Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2004UALA00971Sensor · failedFORWARD EQUIPMENT SMOKE LIGHT ILLUMINATED. SUPPLEMENTAL DATA UPDATE, REPLACED FORWARD EQUIPMENT COOLING SMOKE SENSOR.SDR ASMF200410016Idg · failedCAPTAIN REJECTED TAKEOFF AT 70 KTS, RT GENERATOR WAS OUT OF ITS BAR AND DRIVE LIGHT TURNED ON. STARTED THE APU AND RESEATED THE SYSTEM RECOVERING THE GENERATOR. PERFORMED A SECOND ATTEMPT BUT AT 80 KTS REJECTED TAKEOFF DUE TO THE GENERATOR WAS OUT OF ITS BARSDR 2004UALA00969Skin · damagedAFT LWR FUSELAGE SKIN DAMAGED BETWEEN STA 1393 AND 1420. DAMAGE CAUSED BY CARGO LOADER. DENTS AND CREASES REMOVED FROM THE FUSELAGE SKIN IN TWO SECTIONS. ONE EXISTING SKIN DOUBLER WAS REMOVED AND REPLACED WITH LARGER DOUBLER TO INCORPORATE ONE SECTION OF NESDR 2004UALA00976Floorbeam · corrodedMAIN CABIN, STA 324, RBL 24-RBL 63, UPPER SURFACE OF FLOORBEAM CORRODED. INSTALLED REPAIR STRAP.SDR 2004UALA00965Doubler · corrodedAFT RT GALLEY AREA, STA 1700 BETWEEN RBL 42 AND RBL 56, DOUBLER PLATE CORRODED, (FLOOR DOUBLER). CORROSION DAMAGE FOUND. AFT DECK PLATE REPAIRED USING DOUBLER AND TRIPLER. PIN BEAM WAS REPLACED, AND A REPAIR TO THE BS 1701 FLOOR BEAM WEB ACCOMPLISHED FOR ACSDR 2004UALA00953Frame · dentedAFT PIT FRAME DENTED STA 1440, BETWEEN STR 25L AND 28L. *S/D* MAJOR REPAIR ACCOMPLISHED. TYPICAL DAMAGE TO THE AFT PIT FRAMES DUE TO CARGO LOADING. INSTALLED DOUBLER REPAIR.SDR 2004UALA00954Frame · dentedFWD PIT FRAME DENTED AT STA 580 STRINGER 25L. MAJOR REPAIR ACCOMPLISHED. TYPICAL DAMAGE TO THE FORWARD PIT FRAMES DUE TO CARGO LOADING. CUT OUT DAMAGE & INSTALLED NESTED ANGLE REPAIR OUTSIDE FRAME SECTION.SDR 2004UALA00955Skin · dentedLEFT FUSELAGE SKIN DENTED AT FRAME STA 761, BETWEEN STRINGERS 16L AND 15L. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED REPAIR DOUBLER - TRIPLER AND FILLERS.SDR 2004UALA00956Skin · dentedFUSELAGE SKIN AND DOUBLER DENTED AT STA 600 STR 19L IN 3 PLACES ON SKIN AND ONE ON DOUBLER. INSTALLED SKIN SPLICE REPAIR WITH DOUBLER, SPLICE DOUBLERS AND FILLERS.SDR 2004UALA00957Stringer · damagedDURING ACCOMPLISHMENT OF A SKIN SPLICE REPAIR FROM BS 590 TO BS 640, DAMAGE TO STR 16L WAS FOUND IN THIS AREA. SKIN AND STRINGER DAMAGE CAUSED BY TYPICAL JETWAY DAMAGE. NEW SECTION OF STRINGER WAS SPLICED IN FOR REPAIR PURPOSES.SDR 2004UALA00945Floorbeam · corrodedCABIN FLOORBEAM CAP AT BS 1640 RBL 51 TO RBL 60 IS CORRODED BEYOND ALLOWABLE LIMITS. MAJOR REPAIR ACCOMPLISHED. TYPICAL FLOOR STRUCTURE CORROSION. INSTALLED STRAP REPAIR.SDR 2004UALA00946Frame · dentedAFT PIT FRAME DENTED AT BS 1600 STR 26R. MAJOR REPAIR ACCOMPLISHED. TYPICAL AFT PIT FRAME DENTS FROM CARGO LOADING. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00947Frame · dentedAFT PIT FRAME UPPER FLANGE DENTED AT BS 1400 STR 26L. MAJOR REPAIR ACCOMPLISHED. TYPICAL AFT PIT FRAME DENTS FROM CARGO LOADING. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00948Frame · dentedAFT PIT FRAME UPPER FLANGE DENTED AT BS 1500 STR 26L. MAJOR REPAIR ACCOMPLISHED. TYPICAL AFT PIT FRAME DENTS FROM CARGO LOADING. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00949Frame · dentedAFT PIT FRAME UPPER FLANGE DENTED AT BS 1540 STR 26L. MAJOR REPAIR ACCOMPLISHED. TYPICAL AFT PIT FRAME DENTS FROM CARGO LOADING. INSTALLED J-ANGLE DOUBLER.SDR 2004UALA00950Frame · dentedAFT PIT FRAME UPPER FLANGE DENTED AT BS 1420 STR 26L. MAJOR REPAIR ACCOMPLISHED. TYPICAL AFT PIT FRAME DENT DAMAGE FROM CARGO LOADING. INSTALLED J-ANGLE DOUBLER.SDR 2004UALA00951Frame · dentedAFT PIT FRAME UPPER FLANGE DENTED AT BS 1600 STR 25L. MAJOR REPAIR ACCOMPLISHED. TYPICAL AFT PIT FRAME DENT DAMAGE FROM CARGO LOADING. INSTALLED J-ANGLE DOUBLER.SDR 2004UALA00952Spar · damagedDAMAGE FOUND AT WBL 265 WING FRONT SPAR AT THE DRY BAY ACCESS HOLE NUT PLATE ATTACHMENT. *S/D* MAJOR REPAIR ACCOMPLISHED. INSTALLED FREEZE PLUGS IN 3 HOLES AND INSTALLED NEW DOUBLER.SDR 2004UALA00944Frame · dentedAFT PIT FRAME DENTED BS 1500 STR 25L TO STR 26L. INSTALLED "J" ANGLE REPAIR.SDR 2004UALA00936Switch · shortedEMERGENCY LIGHT TEST SWITCH AT 4L DOOR IS INOPERATIVE, SHORTED S10295. *S/D* REPLACED SWITCH.SDR ASMF204410010Fan · odorDURING TRANSIT CHECK, CAPTAIN REPORTED STRONG ELECTRICAL CABLE BURNED ODOR. TECHNICAL PERSONNEL PERFORMED BITE TO APU CONTROL UNIT SHOWING MESSAGE CURRENT LAS RUN LOW OIL PRESS. APU WAS DEFERRED IAW MEL 49-11-1. BURNED ODOR IN PILOTS CABIN AND GALLEY. SMOKE INSDR 2004UALA00923Floorbeam · corrodedFLOORBEAM T-CAP AT BS 324, RBL 55 TO RBL 60 IS CORRODED. SPLICED IN A NEW PORTION OF THE FLOORBEAM.SDR 2004UALA00922Bear Strap · corrodedAFT PIT AT STA 1415 BETWEEN STRINGER 26R & 27R BEAR STRAP CORRODED. AREA FASTENER WERE REMOVED AND CORROSION WAS BLENDED AND REMOVED.SDR 2004UALA00916Frame · dentedAFT PIT STA 1420 ABOVE STR 26L FRAME DENTED. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED PIECE. FABRICATED AND INSTALLED SPLICE REPAIR.SDR 2004UALA00917Frame · dentedAFT PIT STA 1480 BETWEEN STR 25L AND 27L FRAME DENTED. MAJOR REPAIR ACCOMPLISHED. CUT OUT AREA OF DAMAGE. FABRICATED AND INSTALLED NEW SPLICE REPAIR.SDR 2004UALA00918Frame · dentedAFT PIT FRAME DENTED ON INBOARD FLANGE AT STA 1520 BETWEEN STR 25L AND 27L. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED PIECE. FABRICATED AND INSTALLED SPLICE REPAIR.SDR DL757040947Engine · meltedDURING T/O ROLL, PRIOR TO 60 KNT, AS POWER CAME UP TO T/O POWER, A LOUD BANG OCCURRED WITH LEFT ENGINE READING OIL PRESSURE ZERO, N1 ZERO. ACCOMPLISHED ABORT. REPLACING NUMBER ONE ENGINE.SDR 2004UALA00901Frame · dentedAFT PIT STA 1400, FRAME LT SIDE AT STR 27L IS DENTED. INSTALLED J-ANGLE DOUBLER REPAIR.SDR 2004UALA00895Light · will not testEEL LIGHTS INOP FROM ROW 31 TO AFT LAV. REPLACED POWER STRIP.SDR 2004UALA00899Floor Support · damagedFLOOR SUPPORT AT STATION 1708 TO 1720 AND AT STR 14L TO 16L IS DAMAGED. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2004UALA00900Frame · dentedAFT PIT STA 1440 FRAME LT SIDE AT STR 27L IS DENTED. MAJOR REPAIR ACCOMPLISHED. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00821Floorbeam · corrodedFLOORBEAM T-CAP AT BS 365 RBL 0 TO RBL 64 R CORRODED SEVERAL LOCATIONS. MAJOR REPAIR ACCOMPLISHED. INSTALLED ANGLE REPAIR.SDR 2004UALA00902Frame · dentedAFT CARGO PIT STA 1420 FRAME DENTED ON UPPER FLANGE BY STR 26L. *S/D* MAJOR REPAIR ACCOMPLISHED. INSTALLED J-ANGLE DOUBLER REPAIR.SDR 2004UALA00903Shear Web · corrodedCABIN CREASE BEAM SHEAR WEB AT LBL 70.5 FROM STA 960 TO 984 IS CORRODED. *S/D* MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW SHEAR WEB.SDR 2004UALA00966Crease Beam · corrodedCABIN CREASE BEAM SHEAR WEB AT RBL 70.5 FROM STA 960 TO 984 CORRODED. FABRICATED NEW SHEAR WEB.SDR 2004UALA00871Floorbeam · corrodedMAIN CABIN FLOORBEAM AT STA 1640 RBL 58 TOP RAIL CORRODED. FABRICATED & INSTALLED NESTED ANGLE REPAIR.SDR 2004UALA00872Crease Beam · corrodedMAIN CABIN BODY STATION 680 TO 740 LBL 63 FLOOR CREASE BEAM HAS SEVERAL AREAS OF CORROSION. REPLACED CREASE BEAM.SDR 2004UALA00873Shear Web · corrodedMAIN CABIN FLOOR STA 1681.8 SHEAR WEB CORRODED. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2004UALA00874Floorbeam · corrodedCABIN FLOORBEAM AT STA 325 BETWEEN RBL 44 AND RBL 58 CORRODED ON TOP CAP OF BEAM. FABRICATED & INSTALLED DOUBLER REPAIR. FABRICATED & INSTALLED ANGLE REPAIR DOUBLER.SDR 0401675815Line · chafedTHE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE WAS WITHIN ALLOWABLE LIMITS. REPAIRED PER EO 2822-01068-01. OPERATIONAL CHECK GOOD.SDR 0401685802Line · chafedTHE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE ALLOWABLE 0.004 INCH OF DAMAGE. REPLACED THE FUEL LINE. REPAIRED PER EO 2822-01068-01. OPERATIONASDR 0401695808Line · chafedTHE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE ALLOWABLE 0.004 INCH OF DAMAGE. REPLACED THE FUEL LINE. REPAIRED PER EO 2822-01068-01. OPERATIONASDR 0401705803Line · chafedTHE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE ALLOWABLE 0.004 INCH OF DAMAGE. REPLACED THE FUEL LINE. REPAIRED PER EO 2822-01068-01. OPERATIONASDR 0401715655Line · chafedTHE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 12N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE ALLOWABLE 0.004 INCH OF DAMAGE. REPLACED THE FUEL LINE. REPAIRED PER EO 2822-01068-01. OPERATIONALSDR 0401645811Line · chafedTHE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE ALLOWABLE 0.004 INCH OF DAMAGE. REPLACED THE FUEL LINE. REPAIRED PER EO 2822-01068-01. OPERATIONASDR 0401665802Line · chafedTHE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE ALLOWABLE 0.004 INCH OF DAMAGE. REPLACED THE FUEL LINE. REPAIRED PER EO 2822-01068-01. OPERATIONASDR 0401655809Line · chafedTHE SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE ALLOWABLE 0.004 INCH OF DAMAGE. REPLACED THE FUEL LINE. REPAIRED PER EO 2822-01068-01. OPERATIONAL CHESDR 2004UALA00848Odor · detectedLANDED UNDER AMBER DUE TO BURNING ODOR IN CABIN. CAUSE UNKNOWN. NO PRIOR HISTORY BEFORE OR SINCE THIS INCIDENT IN ATA 21 OR 36. ENGINE RUNS, PACK RUNS AND OTHER ELECTRICAL INSPECTIONS FAILED TO PRODUCE ANY DISCREPANCIES. NO PARTS REPLACED.SDR 2004UALA00849Smoke · detectedEICAS MESSAGE INDICATING SMOKE IN FORWARD EQUIPMENT COMPARTMENT. *S/D* CAUSE IS UNKNOWN. SINCE NO SMOKE SOURCE WAS FOUND (NO RELATED EQUIPMENT FAILURES), FWD EQUIPMENT COOLING FILTER WAS ALSO REPLACED.SDR 0401605657Fuel Line · chafedTHE FUEL SUPPLY TUBE IN THE RIGHT PYLON WAS FOUND TO BE CHAFING AGAINST THE PYLON SUPPORT STRUCTURE (P/N 112N4115-6). THE DAMAGE TO THE FUEL TUBE EXCEEDED THE ALLOWABLE 0.004 INCH OF DAMAGE. REPLACED THE FUEL LINE. REPAIRED PER EA 56-199804. OPERATIONAL CH
Back to Pratt & Whitney PW2037