Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL757090013Gearbox · making metalON CLIMB OUT PASSING 11000 FT HAD RT ENGINE FAILURE. FOUND METAL ON MGB CHIP DETECTOR REMOVED PMA STATOR FOUND DAMAGE ON STATOR AND ROTOR ASSY. INSTALLED BOROPLUGS AND TURNING PAD COVER PER AMM. REMOVED MAIN AND ANGLE GEARBOXES PER E/M, OK TO INSTALL MAIN SDR UALA2009010500051Lanyard · out of positionDOOR 1R SLIDE WILL NOT ARM. SECURED LANYARD IN PROPER POSITION. ARMED DOOR SEVERAL TIMES, CKS GOOD.SDR UALA2009010200011Light · inoperativeDOOR NR 1 LT EMERGENCY EXIT LIGHT INOP (EXT). RELAMPED, CHECKS GOOD.SDR UALA2008123107061Light · inoperativeRT FWD OVER WING SLIDE EMERGENCY EXIT LIGHT INOP. RELAMPED, OPS CK GOOD.SDR UALA2008123107062Light · inoperativeNR 1 RT FWD DOOR EXTERIOR EMERGENCY LIGHT INOP. RELAMPED, OPS CHECK OK.SDR UALA2008123107063Light · inoperativeNR 3 RT MED EXTERIOR EMERGENCY LIGHT INOP. RELAMPED. OPS CHECKED OKSDR DL75E090014Pca · malfunctionedSPOILER MSG AND LIGHT FOUND FUSE LIGHT ON SCM 2R FAULT POWER CONTROL ACTUATOR (PCA) NR 3. INSTALLED KNOWN GOOD SAM AT 2R. NO HELP. REPLACED FUSE. REMOVED C/P FROM NR 3 PCA. NO FUSE LIGHT ON SCM 2R NOW. INSTALLED C/P AT PCA NR 3.506080. REMOVED PCA NR 3SDR UALA2008123007046Fuel/Oil Cooler · failedLOST LT GENERATOR. FUEL COOLED OIL COOLER REPLACED. UNIT SO FAR PASSING TEST. ONLY RAN 100 PSI BUT NO LEAKS DETECTED.SDR UALA2008123007037Skin · delaminatedRT ELEVATOR LOWER CENTER EXT SURFACE HAS DELAMINATED BROKEN AREA AT ELEV STA 220. REMOVED DAMAGE AND ACCOMPLISHED CARBON FIBER REPAIR.SDR UALA2008122907026Generator · damagedAFTER APU START UP, OIL RUNNING FROM UNDERNEATH OF GEN TERMINAL BLOCK. CTR 2 FIELD STUDS APPEAR TO BE BROKEN. REPLACED APU GENERATOR AND FEEDER CABLES. NO LEAKS DURING APU OPS CHECK.SDR UALA2008122907028Controller · out of toleranceREPLACE NR 1 RT WINDOW HEAT CONTROLLER ACCT SHATTERED WINDOW. R&R CRACKED WINDOW. REPLACED NR 1 RT WINDOW HEAT CONTROLLER.SDR UALA2008123007048Actuator · leakingRT AILERON HAS EXCESSIVE FLUID RUNNING OUT OF IT. REPLACED RT INBD AILERON PCA. OPS AND LEAK CHKS GOOD.SDR UALA2008122907025Light · inoperativeDOOR 1R SLIDE LIGHT INOP. RELAMPED, OPS CKS GOOD.SDR UALA2008122607012Fuel Control · failedAIRCRAFT RTFL DUE TO APU NO START AT ALTITUDE. PILOT REPORTS: APU HUNG AT 27 PERCENT DURING ALTITUDE OF 34,000 MSL AND THEN FAULTED, SHUT DOWN. REPLACED APU FUEL CONTROL DUE TO FAULTY FUEL SOLENOID.SDR UALA2008122407002O-Ring · leakingLOW PRESSURE PULLEY STEM LEAKING. REMOVED & REPLACED SHAFT O-RING AND BACK-UP RING.SDR UALA2008122306978Inverter · inoperativeAFT LOWER EXIT SIGNS AND 2 AISLE ILLUMINATION LIGHTS FAIL TO ILLUMINATE DURING TEST. NEEDS INVERTER, LOCATED ABOVE AFT GALLEY CEILING AFT OF MID FLORESCENT LIGHT AND 2 BAD LAMPS. CK'D GOOD.SDR UALA2008122406987Cylinder · corrodedLT MLG OUTER CYLINDER IS CORRODED. OUTER CYLINDER CORROSION REPAIRED. REPLACED STRUT SEALS. PRESSURE CHECKED OK.SDR UALA2008122406993Structure · damagedR2 DOOR REQUIRES REPAIR DOUBLER AT UPPER HINGE CUTOUT. PERFORMED HFEC INSPECTION PER NDT MANUAL 6-51-00-19 ON UPPER HINGE CUTOUT, AND FOUND NO CRACKS NOTED AT THIS TIME AS DOCUMENTED ON NON ROUTINE 25462 BY IN SP QC077. THIS REPAIR WILL BE ACCOMPLISHED AS PRSDR UALA2008122406994Structure · damagedMAJOR REPAIR: L2 DOOR REQUIRES REPAIR DOUBLER AT UPPER HINGE CUTOUT. PERFORMED HFEC PER NDT 6-5 1-00-19 ON UPPER HINGE CUTOUT AND FOUND NO CRACKS NOTED AT THIS TIME AS DOCUMENTED ON NON ROUTINE 25463 BY INSP QC077. THIS REPAIR WILL BE ACCOMPLISHED AS A PREVSDR UALA2008122206924Starter · faultyAPU FAILED TO START. FAULT LGT ILLUM AND EICAS MSG. APU FAULT DISPLAYED. ADDITIONAL START ATTEMPTS UNSUCCESSFUL. CREW COMMENTS: 4 ATTEMPTS UNSUCCESSFUL. EGT ROSE TO 790 RPM 21. AUTO SHUTDOWN. REMOVED & REPLACED APU STARTER. OP CHECKS GOOD.SDR UALA2008122306969Feeder Cable · damagedG2A GALLEY EMERGENCY LIGHT FEEDER CABLE DAMAGED. REPAIRED G2A GALLEY EMERGENCY LIGHT FEEDER CABLE AND OPS CHECK GOOD.SDR UALA2008122306970Feeder Cable · damagedG1B GALLEY EMERGENCY LIGHT FEEDER CABLE DAMAGED. REPAIRED G1B EMERGENCY LIGHT FEEDER CABLE AND OPS CHECK GOOD.SDR UALA2008122206949Panel · delaminatedAPU COMPARTMENT RT INTERIOR PANEL DELAMINATED. FABRICATED A CORE PLUG, INNER SKINS AND DOUBLER AND INSTALLED.SDR UALA2008122206950Frame · dentedAFT PIT FRAME DENTED BS 1440, STR 26L. MAJOR REPAIR ACCOMPLISHED. REPAIRED FRAME DENT AT STA 1440 WITH FABRICATED J-ANGLE REPAIR.SDR UALA2008122206957Bleed Valve · faultyTHE L ENG BLEED WON'T CLOSE WITH SWITCH OFF. CYCLE LEFT END START SW AND APU BLEED OPENED. ALL INDICATIONS NORMAL. REPLACED RELAY K10282 LT AIR SUPPLY ENGINE START RELAY. REPLACED AIR GROUND SYS 2 RELAY K10201. OP CHECKS GOOD ON ENGINE RUN.SDR UALA2008122206926Actuator · faultyEICAS MESSAGE 'ELEV ASYM' IS DISPLAYED. REPLACED ASSY LIMITER ACTUATOR. CHECKS OKAY.SDR UALA2008122206947Cover · damagedEEL STRIP COVER FROM ROW 25 TO BACK OF ACFT CHEWED UP AND BROKEN. REPLACED COVER STRIP.SDR UALA2008122206948Transceiver · faultySECOND TIME RECEIVE INOP HF RIGHT RADIO FREQ 5574. RETUNE, NO HELP. REPLACED RT HF TRANSCEIVER AND F/O'S AUDIO SELECT PANEL. OPS CHECK FOR RT HF NOW TESTS OK.SDR UALA2008121906921Skin · dentedEXTERNAL FUSELAGE SKIN DENTED AT STA 1660 AND BETWEEN STR 26L-27L AT LAV SERVICE DOOR CUTOUT. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE. FABRICATED AND INSTALLED FILLER, DOUBLER AND TRIPLER.SDR UALA2008122206929Skin · dentedEXT FUSE STA 560 TO STA 600 BELLY SKIN (LBL 10 TO RBL 10) HAS NUMEROUS ARCHIVED DENTS. MAJOR REPAIR ACCOMPLISHED. CUTOUT DAMAGED SKIN AND INSTALLED DOUBLER REPAIR.SDR UALA2008122206931Frame · dentedFWD CARGO COMPT, FRAME HAS A DENT BS 520 AND BETWEEN STR 24L-25L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE AND INSTALLED J-ANGLE REPAIR.SDR UALA2008122206935Frame · dentedFWD CARGO COMPT, FRAME HAS SEVERAL DENTS AT LT BS 540 AND BETWEEN STR 24L-25L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED J-DOUBLER REPAIR.SDR UALA2008122206932Feeder Cable · damagedG4A GALLEY EMERGENCY LIGHT FEEDER CABLE DAMAGED. RE-TERMINATED AND INSTALLED G4A GALLEY EMERGENCY LIGHT FEEDER CABLE AND LIGHT ASSY, OPS CHECKS GOOD.SDR UALA2008122206933Connector · damagedA-ZONE EEL SEAT CABLE DAMAGED. REPLACED CONNECTOR, OPS CHECKS GOOD.SDR UALA2008122206934Feeder Cable · damagedA-ZONE EMERGENCY LIGHT SEAT FEEDER CABLE DAMAGED. REPAIRED WIRES, OPS CHECKS GOOD.SDR UALA2008121806916Bypass Valve · faultyNR 2 ENG HIGH OIL CONSUMPTION EXCEEDS LIMIT. DUE TO INCREASE IN OIL CONSUMPTION & NO LEAKS REPORTED DURING HIGH POWER REPLACED FCOC & BYPASS VALVE.SDR UALA2008121806918Idg · failedTHE R GEN DRIVE LIGHT ON WITH ASSOCIATED EICAS DURING TAXI OUT. VERIFIED GEN BAD. GEN OIL SMELLED BURNED. REPLACED RT ENG IDG. OPS NORMAL.SDR UALA2008122206925Control Unit · no testHMG DOES NOT TEST. REPLACED HYDRAULIC MOTOR GENERATOR CONTROL UNIT. OP CHECKS OKAY.SDR UALA2008121906920Computer · failedAUTOPILOT FAILURE. FLT DIVERTED. SUPPLEMENTAL DATA UPDATE FOUND MULTIPLE INFC FAULTS AND CENTER FCC FAILED. CTR FCC PULLED DOWN INTERCONNECT BUS. REPLACED CENTER FLIGHT CONTROL COMPUTER AND CHECKS OK.SDR UALA2008121706911Battery Pack · inoperativeEEL LIGHTS AFT OF ROW 31 INOP. EXIT SIGN INOP OVER DOOR 4R. AISLE LIGHTS INOP ROWS 27 & 31, SLIDE LIGHT INOP DOOR 4R. REPLACED BATTERY PACK & POWER SUPPLY AT POSITION M10817.SDR UALA2008121806915Bypass Valve · leakingNR 1 ENGINE HOC. FOUND NR 1 ENG FUEL-OIL HEAT EXCHANGER LEAKING OIL- INTO FUEL. REPLACED NR 1 FOX & BYPASS VALVE ASSY. OP CHECKED GOOD ON HIGH POWER RUN, NO LEAKS NO FAULTS.SDR UALA2008121806917Charger · failedMAIN BATTERY CHARGER EICAS MSG PRESENT. REPLACED MAIN BATTERY CHARGER UNIT. OP TESTED NORMAL.SDR UALA2008121506900Fuel Control · failedL ENG SEC CONT MSG DISPLAYED. REPLACED FCU. ACCMP TEST 2A IAW MM 71-00-59 ON NR 1 ENG FCU, NO LEAKS NOTED. ACCOMPLISHED ENGINE RUN PER JRH 2-95-1 AND 71-00-59, NO FAULTS NOTED.SDR UALA2008121606903Anti-Ice Valve · faultyAFTER HIGH POWER RUN FOUND RIGHT WING ANTI ICE VALVE FAILED TO OPEN CORRECTLY. REPLACED RT WING ANTI ICE VALVE.SDR UALA2008121706914Transceiver · failedRIGHT HF WILL RECEIVE BUT WILL NOT TRANSMIT. REPLACED NR 2 HF TRANSCEIVER.SDR UALA2008121506888Girt Bar · unsecureGIRT BAR AT DOOR 4R HAS FALLEN ON FLOOR. SECURED DOOR 4R GIRT BAR INSTALLATION.SDR DL75E081736Shutoff Valve · malfunctioned36-11-01 RIGHT ENG BLEED INOP. FLT CREW PLAC PER MEL 36-11-01 MTC NOTIFIED 1530Z MTC COORD. FOUND PRSOV WOULD NOT FULLY CLOSE WHEN MANUALLY OPENED PER FIM. REPLACED SAME ENGINE, RUN CKS GOOD. MCO/PLACARD REMOVED.SDR UALA2008121506874Light · inoperativeEMERGENCY EGRESS LIGHT AT ROW 15A IS INOP. REPLACED LIGHT AND OPS CHECK GOOD.SDR UALA2008121506877Frame · dentedAFT CARGO COMPARTMENT, FRAME DENTED BS 1380, STR 25L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR UALA2008121506878Frame · dentedAFT PIT FRAME DENTED BS 1400, STR 26L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.
Back to Pratt & Whitney PW2037