Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1018970662Sill · corrodedAFT CARGO DOOR SILL UPPER CHORD CORRODED ON INTERIOR SIDE LOWER SURFACE AT NUTPLATES STA 1380-1420/ REPLACED AFT CARGO DOOR SILL AT SAA DURING HMV ON N/R CARD 166656.SDR DALA1019080662Pan · corrodedFWD CARGO LAV SERVICE PAN UPPER AND INBD DOUBLERS CORRODED STA 700-720 BETWEEN STRINGERS 20 & 22R. R & R LAV PAN DOUBLERS AT SAA SAT ON NON ROUTINE CARD 166673.SDR DALA1020230662Skin · corrodedAFT FUSELAGE ACCESS DOOR 313AL OUTER SKIN AND INNER AREA HAS CORROSION RL012 / REPLACED AFT FUSELAGE DOOR AT SAA.SDR DALA1020240662Gate · corrodedR2 DOOR LOWER GATE BOTTOM EDGE HAS PITTING. R & R NEW LOWER GATE ASSEMBLY AT SAA.SDR UALA2010062302228Charger · inoperative1 RH MED EMER EXIT LIGHT SIGN, OVER DOOR IS INOP. REPLACED BATTERY CHARGER AND BATTERY FOR EMER. LIGHT ASSY, OPS CHECKED NORMAL.SDR UALA2010062302229Switch · faultySQUIB TEST PANEL TEST SWITCH 2 DIFFICULT TO OPERATE. R&R TEST PANEL. REMOVED AND REPLACED TEST PANEL. REPLACED NR 2 TEST SWITCH. TESTS OKAY.SDR DALA1019040662Intercostal · corrodedAFT CARGO INTERCOSTAL LOWER LEG CORRODED STA 1420-1440 BETWEEN STR 28 & 29L. R & R INTERCOSTAL DURING HMVAT ST AEROSPACE SAT ON NON ROUTINE 164231.SDR UALA2010062302224Engine · overtempNR 2 ENG OVERTEMP DISPLAY, FLIGHT DIVERTED. OBTAINED EXCEEDANCE REPORT MAX TEMP 654, 640-32 SEC, 615-32SEC. DEN TEMP AT T-O 90DEG. INSPECTED NR 2 INLET & EXHAUST, NO DAMAGE FOUND. ACFT RELEASED BACK TO SERVICE WITH ENGINE ACCIDENCES CHECKED, ENGINE INSPECTEDSDR UALA2010062402254Line · damagedLT DUCT PRESS FLUCTUATES BY 20 TO 30 PSI DURING DESCENT. THROTTLES IDLE. REPLACED HI-STG VLV STILL FLUCTUATES 10-14 PSI. NEED FURTHER TROUBLESHOOTING. NEEDS NEW SUPPLY PRESS HOSE ASSY, B-NUT THREADS DAMAGED. REPLACED LINE, NO HELP. REPLACED HIGH STAGE VALVE,SDR UALA2010062102159Spoiler Sys · faultySPOILER MESSAGE AND EXCESSIVE RUDDER TRIM. 6 UNITS RT RUDDER TRIM REQ IN CLB-4 UNITS IN CRZ TO KEEP A-C LVL IN ROLL CONTINUED, 0 UNITS OF RUDDER PRODUCES PRONOUNCED LEFT ROLL RATE. NEGATIVE ROLL STABILITY. CHECKED RUDDER CHANGER RIGGING, YAW DAMPER SUMMING LSDR UALA2010062102174Light · inoperativeEMERGENCY LIGHT STRIP NEXT TO AFT FWD LAV IS INOP. REPLACED EMERGENCY LIGHT STRIP. OPS CHECKED GOOD.SDR UALA2010062102175Light · inoperativeEMERGENCY LIGHT STRIP JUST AFT OF 2L ENTRY DOOR IS INOP. REPLACED DAMAGED EMERGENCY LIGHT STRIP. OPS CHECKED GOOD.SDR UALA2010062202192Bulb · out of adjustL1 DOOR EXTERIOR EVACUATION LIGHT INOPERATIVE. OP CKS GOOD, ADJUSTED BULB.SDR UALA2010062202208Stowage Box · defectiveCAPT O2 MASK STORAGE BOX TEST SW STIFF TO OPERATE. REPLACED OXYGEN STORAGE BOX. LEAK CHECKED FITTING. NO LEAKS NOTED.SDR UALA2010062102181Lever · binding4R ARM LEVER BINDS. DISCONNECTED LOWER PUSHROD "D", NO HELP. DISCONNECTED PUSHROD "A" TO TRIGGER PIN MECH. NO HELP. DISCONNECTED PUSHROD "C" BINDING STOPPED. ISOLATED BINDING TO TORQUE SHAFT. FOUND ALL PUSH RODS RECONNECTED. CLEANED AND LUBED PUSHRODS AND LINSDR UALA2010062102164Wire · openGALLEY CHILLER INOP AT R1 DOOR GALLEY G1B. C/B C3023 ON P37 PANEL WAS TRIPPED. C/B RESET BUT WOULD TRIP AFTER APROX 10 SEC. WITH C.B FOR CHILLER ON FWD GALLEY SW PANEL OPEN, C3023 STAYS IN. RANG OUT WIRES FROM CHILLER TO C/B YS8C001, NO DISCREPANCIES NOTED. WSDR UALA2012061103197Skin · dentedFUSELAGE SKIN PANEL APPROXIMATELY 3 TO 4 FT AFT OF FWD CARGO DOOR IS DENTED AT BS 675, APPROXIMATELY 1 INCH ABOVE STR 23R. CUT OUT DENT DAMAGE AND FABRICATED AND INSTALLED A REPAIR DOUBLER IAW SRM 53-00-01.SDR DALA1013476711A/C Pack · odorAFTER T/O DETECTED SMOKE ODOR. TURNED OFF LT PACK ODOR PRECAUTIONARY TURNED OFF LT PACK. ODOR DISSIPATED AFTER PACK OFF. T/S IAW FIM 71-05-00-101. NO TROUBLE FOUND. PERFORMED TASK 21-00-01-002-001 AS PRECAUTION. BOTH ENG OIL FULL NO LEAKS NOTED. ALL HYD QUANSDR UALA2010062102167Wire Harness · faultedFUEL QTY IND EICAS. FLIGHT DIVERTED. REPLACED NR 4 CTR TANK FUEL PROBE & FILL VALVE. HIT AGAIN 1ST FLT. REMOVED BULKHEAD PANELS INSIDE CTR TANK 3EA, REPLACE SECTION OF HARNESS FOR NR 1 PROBE, REINSTALLED BULKHEAD PANELS. REPLACED LT CTR TANK HARNESS IAW MM. SDR UALA2010062102183Skin · damagedFUSELAGE DAMAGE TO SKIN APPROX STA 617 TO 677 AT WL 208 TEAR APPROX 9 IN LONG. MAJOR REPAIR ACCOMPLISHED: INSTALLED SKIN AT STA 630 AND STRINGER 17L TO 19L IAW UA-EVA-73889. PWI 6951 AND EA PD57-53-041. REPAIR IS A CATEGORY "C" INTERIM REPAIR AND MUST BE REPLSDR UALA2010061802153Regulator · faultyL ENG BLEED ON DURING CLIMB. REPLACED PRSOV. REPLACED REGULATOR & REPLACED HIGH STAGE PILOT (P/N 3399004-6U2 SERIAL 86). OPS CHECK WITH ENGINE RUN AND 3 MIN HIGH PWR IDLE RUN. NO FAULTS NOTED.SDR UALA2010061702133Duct · damagedHOT AIR BLOWING IN CABIN AT ROWS 11-14, OKAY ELSEWHERE. POSSIBLE LEAK IN DUCT WORK. DUCTS REPAIRED SFOOV, LEAK CHECK GOOD.SDR UALA2010061702137Indicator · faultySPLIT FLAPS IND, RTFL. REPLACED FLAP INDICATOR. INDICATION CHECKS WITHIN TOLERANCE BANDS AT ALL STOPS UP AND DOWN. VISUAL CHECK OF LEFT TRANSMITTER AND LINKAGE LOOKS OK. VISUAL OF FLAPS AND SLATS DURING MOVEMENT CHECKS GOOD.SDR UALA2010061502103Light · damagedLIGHT STRIP ON FLOOR NEXT TO FWD AFT LAV HAS TAPE COMING OUT OF IT. INTERM REPAIR ACP USING 3M CLEAR TAPE 8686. WILL REQUIRE A NEW END CAP. LIGHTS WORK CORRECTLY AND NO PART IS OBSTRUCTED FROM VIEW. REPLACED MISSING END CAP, OPS CHECKED GOOD.SDR DALA1014340602Skin · bulgedSKIN BULGING FS 1720 S29R. REPAIRED AREA IAW ERA 483346-14 REV A.SDR UALA2010061502105Skin · delaminatedNR 2 ENG OUTBOARD THRUST REVERSER UPPER BIFURCATION PANEL INNER SKIN AND OUTER SKIN BOTH 90 PERCENT DELAMINATED. DELAM EXCEEDS 600 SQUARE IN AND IS BEYOND LIMITS TO TEMP REPAIR. REQUIRES FERRY FLIGHT TO REPAIR. REPLACED NR 2 ENG OUTBOARD THRUST REVERSER.SDR DALA1012775528Skin · damagedDURING LIGHTNING STRIKE INSP, FOUND DAMAGE TO FUSELAGE SKIN AT BS 593 APPROX 2.5 INCHES ABOVE S3L. REPAIRED IAW SRM 53-00-01, FIG 201.SDR DALA1012795528Skin · damagedDURING LIGHTNING STRIKE INSPECTION, FOUND DAMAGE TO FUSELAGE SKIN AT BS 565 APPROX 1.5 INCHES ABOVE S3L. REPAIRED IAW SRM 53-00-01 FIG 201.SDR UALA2010061402091Floorboard · weakROW 28, AISLE FLOOR VERY WEAK AND SPONGY. INSTALLED DOUBLER. 5B PANEL TO BE REPLACED NEXT C-CHECK.SDR UALA2010061402062Light · out of adjustL4 DOOR EXIT EVAC LIGHT INOP. ADJUSTED LIGHT ASSY OP CK GOOD.SDR DALA1013070665Light · inoperativeDURING LAYOVER CHECK, MX FOUND THE ROW 40 EMERGENCY PATH LIGHT INOPERATIVE. MX REPLACED THE LIGHT ASSY. OPS CHECK WAS GOOD. (DL757101500)SDR UALA2010061102040Lamp · inoperativeNR 2 ENGINE FIRE HANDLE LIGHTS INOP DURING FIRE TEST, (LIGHTS INSIDE FIRE HANDLE NOT LIGHTING UP). RELAMPED NR 2 ENGINE FIRE HANDLE, OPERATIONS CHECKED NORMAL IAW MM OPS TEST.SDR DALA1013030631Wire · damagedDURING LAYOVER CHECK, MX FOUND SEAT 6C AND 23D EMERGENCY PATH LIGHTS INOPERATIVE. MX REPAIRED THE WIRING. OPS CHECK WAS GOOD. (DL757101486)SDR UALA2010060902008Charger · failedSLIDE EMERGENCY LIGHT AT DOOR 2 LEFT DOES NOT ILLUMINATE. REPLACED POWER SUPPLY AND BATTERY PACK AT POSITION M733. WORKS NORMALLYSDR UALA2010060902015Girt Bar · obstructedARM-DISARM LEVER ON 3R IS STUCK. REMOVED DEBRIS FROM THE AFT AREA OF THE GIRT BAR.CHECKS OKAY.SDR UALA2010060801995Cable · stuckUNABLE TO ARM DOOR 2L. REMOVED STUCK CABLE. INSPECTED SLIDE INSTALL, OKAY.SDR UALA2010060701983Elevator · damagedLEFT ELEVATOR LWR SURFACE DAMAGED. PUNCTURE DAMAGE MEASURES .75 X .5" LOCATED 83" FROM INBD EDGE OF ELEVATOR AND 15" AFT OF LEADING EDGE. APPLIED INTERIM REPAIR. TAPE APPLIED TO DAMAGED AREA. MUST HAVE PERMANENT REPAIR WITHIN 300 FLT HRS. PER SHOP, DAMAGE IS TSDR DALA1012245520Battery Pack · inoperativeOVERHEAD EMERGENCY EXIT SIGN FWD OF LAV D INOPERATIVE. REPLACED POWER SUPPLY AND BATTERY AT DOOR 3R IAW AMM. OPS CHECK OK.SDR UALA2010060701971Control Cable · misroutedFLIGHT CONTROLS STIFF IN PITCH AND ROLL ON GROUND AND IN AIR. HEAVY CONTROLS FELT ON BOTH CONTROL COLUMNS, AP'S DISENGAGED, HYD'S PRESS AND QTY'S NORMAL. CHECKED LT AND RIGHT AILERON PCU. COMPLETED SYSTEM TEST. SYSTEM WILL INCREASE WHEEL FORCE. HAD TO FLY APPSDR DALA1013220689Wire · damagedDURING LAYOVER CHECK, MX FOUND EMERGENCY PATH LIGHTS NEAR DOOR R1 INOPERATIVE. MX REPAIRED THE WIRING. OPS CHECK WAS GOOD. (DL757101448)SDR UALA2010060701989Lanyard · out of positionDOOR 2L SLIDE WILL NOT ARM. CORD LINE OUT OF POSITION, ADJUSTED. OPS CKS NORMAL.SDR DALA1012235650Wire · disconnectedEMERGENCY LIGHT AT SEAT 6B WILL NOT ILLUMINATE. FOUND WIRE DISCONNECTED AT CONNECTOR. REPLACED SEAT-MOUNTED LIGHT ASSY. OPS CHECKED OK.SDR DALA1013240604Skin · corrodedOUTER FUSELAGE SKIN CORROSION OF AFT LAV PAN. REPAIRED AREA IAW ERA 483097-14, REV A, TIME LIMITED REPAIR.SDR DALA1012125635Oven · odorDURING FLIGHT, CREW FOUND FWD GALLEY OVENS EMITTED AN ELECTRICAL FIRE ODOR. CREW PULLED THE OVEN CIRCUIT BREAKERS AND THE ODOR SUBSIDED. MX FOUND THE TRIPLE OVEN WITH A BURNED ODOR AND REPLACED SAME. OPS CHECK WAS GOOD.SDR DALA1012130643Light · inoperativeDURING LAYOVER CHECK, MX FOUND EMERGENCY PATH LIGHTS ROW 27 TO 37 INOPERATIVE. MX REPAIRED WIRES AT SEAT ROW 27DEF. OPS CHECK WAS GOOD.SDR DALAFAR145SDR101Slide · no testDURING A SCHEDULED C-8 VISIT, AN INTENTIONAL SLIDE DEPLOYMENT WAS SCHEDULED. THE SLIDE AT THE L-3 DOOR FAILED TO INFLATE AUTOMATICALLY WITH THE OPENING OF THE DOOR. HOWEVER ONCE THE MANUAL HANDLE WAS PULLED, THE SLIDE INFLATED PROPERLY.SDR UALA2010060301923Lanyard · dislodgedDOOR 3L HAS ESCAPE ROPE HANGING OUT NEEDS TO BE RESECURED. REINSTALLED GIRT BAR LANYARD & BUSTLE. ACCMP'D RII ON 4 LT LANYARD REPOSITIONING.SDR UALA2010060101858Structure · damagedACFT DAMAGE LT ELEVATOR T/E HAS (2) EACH LOCATIONS DAMAGED FROM CONTACT WITH LIFT DURING MX. REPLACED LT ELEVATOR.SDR UALA2010052801838Control Panel · faultyAUTO TILT ON WX RADAR NOT PAINTING GROUND RETURN POINTING TOO HIGH. MANUAL TILT ALSO SEEMS OFF. REPLACED THE WX RADAR CONTROL PANEL. ACCMP'D FLIGHT DECK SELF TEST, TESTED OK.SDR UALA2010052801842Relay · faultedBEFORE DISPATCH SEVERAL STATUS MESSAGES APPEARED ON EICAS-MAIN BATTERY CHARGER, EXH NR1 AFT EQUIP WITH FLUCTUATION OF CTR HYD QTY. COMMON 115 VOLT AC FOR ABOVE SYS IS A2 PHASE OF 115V AC GROUND SVC BUSS. WD 24-51-52. FOUND TWO LUGS ON GROUND SERVICE TRANSFE
Back to Pratt & Whitney PW2037