Pratt & Whitney PW2040
Service difficulty reports · 2,201
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2040' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2040' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201208173064Floorbeam · corrodedMAIN CARGO DECK FLOORBEAM UPPER TEE AT BS 720 HAS AREAS WITH SCATCHES AND CORROSION. FOUND TO BE OUT OF LIMITS IAW SRM53-00-51, FIG.101 DETAIL III PG.104. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-40-02.MAJOR REPAIRSDR IPXA12574831Link Assy · inoperativeWINDOW WILL NOT CLOSE ON CAPTAINS SIDE. R & R LINK ASSY AND PERFORMED ADJ/TEST IAW M & M 56-11-02. NO HELP. ADJUSTED L2 WINDOW MECHANISM IAW MM 56-11-02-825-001. ALL CHECKS NORMAL.SDR IPXA12574975Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 242XLF HAS COMPOSITE DAMAGE AT CORNER. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574976Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 241XBF HAS COMPOSITE DAMAGE AT CORNER. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574794Floor Panel · damagedINSPECTION TYPE:C, MAIN CARGO FLOOR PANEL 242XDF UPPER SURFACE - FWD OTBD EDGE DAMAGE APPROX 2.5 WIDE AND 0.5 IN INTO UPPER SURFACE OF FLOOR PANEL. FABRICATED MAIN CARGO COMPARTMENT FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574824Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 242XBF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574785Floorboard · delaminatedINSPECTION TYPE:C, MAIN CABIN FLOORBOARD 251XGF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574820Floorboard · delaminatedINSPECTION TYPE:C, MAIN CARGO FLOORBOARD 251XLF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574821Floorboard · delaminatedINSPECTION TYPE:C, MAIN CARGO FLOORBOARD 251XHF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575052Frame · dentedINSPECTION TYPE: C, FWD CARGO BAY BS 660 BETWEEN STR 24R AND 25R, FRAME INNER ANGLE DENTED. REMOVED DAMAGE AND REPAIRED FRAME.SDR IPXA12574736Wedge · damagedLT OTBD AFT FLAP T/E WEDGE LOWER SUFACE HAS SKIN DAMAGE. REPAIRED REF EO 757-5750-48072-A.SDR IPXA12574739Skin · dentedLT HORIZONTAL STAB FWD TORQUE BOX LOWER PANEL DENTED. REPAIRED IAW EO 757-5510-47958-B.SDR IPXA12574936Frame · dentedINSPECTION TYPE: C, AFT CARGO BAY BS 1440 ABOVE STR 23L FRAME IS DENTED. REMOVED DAMAGE, FABRICATED REPAIR J AND HEAT TREATED TO T6 , INSTALLED REPAIR IAW SRM 53-00-07-2R5 M DETAIL III.SDR IPXA2575063Frame · dentedINSPECTION TYPE: C, FRAME IN AFT CARGO BAY BS 1300 BETWEEN STR 24R AND 25R IS DENTED REMOVED DAMAGE AND REPAIRED FRAME IAW EA 120959IR & EO B757-5310-48294-A.SDR FDEA201208042854Roller · out of adjustDURING B-CHECK, FOUND L1 DOOR UPPER FWD CRANK ARM ROLLER CONTACTS THE CAM PLATE WHEN CLOSING THE DOOR. ACCOMPLISHED RIGGING OF L1 DOOR UPPER FWD CRANK ROLLER CAM PLATE AND ROLLER IAW AMM NO FAULTS NOTED.SDR FDEA201208042855Cam · out of rigDURING B CHECK, L1 DOOR UPPER FWD CAM PLATE NEEDS TO BE RIGGED. ACCOMPLISHED RIGGING OF L1 DOOR UPPER FWD CAM PLATE IAW AMM. NO FAULTS NOTED.SDR IPXA12574728Floorboard · damagedINSPECTION TYPE:C, FLOORBOARD 231XLF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574991Frame · dentedINSPECTION TYPE:C-CK, FORWARD CARGO BAY BS 680 BETWEEN STR 24R AND 25R, FRAME UPPER CHORD FLANGE DENTED. REMOVED DAMAGE, FABRICATED REPAIR J, HEAT TREATED TO T6 AND INSTALLED REPAIR IAW SRM 53-00-07-2R5, DETAIL III.SDR IPXA12574992Frame · dentedINSPECTION TYPE: C, AFT CARGO BAY BS 1580 AT STRINGER 26L FRAME HAS DENT ON FLANGE. FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-07-2R 5, DETAIL III.SDR IPXA12574998Frame · dentedINSPECTION TYPE:C, FORWARD CARGO BAY BS 720 AT STR 24L FRAME DENTED. REPAIRED DAMAGED FRAME IAW SRM 53-00-07-2R, REPAIR 5, DETAIL III.SDR IPXA12575000Frame · dentedINSPECTION TYPE: C, FWD CARGO BAY BS 740 BETWEEN STR 24L AND 25L, FRAME DENTED. REPAIRED FRAME IAW SRM 53-00-07-2R, REPAIR 5, DETAIL III.SDR IPXA12575011Frame · dentedINSPECTION TYPE: C, FORWARD CARGO BAY BS 720, ABOVE STR 23R, TWO EACH DENTS APPROX 4 INCHES APART. REMOVED DAMAGE AND FABRICATED REPAIR. INSTALLED REPAIR IAW SRM 53-00-07-2R5, DETAIL 2 AN AND EO B757-5310-44696-A.SDR IPXA12575013Frame · gougedINSPECTION TYPE:C, FORWARD CARGO BAY BS 820 S22R FRAME GOUGED. REMOVED DAMAGE, FABRICATED REPAIR AND HEAT TREATED TO T6. INSTALLED REPAIR IAW SRM 53-00-07-2R5, DETAIL 1.SDR IPXA12575101Frame · dentedINSPECTION TYPE: C, FORWARD CARGO BAY BS 760 STR 24R FRAME UPPER CHORD FLANGE DENTED. REPAIRED FRAME IAW EA 120962R AND EO B757-5310-48376-A.SDR IPXA12575106Frame · dentedINSPECTION TYPE: C, FWD CARGO BAY BS 700 FRAME DENTED BETWEEN STR 24L AND 25L. R & R FRAME FROM STR 13L TO 26L IAW DWG 143N1024 AND EA 120964 AND EO B757-5310-48288-A.SDR IPXA2575123Frame · dentedINSPECTION TYPE: C, FWD CARGO BAY BS 820, STR 22R FRAME UPPER FLANGE GOUGED. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-07-2R5, DETAIL 1.SDR IPXA12574718Floor Panel · delaminatedINSPECTION TYPE: C, LT SIDE FLOOR PANEL 231XSF DELAMINATED. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574721Floorboard · delaminatedINSPECTION TYPE:C, FLOORBOARD NR 232XUF HAS DELAMINATION. FABRICATED FLOORBOARD IAW EO B757-5320-9695-H.SDR IPXA12574733Floor Panel · puncturedINSPECTION TYPE:C, MAIN CARGO FLOOR PANEL 232XAF SKIN IS PUNCTURED. FABRICATED MAIN CARGO FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA12574734Floor Panel · puncturedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 222XAF HAS A PUNCTURE ON FWD RT OF PANEL. FABRICATED MAIN CARGO FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA12574740Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 231XMF HAS INSERTS PULLED FROM PANEL. FABRICATED MAIN CARGO FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA12574742Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO BAY FLOOR PANEL 232XVF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574746Floor Panel · damagedINSPECTION TYPE:C, MAIN CARGO FLOOR PANEL 231XGF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574747Floor Panel · damagedINSPECTION TYPE:C, MAIN CARGO FLOOR PANEL 221XCF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574748Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 231XAF HAS EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL HAS EDGE DAMAGE IAW EO 757-5320-9692-H.SDR IPXA12574749Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XNF HAS CORNER/EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL HAS EDGE DAMAGE IAW EO 757-5320-9692-H.SDR IPXA12574751Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 231XVF HAS INSERT PULLED FROM PANEL. FABRICATED NAIN CARGO FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA12574752Floor Panel · puncturedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 231XNF HAS SEVERAL PUNCTURES. FABRICATED MAIN CARGO FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574758Floor Panel · damagedINSPECTION TYPE: C-CK, MAIN CARGO FLOOR PANEL 232 XXF HAS EDGE DAMAGE/ DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574759Floor Panel · crackedINSPECTION TYPE: C-CK, MAIN CARGO FLOOR PANEL 221XBF IS CRACKED ACROSS FWD LT LEG OF PANEL. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574776Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 231XBF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574999Skin · corrodedINSPECTION TYPE: C, RIGHT SIDE UPPER EMPENNAGE EXTERIOR, APU INLET FRAME FWD END SKIN BULGING AROUND FASTENERS AND AT GAP. REPAIR DAMAGED APU INLET FRAME IAW DWG LOR5L53011.SDR IPXA2574669Seat Track · damagedINSPECTION TYPE: C, CARGO TRACK BS 440-680 LBL 45 DAMAGED. R & R AND REPAIRED MAIN CARGO SEAT TRACK BS 440-680, LBL 45 IAW EO B757-5310-39408-A.SDR IPXA2574673Duct · disconnectedAT FL250 CABIN ALTITUDE EICAS MESSAGE CAME ON, CABIN PRESSURE WAS 10200 CABIN ALTITUDE LIGHT EXTINGUISHED AT AROUND FL200 EMERGENCY DECLARED. FOUND RT CABIN AIR SUPPLY CHECK VALVE DUCT NOT CONNECTED, RED DUCT, ADJUSTED AND RECONNECTED DUCT. PERFORMED SINGLE SDR IPXA2575060Seat Track · damagedINSPECTION TYPE: C, SEAT TRACK DAMAGED BS 440 TO 660 AT LBL 45.5. R & R SEAT TRACK IAW EA 120947 AND EO B757-5310-48260-A.SDR IPXA2574677Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 231XHF DAMAGED AND REQUIRES FABRICATION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574711Floorboard · damagedINSPECTION TYPE:C-CK, RT SIDE FLOORBOARD 252XQF HAS MISSING INSERTS. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574712Floor Panel · damagedINSPECTION TYPE:C, BS 1320 LT FLOOR PANEL 251XDF HAS PULLED INSERTS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574713Floor Panel · crackedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251AF CRACKED IN THE MIDDLE OF PANEL. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574715Floor Panel · damagedINSPECTION TYPE:C, BS 1600, LT FLOOR PANEL 251XNF HAS EDGE/CORNER DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.
Back to Pratt & Whitney PW2040