SDR UALA2013041902711Hinge · lack of lubeL2 DOOR DOOR HINGE IS NOT CLOSING. LUBED HINGE, OPS NORMAL.SDR UALA2013041902712Control Unit · failedLEFT ELEV PCU EICAS WON'T CLEAR. HARD FAULT ELEVATOR PCU. FOUND OUTBOARD PCA AT FAULT. REMOVED AND REPLACED LT OB ELEVATOR.SDR UALA2013041802672Pressure Switch · faultyAFTER PUSH AND ENG START CENTER HYD PUMP 2 PRESS LIGHT ILLUM WITH SWITCH ON (DEFERRED PER SAMC). REPLACED PRESSURE SWITCH PUMP 2 CENTER, PER AMM, OPS CHECK OKAY.SDR UALA2013041802673Lens · unsecureEXIT ROW LIGHT LOOSE AT RIGHT SIDE OVERWING. SECURED LENSE. ACCOMPLISHED INSPECTION OF LENSE ASSY SECURITY. FOUND IN AIRWORTHY CONDITION.SDR UALA2013041802674Cover · looseFLOOR EEL STRIP CLEAR COVER IS LOOSE FROM ROW 30-35. SECURED EEL STRIP COVER.SDR UALA2013041802676Cap · missingEMERGENCY LIGHTS IN FIRST CLASS CABIN MISSING END CAPS. INSTALLED END CAPS.SDR UALA2013041802646Web · damagedBS 324 WEB HAS ELONGATED HOLES FROM RBL 30 - 62. REPLACED WEB AND ANGLES, AND REPAIRED FRAME IAW ECRA 5310-05720 AND REO-G16061 REV H. ACCOMNPLISHED HFEC IAW NTM PRT 6, 51-00-19, NO DEFECTS NOTED. MAJOR REPAIR.SDR UALA2013041802671Smoke Detector · inoperativeAFT LAVATORY SMOKE DETECTOR INOPERATIVE. REPLACED AFT SMOKE DETECTOR, OP CHECKED GOOD.SDR UALA2013041802681Light · missingEMERGENCY LIGHT STRIP MISSING. REPLACED EMERGENCY LIGHT ASSY. OPS CHECKED GOOD.SDR UALA2013041802664Girt Bar · out of adjustL1 DOOR UNABLE TO DISARM AND COULD NOT REMOVE BUSSEL. L1 SLIDE ARMED AND NOT PINNED. ACCOMPLISHED REMOVAL OF DOOR 1L SLIDE BUSSEL. REMOVED L1 DOOR SLIDE COVER. LUBRICATED PIN. OPERATED SMOOTHLY. CHECKED AND ADJUSTED DOOR, OPS CHECKED NORMAL. FEELS LIKE SDR UALA2013041802661Unknown · unknownFLT DECK WARMER THAN SELECTED WITH SWITCH ON & TEMP CONTROL IN AUTO. INOPERATIVE LIGHT EXISTING. 82' WITH FLT DECK CONTROLLER IN FULL COLD. PERFORMED FILTER AND SENSOR CLEANING. TEMP CONTROLLER LISTS NO FAULTS. BITE CHECKED GOOD. OPERATED LEFT PACK INSDR UALA2013041702632Light · disconnectedEEL STRIP FLEX LAMP SECTION DISCONNECTED AT SEAT 12ABC. REPORTED BY FLIGHT CREW. SECTION OF EEL LIGHT FLEX LAMP PER MM. OPS CHECKED NORMAL.SDR UALA2013041802668Cap · missingFLOOR PROX EMERGENCY ESCAPE LIGHTING TRACK END CAP AT 40C IS MISSING. REPLACED END CAP EEL TRACK AT 40C.SDR UALA2013041702618Floorbeam · corrodedCABIN FLOORBEAM UPPER TEE CORRODED BEYOND SRM LIMITS AT BS 324, RBL 42-63. REMOVED DAMAGE SECTION OF TEE FROM LBL 7 TO RBL 64. HFEC CUT-OUT & BOLT HOLE, NO CRACK FOUND. FABRICATED & INSTALLED REPAIR SPLICE & UPPER TEE FROM LBL 7 TO RBL 68 PER SRM 53-10-08 RSDR UALA2013041702619Skin · dentedFUSELAGE SKIN AT BS 590-661 BETWEEN S14-19L HAS MULTIPLE DENTS ON EXISTING REPIR DOUBLER. REMOVED EXISTING DOUBLER, HFEC CUTOUT & BOLT HOLES, NO CRACK FOUND. FAB & INSTALLED REPLACEMENT SKIN & REINFORCEMENT DOUBLER BETWEEN S13-20L PER ECRA 5330-04510.SDR UALA2013041802670Cap · missingEMERGENCY LIGHT END CAPS BELOW SEATS 1B, 8C, AND 12C ARE MISSING. REPLACED CAPS.SDR UALA2013041802639Filter · missingOVERWING EXIT EEL NOT RED OR ORANGE. INSTALLED EEL ORANGE FILTER LAMINATE AMM.SDR UALA2013041802669Oxygen Mask · leakingCAPTAIN'S OXYGEN MASK HAS A LEAK IN QUICK-DON STRAP. REPLACED OXYGEN MASK, OPS CHECKED GOODSDR UALA2013041602605Packing · leakingEVIDENCE OF HYDRAULIC LEAK AT THE RIGHT WING FLAP WELL AREA. FOUND NR 10 SPOILER PCU LEAK COMING FROM SMALL PLUG. FOUND LEAKING HYD PORT CAP, REPLACED PACKING.SDR UALA2013041802677Controller · failedAPU LOW DUCT PRESSURE LEVEL 1. PERFORMED BITE OF APU ECU REF MM 49-11-00 FIG 103. REPLACED NR 1 ENGINE REVERSE FLOW CHECK CONTROLLER, PER MM. RAN BOTH ENGINES ALL PARAMETERS ARE NORMAL DUCT PRESSURE.SDR UALA2013041802678Controller · failedRIGHT ENGINE BLEED PRESSURE REGULATING AND SHUTOFF VALVE INOPERATIVE CLOSED. APU PNEUMATIC ONLY INDICATES 15 PSI. APU SHUTOFF. REPLACED NR 1 ENGINE REVERSE FLOW CONTROLLER, OP CHECKED GOOD.SDR UALA2013041802675Oil System · low pressureRIGHT ENGINE LOW OIL PRESSURE, FLT DIVERTED. OIL QTY DROPPED TO "0" WITH OIL PRESSURE DROPPING AND TEMPERATURE RISING. REMOVED ENGINE.SDR UALA2013041502598Crease Beam · corrodedMAIN CABIN CREASE BEAM WEB UPPER SURFACE CORRODED AT BS 1130, LBL 68. REMOVED DAMAGED WEB, HFEC BOLT HOLES, NO CRACKS NOTED. FABRICATED & INSTALLED WEB REPAIR DOUBLER PER ECRA5340-01 504. MAJOR REPAIR.SDR UALA2013041602604Blade · nickedNR 1 ENGINE FAN BLADE NR 33 HAS A NICK ON LEADING EDGE 1 INCH FROM TIP. REPAIRED DAMAGE REF AMM.SDR UALA2013041502566Stiffener · dentedFORWARD CARGO DOOR, INTERIOR SIDE, LOWER EDGE, SECOND FROM AFT STIFFENER IS DENTED ON FLANGE. EVALUATED DENT AND FOUND TO BE OUT OF LIMITS IAW SRM 52-30-02. REMOVED AND REPLACED STIFFENER ANGLE IAW SRM 51-40-02 AND 51-40-05. MAJOR REPAIR.SDR UALA2013041502575Floor Support · corrodedFWD PASSENGER COMPARTMENT BS 316 RBL 9 FLOOR SUPPORT HAS UPPER SURFACE CORRODED AROUND FASTENER HOLES. REMOVED AND REPLACED FLOOR SUPPORT BS 316 RBL 9 IAW SRM 51-10-02 AND DWG 141N5160 REV A.SDR UALA2013041502579Probe · dislodgedNR 2 ENGINE HIGH OIL CONSUMPTION EXCEEDS LIMITS. FOUND CHIP DETECTOR DISLODGED FROM HOUSING DUE TO BROKEN TANGS ON RECEIVER. THIS CHIP DETECTOR IS FOR THE NR 1, 2, 3 BEARING PORTS. REPLACED 1, 2, AND 3 CHIP DETECTOR PROBE IAW 79-21-10. IDLE RAN ENGINE AND SDR UALA2013041502567Lock · missingR4 DOOR SLIDING BAR LOCK ASSY MISSING. INSTALLED BAR LOCK ASSY. OPS CHECKED GOOD IAW AMM 25-66-10.SDR UALA2013041502568Proximity Sensor · shortedDOOR SLIDE ARMED LIGHT WILL NOT COME ON. TROUBLESHOT AND FOUND WIRE 3682 GROUNDED AND FOUND FWD AND AFT R4 DOOR PROXIMITY SENSORS SHORTED. REMOVED & REPLACED R4 DOOR PROXIMITY SENSORS, OPS CHECKED GOOD IAW AMM 25-66-11 AND WDM 25-66-11.SDR UALA2013041502569Skin · dentedFUSELAGE SKIN DENTED BS 418 S17 TO 19R. REPAIRED SKIN IAW SRM 53-00-01. PERFORMED HFEC OF CUTOUT IAW NTM PART 6 51-00-19 NO DEFECT NOTED. MAJOR REPAIR.SDR UALA2013041502594Blade · nickedNR 2 ENGINE HAS A NICK IN FAN BLADE. BLENDED ONE FIRST STAGE BLADE ON NR 2 ENGINE REF MM.SDR UALA2013041502578Floor Panel · delaminatedFLOOR SPONGY BETWEEN ROWS 9 AND 10. INSTALLED INTERM REPAIR PER AMM. LARGE AREA DELAMINATION. REPLACE PANEL BY NEXT C CHECK. DELAMINATION AREA EXTENDS BETWEEN CENTER AISLE ROWS 9-11.SDR UALA2013041802679Cover · crackedAT 14C EEL LIGHT TRACK COVER CRACKED. REPLACED EEL LIGHT COVER AT 14C.SDR UALA2013041502553Skin · dentedEXTERIOR BOTTOM RIGHT R2 DOOR DENT AND FRESH PAINT MISSING DOWN TO BARE METAL IN L SHAPE. INSTALLED INTERIM REPAIR AT BS 1617 JUST ABOVE S18R PER ECRA 5330-04512.SDR UALA2013041502554Skin · dentedEXTERIOR FUSELAGE SKIN DENTED AT S 1622 ABOVE S19R. EVALUATED DENT PER SRM 53-00-01, FIG 101 AND FOUND TO BE WITHIN LIMITS. DENT HFEC INSPECTED, NO CRACKS. INSTALLED INTERIM REPAIR IAW ECRA 5330-04512.SDR UALA2013041502589Skin · dentedBOTTOM R2 DOOR DENTED AND FRESH PAINT MISSING DOWN TO BARE METAL IN SHAPE L. INSTALLED INTERIM REPAIR AT BS 1617 JUST ABOVE S18R PER ECRA 5330-04512.SDR UALA2013041502551Channel · corrodedFWD PASSENGER COMPARTMENT BS 310.5 TO 332.5 RBL 32 HAS UPPER CHANNEL SURFACE CORRODED. CORROSION MATERIAL LOSS WAS 100%. REMOVED AND REPLACED UPPER CHANNEL IAW SRM 51-40-02, SRM 53-00-04 AND DWG141N5160. MAJOR REPAIRSDR UALA2013041502564Ballast · inoperativeAFT LAVATORY FLUORESCENT LIGHT INOPERATIVE. REPLACED BALLAST. AFT LAVATORY LIGHTS OPERATE NORMALLY.SDR UALA2013041502534Skin · dentedFA SEVEN INCH DENT AFT OF L1 DOOR S16L AND BS 400. REPAIRED DENT IAW ECRA 536 1-01053.SDR UALA2013041502563Wire · brokenRIGHT LANDING GEAR GREEN LIGHT HALF BURNED OUT. FOUND L399 RT HALF INOP. REPLACED LANDING CARD AT P51 PANEL MR31510-9 OFF AND 123 ON. FOUND BROKEN WIRE AT L399. WHILE REMOVING P3-1 PANEL TO REPAIR WIRE LOST RIGHT HALF OF LEFT, NOSE, GEAR AND DOORS. NEEDS SDR UALA2013041302530Floor Panel · damagedAISLE FLOOR PANEL SPONGY AT ROW 35. DELAMINATION IS ABOUT 1FT BY 1FT UP TO AFT EDGE OF PANEL. REMOVED AND INSTALLED NEW FLOOR PANEL IAW AMM.SDR UALA2013041302528Floorbeam · corrodedMAIN CABIN FLOORBEAM UPPER TEE AT BS 365, BL 0-RBL 64, WL 208 CORRODED. HFEC WEB CUT-OUT & BOLT HOLES, NO DEFECT NOTE. FABRICATED & INSTALLED UPPER TEE ANGLE REPAIR IAW ECRA5310-05536. MAJOR REPAIR.SDR UALA2013041502545Floor Panel · damagedAFT CARGO FLOOR HAS A HOLE. FOUND HOLE ON RT SIDE FRAME, 10 FEET AFT OF CARGO DOOR. HOLE MEASURES 3-4 INCHES LONG BY 1-2 INCHES WIDE. PERFORMED INTERIM REPAIR REF PER GNMM 1-0-1-102.SDR DALA1309056802Skin · dentedLT SIDE VERTICAL STAB DENTED 18 INCHES. REMOVED DAMAGE AND PREPARED AREA FOR REPAIR IAW SRM 51-70-10. INSTALLED REPAIR IAW SRM 51-70-10 942294 RESTORED FINISH IAW MM 51-21.SDR UALA2013041102466Smoke Detector · inoperativeEICAS STATUS MESSAGE FWD CARGO SMOKE DETECTOR NR 1. FWD CARGO NR 1 SMOKE DETECTOR INOPERATIVE. REPLACED NR 1 SMOKE DETECTOR.SDR UALA2013041102482Floor Panel · damagedSINKHOLE IN FLOOR PANEL AT ROW 32. INSTALLED OVERLAY PANEL PER MM. FLOOR PANEL REPLACED.SDR UALA2013041102484Connector · damagedSTAB TRIM LIGHT AND UPPER EICAS ILLUMINATED WHEN STAB MOVED. STAB TRIM SHUTOFF LEFT CIRCUIT BREAKER ON P-11 WILL NOT RESET. FOUND D1851 CONNECTOR INSULATION DAMAGED. REPLACED CONNECTOR D1851 PER WDM 27-41-11.SDR UALA2013041102488Smoke Goggles · missingSMOKE GOGGLES MISSING AT OBSERVERS SEAT. INSTALLED SERVICEABLE SMOKE GOGGLES.SDR UALA2013041202512Lanyard · out of positionR1 DOOR SLIDE LANYARD HANGING OUT OF DOOR. INSTALLED DOOR LANYARD IAW AMM.SDR UALA2013041202513Connector · contaminatedAPU IS INOPERATIVE DUE TO NO FIRE PROTECTION. FOUND CONNECTOR ON BOTTLE OILY. CLEANED CONNECTOR AND OPS CHECKED OK.
Back to Pratt & Whitney PW2037