Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010070902442Stowage Box · faultyABNORMAL OXYGEN REGULATOR OPERATION AT POSITION 2. (1=CAPT, 2=1ST OFF, 3=1ST OBS). REMOVED AND REPLACED F/O CREW OXYGEN MASK STOWAGE BOX. OPERATIONAL CHECK OKAY.SDR UALA2010070902445Pump · faultyAC MOTOR PUMP - WITH LOW PRESS LIGHT ILLUMINATED AND EICAS MESSAGE 'R HYD ELEC PUMP' DISPLAYED AND EICAS MESSAGE 'HYD SYS MAINT' WAS NOT DISPLAYED. CREW COMMENTS: PRESS LIGHT ALSO ON W-EICAS MSG. NOTICEABLE BUMP IN YOKE WHEN LIGHT GOES OUT. REPLACED RT ACMSDR UALA2010071202480Skin · delaminatedLEFT I/B FLAP ASSY, AFT FLAP LWR SURFACE HAS 3 EACH AREAS OF DELAM AT I/B MOST 30 INCHES. ACP'D ON DOCK WU T6483X. RII INSP ACP'D. REPLACED LEFT INBOARD AFT FLAP.SDR UALA2010071202479Skin · damagedAPPROX 4 DROPS PER SEC DRIPPING FROM I/B TRAILING EDGE FLAP I/B END & SEVERAL AREAS OF DELAMINATION AT LOWER SURFACE. ACCOMPLISHED ON DOCK WU W4611N. REPLACED AFT FLAP PER MM.SDR UALA2010070902443Terminal · looseR1 WINDSHIELD NEED TO BE CHANGED DUE TO J1 TERM FOUND LOOSE. REPLACED WINDSHIELD PER MM, OPS OKAY.SDR UALA2010070902450Cover · unsecureRT OVERWING EXIT SLIDE COVER NEEDS TO BE RE-SECURED. REMOVED AND REPLACED RT OVERWING EXIT SLIDE.SDR UALA2010070602404Switch · faultedAPU FAULT ON START. APU FAULT ON START. ECU BOX SHOWS LOP FAULT. CLEARED MSG, ATTEMPT TO START APU, FAULTS AT 89 PERCENT AND SHUTS DOWN. BITE FAULTS 'LOP'. ON START APU COMES UP TO APPROX 90 PERCENT THEN SHUTS DOWN. FAULT LIGHT AND "LOP" ON BITE. NO SWISDR UALA2010070602414Circuit Card · defectiveWEU TEST FAILED WITH WARN ELEX 'B' CB CLOSED AND 'A' CB OPEN. REPLACED CARD M983, NO HELP. TRIED NEW POWER SUPPLY, NO HELP. NEEDS MORE TROUBLESHOOTING. REPLACED CARD M983, TESTS OKAY.SDR UALA2010070602366Compressor Blade · damagedL ENG STALL/SURGE, FLIGHT DIVERTED. HPC STAGES 6 THROUGH 17 BLADES DAMAGED BEYOND LIMITS. ENGINE REMOVED.SDR UALA2010070602395Guard · looseEMERGENCY LIGHT TEST COVER IS LOOSE AT DOOR 2L. SECURED LOOSE EMERGENCY LIGHT SWITCH GUARD AT DOOR 2L.SDR UALA2010070602413Eec · faultyRT ENG SEC CONT STATUS MSG. CREW SHUTDOWN ENG PER SAM & CLEARED FAULT. MSG RETURNED AFTER ENG RESTART. EPCS MSGS 275-16. NOTES EEC, S275-25 AND S275-16 MESSAGES RECORDED ON EPCS PAGE. REPLACED R ENG EEC PER MM, OPS CHECK OK PER MM, RAN ENG PER JRH. REPLASDR UALA2010070802430Windshield · damagedLOWER EDGE OF CAPTS WINDSHIELD SHOWS POSSIBLE SIGNS OF OVERHEATING. NR 1L WINDSHIELD HAS TOTAL 9 INCHES OF UNEVEN BROWNING ALONG THE BOTTOM EDGE, 1-8 TO 3-8 WIDE, WITH SMALL MOISTURE DELAMINATION. NEED TO REPLACE WINDOW WITHIN 150 FLIGHT HOURS. REPLACED WINSDR IPXA10561149Skin · dentedINSPECTION TYPE:C4, LT HORIZONTAL STAB EXTERNAL UPPER SKIN SURFACE IS DENTED 67 INCHES FROM INBD, 4 INCHES AFT OF AUX SPAR. AREA FOUND TO BE OUT OF LIMITS ON CUSTOMER CARD 879126 DUE TO AREA OF DENT IS LARGER THAN 1.5 SQ IN. REPAIRED IAW SRM 51-70-01.SDR UALA2010070602409Actuator · leakingRUNNING HYDRAULIC LEAK LT WING AT DEPT. FLUID STREAMING OUT OF INBOARD FLAP CANOE. SUSPECT NR 5 SPOILER ACTUATOR IS LEAKING. REPLACED NR 5 SPOILER ACTUATOR PER AMM. ADJUSTED PER AMM. OPS CHECK AND LEAK CHECK GOOD.SDR DALA1015966814Engine · bird ingestionNR 2 ENGINE HAD BIRD STRIKE FOLLOWED BY VIBS - DIVERTED TO MAD PERFORMED BIRD STRIKE INSPECTION PER 05-51-18 AMM AIRCRAFT FUSELAGE NO DEFECTS NOTED RT ENGINE SHOWS DAMAGE ON FAN BLADES AND ACOUSTIC LINER (DL75E101749).SDR UALA2010070602405Circuit Card · defectiveLEFT ENG BLEED VALVE OFF LIGHT ON WITH POWER AT IDLE IN DESCENT. RESET PER CHECKLIST OK. REPLACED LT ENG N2 SPEED CARD. RAN ENG ALL PRESSURES AND INDICATIONS NORMAL.SDR UALA2010070602378Strap · faultyNR 1 LT PAX ENTRY DOOR EVAC SLIDE - V - STRAP HARNESS LWR METAL -U- CHANNEL NOT PROPERLY SECURED TO GIRT MOUNT BRACKET. U - CHANNEL MOUNT HOLE AT FWD END NOT SECURED THROUGH BRACKET PIN. REPLACED STRAP ASSY AND SECURED SLIDE.SDR DALA1020200662Bulkhead · chafedAFTER REMOVAL OF NR 2 PYLON AFT BULKHEAD NAC STA 201 FOUND INBD SIDE LOWER CORNER CHAFED.SDR UALA2010070202364Windshield · damagedCAPTAINS WINDSHIELD HAS SEVERAL BURN SPOTS ON LOWER EDGE. CAPTAIN'S WINDSHIELD HAS SEVERAL BURN SPOTS ON LOWER EDGE. REMOVED CAPTAINS WINDSHIELD AND HAVE NEW WINDSHIELD IN PLACE WITH INITIAL TORQUE ACP'D AT 1900 HRS. NEED TO COMPLETE WINDSHIELD INSTALLATIONSDR UALA2010070602403Charger · faultyAPU NO START 2 ATTEMPTS EGT 780 - RPM 20 PERCENT. STARTED APU, NOTED APU BAT VOLTS WENT TO 14 DURING START. SUGGEST REPLACING APU BAT AND CHARGER. BIT APU CONTROLLER, GOT LOP FAULT--LOW OIL PRESS. FOUND OIL QTY LOW--ADDED 1QT. APU STARTED NORMALLY.SDR UALA2010070102349Connector · misinstalledNR1 HF WEAK AND SCRATCHY IN REC-XMIT UNABLE TO USE. NEEDS MORE TIME. REPLACED HF-L ANTENNA COUPLER, NO HELP. TDR CHECK OF ANTENNA CABLES FROM E & E TO ANTENNA CHECKS GOOD. CHECKED CONNECTIONS IN COUPLER AND ANTENNA AREA. REPLACED LT AND RT HF COAX CABLSDR UALA2010070202356Cap · missingTWO HIGH VOLTAGE CAPS MISSING FROM COPILOT'S SLIDING WINDOW (HEAT TERMINALS). INSTALLED TAPE PER UA-EVA. CAPS TO BE REPLACED WITHIN 100 HOURS.SDR UALA2010063002333Monitor · sparksPAX REPORT SAW SPARKS IN OVERHEAD MONITOR AT ROW 27. MAINT REPLACE OR DEACTIVATE MONITOR BEFORE FLIGHT AND APPLY MEL 2520GY. PLACED DEFERRAL PER SAM-C FOR PRECAUTIONARY MEASURE FOR MONITOR REPLACEMENT. REF MEL 2520GY. REMOVED CONNECTOR FROM MONITOR AT ROW SDR DALA1019980662Frame · damagedAFTER SKIN REMOVAL ON NR2 PYLON OTBD SIDE RT FOUND 1 EA OVERSIZE HOLE FWD FRAME LWR HOLE AT STA 108. COMPLIED WITH ER/A 483519-14 REV ORIG AT SAA. DURING HMV ON N/R CARD 169569.SDR DALA1020220662Skin · damagedAFTER REMOVAL OF LT SKIN ON NR2 PYLON, FOUND DAMAGED HOLE AT STA 114 UPPER CHORD AREA.SDR UALA2010062802290Skin · damagedLT AFT OVERWING EXIT DOOR HAS A HOLE IN OUTER SKIN. MAJOR REPAIR ACCOMPLISH: REPAIRED HOLE IN OVERWING EXIT DOOR, FABRICATED A REPAIR DOUBLER, FILLER AND SHIM.SDR UALA2010062802293Lamp · inoperativeEXTERIOR EVACUATION LIGHT INOPERATIVE AT R1 DOOR. RELAMPED.SDR UALA2010062802299Actuator · malfunctionedFOUND APU DOOR MESSAGE ON EICAS. APU INLET DOOR CIRCUIT BREAKER POPPED, RESET CIRCUIT BREAKER, NO HELP POPPED AGAIN. OPEN APU DOOR. PER MEL. REPLACED INLET DOOR ACTUATOR.SDR DALA1019110662Skin · dentedFUSELAGE EXTERNAL SKIN HAS A DENT STA 606 AND S-17L, COMPLIED WITH ER/A NR484136-14 REV ORIGINAL AT SAA SAT ON NON ROUTINE 169561.SDR DALA1019990662Skin · dented3 DENTS ON LWR FUSELAGE SKIN EXTERIOR SURFACE BETWEEN S28R AND S29L AT STA 1394, 1395, AND 1396 AND SEVERAL SCRATCHES ON DENTED AREA. ACCOMPLISHED ER/A 484128-14 AT SAA DURING HMV ON N/R CARD 169560.SDR DALA1020210662Skin · dentedDENT ON FUSELAGE SKIN EXTERIOR SURFACE AT STA 662 BELOW LAP JOINT S19R.SDR ABXR201006272010Flap Track · corrodedDURING MX, THE LEFT OTBD FLAP, OTBD TRACK WAS BLEEDING RUST. UPON DISASSEMBLY, THE TRACK WAS FOUNDED CORRODED. THE CORROSION WENT BEYOND THE CMM LIMITS. MFG ENGINEERING ISSUED AN REA TO FURTHER CLEAN THE CORROSION WITH ADDITIONAL LIMITS ESTABLISHED. THE CORROSDR UALA2010062802288Battery Pack · faultyFOUND BATTERY PACK FOR EGRESS LIGHTING NOT WORKING FWD OF AFT LAV DOOR. REPLACED EGRESS LIGHTING, BATTERY PACK. OK FOR SERVICE.SDR UALA2010062802289Reservoir · reads lowR1 DOOR EMERGENCY POWER RESERVOIR READS NO PRESSURE. REMOVED AND REPLACED R1 DOOR EMERGENCY POWER RESERVOIR.SDR ABXR201006270012Floor Support · corrodedDURING A MX, CORROSION WAS FOUND ON A FLOOR SUPPORT ANGLE AT FS 780 LBL 6. THE CORROSION WAS FOUND BEYOND LIMITS. FABRICATED A NEW SUPPORT ANGLE FROM 7075-0, 0.063". HEAT TREATED ANGLED. CORROSION TREATED ANGLE AND REINSTALLED. ITEM RETURNED TO SERVICE.SDR ABXR201006270013Floor Support · corrodedDURING A MAINTENANCE INSPECTION EVENT, CORROSION WAS FOUND ON A FLOOR SUPPORT ANGLE AT FS 780 BL0. THE CORROSION WAS FOUND BEYOND LIMITS. FABRICATED A NEW SUPPORT ANGLE FROM 7075-0, 0.063". HEAT TREATED ANGLED. CORROSION TREATED ANGLE AND REINSTALLED. ITEM RETSDR ABXR201006270014Frame · corrodedDURING MX, CORROSION WAS FOUND ON THE FLC AFT BULKHEAD LOWER CTR FRAME. CUTOUT CORROSION DAMAGE AND REPAIRED DAMAGE IAW THE SRM USING 7075 T6 0.050" AND 7075-T6 0.063". ITEM RETURNED TO SERVICE.SDR ABXR201006270016Support Fitting · corrodedDURING MX, CORROSION WAS FOUND ON A SEAT TRACK SUPPORT FITTING (CHORD). CORROSION WAS FOUND OUT OF SRM LIMITS. ISSUED WITH GREATER CLEANUP ALLOWED. ITEM RETURNED TO SERVICE.SDR ABXR201006270017Floorbeam · crackedDURING MX, A FLOOR SUPPORT LBL 46-LBL 62 BS 1060 FOUND CRACKED. ISSUED FOR FABRICATION INSTRUCTIONS. FABRICATED THE CRACKED FLOOR SUPPORT/INTERCOSTAL FROM 7075-0 0.050" HAND HEAT TREATED. REINSTALLED INTERCOSTAL AND ITEM RETURNED TO SERVICE.SDR ABXR201006270018Frame · corrodedDURING MX, THE LT WING AILERON WAS FOUND DELAMINATED. REMOVED CONDUCTIVE FRAME. FABRICATED NEW FRAME FROM 6061 T4 0.020" AND INSTALLED FRAME IAW THE SRM. REMOVED FIBERGLASS ISOLATION PLY, NO FURTHER DAMAGE NOTED. REPLACED ISOLATION PLY. PREPPED AND PAINTED ASDR ABXR201006270019Intercostal · corrodedDURING MX, INTERCOSTAL BETWEEN S29L-S30L STA 1400-1420 FOUND CORRODED. CORROSION OUTSIDE OF SRM LIMITS. REMOVED AND FABRICATED NEW INTERCOSTAL WITH 7075 T-6 0.032". REINSTALLED INTERCOSTAL IAW THE SRM. ITEM RETURNED TO SERVICE.SDR ABXR201006270020Skin · delaminatedDURING MX, THE BOTTOM WEDGE OF THE NR 10 SLAT WAS FOUND DELAMINATED ON INBD END. REPAIRED DELAMINATED AREA IAW THE SRM. REPAIR FOUND TO COMPLY WITH SB 757-57A0038, REV 6. ITEM RETURNED TO SERVICE.SDR UALA2010062802307Slide · dislodgedDOOR 2R SLIDE PACK FALLING OFF. SECURED LOWER CENTER STRAP TO SLIDE COVER. DOOR OPENS AND CLOSES OK. SLIDE ARMS AND DISARMS OKAY.SDR DALA1019050662Cusp Web · corrodedMAIN CABIN CUSP WEB & ATTACHED STRUCTURE CORRODED STA 960-984 LT. R & R CUSP WEB AND ANGLE AT SAA SAT ON NON ROUTINE 166693.SDR DALA1019090662Cusp Web · corrodedMAIN CABIN CUSP WEB CORRODED STA 1020-1040, DOUBLER FWD OF STA 1040 ALSO CORRODED, INBD STR 17R. REMOVED CORROSION ON CUSP WEB AND REPLACED DOUBLER AT STA 1040 AT SAA SAT ON NON ROUTINE CARD.SDR DALA1019100662Cusp Web · corrodedMAIN CABIN CUSP WEB CORRODED STA 620-640 AT STR 17R / REPLACED CUSP WEB DURING HMV AT SAA ON N/R CARD 163871.SDR DALA1020000662Floorbeam · corrodedMAIN CABIN FLOORBEAM SURFACE CORRODED STA 1640, LBL 2 FWD SIDE AT FASTENER HOLE. COMPLIED WITH ER/A 483503-14 REV ORIG AT SAA DURING HMV ON N/R CARD 166753.SDR UALA2010062402255Line · leakingCTR HYD SYS QUANTITY READS .57RF ON LANDING. FOUND PIN HOLE LEAK AT STAB HYD MOTOR RETURN LINE AT AFT COMPT. IN PROCESS OF REMOVING LINE TO MFG IAW SAMPLE. REMOVED LINE AND SHOP REPAIRED REF R & R TAG R42781, REINSTALLED LINE AND LEAK CHECKS GOOD.SDR UALA2010062502267Microphone · inoperativeCAPTAIN OXYGEN MASK MICROPHONE INOP, R & R OXYGEN MASK. OPS ARE GOOD.SDR UALA2010062502268Control Valve · faultyLEFT ENG STARTER EICAS ON START. NO ROTATION. CYCLED D19, NO HELP. ACCMP'D MANUAL START. REPLACED STARTER CONTROL VALVE PER MM. OPS CHECKS NORMAL.
Back to Pratt & Whitney PW2037