOFF AT APPROX 700 FT A STATUS MESSAGES WAS DISPLAYED "PRIMARY (L) ENGINE CONTROL". THE ACFT RETURNED TO DEPARTUE, WHERE IT LANDED WITHOUT INCIDENT. POST FLIGHT INSP WAS PERFORMED. R & R THE NR 1 ENGINE EEC AND SWA. PERFORMED OPS CHECKS ALL CHECKSSDR UALA2010080402822Shutoff Valve · defectiveNR 2 ENG BLEED WILL NOT CLOSE WITH SWITCH IN OFF WHILE ENG RUNNING. SUSPECT BAD VALVE OUT OF STOCK. T-S PER FIM. REPLACED PRSOV PER MM AND RAN ENG FOR LEAK CHECKS, ALL INDICATIONS CHECK NORMAL.SDR UALA2010080602866Charger · faultyMAIN BATTERY CHARGER EICAS. REPLACED MAIN BATTERY CHARGER AND TIGHTENED BATTERY TERMINALS, OPS CHECKS OK.SDR UALA2010080602867Battery · faultyMAIN BATTERY CHARGER STATUS REAPPEARED AFTER 2 HRS OF FLT. REPLACED MAIN SHIP BATTERY AND OPERATION CHECKS GOOD IAW MM.SDR UALA2010080402818Exciter · failedATTEMPTED TWO STARTS OF APU, NO LIGHT OFF AND FAULT LIGHT DISPLAYED. REPLACED EXCITER BOX. FL 340 APU RUNS NORMAL. CREW CONFIRMED APU OPERATED NORMAL.SDR UALA2010080402820Skin · delaminatedNR 1 ENG INLET COWL 12:00 TO 3:00 FROM L/E TO T/E HAS OUTER SKIN DELAMINATION APPROX 3FT BY 6FT. REPLACED NOSE COWL.SDR UALA2010080402821Shutoff Valve · faultyAPU BLEED VALVE OPENING AND CLOSING ON GND WITH R ENG BLEED CYCLING ON OFF WITH ENG SHUTDOWN. DUPLICATED PROBLEM. ISOLATED TO RT PRSOV. REPLACED PRSOV AND NO APU BLEED CYCLING NOTED.SDR UALA2010080402815Stowage Box · leakingTHE O2 SYS NOT HOLDING PRESSURE. FOUND CAPTAINS O2 MASK STOWAGE BOX LEAKING AT B-NUT CONNECTION. REPLACED STOWAGE BOX PER MM. SERVICED O2 TO FULL.SDR UALA2010080402819Warning System · malfunctionedEICAS SHOWS L ELEV PCU MSG. MSG ERASED, BUT RETURNS. TROUBLESHOT PER FIM MM. OPS CHECKED IT SEVERAL TIMES, UNABLE TO DUPLICATE MSG. REPLACED PCU MONITOR MODULE M10481 FOR PRECAUTION, OPS CHECKED GOOD.SDR UALA2010080202757Rotary Actuator · malfunctionedL/E SLAT DISAGREE MSG, RTFL. FOUND NR11 L/E ROTARY ACTUATOR OVERLOAD SPRING POPPED. ACTUATOR IS LOOSE AT MOUNTING FLANGE. REPLACED NR 11 L/E ROTARY ACTUATOR. OPS CKS NORMAL. NO MESSAGES NOTED.SDR UALA2010080202758Idg · failedEICAS MSG L GEN DRIVE DISPLAYED. GEN DRIVE LGT ILLUM. GEN DRIVE DISCONNECTED. IDG FOUND FAULTY. REPLACED THE IDG. OPS ARE GOOD. UNIT HAD NO PREVIOUS HISTORY.SDR UALA2010080202780Exciter · faultyAPU FAULT ON START DURING TAXI IN. APU BITE INDICATES FAULTY IGNITION UNIT. NO TIME TO FURTHER TROUBLESHOOT. REPLACED IGNITER, CABLE AND BOX PER MM'S, OPS OKAY.SDR ABXR2010073000029Structure · crackedDURING A HEAVY MX INSP EVENT THE LT AILERON LOWER T/E WAS FOUND CRACKED AND GOUGED BETWEEN THE PCA'S. REPAIRED DAMAGE WITH A COMPOSITE LAY UP. ITEM WAS RETURNED TO SERVICE.SDR UALA2010080202786Fuse · faultyEMERGENCY LIGHT AT L568, BS 1368, WL 180 AND LBL 62 IS INOPERATIVE. REMOVED AND REPLACED FUSE ON EMERGENCY POWER SUPPLY. OPS CHECK GOOD ON NON ROUTINE 2198N00023.
Back to Pratt & Whitney PW2037