Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009122303981Sensor · faultedAPU ALTITUDE NO START. APU HANGS BETWEEN 0-22 PERCENT DURING START. 0 EGT 23 PERCENT RPM IAW APU COLD START PROCEDURE. REPLACED APU BATTERY. REQUIRES APU HIGH ALT START BEFORE ACFT CAN BE ETOPS. APU ALTITUDE NO START. APU ROTATES BUT NO EGT INDICATIONS DURISDR UALA2009122303987Lanyard · out of positionDOOR 1R WON'T ARM. FOUND LANYARD FROM SLIDE WAS HANGING DOWN. RESTOWED LANYARD. DOOR ARMING OPS CHECKS GOOD.SDR UALA2009122303978Cable · out of adjustL2 DOOR EMERGENCY POWER ACTUATOR CABLE TRAVEL CHECK FAILED. ADJUSTED EMERGENCY POWER TRIGGER MECHANISM AND CABLE. OPS CHECK GOOD.SDR UALA2009122203959Spring · damagedDOOR NR4 RT GIRT BAR AFT LEAF SPRING DAMAGED. GIRT BAR SLIDER WON'T FULLY RETRACT. REPLACED SPRING.SDR UALA2009122203960Cover · unsecureDANGLING CORD OFF OF SLIDE PACK DOOR 2L. SECURED SLIDE COVER.SDR DL757092025Bulb · inoperativeEXTERIOR EMERGENCY LIGHTS INOP AT R2 DOOR. BOTH LT AND RT OVERWING AFT LOCATIONS. AND BOTH L3 AND R3 DOORS AND INTERIOR AT ROW 45. RELAMPED ALL LOCATIONS. LIGHTS CHECK GOOD EL.SDR UALA2009122103942Slide · faultyRT OVERWING EXIT SLIDE UNLACING. REMOVED AND REPLACED RT OVERWING EXIT SLIDE PACK.SDR UALA2009122103955Control Unit · malfunctionedHIGH STAGE BLEED ILLUM, FLIGHT DIVERTED. FROM SNA WITH BLEEDS OFF DUE TO EXCESS FUEL, POSSIBLE TRIGGER OF BOTH FAULTS. FOUND LT & RT HIGH STAGE PILOT CONTROL OVER PRESSURE INDS POPPED. RESET LT HIGH STAGE PILOT CONTROL, REPLACED RT HIGH STAGE PILOT CONTROL. RASDR UALA2009122103957Controller · malfunctionedLEFT ENGINE HIGH STAGE LT ILLUM & LT ENGINE HIGH STAGE EICAS MSG. FOUND HIGH CONTROLLER POPPED. REPLACED PILOT CONTROLLER. OP CHECKED NORMAL ON BLEED SHIFT RUN, BLEED PRESSURE NORMAL, NO FAULTS.SDR UALA2009122103939Cam · faultyDOOR 4R ARMING LEVER FAIL HALF WAY TEST. REMOVED AND REPLACED LOCKOUT CAM. OPS CHK'D GOOD.SDR UALA2009121803926Battery Pack · inoperativeEMERGENCY LIGHT L562 OVER LT WING IS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK, CHARGER AND LAMP; OPS CHK OK.SDR UALA2009121803925Lamp · inoperativeEXT EMERGENCY EGRESS LIGHT L568 FWD OF DOOR 4L IS INOPERATIVE. RELAMPED DOOR 4L, FWD SIDE L568 LIGHT, OPS CHK GOOD.SDR UALA2009122103934Feeder Cable · faultyEMERGENCY ESCAPE PATH LIGHTING STRIP INOP NEXT TO FWD CLOSET. CABLE FOUND FAULTY. ADJUSTED/SPLICED CABLE, OP CHKS OKAY.SDR UALA2009122103935Light · inoperativeEMERGENCY ESCAPE PATH LIGHTING STRIP INOP NEXT TO FWD AFT LAV. REPLACED AFT EMERGENCY LIGHT STRIP, CHECKS OK.SDR UALA2009121703905Actuator · malfunctionedELEVATOR ASYM MESSAGE DISPLAYED, IAW CREW. ACTUATOR FOUND FAULTY. REPLACED ACTUATOR M10048, OP CHECKS OK AND NO MESSAGES.SDR UALA2009121703908Light · inoperativeF-C EMERGENCY LIGHT STRIP AT LAV S KICK STRIP IS INOP. REMOVED AND REPLACED LIGHTING STRIP. GROUND OPS CK GOOD.SDR UALA2009121803915Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK M10568 AT SEAT 15DEF IS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AND OPS CHK.SDR UALA2009121803916Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK M735 LOCATED AT SEAT 23ABC IS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK, OPS CHK OKAY.SDR UALA2009121803917Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK M10699 AT SEAT 23DEF IS INOP. REMOVED AND REPLACED BATTERY PACK, OPS CK OK.SDR UALA2009121803913Cover · unsecureEMERGENCY LIGHTS COMING UP OFF FLOOR IN REAR OF AIRCRAFT. SECURED COVER.SDR UALA2009121803914Pan · damagedL2 DOOR PAN DENTED AND GOUGED OUTSIDE SURFACE. REMOVED AND REPLACED DOOR PAN. DOOR RIG IS WORKED IN CONJUNCTION WITH HK ROUTINE DOOR JC. PAN IS REPLACED.SDR UALA2009121803918Lamp · inoperativeEXT EMERGENCY EGRESS LIGHT L41 AFT OF DOOR 2R AT STA 735 RBL 73 IS INOPERATIVE. RELAMPED R2 DOOR EGRESS LIGHT, OPS CHK GOOD.SDR UALA2009121603890Sign · brokenEXIT SIGN BROKE OVER RT WING. OVERWING EXIT SIGN IS NOT BROKE, BUT IT IS BENT UP. IT CAN BE SEEN, READ AND USED WITH NO DIFFICULTY AS IS. SECURED SIGN OK.SDR UALA2009121603898Connector · unsecureLT AFT BOOST PUMP LOW PRESS LIGHT ON, EICAS MSG L AFT FUEL PUMP DISPLAYED. LT AFT BOOST PUMP CB (C366) TRIP AT P6 PANEL. FOUND PIN 1 AT CONNECTOR D1746 SHORTED TO GND OR SHIELD GND WITH CONNECTOR D41704P DISCONNECTED AT P33 PANEL POSITION 24. CONNECTOR D4170SDR UALA2009121503862Floorbeam · corrodedAFT GALLEY AREA, FLOORBEAM UPPER T-CAP HAS EXFOLIATION CORROSION AROUND FASTENER HOLES, TOP SURFACE IN SEVERAL AREAS, BS 1640.0, BL 0 TOP RBL 60. MAJOR REPAIR ACCOMPLISHED: REPLACED DAMAGED SECTION OF FLOORBEAM. REINSTALLED ADJ INTERCOSTALS AND FASTNENERS.SDR UALA2009121503863Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED AT STA 324 FROM RBL 42 TO RBL 66, UPPER T-CAP CORRODED. MAJOR REPAIR ACCOMPLISHED: REPLACED DAMAGED FLOORBEAM. REINSTALLED ADJ INTERCOSTAL AND FASTENERS.SDR UALA2009121503864Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED AT STA 365. 25 BETWEEN RBL 58 TO RBL 20. MAJOR REPAIR ACCOMPLISHED: DAMAGED FLOORBEAM. REINSTALL ADJ INTERCOSTAL AND FASTENERS.SDR UALA2009121503879Oxygen Mask · leakingF-O 02 MASK HARNESS LEAKS. FOUND HEAD HARNESS INFLATION COMPLETELY INOP DUE TO DISCONTINUITY OF BLADDER IN HARNESS. REPLACED MASK ASSY.SDR UALA2009121603889Feeder Cable · disconnectedEMERGENCY TRACK LIGHTING FROM SEAT ROW 9 TO ROW 14 INOP. FOUND EMERGENCY LIGHT STRIP POWER FEEDER DISCONNECTED. REPLACED DAMAGED LIGHT STRIP CHKS GOOD.SDR UALA2009121503866Lever · bindingMAIN CABIN L-2, DOOR HARD TO ARM-DISARM. FOUND ARM-DISARM LEVER BINDING ON DISARM INDICATOR FLAG. ADJUSTED INDICATOR FLAG AND COVER AND OPS CHECK GOOD.SDR UALA2009121503867Cap · missingEMERGENCY LIGHT NEEDS END CAPS AT SEATS 6B AND 13C. RESPLICED EMERGENCY LIGHT STRIP.SDR UALA2009121403856Drain · faultyNR 2 ENGINE IDG DRAIN BOSS IS STRIPPED OUT. REPLACED NR 2 ENGINE IDG DRAIN BOSS. LEAK CHECKED GOOD.SDR UALA2009121403861Transmitter · faultyNR 2 ENG OIL PRESS LIGHT ON OR FLUCTUATING. OIL PRESS INDICATES NORMAL RANGE. RT ENG OIL PSI FLUCTUATED 114-176 PSI FIRST TEN MINUTES OF FLIGHT. REPLACED MAIN OIL PRESSURE TRANSMITTER. RAN ENG, OPS AND LEAKED CHECKED NORMAL ON GROUND.SDR UALA2009121503886Monitor · faultyBURNING RUBBER ODOR NOTED IN AFT CABIN. FOUND COMING FROM 2ND TO LAST OVERHEAD MONITOR. DEACTIVATED OVERHEAD VIDEO SYS. REPLACED MONITOR AFT 2ND TO LAST AND CHECKED OKAY.SDR UALA2009121403848Life Raft · reads lowMAIN CABIN CEILING MOST AFT LIFE RAFT BOTTLE PRESSURE IS LOW. REMOVED AND REPLACED NR 2 POSITION LIFE RAFT.SDR UALA2009121403851Light · intermittentK-LAV FLOOR EMERGENCY LIGHT BAR IS INTERMITTTENT. REMOVED AND REPLACED K-LAV FLOOR EMERGENCY ESCAPE LIGHT BAR AND OPS CHECK GOOD.SDR UALA2009121403852Line · damagedCTR HYD LOW PRESSURE/QUANTITY, RTFL. RPL 2EA FLEX LINES. FOUND HOLE IN ONE AND THE OTHER FRAYED. THE UPPER LINE WAS THE COMPONENT THAT FAILED INDEPENDENTLY AND WAS A LINE FAILURE. HYD QTY DOWN TO 59 PERCENT, RESERVICED TO FULL. OPS CHK GOOD, NO LEAKS.SDR DL757091996Bracket · crackedNR1 PYLON RT STRUT UPPER CHORD WAS FOUND CRACKED AT A FASTENER LOCATION IN THE VERTICAL FLANGE JUST AFT OF THE BRACKET AT NSTA 136. THE CRACK PROPAGATED FROM THIS FASTENER LOCATION THROUGH THE CHORD RADIUS AND INTO A FASTENER LOCATION IN THE HORIZONTAL FLANGE SDR UALA2009121403837Wire · frayedEMERGENCY LIGHTS WIRES FRAYED AND EXPOSED AFT LT CABIN FLOOR. SECURED EMERGENCY LIGHT POWER STRIP. EMERGENCY LIGHTS OPS CHECKS OKAY.SDR UALA2009121403832Spring · damagedDOOR 1L SLIDE COVER COMING OFF. NEED MECHANIC TO INVESTIGATE AND CONTACT SAMC. ITEM ROLLED FWD. SAMC TEXT: UPDATE-SLIDE COVER NOT COMING OFF. PROBLEM WAS FWD GIRT BAR SLIDER HAD DETACHED FROM GIRT BAR. GIRT BAR LEAF SPRING DAMAGED AND WONT RETAIN SLIDER AS ISDR UALA2009121403833Girt Bar · cloggedAT GATE DOOR 3R WILL NOT DISARM. CLEANED PLASTIC WATER BOTTLE CAP OUT OF GIRT BAR SLIDE INTO ATTACHMENT POINT OF DOOR SILL. OPENED AND CLOSED DOOR A FEW TIMES AND ARMS AND DISARMS NORMAL NOW. LEFT IN DISARMED POSITION WHEN LEFT ACFT.SDR UALA2009121103825Lamp · inoperativeEXT EMERGENCY LIGHT AT DR 1R INOPERATIVE. RELAMPED.SDR UALA2009121103826Lamp · inoperativeEXT EMERGENCY LIGHT AT D00R 2R INOPERATIVE. RELAMPED.SDR UALA2009121103827Lamp · inoperativeEXT EMERGENCY LIGHT AT DOOR 3R INOPERATIVE. RELAMPED.SDR UALA2009121503883Module · faultedAPU HAD SHUTDOWN, FAULT LGT ILLUM AND EICAS MSG. APU FAULT DISPLAYED. APU INOP. FOUND DELTA P AND P2 SENSOR FAULTS ON ECU. REPLACED FLOW SENSE MODULE AND RAN APU FOR 20 MINUTES. OPS CHECK OK.SDR UALA2009121103820Turnbuckle · out of adjust4R DOOR EMERGENCY POWER MECHANISM CABLE NOT ADJUSTED PROPERLY, RED BAND NOT VISIBLE. ADJ SPRING CABLE TURNBUCKLE AND ALIGN RED BAND, OPS CHK GOOD, RED BAND IS VISIBLE.SDR UALA2009121103821Turnbuckle · out of adjustDOOR 2L EMERGENCY POWER MECHANISM CABLE NOT ADJUSTED PROPERLY, RED BAND IS NOT VISIBLE. ADJUSTED SPRING CABLE TURNBUCKLE AND ALIGN RED BAND. OPS CHK GOOD. RED BAND IS VISIBLE.SDR UALA2009121103818Cable · faultyEMERGENCY EVACUATION FLOOR LIGHT AT THE FWD CLOSET IS IN-OP. REPLACED LEAD IN CABLE. OPS CHECKS GOOD.SDR UALA2009120903804Warning Light · false activationDOOR OVERHEAD LIGHT & EICAS, FLT DIVERTED. CREW REPORTS AFT RT ENTRY DOOR OVERHEAD LIGHT AND EICAS. HANDLE CREPT UP AND WILL NOT STOW. NO PRESSURE LEAKS NOTED. OPENED DOOR AND INSPECTED DOOR SEALS, ROLLERS AND STOPS ALL CHECKED GOOD. ALSO INSPECTED DOOR ARMINSDR UALA2009121103813Cylinder · out of adjustDOOR 1L EMERGENCY POWER MECHANISM CABLE NOT ADJUSTED PROPERLY, RED BAND NOT PROPERLY POSITIONED. ADJ POWER SPRING CYLINDER. OPS CHECKED GOOD, RED BAND IS VISIBLE.
Back to Pratt & Whitney PW2037