What was found
AFT PIT FRAME UPPER FLANGE DENTED AT BS 1400 STR 26L. MAJOR REPAIR ACCOMPLISHED. TYPICAL AFT PIT FRAME DENTS FROM CARGO LOADING. INSTALLED J-ANGLE REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT FRAME UPPER FLANGE DENTED AT BS 1400 STR 26L. MAJOR REPAIR ACCOMPLISHED. TYPICAL AFT PIT FRAME DENTS FROM CARGO LOADING. INSTALLED J-ANGLE REPAIR.