Service difficulty report · Sensor · Boeing 747422

Difficulty date
September 2, 2008
Submitted
December 31, 2008
Operation
Air carrier
Aircraft
N175UA
Make and model
Boeing 747422
Aircraft serial
24382
Aircraft time
71,439 hours, 8,090 cycles
Engine
Pwa PW4056
Part
Sensor
Condition
Faulty
Location
Hydraulic Sys
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 4 HYD OVERHEAT, TEMP WOULD RISE TO 96 DGR WITH ADP RUNNING, TEMP WOULD RISE TO 88 DEGREES WITH AUX PUMP RUNNING. DPI INDICATORS ARE IN ON CASE DRAIN MODULE AND RETURN FILTER MODULE. MEASURED TEMPERATURE AT RETURNED MODULE MATCHES FLIGHT DECK INDICATION AND HYD QTY IS NORMAL. REPLACED NR 4 ENG HYD TEMP SENSOR, RETURN FILTER, AND CASE DRAIN FILTERS.