Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA03259Stringer Splice · mismanufacturedRIGHT WING UPPER STRINGER SPLICES 757-3503 -8 AND -10 HAVE SHORT EDGE MARGIN (WINGLET MOD). ACCOMPLISHED MAJOR REPAIR AT GSO-TRIMMED -8 STR SPLICE PER REO-G12358. NDT INSP PER PT 6, 51-00-19. NO DEFECTS NOTED. ROTO PEENED PER REO AND SRM 51-20-13. INSTALLESDR 2008UALA03260Fitting · crackedNR 1 PYLON "DELTA" FITTING CRACKED ON OUTBOARD SIDE. ACCOMPLISHED MAJOR REPAIR AT GSO. REPLACED DELTA FITTING PER SRM 51-40-02. LEAK CHECKED ALL LINES PER MM 29-00-98, LEAK CHECKS GOOD.SDR 2008UALA03221Wire Harness · shortedCREW REPORT: WX FAIL RADAR SAMC TEXT: ANTENNA MSG ON BOTTOM OF SCREEN. RESET CB TO TRANCVR UNIT, NO HELP. HARNESS SHORTED FROM FWD BULKHEAD TO SCANNER. REPLACED HARNESS.SDR 2008UALA03229Intercostal · crackedCABIN, JUST FWD OF L-2 DOOR CUTOUT, STR 12 CHORD SHOWS EVIDENCE OF CRACK JUST BELOW RADIUS BLOCK. MAJOR REPAIR ACCOMPLISHED: REMOVED INTERCOSTAL WEB. FORMED & INSTALLED NEW INTERCOSTAL WEB (P/N 143N8334-27).SDR 2008UALA03235Unknown · malfunctionedINBOARD CREW REPORTS DOOR 1 RIGHT HARD TO ARM.SDR 2008UALA03212Frame · dentedAFT CARGO FRAME DENTED STA 1520, STR 26L. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE & INSTALLED DOUBLER REPAIR.SDR 2008UALA03197Girt Bar · out of positionSLIDE ARMED LIGHT INOP 4R. FOUND AFT END OF GIRT BAR NOT IN THE FLOOR CLEET WHEN IN THE ARMED POSITION. POSITIONED GIRT BAR AND CYCLED SEVERAL TIMES AND LIGHT OP CHECKS OK.SDR 2008UALA03217Sensor · dirtySLIDE ARMED INDICATOR LIGHT DOOR 3R BULB NOT LIT AFTER ARMING. DOOR SENSOR/SLIDER TARGET DIRTY. CLEANED DOOR SLIDER TARGET SENSOR, OPS CHECKED OK.SDR 2008UALA03218Bottle · leakingDOOR 1 LEFT SLIDE PRESSURE IS ONE NEEDLE OUT OF THE GREEN BAND. PRESSURE LEAK IN SLIDE BOTTLE. REPLACED SLIDE ASSY.SDR C8G2008F00001Eec · inoperativeDURING CLIMB OPERATION, OIL PSI WENT TO -4, N1=0, N2=0, ENGINE SHUTDOWN. AC RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. TROUBLESHOT SYSTEM AND FOUND EEC TO BE AT FAULT. REMOVED AND REPLACED EEC, OPS AND LEAK CHECKS GOOD. NO OTHER DEFECTS NOTED.SDR C8GA20080017Eec · malfunctionedFLT P0002 FROM PTY TO MFA. DURING CLIMB OPERATION OIL PSI WENT TO -4, N1=0, N2=0 ENG SHUTDOWN. ACFT RETURNED TO PTY WHERE IT LANDED WITHOUT INCIDENT. TROUBLESHOT SYSTEM AND FOUND EEC TO BE AT FAULT. REMOVED AND REPLACED EEC, OPS CHECKS GOOD. NO FURTHER DESDR 2008UALA03175Frame · dentedAFT PIT FRAME TOP CHORD BENT OVER STA 1440, STR 27L. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGE. INSTALLED FRAME REPAIR.SDR 2008UALA03185Door Frame · damagedL2 DOOR REQUIRES REPAIR DOUBLER AT UPPER HINGE CUTOUT. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.SDR 2008UALA03180Light · inoperativeEMERGENCY EXIT LIGHT ROW 15 TO ROW 20 INOP. LOOSE CONNECTOR. SECURED LOOSE CONNECTOR AT SEAT 20, ALL OPS OK.SDR 2008UALA03184Structure · corrodedL4 DOOR HANDLE BOX HAS CORRODED INSERTS ON TOP OF BOX. INSTALLED NEW HANDLE BOX PER UAL SM 50-52-11-06-JD.SDR 2008UALA03186Door Frame · crackedR2 DOOR UPPER HINGE CUTOUT CRACKED. MAJOR REPAIR ACCOMPLISHED: INSTALLED FRAME REPAIR.SDR 2008UALA03198Warning System · malfunctionedL ENG SEC CONT STATUS MESSAGE. CHECKED FOR EPCS MESSAGES LISTED ON MM CHAPTER 71 EICAS AND EPCS MESSAGES SERVICE TIP, NO MESSAGES FOUND. ERASED STATUS MESSAGE. PUT EEC SWITCH ON P61 PANEL TO SEC POSITION, NO MESSAGES APPEARED. ACFT OK FOR SERVICE.SDR 2008UALA03157Seat Track · corrodedCABIN, PREVIOUS REPAIR ON END OF SEAT TRACK BS 377.7 IS CORRODED, APPROX RBL 40. ACCOMPLISHED MAJOR REPAIR AT GSO. REMOVED DAMAGE AND FABRICATED REPAIR IAW REO G12351 REV B.SDR 2008UALA03167Skin · corrodedEXTERNAL FUSELAGE SKIN CORRODED UNDER FWD AIRPHONE ANTENNA LOC BS 1390. ACCOMPLISHED A MAJOR REPAIR AT GSO. REPAIR PER REO G12355 AND EVA 71616. THIS REPAIR HAS RECEIVED ONLY 1ST STAGE APPROVAL PENDING FATIGUE AND DTA EVALUATION BY BOEING TO SHOW COMPLIANCESDR 2008UALA03190Wire · corrodedNR 2 PYLON HAS SEVERAL CORRODED WIRES AT GROUND STUD LOCATION SHEARED FROM GROUND. RE-TERMINATED WIRES IAW BSW PM 20-30-11.SDR 2008UALA03116Window · open1ST OFFICER'S WINDOW OPENED. RTFL. CHECK WINDOW OPERATION AND SEAL FOR DAMAGE AND WINDOW OPS NORMAL AND NO SEAL DEFECTS NOTED. CLOSED WINDOW.SDR 2008UALA03117Valve · openVIBRATION IN THE AFT CABIN FLOOR LED TO DIVERSION. WATER FILL VALVE AND PANEL LEFT OPEN SUSPECT ALL ISSUES ARE RELATED TO WATER FILL VENT VALVE NOT BEING CLOSED, BLEEDING HEAD PRESSURE. CAUSING WATER COMPRESSOR TO VIBRATE FLOOR AND CLUNKING WATER LINE DUE TOSDR 2008UALA03124Idg · failedRIGHT GENERATOR TRIPPED DURING CRUISE TWICE. NO SHOP DATA EXISTS FOR REPAIR. REPLACED IDG.SDR 2008UALA03142Light · inoperativeONE EMERGENCY LIGHT BULB DOES NOT ILLUMINATE ABOVE FWD RT OVERWING EXIT HATCH. LAMP INOP. RELAMPED LIGHT AT FWD RT OVERWING EXIT, OPS CHECK WAS OK.SDR 2008UALA03143Structure · crackedR2 DOOR UPPER HINGE ARM CUTOUT HAS A CRACK. ACCOMPLISHED MAJOR REPAIR AT GSO. REPAIRED FRAME IAW MM 52-11-87 AND SRM 51-40-02.SDR 2008UALA03144Structure · crackedL2 DOOR UPPER HINGE ARM CUTOUT HAS A CRACK. ACCOMPLISHED MAJOR REPAIR AT GSO. REPAIRED PER MM 52-11-87 AND SRM 51-40-02.SDR 2008UALA03070Bushing · corrodedAFT LT MLG AXLE HAS CORROSION ON AXLE SLEEVES. BUSHING FAILURE ON LT AFT TRUCK. TRUCK REMOVED AND BUSHINGS REPLACED, REINSTALLED AND ALL TESTS WERE GOOD.SDR 2008UALA03077Girt Bar · obstructedDOOR 1R HARD TO DISARM. DEBRIS UNDER GIRT BAR. REMOVED BOTTLE CAP FROM UNDER GIRT BAR. DOOR ARMING SYS OPS CHECKS OK.SDR 2008UALA03095Light · unsecureEXIT PATH LIGHTING STRIP IN REAR OF AIRCRAFT HAS COME LOOSE, LAST ROW IN COACH. RE-INSTALLED EEL LIGHTING, ALL OPS TESTS NORMAL.SDR 2008UALA03076Unknown · odorFLIGHT ATTENDANT REPORTS A "HOT PACK DUCTING" SMELL NEAR HER JUMP SEAT AT DOOR 2L. CHECK ELECTRICAL EQUIPMENT AROUND DOOR 2L FOR ANY BURNT AND ELECTRICAL SMELL. REMOVED AND INSPECTED AREA ABOVE DOOR 2L. NO ABNORMALITY FOUND AND NO BAD SMELL. CHECKED WITH PSDR 2008UALA03044Structure · chafedDOOR R4 DOUBLER AFT AND BELOW HANDLE BOX CHAFED. MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGE. FABRICATED AND INSTALLED DOUBLER REPAIR.SDR 2008UALA03049Crease Beam · corrodedMAIN CABIN CREASE BEAM AT STA 1000 LBL 71 IS CORRODED. MAJOR REPAIR ACCOMPLISHED, REMOVED AND REPLACED WEB.SDR DL75E080790Fcu · malfunctionedMAINTENANCE ATTEMPTING TO REPOSITION A/C STARTED NR 1 ENG AND TRIED TO ADVANCE THE THROTTLES WHEN THE ENGINE ROLLED BACK AND THEY HAD A TAIL PIPE FIRE WHICH THEY BLEW OUT. PERFORMED BORO, NO DAMAGE FOUND. REPLACED FCU AS PRECAUTIONARY. NO EPCS MESSAGES WERESDR 2008UALA03001Window · overheatedSTRONG ELECTRICAL ODOR IN FLT DECK, GOT WORSE DURING DESCENT. ODOR WAS COMING FROM NR 1 LT WINDSHIELD. WINDOW HEAT TERMINAL BLOCK MELTED. REPLACED NR 1 LT WINDOW, REPLACED WIND HEAT CONTROL UNIT FOR WINDOW 1L AS PRECAUTION.SDR 2008UALA03050Seal · brokenAFT FWD LOWER CEILING SLIDE RAFT ELT SEAL IS BROKEN. UNKNOWN DAMAGE. REPLACED ELT.SDR 2008UALA03043Floorbeam · corrodedCABIN FLOORBEAM AT STA 377.7, AT LBL 62 IS CORRRODED. ACCOMPLISHED MAJOR REPAIR AT GSO. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR IAW 53-00-98 FIG 825.SDR 2008UALA03045Structure · corrodedCABIN RT BETWEEN BS 1420 AND 1440 AT STR 17R CORROSION. ACCOMPLISHED MAJOR REPAIR AT GSO. REMOVED AND REPLACED WEB IAW SRM 53-60-13.SDR 2008UALA03046Web · corrodedCABIN RT BETWEEN STA 1400 AND 1420 AT STR 17R CORROSION. ACCOMPLISHED MAJOR REPAIR AT GSO. REMOVED AND REPLACED WEB IAW SRM 53-60-13.SDR 2008UALA03000Anti-Ice Valve · lockedLEFT ENG ANTI-ICE EICAS, LEFT ENG ANTI-ICE SWITCH OFF WITH VALVE LIGHT. NR 1 ENG ANTI ICE VALVE LOCKED IN THE OPEN POSITION. REPLACED NR 1 ENG AI VALVE, OPS OK.SDR 2008UALA03010Girt Bar · obstructedSLIDE LIGHT 2L ON W-DOOR DISARMED. DEBRIS UNDER GIRT BAR. REMOVED DEBRIS, PERFORMED OPS CHECKS, ALL NORMAL.SDR 2008UALA02994Girt Bar · dirtyTHE 3R WILL NOT ARM. CLEANED AND LUBED 3R GIRT BAR FITTING, OPS CHECKED NORMAL.SDR DL75E080773Fuel Control · malfunctionedAFTER LEFT ENGINE START THROTTLES ADV BUT ENGINE UNRESPONSIVE. LEFT ENG BLEED VALVE WOULD NOT OPEN. FIRE REPORTED TO BE FROM LEFT ENG TO ABOVE WING AND ENG SMOKING. FUEL CONTROL SW TO OFF AND NR 1 ENGINE FIRE BOTTLE DISCHARGED. NO ENG EXCEEDANCES ON MTC PASDR 2008UALA02971Flap · damagedCRACK HAS MIGRATED THRU THE RT INBOARD T/E FLAP. ALSO HAVE DELAM ON BOTH SIDES OF CRACK. COMPOSITE DELAMINATION. ACP INTERIM REPAIR PER SRM 57-53-01, PERMANENT REPAIR ACCOMPLISHED PER EVA-71598.SDR 2008UALA03011Hinge Fitting · crackedCRACK AT FWD UPPER L-1 DOOR CUTOUT AREA, INNER UPPER DOOR HINGE FITTING AT BS 337 AND STR 12L. REMOVED DAMAGED AREA REF R EO G-12344-3 AND SRM 51-20-01. THIS IS A TIME LIMITED REPAIR. FITTING P/N 141N8378-2 MUST BE REPLACED AT NEXT CK, NO LATER THAN 05-16-2SDR 2008UALA03012Connector · looseEXIT IDENTIFIER SIGNS - VERTICLE EXIT LIGHTS INOP DOOR 2L AND 2R, POSSIBLE BAD INVERTER. CONNECTOR WAS LOOSE RESEATED CONNECTOR. ALL LIGHTS OK.SDR 2008UALA02980Structure · damagedBS 1440 STR 26L HAS DAMAGE. ACCOMPLISHED MAJOR REPAIR AT GSO--RPR WAS RPL ON PTT#8002108 PER SRM 53 -00-07 RPR 5. THIS IS A RPR IN ZONE 1 AND IS CAT B RPR AND REQUIRES SUPPLEMENTAL INSPECTIONS STARTING AT 50,000 TOTAL FLIGHT CYCLES AND 12,000 FC THERE AFTER.SDR 2008UALA02950Intercostal · crackedINTERCOSTAL CRACKED AT BS 680 BETWEEN STR 11R AND STR 12R. MAJOR REPAIR ACCOMPLISHED: INSTALLED NEW INTERCOSTAL (P/N 143N8338U26).SDR 2008UALA02951Intercostal · crackedFWD OF L-2 DOOR AT STA 680 AND STR 12L, INTERCOSTAL CRACKED. MAJOR REPAIR ACCOMPLISHED: INSTALLED NEW INTERCOSTAL (P/N 143N8334U27).SDR 2008UALA02954Frame · dentedAFT PIT STA 1540 BETWEEN STR 25R AND 26R FRAME DENTED. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE. INSTALLED ANGLE REPAIR. INSTALLED NEW SPLICE PLATE & 2EA STR CLIPS (P/N 140N2001).SDR 2008UALA02930Girt Bar · faultyFWD END GRIT BAR FALLING OFF WHEN DOOR 4R OPENS. ARM AND DISARM FEELS STIFF AND BINDING. REMOVED LINER & SLIDE & LUBED ARM-DISARM MECHANISM, ADJUST FWD & AFT LIFTER WITH SLIDE INSTALLED, ALL OPS ARE NOW NORMAL.
Back to Pratt & Whitney PW2037