Pratt & Whitney PW4056
Service difficulty reports · 12,595
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA05591Light · inoperativeAFT MAIN GALLEY WALL EMERGENCY LIGHT FWD OF GALLEY AND LT SIDE INOP.SDR 2008UALA05592Lamp · inoperativeEMERGENCY LIGHT SEAT 4A AFT INOP. FOUND FAULTY LAMP. RELAMPED, OP CHECKS NORMAL.SDR 2008UALA05596Light · unsecureTHE 2B EMERGENCY LIGHT FELL OFF. FOUND LIGHT UNSECURE. SECURED EMERGENCY LIGHT ASSY TO SIDE OF SEAT 2B. OPS CHECKS OKAY.SDR UALA2008111305591Light · inoperativeAFT MAIN GALLEY WALL EMERGENCY LIGHT FWD OF GALLEY AND LT SIDE INOP. REPLACED TWO LIGHTS & TWO FEEDERS. OP CHECKS NORMAL.SDR 2008UALA05565Lamp · inoperativeDOOR 2L EXTERIOR EMERGENCY LIGHT INOP.
SDR 2008UALA05538Light · wrong partSEAT ROW 36ABC EEL IS INADEQUATE. *S/D* IMPROPER PART. REPLACED LIGHT ASSY.
SDR 2008UALA05606Hydraulic System · overheatedNR 4 HYD OVERHEAT, TEMP WOULD RISE TO 96 DGR WITH ADP RUNNING, TEMP WOULD RISE TO 88 DEGREES WITH AUX PUMP RUNNING. DPI INDICATORS ARE IN ON CASE DRAIN MODULE AND RETURN FILTER MODULE. MEASURED TEMPERATURE AT RETURNED MODULE MATCHES FLIGHT DECK INDICATION ANSDR UALA2008111305565Light · inoperativeDOOR 2L EXTERIOR EMERGENCY LIGHT INOP. FOUND LIGHT INOPERATIVE. REPLACED LAMP. OK CHECKS NORMAL.SDR UALA2008111305606Sensor · faultyNR 4 HYD OVERHEAT, TEMP WOULD RISE TO 96 DGR WITH ADP RUNNING, TEMP WOULD RISE TO 88 DEGREES WITH AUX PUMP RUNNING. DPI INDICATORS ARE IN ON CASE DRAIN MODULE AND RETURN FILTER MODULE. MEASURED TEMPERATURE AT RETURNED MODULE MATCHES FLIGHT DECK INDICATION ANSDR 2008UALA05561Lamp · inoperativeEMERGENCY LIGHT INOP AT 49ABC. FAULTY LAMP. REPLACED EMERGENCY LIGHT.
SDR 2008UALA05550Lamp · inoperativeSEAT 2J AFT EMERGENCY LIGHT FLOOR INOP. FOUND FAULTY LAMP. REPLACED LAMP STRIP, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA05551Lamp · inoperativeSEAT 5F AFT FLOOR EMERGENCY LIGHT INOP. FOUND FAULTY LAMP STRIP. REPLACED LAMP STRIP, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA05552Lamp · inoperativeSEAT 5J FWD FLOOR EMERGENCY LIGHT INOP. FOUND FAULTY LAMP STRIP. REPLACED LAMP STRIP, OP CHECK GOOD. AC OK FOR SERVICE.
SDR 2008UALA05553Lamp · faultyDOOR 4L DOOR MOUNTED EMERG EVAC LIGHT ONLY STAYS ON FOR A FEW SECONDS. FOUND FAULTY LAMP. REPLACED LAMP, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA05548Lamp · inoperativeCEILING EMERGENCY LIGHT ABOVE DOOR 1R INOP. FAULTY LAMP. RELAMPED, OP CHECKS OKAY.
SDR 2008UALA05549Lamp · inoperativeUPPER DECK CEILING EMERGENCY LIGHT, SEAT 16 INOP. *S/D* LIGHT FAULTY. RELAMPED, OP CHECKS OKAY.
SDR 2008UALA05536Battery Pack · inoperativeTHE A-ZONE LT COLUMN EMERGENCY LIGHT INOP. REPLACED BATTERY PACK, OP CHECK OKAY.SDR 2008UALA05517Coupling · faultyHF TRANSMISSION AND RECEPTION ARE INOP, WEAK, GARBLED INTERMITTENT, ETC AT ALL CREW STNS (1 = L HF, 2 = R HF) 2 CREW COMMENTS: RT HF RECEPTION REPORTED INTERMITTENT BY SFO RADIO. DURING POSITION REPORTS IT CUTS OUT. RT HF TRANSCEIVER WILL TUNE BUT REC WEAK.SDR 2008UALA05519Oxygen Bottle · lowCREW OXYGEN SYSTEM LOW. CREW COMMENTS: CREW O2 NEEDS SERVICING. *S/D* SUSPECT PRE FLIGHT CHECKS. SERVICED SYSTEM TO FULL. AC OK FOR SERVICE.SDR 2008UALA05479Controller · faultyAPU WILL NOT START. HANGS BETWEEN 0-10% RPM. SHUTS DOWN WITH APU FAULT LIGHT ON. REPLACED APU CONTROLLER, APU BATTERY, BATTERY CHARGER, AND APU STARTER. OPS CHECK OK.SDR 2008UALA05468Unknown · odorHEAVY ODOR (BURNING SMELL) IN CABIN. RTFL.SDR 2008UALA05497Lens · missingOVERWING EMERGENCY LIGHT LENS MISSING.SDR 2008UALA05493Coffeemaker · smokeAFT GALLEY SMOKE APPEARING. OCCURRED JUST PRIOR TO LANDING AND ELECTRICAL POWER REMOVED FROM GALLEY AS A PRECAUTION. PER FLIGHT ATTENDENTS, THEY SAW A SMALL AMOUNT OF SMOKE COMING FROM AREA NEAR AFT LEFT COFFEE WARMER. OPERATED ALL AFT GALLEY EQUIPMENT. CHECSDR 2008UALA05487Unknown · odorSMOKE APPEARED IN AFT GALLEY.SDR 2008UALA05498Light · missingSEAT 24H EMERGENCY LIGHT MISSING. REPLACED EMERGENCY LIGHT AT SEAT 24H.SDR UALA2008111305497Lens · missingOVERWING EMERGENCY LIGHT LENS MISSING. LENS OUT OF POSITION. REPLACED MISSING LENS.SDR UALA2008111305468Unknown · contaminatedHEAVY ODOR (BURNING SMELL) IN CABIN. RTFL. AC SYSTEM OIL CONTAMINATION REMOVAL. ENGINE RUN TO REMOVE OIL ODORS. SIX QUARTS OIL REMOVED FROM OIL TANK. ALL OIL SMELL HAS DISSIPATED FROM NR 1 ENG BLEED SYSTEM. NO ODORS PRESENT AT END OF PACK BURN.SDR UALA2008111305487Unknown · smokeSMOKE APPEARED IN AFT GALLEY. PER FLIGHT ATTENDANT, SAW A SLIGHT AMOUNT OF SMOKE COMING FROM AREA NEAR AFT LEFT COFFEE WARMER. OPERATED ALL AFT GALLEY EQUIPMENT. CHECKED AREA. NO SMOKE DETECTED. GALLEY 428 NR 181 GETS TOO HOT. OPS OK. NO OTHERS DEFECTS SDR 2008UALA05454Connector · unsecureEMERGENCY LIGHT AFT GALLEY BOTTOM WALL LT INOP. RESECURED EMERGENCY LIGHT CONNECTOR. OP CHECK NORMAL.SDR 2008UALA05459Unknown · odorELECTRICAL ODOR MAIN DECK GALLEY. RTFL.SDR 2008UALA05461Skin · puncturedLEFT INBOARD FORE FLAP LEADING EDGE HAS A LARGE PUNCTURE. REMOVED LEFT INBOARD FORE FLAP. COMPLETE FORE FLAP INSTALLATION FROM ITEM 3 PAGE 407 TO COMPLETION.SDR 2008UALA05467Turbine Blades · failedLEFT ENGINE SURGE DET STATUS MSG. FOUND METAL IN THE TAILPIPE. THE ENGINE WAS REPLACED AT PRIOR TO FURTHER FLIGHT. SHOP TEARDOWN REVEALED THAT THE ENGINE HAD SUFFERED AN HP TURBINE STAGE-2 BLADE UNDER PLATFORM STRESS CORROSION (SCC) FAILURE. ONE BLADE FRACSDR 2008UALA05471Connector · inoperativeEMERGENCY LIGHT AT SEAT 13 NOT LIGHTED WHEN LIGHTS ON. SINGLE SEAT LIGHT INOP 13H. ADJACENT LIGHTS ALL WORK OK. RESEATED CONNECTOR AT OUTBOARD SEAT. LIGHT OP CHECKS GOOD.SDR 2008UALA05453Battery · inoperativeEMERGENCY EXIT LIGHT DOOR 5 LT INOP. REPLACED BATTERY. OP CHECK NORMAL.SDR 2008UALA05452Battery Pack · inoperativeEMERGENCY LIGHT FROM ROW 55 TO 61 INOP. REPLACED BATTERY PACK. OP CHECK NORMAL.SDR UALA2008111305461Flap · puncturedLEFT INBOARD FORE FLAP LEADING EDGE HAS A LARGE PUNCTURE. FOUND PUNCTURED FORE FLAP DAMAGED FROM TIRE TREAD. REPAIRED DAMAGED SPAR PER SRM 51-70-12, REPAIR 1. REPAIRED LOWER PANEL ON R61502 PER SM-80-57-53-17-JD. REPAIRED L/E BULLNOSE ON R61505 PER SRM 57-SDR UALA2008111305459Connector · chafedELECTRICAL ODOR MAIN DECK GALLEY. RTFL. FOUND PIGTAIL CONNECTOR WIRE BUNDLE FOR P56 AND P57 LOCATED ON BACK WALL WHERE GALLEY OVEN CARTS GO TO BE CHAFED IN TWO PLACES. REPLACED THE WIRE BUNDLE FOR P56 TO P57. OVERHEAD GALLEY LIGHT IN MID GALLEY INOP. REPLSDR 2008UALA05451Lamp · inoperativeEMERGENCY CEILING LIGHT ROW 44 LT INOP. RELAMPED, OP CHECK NORMAL.SDR 2008UALA05450Light · brokenFLT ATT REPORTED SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHT BROKEN OFF SEAT 16H. REMOVED BROKEN LIGHT FROM ACFT AND STOWED WIRES. REPLACED EMERGENCY LIGHT. OP CHECKS GOOD.SDR 2008UALA05425Cable · unsecureLEFT SIDE A ZONE EMERGENCY LIGHT, SEATS 1A-5A IS INOP. FOUND UNDER SEAT CABLE OFF. RECONNECTED, CHECKS NORMAL.SDR 2008UALA05429Battery · inoperativeLEFT OVERWING 4 EACH EMERGENCY LIGHT IS INOP. REPLACED BATTERY. CHECKS NORMAL.SDR 2008UALA05423Lamp · inoperativeDOOR 3 LEFT CEILING 1 EA EMERGENCY LIGHT IS INOP. RELAMPED, CHECKS NORMAL.SDR 2008UALA05422Lamp · inoperativeSEAT 55HJK EMERGENCY LIGHT IS INOP. RELAMPED, CHECKS NORMAL.SDR 2008UALA05424Lamp · inoperativeDOOR 3 LEFT SILL EMERGENCY LIGHT IS INOP. FOUND BURNED OUT LAMP. REPLACED LAMP, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA05421Lamp · inoperativeDOOR 2 RIGHT SILL EMERGENCY LIGHT IS INOP. RELAMPED. CHECKS NORMAL.SDR UALA2008111305443Apu · malfunctionedAPU WILL NOT START. FADEC SHOWED NO FAULTS. STARTED AND RAN APU WITH AIR AND ELECTRICAL LOADS AT GATE. COULD NOT REPLICATE FAULT. OK FOR SERVICE.SDR 2008UALA05393Smoke Detector · malfunctionedSMOKE ALARM IN FLT ATT CREW REST AREA WENT OFF TWICE ON TAXI IN. ALSO LOUD NOISE HEARD BENEATH 5L- :DOOR 5 SMOKE DETECT C/B CYCLED, SYS RESET, ALL OPS NORMAL. UNABLE TO REPRODUCE LOUD NOISE UNDER 5 L.SDR 2008UALA05394Bearing · wornFOUND METAL DEPOSIT ON NR 1, 1.5 AND 2 BEARING CHIP DETECTORS AND MAIN OIL FILTER. WILL REQUIRE NR 4 ENG REPLACEMENT. ENGINE WAS REPLACED AT LAX PRIOR TO FURTHER FLIGHT. SHOP TEARDOWN FOUND THE NR 1 BEARING WITH A BALL COMPLETELY MISSING. THE BALL HAD FAISDR 2008UALA04374Power Supply · intermittentEMERGENCY EXIT AND PATH LIGHTS AT DOORS 2L-2R IN BUSINESS CLASS COME ON INTERMITTENTLY. *S/D* REPLACED POWER SUPPLY M6002 AT DOOR 2R.SDR 2008UALA05415Fire Bottle · malfunctionedBTL LOW CARGO B MSG DISPLAYED AND DISCHARGE LIGHT ON OVERHEAD PANEL ILLUMINATED, NO FWD OR AFT LIGHT ON. REPLACED FIRE "B" BOTTLE.
Back to Pratt & Whitney PW4056