What was found
BS 1440 STR 26L HAS DAMAGE. ACCOMPLISHED MAJOR REPAIR AT GSO--RPR WAS RPL ON PTT#8002108 PER SRM 53 -00-07 RPR 5. THIS IS A RPR IN ZONE 1 AND IS CAT B RPR AND REQUIRES SUPPLEMENTAL INSPECTIONS STARTING AT 50,000 TOTAL FLIGHT CYCLES AND 12,000 FC THERE AFTER. INSPS ARE BOTH VISUAL AND NDT PER SRM 53-00-07 RPR 5 TABLE II. CURRENT PTC IS 20477. ON NR 46109 -INF- : REPAIR ACCMPLSHED PER SRM 50-00-07 TABLE II ZONE 1. REQUIRING REINSPECTION AT 50,000 CYCLES & REPEAT AT 12,000 CYCLES. THIS IS CAT B REPAIR. EC 50-5330-036SA -A CREATED TO ACCMPLSH INSP'S. DTA 03-184 WILL TRACK REPAIR.