Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012040502127Sensor · faultedAPU HAS LOW BLEED AIR AT ENGINE START AND SURGING. REPLACED SURGE VALVE AND LOAD COMPRESSOR INLET TEMP SENSOR PER MM. OPERATED NORMAL ON ENGINE START.SDR UALA2012040202028Light · damagedEMERGENCY ESCAPE LIGHT END CAPS MISSING 6B, 8C & 1L. REPLACED MISSING END CAPS AT 1L, 6B & 8C WITH (PCN .SDR UALA2012040202037Clutch · failedSPOILERS DEPLOY 1/2 WAY ON LANDING. FOUND BUSHING FOR SPEEDBRAKE ACTUATOR MOUNTING BOLT MISSING. INSTALLED BUSHING. PERFORMED AUTO SPEED BRAKE TEST. CHECK FAILED PER AMM. SPEED BRAKE LEVER VERY HARD TO MOVE OUT OF ARMED POSITION. NO BACK CLUTCH REPLACED SDR UALA2012040202007Skin · dentedLOWER FUSELAGE SKIN BS 1618 S18R AND S19R DENTED. ACCOMPLISHED INTERIM REPAIR PER ECRA 5330-04224. MAJOR REPAIRSDR UALA2012040202043Light · inoperativeCREW REPORTED EMERGENCY LIGHTS INOPERATIVE ROW 8 TO 11. REPLACED FAULTY LIGHT, OPS SATISFACTORY.SDR UALA2012040202004Skin · corrodedLOWER FUSELAGE SKIN BULGING AT BS 1714 TO 1719 LBL-16. INSTALLED REPLACEMENT SKIN PANEL BS 1621-1720 S-26L TO S-26R. ALL WORK PERFORMED PER ECRA 5330-04223 AND SRM 51-40-02.SDR UALA2012040202006Skin · damagedSKIN DAMAGED, REPAIRED AT DOOR 1R AT LWR DOOR CUTOUT PER ECRA 5330-04221.SDR UALA2012040202033Skin · damagedSKIN DAMAGED. REPAIRED AT BS 1620 S18-19R PER ECRA 5330-04224.SDR UALA2012032901978Skin · damagedFUSELAGE SKIN AND STRINGER DAMAGED STA 1720-1740 AT S-15AL REF SCAL LP 9963950, 9964047. MAJOR REPAIR ACCOMPLISHED: INSTALLED FUSELAGE SKIN AND STRINGER REPAIRS IN REF TO SCAL ECRA 5300-01411 SEE SCAL LP 9963950, 9964047 FOR ALL REPAIR WORK PERFORMED.SDR UALA2012033001994Clamp · unsecureLOUD AIR RUSHING NOISE AND DENT IN CEILING PANEL ABOVE SEAT 3E AND 4E. RMV'D CEILING PANELS OVER SEAT 3E AND 4E. INSPECTED ENTIRE AREA. FOUND NO BROKEN AIR DUCTS, HOWEVER, FOUND 4 UNSECURED WIRE CLAMPS AND 1 UNSECURED CONNECTOR CLAMP. SECURED ALL CLAMPS ANDSDR UALA2012033002002Engine · making metalNR 2 ENGINE COMPRESSOR STALL IN FLIGHT. ENG RECOVERED AND CONTINUED OPERATING. IMMEDIATE PRECEDING STALL, ENGINE POWER WAS STEADY HIGH POWER (CRUISE OR CLIMB). CREW COMMENTS: DURING CRUISE AT FL380 EPR ROLLED BACK TO ZERO FOLLOWED CHECKLIST ENGINE RECOVERESDR UALA2012033001993Sensor · faultedCREW REPORTS AFTER ENGINE START RT ENG PROBE HEAT EICAS MSG DISPLAYED. DEFERRED PER SAMC. REPLACED RIGHT ENG P2-T2 SENSOR AND ACCOMPLISHED OPS CHECK, ALL TESTS PASS.SDR UALA2012040202055Pressure Switch · defectiveSTATUS MESSAGE; FLAP ISOLATION VALVE AND ELEVATOR LT HYD PRESSURE WON'T CLEAR. REPLACED EDP PRESSURE SWITCH PER AMM. ERASED MESSAGES, OPERATED SYSTEMS, NO MESSAGES.SDR UALA2012033001995Spoiler · malfunctionedON LEFT WING FLOATING SPOILER; SECOND FROM FUSELAGE AS OBSERVED BY CAPTAIN IN THE CABIN. NO ABNORMAL FEEL BY PILOT FLYING REGARDING THE FLOATING SPOILER.SDR UALA2012032901974Heater · failedRT AUX 1 PITOT FAILED PROBE HEAT TEST ON P61 PANEL-NO HEAT FROM PROBE NOTED. REPLACE PROBE.SDR UALA2012033001999Arm · out of adjustMAIN ENTRY DOOR IS OUT OF RIG. MADE INITIAL ADJUSTMENT TO GUIDE ARM. ALL 4 LATCH CAM FITTINGS SHOW SIGNS OF GOUGING. UPPER AFT LATCH ROLLER DAMAGED. FWD UPPER PIN STOP DAMAGED. REPLACED AND ADJUSTED 4 LATCH CAME 2 UPPER AND LATCH ROLLERS ADJED STOP PINS SSDR UALA2012032901981Unknown · leakingFLUID LEAKING IN RIGHT HORIZONTAL STAB AREA. LEAK APPEARS TO BE COMING FROM THE RUDDER AREA AND RUNNING DOWN HORIZONTAL STAB AREA. ACCESSED THE RUDDER PCA'S AND CLEANED AREA. CYCLED THE RUDDER THRU FULL TRAVEL SEVERAL TIMES. NO LEAKS NOTED, CHECK WAS INCONSDR UALA2012032801954Inlet · pinchedFWD PIT FAILS SMOKE DETECTION TEST AT AFT SMOKE PICK-UP. ALL OTHER PORTS WORK NORMALLY. FOUND SMOKE INLET PINCHED. REPOSITIONED RUBBER INLET. OP CHECKED OKAY.SDR UALA2012033001986Wire · brokenSTATUS MESSAGE WILL NOT CLEAR PRIOR TO START. FOUND WIRE BROKEN AT POS A OF D519 ON CAPTAIN'S STICK SHAKER. REPAIRED WIRE. REPLACED LEFT STALL WARNING MODULE PER MM. MESSAGE CLEARED. STALL WARNING SYS TEST OKAY.SDR UALA2012033001984Lanyard · unsecureL2 DOOR WILL NOT ARM. SECURED SLIDE BUSSEL. DOOR ARMING OPERATION NORMAL.SDR UALA2012033001985Insulation · damagedINSULATION DAMAGE FOUND UNDER RT FAN COWL FWD SIDE OF THRUST REVERSER BULKHEAD. LOCATION RED TAGGED FOR IDENTIFICATION. INSPECTED WIRES IN EFFECTED AREA. NO DAMAGE TO WIRES FOUND WHILE AT THE GATE. SECURED WIRES WITH TAPE.SDR UALA2012032701936Control Valve · faultyFLT DECK TEMP ISSUE, FLIGHT DIVERTED. TEMP DROPPED TO 52 DEGREES. TRIM AIR OFF-PACK STANDBY, NO HELP. REPLACED LT PACK TEMP CONTROL VALVE. AFTER RUNNING BOTH LEFT & RIGHT PACK WITH TRIM AIR OFF TEMP IN ALL ZONES STABILIZED AND WAS CONTROLLABLE. INSPECTEDSDR UALA2012032701942Idg · failedRIGHT ENGINE GENERATOR ISSUE, RTFL STARTED APU BUT THAT WAS INTERMITTENT. SAMC TEXT: ACCOMPLISH BITE CHECK OF BPCU IAW AMM. CHECK DPI FOR TRIPPED CONDITION & IDG OIL QUANTITY IAW AMM. ACCOMPLISH VISUAL CHECK OF ENG IDG WIRING & CHECK FOR LEAKS. REMOVED & RSDR UALA2012032601883Generator · failedAPU ELECTRICAL POWER DROPPED OFF AT GATE WITH APU STILL RUNNING. FOUND WINDINGS BAD IN GENERATOR. REPLACED APU GENERATOR. OP'S CHECKED GOOD.SDR UALA2012032601903Panel · unsecureDOOR 1L ARMED WEDGE INDICATOR BINDING ON DOOR PANELING. SECURED MID DOOR TRIM PANEL SCREW FWD SIDE. NR 1 LEFT MAIN ENTRY DOOR. SLIDE ARMING FUNCTION, OPS NORMAL.SDR UALA2012032701931Stringer · bentSTR S-14L BENT STA 630 REF SCAL LP 9664075. REPAIR ACCOMPLISHED ON SCAL NON ROUTINE 9664075. ALSO SEE PTT 5972065 FOR ADDITIONAL INFORMATION.SDR UALA2012032601881Knob · brokenWX RADAR SWITCH KNOB "SKIRT" IS BROKEN. SWITCH FUNCTION IS OKAY. KNOB IS STILL FUNCTIONAL KNOB SHOULD BE REPLACED. NEW WX RADAR PANEL INSTALLED PER MM, OPS CHKS GOOD.SDR UALA2012032601901Stringer · damagedSTRINGER S-14L DAMAGED STA 600-630 REF SCAL LP 9964075,9965403,9965693. MAJOR REPAIR ACCOMPLISHED: INSTALLED STRINGER REPAIRS STA 580-640.SDR UALA2012032601882Indicator · faultyFUEL TOTALIZER INDICATOR HAS NUMBERS FAULTY, TEST FAILED. NEW FUEL TOTALIZER INSTALLED, OPS CHECKED GOOD.SDR UALA2012032601900Squib · no testLEFT BOTTLE PRESSURE FOR EMERGENCY ESCAPE SQUIB FAILS TEST. REPLACED LEFT OVERWING SLIDE PRESSURE BOTTLE PER MM, PASSED SQUIB TEST. UNIT INSTALLED PER AMM AND IS NOW OPERATIONAL.SDR UALA2012032601914Lamp · inoperativeRETURN TO SEAT LIGHT INOPERATIVE AT 1L. RELAMPED FASTEN SEAT BELT SIGN AT DOOR 1L, CHECKED OKAY.SDR UALA2012032701941Duct · crackedRIGHT RECIRCULATION FAN IS OBNOXIOUSLY LOUD, IT IS HARD TO COMMUNICATE WITH IT ON. REPLACED DUCT, LEAK CHECK NORMAL.SDR UALA2012032601886Switch · dirtyCREW REPORTS EMERGENCY EVAC SIGNAL HORN WENT OFF SEVERAL TIMES DURING CLIMB. CLEANED PRESS TO TEST SWITCH AND ACCOMPLISHED PER MM, SYSTEM OPS CHECKED OKAY.SDR UALA2012032601898Blade · damagedNR 2 ENGINE FAN BLADE NR 16 HAS SMALL NICK ON LEADING EDGE OF FAN BLADE AREA 2. NICK MEASURES 0.020 DEEP. NO CRACK OR TEAR VISIBLE. ACCOMPLISHED BLADE REPAIR PER MM. ACCOMPLISHED EDDY CURRENT INSPECTION PER NDT. NO DEFECTS.SDR UALA2012032601920Controller · faultyCOCKPIT TEMPERATURE TOO WARM, TURNED OFF TEMP CONTROLLER TO COOL COCKPIT. REPLACED ZONE TEMPERATURE CONTROLLER. TWO SEGMENTS LATER THE COCKPIT TEMPERATURE BECAME VERY COLD. REPLACED TRIM AIR PRESSURE REGULATING VALVE.SDR UALA2012032601887Audio Panel · inoperativeFIRST OFFICER CANNOT TRAMSMIT ON LEFT HF WITH EITHER BOOM OR HAND MIC. SWAPPED FIRST OBSERVER'S RADIO SELECT PANEL WITH THE FIRST OFFICERS PANEL. CHECKED L-HF RADIO ON THE FIRST OFFICER'S SIDE, OPS CHECKED NORMAL. CHECKED CAPTAINS LEFT HF AND RADIO WAS NORMALSDR UALA2012032601904Blade · damagedNR 2 ENGINE FAN BLADE NR 15 HAS SMALL NICK ON LEADING EDGE OF FAN BLADE AREA 2. EXTENT OF DAMAGE DETERMINED TO BE WITHIN 25 HOUR FLYBACK LIMITS PER AMM. NICK MEASURES 0.020 IN DEPTH. NO TEAR OR CRACK VISIBLE. CARRIED FORWARD PER AMM. ACP'D BLADE REPAIR PESDR UALA2012032601893Duct · crackedPNEUMATIC DUCT THAT CONNECTS BETWEEN TEE DUCT AND LT GROUND CONNECTION IS CRACKED AT MATING SURFACE. REPLACED DUCT, LEAK CHECK NORMAL.SDR UALA2012032601894Duct · crackedPNEUMATIC DUCT FWD OF APU CHECK VALVE IN RT PACK BAY IS CRACKED AT FLANGE MATING SURFACE. INSTALLED DUCT. LEAK CHECKED NORMAL.SDR UALA2012032301857Generator · faultyHMG FAILED TEST. STARTS TO SPIN THEN STOPS. DOES NOT REACH OPERATING SPEED. REF DF330 REMOVED 3EA HYD LINES TO HMG MOTOR TO FACILITATE HMG MOTOR REMOVAL. REINSTALLED AND SEC'S 3 EACH HYDRAULIC LINES.SDR UALA2012032301858Fuel Control · leakingNR 1 ENGINE HAS FUEL LEAK. FUEL LEAKING FROM TOP COVER ON FUEL CONTROL. RMV'D FUEL CONTROL PER AMM. REPLACED FUEL CONTROL.SDR UALA2012032301875Cover · missingDOORWAY AT DOOR 2L JUST FWD OF DOORS' LWR FWD CORNER VENT IS MISSING. REPLACED 1R DOOR MISSING AIR VENT COVER.SDR UALA2012032201840Relay · faultySTATUS MSG R ENG PROBE HEAT. COMPLIED WITH MEL. REPLACED AIR-GRD RELAY SYS 1 K178 AND R ENG OUT RLY K10341 PER WDG30-34-12 & WDG30-31-12, OPS CK PER MM. OPS CHECKED OKAY, NO FAULT NOTED.SDR UALA2012032301874Module · inoperativeEEL EXIT LIGHT JUST FWD OF DOOR 2R AND 2L INOP. RPL INVERTER MODULE M1094 9. REF WDM 33-51-21.SDR UALA2012032201814Connector · damagedRT ENG GENERATOR FEEDER CABLE PINS BURNED AND SEIZED IN CONNECTOR AND ENGINE SIDE CONNECTOR D1092 AT FIRE WALL DISCONNECT. WIRE HARNESS W5610 INSTALLED.SDR UALA2012032301854Connector · dirtyRT ENG ANTI-ICE EICAS MESSAGE. CLEANED CONNECTOR, NO MSG.SDR UALA2012032201816Switch · faultyFSEU 1 SHOWS SLAT LOSS FAULT. REPLACED FSEU 1, NO HELP. RE-INSTALLED ORIGINAL UNIT. FLAPS AND SLATS ARE LOCKED IN NORMAL AND ALTERNATE MODES. REF FIM 27-81-00, SUSPECT A SLAT POSITION TRANSMITTER OR A SLAT LOSS POSITION SENSOR. ACCMP'D TROUBLESHOOTING PESDR UALA2012032201825Bolt · missingDURING DOOR 1 RT SLIDE CHANGE FOUND GATE ROD END BOLT MISSING. INSTALLED BOLT, WASHERS, BUSHING AND NUT. ADJUSTING NUT WAS TIGHT, NO RIG REQUIRED.SDR UALA2012032001802Hinge · leakingDOOR 2L DID NOT STOP PRESSURE SQUEAL UNTIL ABOVE 10,000 FT. PRESSURIZED AC, FOUND LEAK AT DOOR 2L UPPER HINGE. APPLIED REN AT 0500 TO UPPER HINGE AREA. NEED TO SAND AND REPRESSURIZE. SANDED AND PRESSURIZED TWICE TO 4.0 AND 3.0, LEAK STOPPED AT 1.25PSI. OP SDR UALA2012032001810Cover · unsecureEMERGENCY LIGHT STRIP AROUND SEAT 13AB HAS SEPARATED FROM FLOOR. SECURED LIGHT STRIP COVER.
Back to Pratt & Whitney PW2037