SDR DL738070387Battery · inoperativeAFT EMERGENCY PATH LIGHT INOP. REPLACED POWER PACK FUSE, OPS CHK OK.SDR 2007UALA00025O-Ring · leakingLOW BOTTLE PRESSURE. FOUND A LEAKING FUSIBLE PLUG O-RING. REPLACED O-RING.SDR 2007UALA00023Light · inoperativeDOOR 2L SLIDE ARMED LIGHT WILL NOT ILLUMINATE. REPLACED LAMP.SDR 2007UALA00002Skin · puncturedPUNCTURE ON LEFT SIDE OF FUSELAGE 5.5 FT FWD OF DOOR 2L APPROX 6 INCHES ABOVE FLOORLINE. FULL DAMAGE MEASURES 3.5 INCHES WITH A PUNCTURE LIMIT OF ABOUT 2.75 INCHES. MAJOR REPAIR ACCOMPLISHED. THE SKIN WAS FOUND PUNCTURED BUT NO INTERNAL STRUCTURE WAS DAMAGED.SDR 2007UALA00003Skin · crackedEXTERNAL FUSELAGE SKIN DENT AT STA 756 AND STR 16L WAS FOUND CRACKED. A MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED DOUBLER REPAIR. REPEAT INSPECTIONS AT 37,500 CYCLES THRESHOLD.SDR 2007UALA00024Bottle · lowDOOR 1L PRESSURE BOTTLE OUT OF THE GREEN. REPLACED DOOR 1L SLIDE.SDR 2007UALA00033Slide · unserviceableDOOR 1L PRESSURE BOTTLE OUT OF GREEN.SDR 2007UALA00034Connector · burnedAPU BATTERY CONNECTOR FOUND BURNED. REPAIRED APU BATTERY CONNECTOR.SDR 2007UALA00035Light · inoperativeEEL STRIP LIGHT INOP BEYOND ROW 30. REPAIRED EEL LIGHTSTRIP.SDR 2006UALA02437Bottle · leakingLOW BOTTLE PRESSURE. BOTTLE LEAKING AROUND GLASS ON GAUGE. REPLACED GAUGESDR DL757061069Gearbox · damagedCREW OF FLT 455/27 REPORTED RT ENGINE OIL QTY LOSS AND PRESS DROP TO ZERO. ENGINE WAS SHUTDOWN BY SHUTDOWN CHECKLIST. REPLACED NR 2 ENGINE DUE TO GEARBOX DAMAGE.SDR 2006UALA02429Trim System · malfunctionedRUDDER TRIM INOP NEAR TOP OF CLIMB, THEN WORKED OK. REPLACED RUDDER TRIM FEEL CENTERING TRIM ACTUATOR.SDR 2006UALA02424Unknown · odorFWD CARGO PIT HAS A STRONG ELECTRICAL ODOR. TROUBLESHOT TO RT RECIRC FAN. GOT INOP LIGHT AND ASSOCIATED HORN WHEN RT RECIRC FAN IS IN COMMAND.SDR 2006UALA02427Trim System · malfunctionedUNCOMMANDED STAB TRIM DURING CLIMBOUT. NOSE DOWN TRIM WAS FELT. SAM HAD NO FAULT BALLS LATCHED. DETERMINED THE PROBLEM TO LEFT SAM. REPLACED LEFT SAM STABILIZER-TRIM /AILERON LOCKOUT UNIT.SDR 2006UALA02426Oxygen System · leakingFLIGHT DIVERTED TO ORD DUE TO A SUPPLEMENTAL OXYGEN LEAK. CREW REPORTS LOSS OF ALL O2, STATUS PAGE INDICATES LESS THAN 100PSI, CREW MASKS ARE NOT INFLATING. SUPPLEMENTAL DATA UPDATE FOUND CO PILOTS O2 STOWAGE BOX AND MASK LEAKING REPLACED O2 STOWAGE AND HOSE.SDR DLM88061047Coupling · damagedON TAXI IN, CREW FELT BRAKE LOCK UP. STOPPED AND CALLED FOR MAINTENANCE. UPON INSPECTION FOUND COUPLING ON NR 4 BRAKE DAMAGED. AIRCRAFT WAS TOWED TO BLAST FENCE AFTER THE BRAKE WAS BLEED. REPLACED COUPLING. OPERATED BRAKES, OPS CHKS NORMAL.SDR 2006UALA02425Line · brokenLT MAIN TANK TRANSFERRED INTO C TANK. L TANK TRANSFERRED APPROX 100 LBS EVERY 20 MINS INTO CTR TANK. SUPPLEMENTAL DATA UPDATE NOTED THAT TRANSFER IS CONSISTENT THROUGHOUT FLIGHT REALM AT APPROX 300 LBS PER HR AND EVENTUALLY CAUSED A CONSISTENT IMBALANCE BETWSDR DL757061046Engine · leakingSTRONG ODOR ON T/OFF ROLL WITH FORWARD LAV SMOKE DETECTOR CHIRPING, 10-15 SECONDS SMELL DISSIPATED BUT IS STILL DETECTABLE. MX INSPECTED ENGINE. FOUND EVIDENCE OF OIL LEAK FWD CLOSED ENGINE COWLING SERVICED LEFT ENGINE WITH 10 PINTS. PREPARED A/C FOR FERRY SDR DL757061042Engine · failedWINDING UP FOR T/O HEARD AUDIBLE ENGINE SURGE/STALL PASSENGERS OBSERVED FLAMES COMING FROM LEFT ENGINE. A/C RETURNED TO GATE. MTC INSPECTED TAIL PIPE FOUND BB SIZED DEBRIS. WILL NEED ENGINE CHANGE. REPLACED NR 1 ENG PER ROUTINE CARD DECK TRANS 6T103.SDR 2006UALA02369Skin · damagedLEFT FUSELAGE SKIN STA 600-640 STR 16L-17L IS DAMAGED. MAJOR REPAIR ACCOMPLISHED. REPAIRED LEFT FUSELAGE SKIN STA 600 REPAIR ACP STA 600-640 STRINGER - LOCATION OF REPAIR BS 602-642 STR 17L.SDR 2006UALA02374Battery Pack · inoperativeSIDEWALL EMERGENCY EXIT LIGHTS AT DOOR 2L, 2R AND OVERDOOR EMERGENCY LIGHT AT DOOR 2L INOP. REPLACED BATTERY PACK AT M733.SDR 2006UALA02372Duct · contaminatedRETURNED TO THE FIELD DUE TO SMOKE IN THE CABIN. AFTER RETURN TO GATE FOR SMOKE IN CABIN BEGAN CLEANING APU BLEED COMPONENTS AND DUCTS. FOUND AND CLEANED OIL IN DUCTS AS FAR AS APU FIRE BOTTLE ACCESS DOOR. NEED TO CHECK DUCTS THRU AFT BODY ACCESS DOOR FOR ASDR 2006UALA02352Light · inoperativeEEL LIGHTS INOP FROM MID LAV TO ROW 16. TROUBLESHOT INOPERATIVE EEL LIGHT, FOUND BAD CONNECTION - SECURED SAME.SDR 2006UALA02353Lamp · inoperativeEEL LIGHT INOP AT SEATS 10 DEF AND 34 DEF BULLNOSE. LAMP WAS FUSED. REPLACED LAMP.SDR 2006UALA02349Warning Message · illuminatedDUE TO MASTER WARNING ABORTED TAKEOFF AT 100 KNOTS. LEFT ENGINE GENERATOR DROPPED OFF LINE ON REJECTED TAKE-OFF. REPLACED IDG,SDR 2006UALA02351Lamp · inoperativeEXTERIOR EMERGENCY LIGHTS AT DOORS 4L AND 4R ARE INOPERATIVE. LAMP WAS FUSED. REPLACED LAMP.SDR 2006UALA02347Engine · malfunctionedRIGHT ENGINE OIL FILTER EICAS AT FL390 IN CRUISE. SHUT DOWN ENGINE. LANDED UNDER AMBER ALERT DUE TO LOSS OF OIL PRESSURE. NR 2 ENG ARRIVED WITH 8 QTS IN OIL TANK. FOUND MAIN OIL FILTER CONTAMINATED WITH SPALLED (FERROUS) METAL. ACCOMPLISHED ENGINE OIL SERSDR AALA20061217Eec · inoperativeDEN INFLIGHT T1454/08DEC SEA TO STL - RIGHT ENGINE PRIMARY AND SECONDARY ENGINE CONTROL ILLUMINATED DURING FLIGHT. LANDED DEN WITHOUT INCIDENT. REPLACED RIGHT ENGINE ELECTRONIC ENGINE CONTROL AND PERMANENT MAGNET ALTERNATOR. SYSTEM GROUND CHECKED NORMAL OPESDR 2006UALA02330Unknown · unknownDIVERTED TO ORD DUE TO A COCKPIT OXYGEN PRESSURE PROBLEM. THE PROBLEM COULD BE ATTRIBUTED TO A FAULTY O2 SYS SERVICING FILLER VALVE. REPLACED CREW O2 SYS SERVICING FILLER VALVE. REPLACED CAPTAIN'S AND OBSERVER'S O2 MASKS.ALSO REPLACED FIRST OFFICERS O2 STORSDR 2006UALA02333Warning Message · illuminatedRT ENGINE HIGH STAGE LIGHT ILLUMINATED AND RT ENGINE HIGH STAGE EICAS MSG IN CLIMB. REPLACED HIGH STAGE PILOT VALVE AND 14TH STAGE PILOT CONTROLLER.SDR 2006UALA02335Light · inoperativeSLIDE LIGHT ABOVE DR 1L INOP. LAMP WAS FUSED. REPLACED LAMP AND OPS CHECK NORMAL.SDR 2006UALA02336Warning Message · illuminatedNOSE AIR-GND DISAGREE MSG AND IN CRUISE AND HEARD A CLUNK NOISE IN NOSE GEAR AREA, SIMILAR TO NOSE GEAR COMING DOWN ON DOORS, GEAR HANDLE HAD ALREADY BEEN MOVED TO OFF EARLIER THAN WHEN THE NOISE OCCURRED PER CREW. SUPPLEMENTAL DATA UPDATE THE PROBLEM IS ATTRISDR 2006UALA02331Pump · unknownNR 1 ENGINE DRIVEN HYDRAULIC PUMP MAKES NO PRESSURE WITH AN EICAS MESSAGE L ENG DRIVEN PUMP. FOUND PUMP DRIVE SHAFT SEIZED. REPLACED LH RETURN FILTER AND CASE DRAIN FILTERS BECAUSE OF DEBRIS AND LH SYSTEM RETURN FILTER. RESERVICED HYDRAULIC SYSTEM.SDR 2006UALA02332Unknown · odorSMOKE ODOR IN ROW 22 INFLT AND ON TAXI IN. INSPECTED CABIN LIGHTING, GALLEYS, LAVS,PITS AND RAN PACKS ON GROUND NO ABNORMAL SMELL NOTED AT THIS TIME. ROOT CAUSE OF SMOKE COULD NOT BE DETERMINED AT THIS TIME.SDR 2006UALA02334Light · inoperativeAFT EEL LIGHT STRIP B INOP. TROUBLESHOT SYSTEM AND FOUND EPL CABLE DAMAGED. REPAIRED CABLE. LIGHT BAR CHECKS GOOD.SDR 2006UALA02293Skin · damagedEXTERNAL FUSELAGE SKIN AT STA 595-624, STR 12L-15L IS DAMAGED. MAJOR REPAIR ACCOMPLISHED. EXT FUSE SKIN REPAIR STA 595-624, STR 12L-15L HAS PREVIOUS REPAIR,NEW REPAIR INSTALLED. THIS REPAIR IS TIME LIMITED FOR 12 MONTHS.SDR DL757061002Line · looseLEFT ENGINE OIL PRESSURE DECREASED TO RED BAND. LEFT ENGINE OIL QTY ZERO. SHUTDOWN ENGINE PER QRH. LANDED BDA. FOUND NR 5 BEARING SCAVENGE LINE AT SCAVENGE PUMP LOOSE. RESTORED AND WIRE LOCKS OIL LINE. CARRIED OUT WINDMILL INSPECTION MAIN OIL FILTER AND SDR 2006UALA02323Hydraulic System · unknownLOSS OF THE LEFT HYDRAULIC SYSTEM. FOUND FLAP SLAT DEPRESSURIZATION MODULE IN LEFT WHEEL WELL WITH ONE UNION BROKEN. REPLACED FLAP-SLAT DEPRESSURIZATION VALVE. ALSO REPLACED L EDP CASE DRAIN FILTERS.SDR 2006UALA02324Hydraulic System · unknownLOST RT HYDRAULIC SYSTEM PRESSURE AND QUANTITY. DAMAGED RT SYSTEM HYD RETURN LINE WAS REPLACED.SDR 2006UALA02289Sensor · faultyDOOR 4 RIGHT ESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHT STAYS ON WITH DOOR DISARMED. CLEANED SENSOR AND REROUTE WIRE. LIGHTS OFF WITH DOOR DISARM.SDR 2006UALA02313Unknown · vibrationCREW REPORTED A SEVERE VIBRATION FROM TOUCHDOWN THROUGH ROLLOUT. FOUND NLG TORSION LINKS WORN BEYOND IN-SERVICE LIMITS. REPLACED LOWER NLG TORSION LINK ASSY.SDR 2006UALA02316O-Ring · damagedLOW BOTTLE. REPLACED BACKUP O-RING AND O-RING.SDR 2006UALA02287Light · brokenCABIN FLOOR EEL LIGHTS AT AFT LAV BROKEN. REPAIRED EEL LIGHT AT AFT LAV.SDR 2006UALA02288Light · brokenCABIN FLOOR EEL LIGHTS AT FWD ENTRY BROKEN. REPAIRED EEL LIGHTS AT FWD ENTRY.SDR 2006UALA02256O-Ring · leakingLOW BOTTLE PRESSURE. *S/D* LEAKAGE FOUND THROUGH GAUGE BACKUP O-RING AND THE SECOND O-RING. REPLACED BACKUP O-RING & SECOND O-RING.SDR 2006UALA02257Connector · failedEICAS MESSAGE MAIN BATTERY CHARGER DISPLAYED AND BATTERY DISCHARGE LIGHT EXTINGUISHED. ACCOMPLISHED CHRONIC REVIEW. FOUND DEFECTIVE PIN ON BATTERY CHARGER. REPLACED CHARGER, MSG ERASED AND BATTERY CHARGING OK. ALSO REPLACED THE MAIN BATTERY.SDR 2006UALA02251Eec · faultyEN ROUTE TO HNL THE NR 2 ENGINE SHUT DOWN. *S/D* RIGHT ENG FLAMEOUT AT FL400. SUCCESSFUL RELIGHT AT FL300. REPLACED EEC, FMU AND PMA. ACCOMPLISHED ENGINE LEAK AND ACCEL-DECEL CHECKS.SDR 2006UALA02238Slide · unwanted deployAIRCRAFT ARRIVED FOR C-CHECK MAINTENANCE AND IT WAS FOUND TO HAVE THE RT OVERWING SLIDE PARTIALLY DEPLOYED. SLIDE STILL IN COMPARTMENT. SLIDE REPLACED.SDR 2006UALA02239Unknown · odorCREW REPORTED ELECTRICAL ODOR IN CABIN NEAR DOOR 2L. USING EXT PWR IN HGR, ALL CABIN USERS ON, VIDEO ETC, CEILING & FLOOR AREA AROUND 2L, UNABLE TO DETECT ANY ELECT ODOR. CHECKED AREA ABOVE CLG, RAN APU AND ENGINES, ALL UTIL BUSSES, PACKS ETC, ENG, APU AIR &SDR 2006UALA02240Starter · faultyDURING ENGINE START SMOKE AND SPARKS WERE SEEN COMING FROM TAILPIPE OF NR 1 ENGINE. ON ENGINE START NOTIFIED BY GND CREW THAT SMOKE AND SPARKS WERE COMING FROM TAILPIPE OF NR 1 ENGINE. SPARKS CAUSED BY FAULTY STARTER. CHECKED INLET EXHAUST AND CHIP DETECTOR
Back to Pratt & Whitney PW2037