Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010011500183Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED BS 1640, RBL 0 TO RBL 53. MAJOR REPAIR ACOMPLISHED: REPAIRED FLOORBEAM CAP TOP ANGLE RBL 58 TO LBL 10. REINSTALLED FLOOR SUPPORT AND ANGLES.SDR UALA2010011500184Cable · out of rigLT FWD OVERWING EXIT DOOR PULL HANDLE CABLE JAM NUT NOT SAFETIED. SAFETIED LT OVERWING EXIT DOOR PULL HANDLE CABLE. OP CHECKS NORMAL.SDR UALA2010011500186Wire · brokenMID GALLEY EMERGENCY LIGHTS INOPERATIVE. TROUBLESHOT AND FOUND WIRE BROKEN BELOW KICK STRIP AT MID GALLEY. REPAIR WIRE AT KICK STRIP, OPS CHECK.SDR UALA2010011500187Aileron Sys · malfunctionedAILERON CONTROL ISSUE, FLIGHT DIVERTED. INSPECTED CABLES AND PULLEYS FROM WHEEL WELL TO AILERON PCU'S BOTH LT AND RT WING. ALSO CHECKED AILERON QUADRANTS AND COLD SOAKED QUADRANT BRGS IN WHEEL WELLS AND DAMPER UNDER COCKPIT PIT FLOOR FOR TROUBLESHOOTING. NOSDR UALA2010011500198Stator · faultyLEFT ENG PRI CONT, ACFT RETURN TO GATE NO TIME TO WORK. MSGS ON EPCS PG: P PDIU- (EEC), EEC,S PDIU-(EEC),S 274-18 ALL ERASED AND DID NOT RETURN DURING DEFFERAL. ACCMP'D PARTIAL FIM 7 1-EPCS FOR MESSAGE P-S LABEL 274-18, ALL WIRES CHECK OK FOR CONTINUITY AND NOSDR UALA2010011500180Control Panel · brokenEMERGENCY LIGHT SWITCH COVER ON OVER HEAD PANEL BROKEN. REPLACED EMERGENCY LIGHTS OXYGEN CONTROL PANEL.SDR UALA2010011300164Warmer · odorODOR IN AFT GALLEY. DEACTIVATED COFFEE WARMER PLATES FOR FURTHER TROUBLESHOOTING OF ODOR. NEEDS TROUBLESHOOTING FOR SOURCE OF ODOR. REPLACED COFFEEMAKER M40 & CLEANED COFFEE WARMER. TURNED ON & OPS CK'D COFFEEMAKERS & WARMERS, NO ODOR NOTICE. INSPECTED WISDR UALA2010011300165Gate · corrodedL1 DOOR LOWER GATE CORRODED AND CRACK. REMOVED AND REPLACED DOOR 1L LOWER GATE. OPS CHECK WILL BE ACP ON C-CK ROUTINE JC.SDR UALA2010011300163Skin · gougedR1 DOOR EXT SKIN INNER DOUBLER GOUGE JUST BELOW THE UPPER HINGE. GOUGES FOUND TO BE OUT OF LIMIT, REMOVED DAMAGE, FABRICATED AND INSTALLED DOUBLER IAW SRM 52-10-01, P201 AND SRM 51-40-02. WORK IS ACP NR 27976 A ND INSP BY QC 349.SDR UALA2010011100134Computer · inoperativeCREW REPORTED LT EICAS COMPUTER INOPERATIVE. COMPUTER FOUND FAULTY. INSTALLED NEW EICAS COMPUTER. VERIFIED OPS & OPC SOFTWARE ON LT EICAS COMPUTER IAW MOPS.SDR UALA2010011100141Light · looseFLOOR EMERGENCY LIGHT STRIP AT SEAT 14 RIPPED UP. TRACK & LIGHT STRIP ARE DAMAGED. SECURED EMERGENCY LIGHT AND NEW COVER.SDR UALA2010011200148Seal · damagedHIGH PITCH SQUEAL FROM F/O SLIDING WINDOW, RTFL. SUSPECTED AREA OF SQUEAL IS FWD UPPER CORNER OF WINDOW. PUSHING ON WINDOW FRAME NO HELP IN ATTEMPT TO QUIET OR ALTER SQUEAL PITCH. REPLACED F-O'S SLIDING WINDOW PRESSURE SEAL. PRESSURIZED ACFT TO 4.5 DPSI, NO SDR UALA2010011200149Structure · damagedDR 4 LT & RT DOOR STOP TEE CLIP. ACP COA 506902 DOOR NR4 LT & RT DOOR STOP TEE CLIP. INSP IAW 5C0690201 INSP QC194.SDR UALA2010011100130Yoke · obstructedAILERON CONTROL STIFF IN FLT ABOVE 200 KTS. ACP TEST FLT. ACTUATE AILERONS IN ALL PHASES OF FLT ABOVE & BELOW 200 KTS. FOUND SPOILERS 4 & 9 EXTENDED & NOT ALIGNED WITH WING, 5 & 8 MEASURED 19 IN. INSTEAD OF 9.19 IN. & 6 & 7 MEASURED 15 IN. INSTEAD OF 7.05 ISDR UALA2010011100131Mechanism · out of adjust3R DOOR WON'T ARM. FOUND A STIFF BEARING ON UPPER TORQUE TUBE OF DOOR EMERGENCY MECHANISM. CLEANED AND LUBED BEARING. DOOR ARMS PROPERLY. ALSO ADJUSTED EMERGENCY MECHANISM.SDR UALA2010011100121Cover · faulty3R SLIDE LIGHT BLINKS ON AND OFF WITH DOOR DISARMED. DOOR 4R SLIDE COVER HOOK ASSY INSERTS PULLED OUT. REPLACED ENTIRE COVER ASSY. LIGHT CKS NORMAL.SDR UAL2010F00000Actuator · trippedL/E SLAT DISAGREE MESSAGE, RTFL SLAT-FLAP OPS STOPPED AT AN INDICATED POSITION JUST LESS THAN 1. ACCOMPLISHED REVIEW OF FSEU LAST FLIGHT FAULT SHOWS L/E DISAGREE MSG NR 310. VISUALLY CHECK L/E ROTARY ACTUATORS. NR 6 INBD ROTARY ACTUATOR WAS TRIPPED. ALL OTHESDR UALA2010011100123Actuator · malfunctionedLE SLAT DISAGREE MSG, RTFL. SLAT-FLAP OPS STOPPED AT AN INDICATED POSITION JUST LESS THAN 1. ACCOMPLISHED REVIEW OF FSEU. LAST FLIGHT FAULT SHOWS L/E DISAGREE MSG NR 310. VISUALLY CHECKED L/E ROTARY ACTUATORS. NR 6 INBD ROTARY ACTUATOR WAS TRIPPED. ALL OTHERS SDR UALA2010011100110Clamp · wornBLOCK CLAMP THAT SUPPORTS 3 HYD TUBES INSIDE LT WING PANEL 511KT IS WORN TO THE POINT THAT THE LOWER 2 TUBES ARE ALMOST TOUCHING. CLAMP FOUND WORN. REPLACED BLOCK CLAMP.SDR UALA2010011100111Lamp · inoperativeLT AFT OVERWING EXIT EMERGENCY EXIT LIGHT OUT. RELAMPED AND OPS CHECKED THE LT AFT OVERWING EXIT EMERGENCY EXIT LIGHT. OPS CHECKED GOOD.SDR UALA2010010800105Idg · faultyEICAS MSG L GEN DRIVE DISPLAYED.GEN DRIVE LGT ILLUM. GEN DRIVE DISCONNECTED. CREW COMMENTS: L GEN DRIVE LIGHT ON. APU OK. FOUND L ENG IDG WITH MULTIPLE HOLES, DIFF PRESS INDICATOR POPPED. DRAINED IDG OIL, SMELLED NO EVIDENCE OF FUEL. MOTORED ENGINE TO ENSURESDR UALA2010010800104Idg · leakingOIL ACTIVELY DRIPPING OUT OF LT ENG. R & R NR1 ENG IDG. BITE CHECKED BPCU "HIGH IDG TEMP RISE" CHECKED IDG LEVEL LOW. SERVICED IDG, RAN L ENG. LOADED ELEC SYS OPS GOOD FOR LT IDG. VERIFICATION FLIGHT CONFIRMS NORMAL OPERATION.SDR UALA2010010700099Idg · faultyEICAS MSGS L GEN DRIVE LGT DID NOT ILLUM WITH ENG SHUTDOWN. REPLACED NR1 ENG IDG. FLEW ONE SEGMENT AND FOUND L ENG IDG WITH MULTIPLE HOLES, DIFF PRESS INDICATOR POPPED. DRAINED IDG OIL, SMELLED NO EVIDENCE OF FUEL. MOTORED ENGINE TO ENSURE IDG DISCONNECTESDR UALA2010010700087Shutoff Valve · failedAPU BLD AIR DUCT PRESS LO APPROX 18 PSI FOR LT ENGINE START. PROBLEM RELATED TO LOW PNEUMATIC DUCT PRESSURE. NR 1 ENGINE PRSOV WOULD NOT CLOSE. REPLACED PRSOV AND APU PNEUMATICS OP CHECK OK.SDR UALA2010010500076Relay · faultyRT/LT WING ANTI-ICE VLV IND, FLIGHT DIVERTED. WITH WING ANTI-ICE SW SELECTED ON, LT, RT VALVE LIGHTS REMAINED EXTINGUISHED. NO EICAS MESSAGE DISPLAYED. REPLACED K204 RELAY. ACP SYS OPS CK. OPS CK OK.SDR UALA2010010700077Switch · faultyDOOR 3L SLIDE ARMED CONDITION LIGHT ABOVE DOOR INOP. SWITCHED LENS COVERS WITH DOOR 3L, NO HELP. REPLACED SWITCH S10222, TESTS OK. COMPLETED RII INSP OF 3L SLIDE ARMING INDICATION, ALL OPS NORMAL.SDR UALA2010010500058Slide · faultyDOOR 4L SLIDE NEEDS REPLACEMENT. REPLACED SLIDE. ACCOMPLISHED RII INSTALLATION INSPECTION OF NR 4 SLIDE. NO DEFECTS NOTED.SDR UALA2010010500059Reservoir · unknownNR 4L PASSENGER DOOR EMERGENCY POWER RESERVOIR NEEDS REPLACEMENT. REPLACED IAW MM 52-11-30. OPS CHECKED GOOD.SDR UALA2010010700093Fan · malfunctionedCREW REPORT: ELEC BURNING SMELL 13000 & 20000 ALT. *S/D* FOUND EICAS MESSAGE AFT EQ EXH FAN 1, REPLACED FAN. ACP HIGH POWER RUN AND CHECKED ECS SYSTEM FOR ODOR, FOUND NO ODOR FROM PACKS. COULD NOT DUPLICATE ANY TYPE OF BURNING SMELL THROUGHOUT THE AIRCRASDR UALA2010010400037Socket · dirty4 RT MED EXTERIOR EMERGENCY EVACUATION LIGHT INOPERATIVE. CLEANED SOCKET, OPS GOOD.SDR UALA2010010400028Water Heater · overheatedFWD AFT LAV SMOKE DETECTOR WENT OFF (REPEAT). HOT IRON TYPE ODOR EMANATING FROM THAT LAV. UPDATE-CREW TURNED OFF WATER HEATER AND RAN ALL HOT WATER OUT OF HEATER. ODOR HAS NOW DISSIPATED. NO SMOKE WAS SEEN. SMOKE DETECTOR OK. WATER HEATER OVERHEATING. ITSDR UALA2010010400035Engine · flamed outLT ENG FLAMEOUT. NO CONTAMINATION IN FUEL PUMP FILTER WAS NOTED. NO MX MESSAGES OR STATUS MESSAGES. MASTER OIL CHIP DET OK. NOTE- AT GATE, PILOT 2ND START HUNG AT 39 PERCENT N2, 384 EGT, FUEL FLOW 600LBS. REPLACED RT GCU, NO HELP. REINSTALLED OLD GCU. FOUSDR UALA2010010400005Light · inoperativeEXT EVAC LT INOP AT DOOR 1 RT, RELAMPED.SDR UALA2009123104068Lamp · inoperativeLT AFT EMERGENCY LIGHT ON STOWBIN BULL NOSE IS INOPERATIVE. RELAMPED, OPS CHECKS GOOD.SDR UALA2009123004063Window · damagedRH FWD WINDSHIELD SHATTERED. FWD RT WINDSHIELD SHATTERED BUT STILL IN PIECE. REPLACED NR 1R WINDSHIELD.SDR UALA2009123104070Smoke Detector · faultyFWD AFT LAV SMOKE DET ALARMING AND WILL NOT RESET. REPLACED FWD AFT LAV SMOKE DETECTOR, OPS CHECKS OK.SDR UALA2009123004062Oxygen Mask · defective#2 OXYGEN MASK MIKE IS INOP. SUPPLEMENTAL DATA UPDATE MASK ASSY FOUND DEFECTIVE. REPLACED 1ST OFFICER'S OXY MASK ASSY. OP CHKS NORMAL.SDR UALA2009123004065Panel · delaminatedNR 1 ENG OTBD REVERSER UPPER BIFURCATION PANEL HAS DELAMINATION APPROX 265 SQUARE INCHES. REPAIRED NR 1 ENG OTBD REVERSER BIFURCATION PANEL.SDR UALA2009122804021Slide · faultyDOOR 3R SLIDE PACK LOW PRESSURE. REPLACED DOOR SLIDE AT 3R. INSPECTED SLIDE FOUND SECURED ON DOOR, REMOVED AND STOWED SLIDE PIN, REMOVED AND STOWED DOOR ASSY BOTTLE PIN.SDR UALA2009122804016Light · inoperativeEXIT LIGHT AT DOOR 1R BY THE LINEN DISPOSAL COMP IS INOP. REPLACED EXIT LIGHT, OPS CHECKS GOOD.SDR UALA2009122804019Battery Pack · inoperativeL1 & L2 EXTERIOR EMERGENCY LIGHTS INOP. REPLACED BATTERY PACK FOR L1-L2 EXTERIOR EMERGENCY LIGHTS, OPS CHECK GOOD.SDR UALA2009122804015Oven · smokeELECTRICAL SMOKE SMELL IN CABIN CENTERED AROUND DOOR 2L DURING DESCENT. SUPPLEMENTAL DATA UPDATE ACP CHECK OF ALL LIGHTING SYSTEM IN ACFT ON BRIGHT AND DIM, CHECKED MONITORS AND VIDEO SYSTEM AND ALL UNDER SEAT WIRING NO DEFECTS FOUND. ACP OPS CK OF PACKS AND RSDR UALA2009122804029Fuel Tank · leakingFUEL LEAKING FROM LT WHEEL WELL FROM CTR TANK. FOUND LEAK IN CTR LT REAR SPAR LWR CORNER SEALANT REPAIRED W A-HALF AND B-HALF AT 1400HRS. NEEDS LEAK CHECK REPAIR. NO LEAKS FOUND.SDR UALA2009122804031Valve · leakingFUEL LEAK DOWN LEFT MLG DOOR. FOUND LT WING FUELING VALVE CONTROL LEAKING. REPLACED WITH A SERVICEABLE UNIT. LEAKED CHECKED OKAY. ALL WORK ACCOMPLISHED.SDR UALA2009122403991Linkage · damagedDOOR 3L WILL NOT ARM. FOUND SHEARED BOLT IN ARMING MECHANISM. WILL NEED BOLT, WASHERS & NUT. REPLACED BOLT, NUT, WASHER AND COTTER PIN FOR SLIDE ARM LINKAGE AT GIRT BAR. DOOR OPS NORMAL.SDR UALA2009122403989Light · inoperativeCABIN AISLE EMERGENCY EXIT STRIP LIGHTING ON SEAT 21ABC INOPERATIVE. REPLACED SEAT EMERGENCY LIGHT STRIP.SDR UALA2009122303983Bracket · damagedLH ENG STRUT PLUMBING INSP: FOUND PRESSURE LINE CLAMP BLOCK FASTENERS SHEARED AND FASTENER HOLES ELONGATED IN CLAMP BLOCK BRACKET AT NAC STA 149.5. REPLACED BRACKET, BLOCKS AND CHANNEL RETAINER.SDR CALA2013082990832Doubler · damagedL2 REPAIR DOUBLER AT UPPER HINGE CUT OUT DAMAGED, WU 33083. REMOVED EXISTING DAMAGED DOUBLER AT UPPER HINGE CUT-OUT ON FORWARD FRAME. FORMED A REPAIR ANGLE & INSTALLED IAW REO G13168, REV. B & UAL EVA 73214. L2 DOOR UPPER HINGE CUTOUT AREA REMOVED & REPLACSDR UALA2009122303979Slide · unsecureLT OVERWING EXIT SLIDE UNLACING. REMOVED AND REPLACED LT OVERWING SLIDE.SDR UALA2009122303980Structure · damagedL-2 REPAIR DOUBLER AT UPPER HINGE CUTOUT DAMAGED. MAJOR REPAIR ACCOMPLISHED: REMOVED EXISTING DAMAGED DOUBLER AT UPPER HINGE CUTOUT ON FWD FRAME. FORMED A REPAIR ANGLE AND INSTALLED.
Back to Pratt & Whitney PW2037