What was found
AFT CABIN AREA BS 1661 LBL 15 FLOORBEAM CORRODED. CUT-OUT CORRODED AREA REF SRM 53-00-52 FIG 201 REPAIR NR 3. FABRICATED AND INSTALLED UPPER CHORD ANGLES AND STRAP REPAIR REF SRM53-00-51 FIG 201 REPAIR NR 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN AREA BS 1661 LBL 15 FLOORBEAM CORRODED. CUT-OUT CORRODED AREA REF SRM 53-00-52 FIG 201 REPAIR NR 3. FABRICATED AND INSTALLED UPPER CHORD ANGLES AND STRAP REPAIR REF SRM53-00-51 FIG 201 REPAIR NR 3.