Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012051102757Lamp · inoperativeDOOR 2L ARMED, BUT SLIDE ARM LIGHT IS OFF, PER CREW. RELAMPED SLIDE ARMED LIGHT. OPS GOOD.SDR UALA2012051002698Roller · brokenL1 DOOR FWD UPPER CRANK ROLLER BROKEN. REPLACED BEARING, DOOR OPS NORMAL.SDR UALA2012051102739Bleed Valve · faultyRIGHT ENGINE AMBER LIGHT, RETURNED TO FIELD. REPLACED HIGH STAGE BLEED VALVE AND PILOT PER MM.SDR UALA2012051002699Pump · leakingLOST ALL HYD QUANTITY ON LEFT SIDE ON SHORT FINAL. LT ENGINE PUMP LOW PRESSURE LIGHT FLICKERED FOLLOWED BY LT SYSTEM LOW PRESSURE LIGHT. BOTH LT ENGINE AND LT ACMP SHUTOFF. AFTER LANDING LT REVERSER DID NOT OPERATE BUT STEERING OPS NORMAL. LT QTY AFTER PARSDR UALA2012051002702Attach Fitting · brokenLEFT MAIN GEAR RETRACT ACTUATOR FITTING BROKEN. REPLACED FITTING IAW MM 32-32-01, FIG 401.SDR UALA2012051002703Line · leakingAFTER GEAR EXTESION LT HYD QTY EICAS AND FLUID QUANTITY DECREASED TOWARD ZERO. REPAIRED AND REPLACED HYD PRESSURE RETRACT ACTUATOR LINE, REF AMM 32-32-01.SDR UALA2012051002701Floorbeam · corrodedFLOORBEAM BS 1660 TOP SURFACE HAS CORROSION FROM BL 0 TO LBL 38. FLOORBEAM REPAIRED PER SRM 53-00-51 REPAIR 3.SDR UALA2012051102759Placard · unsecureEXIT ROW PLACARD IN ROW 20 DEF FELL OFF. SECURED EXIT ROW SIGN.SDR UALA2012050802657Pump · failedRT ENG HYD PUMP OVERHEAT LIGHT ILLUMINATED ON TAKEOFF. CREW SELECTED ENG PUMP SWITCH TO OFF AND LIGHT WENT OUT. FLIGHT DIVERTED. REPLACED RT ENG HYD PUMP ASSY PER AMM. ALSO REPLACED RH SYS CASE DRAIN AND PRESS FILTERS PER AMM. NO LEAKS NOTED.SDR UALA2012050802655Structure · damagedLEFT TRAILING EDGE INBOARD FLAP WAS REMOVED FOR ELONGATED HOLE UNDER INBOARD BRACKET ON AFT FAIRING FOR OUTBOARD TRACK. REPAIRED IAW AVO1291.SDR UALA2012051002704Snubber · faultyFORWARD AND AFT LIFE RAFT COMPARTMENT GAS CARTRIDGE ARE FLAT CAUSING DOORS TO OPEN QUICKLY WITHOUT SNUBBING ACTION. SAFETY ISSUE, REMOVED AND REPLACED 4 FWD AND AFT RAFT COMPARTMENT SNUBBERS IAW AMM 25-22-03.SDR UALA2012050802673Shear Tie · corrodedCORROSION ON SHEAR TIE AT BS 1520 BETWEEN STRINGERS 29L-28L. REMOVED CORROSION AND FOUND SHEAR TIE TO BE OUT OF LIMITS. FABRICATED AND INSTALLED NEW SHEAR TIE.SDR UALA2012051002700Fire Warning · false activationAFT CARGO FIRE WARNING ON, NO FIRE. DOWN POWERED AIRCRAFT MESSAGED ERASED. TESTED SYSTEM PER AMM 26-16-00.SDR UALA2012050802672Floorbeam · corrodedBS 310 FLOORBEAM HAS CORROSION AT RBL 40. FABRICATED AND INSTALLED ANGLE AND STRAP REPAIR IN REF TO ECRA 5310-05501.SDR UALA2012050402640Duct · leakingUNIDENTIFIABLE NOISE IN FIRST CLASS CABIN. MULTIPLE LEAKS IN CTR DISTRIBUTION DUCT IN AREA OF UPPER BEACON. LOUD VIBRATION WITH DUCTS PRESSURIZED AT UPPER BEACON ACCESS POINT. EXTERNALLY SEALED AFFECTED AREAS OF OVERHEAD CENTER DISTRIBUTION DUCT. NO FURTHESDR UALA2012050402641Switch · faultyLEFT ELECTRICAL HYD SWITCH DOES NOT SHUT SYSTEM OFF. REPLACED LT HYD PUMP SWITCH CAP AND MASTER MODULE. PRESSURE LIGHT IS NOW SOLID AND PUMP OPERATION AND INDICATIONS ARE ALL CORRECT.SDR UALA2012051002705Unknown · odorODOR LIKE OVERHEATED PACK FOR 2 MINUTES AFTER TAKEOFF. PACK OPERATIONS WAS NORMAL ON BOTH GROUND AND AFTER TAKEOFF. PER ECS PAGE, ALL ZONE TEMPS NORMAL EXCEPT AFT CABIN WHICH WAS 80 ON THE GROUND AND THEN COOLED TO 71 AFTER TAKEOFF. RAN PACKS, NO OVERHEAT FSDR UALA2012050402638Lamp · inoperativeR4 DOOR SLIDE ARMED LIGHT OVER DOOR NOT ILLUMINATED. RELAMPED, OPS CHECKS OKAY.SDR UALA2012050402639Start Valve · inoperativeRT ENGINE START VALVE DID NOT OPEN DURING START. START VALVE LIGHT OK. START VALVE INOPERATIVE. REPLACED STARTER VALVE ASSY.SDR UALA2012050402644Pump · failedCREW REPORTS LEFT ENG HYD PUMP FAILED AND LEFT SYSTEM FLUID QTY IS AT 65 PERCENT. REPLACED LEFT ENGINE DRIVEN PUMP PER AMM.SDR UALA2012050302612Skin · damagedUPPER CROWN, AT STR 6 RT, 24 TO 40 INCHES AFT OF DOOR 1 RT, 2 LIGHTNING STRIKES IN SKIN. REPAIRED IAW SRM 53-00- 01, REPAIR 6, SECT II, ITEM 5.SDR UALA2012050402625Shear Tie · corrodedCORROSION ON SHEAR TIE AT BS 1520 BETWEEN STRINGERS 29L-28L. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND FOUND SHEAR TIE TO BE OUT OF LIMITS. FABRICATED AND INSTALLED NEW SHEAR TIE PER SRM 51-40-02.SDR UALA2012050402626Floorbeam · corrodedFLOORBEAM CORRODED STA 365 CENTERLINE TO RBL 48. PERFORMED A PARTIAL CHORD REPLACEMENT REF ECRA 5310-05496.SDR UALA2012050302616Lamp · inoperativeINOPERATIVE EMERGENCY EVAC LIGHTS AT DOOR 1L AND 2L. RELAMPED, OP CHECKED GOOD.SDR UALA2012050402643Connector · damagedLEFT ENGINE ON GND UNABLE TO MANUALLY SELECT EEC SECONDARY CHANNEL FROM SECONDARY SELECT SWITCH AT P61 PANEL. FOUND CONTACT Y1 PUSHED BACK ON CONNECTOR D5860. SECURED CONTACT IN CONNECTOR. SECONDARY CONTROL MESSAGE SHOWS AND SEC CHANNEL SELECTED ON EPCS PAGSDR UALA2012050402645Unknown · smokeACRID ODOR IN COCKPIT, FLIGHT DIVERTED. TURNED OFF WEATHER RADAR, ODOR DISSIPATED. AFTER A SHORT TIME A HAZE APPEARED IN THE COCKPIT WITH THE REPORTED SMOKE ORIGINATING FROM THE AREA JUST BELOW THE FIRST OFFICER'S INSTRUMENT SOURCE SELECTOR SWITCHES.SDR UALA2012050402648Hinge Fitting · wornLEFT MLG DOOR AFT ATTACH FITTING BOLT HOLES WORN. OVERSIZED HOLES, HOLE FINAL SIZE IS .437,EM WITHIN LIMITS PER AVO 1283. REWORKED LT MLG DOOR AFT HINGE FITTING COUNTERSUNK HOLES REF AVO 1283 AND ECRA 5340- 01464 AND INSTALLED FITTING WITH OVERSIZED HARDWARESDR UALA2012050202606Shear Tie · corrodedCORROSION ON SHEAR TIE AT BS 1580 BETWEEN STRINGERS 27-28L. REMOVED FABRICATED AND INSTALLED SHEAR TIE IAW SRM 51-10-02 AND SRM 51-30-01.SDR UALA2012050302610Floorbeam · corrodedSTA 365 FLOORBEAM CORRODED BELOW-RBL 70. FABRICATED AND INSTALLED TEE CHORD, 2 ANGLES, AND 2 STRAPS. FABRICATED 4 CLIPS, AND 2 ANGLES, INSTALLED CLIPS & ANGLES ALONG WITH 2 PREVIOUSLY REMOVED INTERCOSTALS PER SRM'S 51-40-02 AND 53-00-51 FIG 201.SDR UALA2012050202587Radar · no testWEATHER RADAR FAILS TEST. REPLACED WEATHER RADAR ASSY PER MM34-43-05. OPS CHECKED GOOD.SDR UALA2012050102579Bolt · looseNOSE GEAR HAS BAD VIBRATION WHEN LIFTED OFF THE GROUND DURING TAKEOFF FELT UNBALANCED. CREW REPORTS VIOLENT SHAKING THRU OUT CABIN AFTER TAKE OFF. FOUND BOLT ON NLG GEAR DOOR ASSY WORN. REPLACED BOLT.SDR UALA2012050202586Transceiver · odorDIVERTED FOR AN ODOR IN THE CABIN AND SMOKE IN THE COCKPIT. FOUND ELECRICAL ODOR COMING FROM WEATHER RADAR RT UNIT. REPLACED AND TESTED OK REF MM.SDR UALA2012050402642Eec · faultyLEFT ENGINE SEC CONT MESSAGE. CREW SHUTDOWN ENG, CLEARED MESSAGE AND PERFORMED RESTART. AT STARTER CUTOUT LT ENG SEC CONT MESSAGE RETURNED. PER FIM EPCS TROUBLESHOT FCU RESISTANCE, CHECKED OK. REPLACED NR 1 EEC PER MM. MESSAGE WENT AWAY AND REPLACED RELAY SDR UALA2012043002543Oxygen Bottle · usedSMALL O2 BOTTLE USED FROM ROW 20ABC, REPLACED O2 ROW 20A.SDR UALA2012043002544Oxygen Bottle · usedLARGE O2 BOTTLE 5AB USED, REPLACED O2 ROW 5A.SDR UALA2012043002549Floorbeam · corrodedFLOORBEAM BS 324 RBL 42-70 CORRODED. CUT-OUT BS 324 FLOORBEAM FROM LBL10 - RBL70. ACCOMPLISHED NDT OF TRIMMED EDGE AND EXISTING HOLES COMMON TO REPAIR. NO CRACKS FOUND. FABRICATED AND INSTALLED REPAIR ANGLES, STRAPS AND REPAIR REF EA PT57-53-002 AND ECRA 5SDR UALA2012043002550Skin · damagedR4 DOOR DAMAGED, DENTED, AND CRACKED ON INNER SKIN AT LOWER CENTER ACCESS CUT OUT. REMOVED DAMAGE PERFORMED NDT AND NO CRACKS FOUND. FABRICATED DOUBLER REPAIR AND INSTALLED PER EA57-52-001 AND ECRA 5210-02298.SDR UALA2012043002548Skin · dentedFOUND DENT ON LT FUSELAGE APPROX 7 FT FWD OF DOOR 2L AND 2 FT BELOW WINDOW. DENT MEASURES APPROX 4 IN LENGTH BY 4 WIDTH. .062 DEPTH BY- 113877 :DENT OK PER SRM 53-00-01 PG 104. NO PULLED FASTENERS OR STRINGER DAMGE NOTED. ACCOMPLISHED SKIN AND STRINGER REPSDR UALA2012043002542Floorbeam · corrodedSTA 1661 FLOORBEAM HAS CORROSION LBL 33 TO RBL 21. CUT OUT DAMAGED AREA AND INSTALLED REPAIR REF SRM 53-00-51 RPR 3. MAJOR REPAIRSDR UALA2012043002551Floorbeam · corrodedAFT CABIN AREA BS 1661 LBL 15 FLOORBEAM CORRODED. CUT-OUT CORRODED AREA REF SRM 53-00-52 FIG 201 REPAIR NR 3. FABRICATED AND INSTALLED UPPER CHORD ANGLES AND STRAP REPAIR REF SRM53-00-51 FIG 201 REPAIR NR 3.SDR UALA2012043002546Girt Bar · lack of lubeR4 DOOR IS CLOSED BUT WILL NOT ARM, ADJUSTED AND LUBED GIRT BAR MECHANISM PER AMM 52-11-25. SLIDE ARMS AND DISARMS NORMALLY.SDR FDEA201204271657Skin · crackedNR 2 NACELLE SKIN UPPER EDGE AT AFT HINGE IS CRACKED. CUT OUT DAMAGED AREA AND INSTALLED FILLER AND REPAIR DOUBLER IAW EA F-7111-159923. MAJOR REPAIR.SDR UALA2012042702524Oil System · leakingOIL LEAK COMING OUT OF 2.5 BLEED AND DIRTY SOCK ODOR IN COCKPIT. REPLACE NR 1 ENGINE PER MM.SDR UALA2012042702509Skin · puncturedFUSELAGE PUNCTURED BOTTOM LEFT APPROXIMATELY BS 640 AND WL 144. HOLE IS APPROX 1 INCH BY 1 INCH. HOLE LOCATION IS AT BS STA 668 AND ABOVE STRINGER 26L. ACCOMPLISHED PERMANENT REPAIR IN ACCORDANCE WITH EG DOCUMENT.SDR UALA2012042702525Windshield · crackedCO-PILOTS FRONT WINDSHIELD MULTIPLE CRACKS. INSTALLED NEW WINDSHIELD PER AMM.SDR UALA2012043002545Circuit Card · faultyPOWER TRANSFER EICAS MESSAGE. REPLACED CIRCUIT CARD S10246, PTU MESSAGE CLEARED, OP CHECKED OKAY.SDR UALA2012042702507Skin · puncturedAPPROXIMATELY 1 INCH BY 1 INCH PUNCTURE AT STA 1350 BETWEEN STR 20 AND 21 FROM CONTACT WITH LIFT. SHOULD ALSO READ LEFT SIDE OF ACFT. STOP DRILLED CRACKS PER SRM. OK FOR NON REVENUE FLT TO REPAIR STATION WITH MAX CABIN DIFFERENTIAL PRESSURE LIMITED TO 6.0 PSDR UALA2012042702508Girt Bar · obstructedDOOR 4R SLIDE ARMED LIGHT NOT ILLUMINATED WITH DOOR ARMED STOWED ESCAPE SLIDE LANYARD IN SKIRT PER AMM. DOOR 4R SLIDE IS ENGAGING FLOOR FITTINGS NORMALLY.SDR UALA2012042702510Door · damagedLAVATORY OCCUPIED LIGHT INOPERATIVE. LIGHT DID NOT ILLUMINATE BECAUSE OF DOOR MALFUNCTION. CORRECTED DOOR PROBLEM, OCCUPIED LIGHT CHECKED GOOD.SDR UALA2012042502494Breather · leakingFOUND DEOILER BREATHER LEAKING DURING RUN. ADDED 9 QTS OF OIL NR 1 ENGINE. PERFORMED IDLE LEAK CHECK, CHECKED CHIP DETECTORS, ACCOMPLISHED VISUAL CHECK OF ENGINE. ACCOMPLISHED BAG AND BREATHER THAN RAN AT 80 PERCENT N1, NO LEAKS.
Back to Pratt & Whitney PW2037