SDR ANCF200700024Warning Light · false activationWEATHER FAIL DISPLAYED ON HSI, AFTER WXR TEST WEATHER FAIL DISAPPEARS. IAW FIM 34-43-00. FIGURE 103, BLOCKS 1,2 AND 3 THE WXR BITE PROCEDURE WAS ACCOMPLISHED SATISFACTORY.SDR 2007UALA04288Bottle · lowCREW O2 PRESSURE SHOWS 1580. SERVICED CREW OXYGEN BOTTLE TO 1730 PSI. AC OK FOR SERVICE.SDR 2007UALA04265Feeder Cable · faultyEEL INOP ROWS 35-44 LEFT & EMERGENCY EXIT SIGN INOP DOOR 3L FWD. 11-01-07 REPLACED CABLE.
SDR 2007UALA04266Connector · unsecureEEL INOP DOOR 4L LOWER GALLEY WALL. 11-01-07 SECURED CONNECTOR.SDR 2007UALA04267Lamp · inoperativeEEL INOP ROW 52R. 11-01-07 RELAMPED.SDR 2007UALA04274Oxygen Mask · defectiveF/O O2 MASK DEFECTIVE. REPLACED 2ND OBSERVERS O2 MASK ASSEMBLY. LEAK CHECKED GOOD PER AMM 35-11-18-401 ITEM 4. AC OK FOR SERVICE.SDR 2007UALA04257Switch · faultyTHE "RIGHT BODY GEAR RIGHT ACTUATOR LOCK SWITCHES DISAGREE" HAS OCCURRED AT LEAST 3 OUT OF LAST 5 FLT. FOUND RT GEAR STEARING ACTUATOR, ALTERNATE INBOARD SWITCH SHOWING UNLOCKED. REPLACED RT BODY LANDING GEAR RT ACTUATOR ALTERNATE SWITCH IAW MM 32-53-16. AC SDR 2007UALA04258Oxygen Mask · leakingOXYGEN MASK STOWAGE COMPARTMENT DEFECTIVE - CAPT. REW COMMENTS: CAPT O2 MASK LEAKS WHEN DEPLOYED AND LEFT PANEL IN CLOSED FOR COMMS PLUNGER IS OUT OF ADJUSTMENT. REPLACED CAPTAIN 02 MASK, OPS CHECK GOOD. AC OK FOR SERVICE.SDR 2007UALA04160Extinguisher · low pressureRT WING "B" EXTINGUISHER BOTTLE LOW PRESS LIGHT ON, VERIFIED BOTTLE LOW. REPLACED "B" EXTINGUISHER BOTTLE (RT WING) AND RELATED SQUIBS. REF. MM 26-21-03 AC OK FOR SERVICE.
SDR 2007UALA04166Light · inoperativeEMERGENCY LIGHT INOP AT SEAT 43HJK & AT SEAT ABC. 11-01-07 RELAMPED.SDR 2007UALA04167Light · inoperativeRIGHT OVERWING 2 FWD ASSY. EMERGENCY LIGHT INOP. 11-01-07 REPLACED POWER SUPPLY.SDR 2007UALA04168Light · inoperativeEMERGENCY CEILING LIGHT INOP AT ROW 32 ABC. 11-01-07 RELAMPED.SDR 2007UALA04169Cable · cutZONE-C RIGHT EEL CABLE CUT. 11-01-07 REPLACED WITH NEW CABLE. OPS CHECKED NORMAL.SDR 2007UALA04136Skin · dentedSTATION 400-420 S41-42R, EXTERNAL FUSELAGE SKIN IS DENTED. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SKIN. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2007UALA04137Cylinder · low pressureNR 5R MED ESCAPE SLIDE CYLINDER PRESSURE LOW. SUSPECT FAULTY RELEASE VALVE SEAL. REPLACED SLIDE RAFT ASSEMBLY. AC OK FOR SERVICE.SDR 2007UALA04138Seal · leakingESCAPE SLIDE PRESSURE LOW, UPPER DECK RT AFT. SUSPECT FAULTY RELEASE VALVE SEAL. REPLACED WITH SERVICEABLE RESERVOIR AT UPPER DECK RT AFT PER AMM 25-68-02. AC OK FOR SERVICE.SDR 2007UALA04139Light · brokenSEAT 3J, EEL LIGHT BROKEN. 11-01-07 REPLACED EEL LIGHT ASSY. OP CHECKS OK FOR SERVICE.SDR 2007UALA04140Light · inoperativeWALL EEL INOP: CLOSET FWD OF LAV 104, CROSS AISLE & LT SIDE OF LAV 110 & LT SIDE FWD GALLEY ACROSS FROM LAV 100. 11-01-07 SECURED LOOSE CONNECTIONS IN EACH POSITION, EEL SYSTEM OP CHECKED GOOD FOR SERVICE.SDR 2007UALA04141Light · inoperativeEMERGENCY LIGHT INOPERATIVE: CEILING ROWS 4R, 12 & 17. 11-01-07 REPLACED LAMP IN EACH POSITION. ALL OP CHECKED GOOD FOR RETURN TO SERVICE.SDR 2007UALA04142Light · inoperativeWALL EEL INOP: LEFT SIDE MID LAV. 11-01-07 REPLACED WALL LAMP.SDR 2007UALA04144Connector · unsecureALL LEFT SEAT EEL INOP B-ZONE. 11-01-07 FOUND LOOSE CONNECTOR. SECURED CONNECTOR & EEL SYSTEM OP CHECKED OK FOR SERVICE.SDR 2007UALA04147Connector · looseEXIT EEL SIGN INOP: DOOR 2L AFT SIDE. 11-01-07 SECURED LOOSE CONNECTION. EXIT LIGHT OP CHECKED OK FOR SERVICE.SDR 2007UALA04124Lamp · inoperativeFOUND CEILING EMERGENCY LIGHTS AT 26 RT, 41 RT AND LAV 100 ARE INOPERATIVE. RELAMPEDSDR 2007UALA04125Light · inoperativeFOUND EMERGENCY LIGHT INOP 3A AFT AND 5E AFT. REPLACED LIGHT ASSEMBLY
SDR 2007UALA04126Connector · faultyDOOR 1R BOTH SILL EMERGENCY LIGHTS, EMERGENCY EXIT SIGN ABOVE DOOR 1R, CEILING EMERGENCY EXIT LIGHT AT DOOR 1R AND AISLE EMERGENCY EXIT SIGN AT DOOR 1R ARE INOPERATIVE. 11-01-07 RECONNECTED BATTERY PACK CONNECTOR.
SDR 2007UALA04127Battery Pack · inoperativeFOUND 2L MED EMERGENCY LIGHTS INOPERATIVE. 11-01-07 REPLACED WITH NEW BATTERY.
SDR ANCF200700022Torque Tube · unknownPILOT REPORT EICAS MSG LE SLAT DISAGREE DISPLAYED LEADING EDGE LIGHT ILLUM WITH THE FLAP LEVER IN 1. BOTH FLAP POINTERS WERE ON .5. IAW AMM 27-81-24 PG 401 TO 420 IN RT WING OB SLAT , ONE TORQUE TUBE WAS REPLACED P/N ON AND OFF 256T2800-105SDR 2007UALA04077Idg · failedRTFL DUE TO NR 1 GEN AND NR 1 ELEC A/C BUSS INOP. OTHER A/C BUSSES WOULD NOT PICK UP LOAD. REPLACED NR 1 IDG. SHOP FOUND FAILED ROTOR. REPLACED LOG, ROTOR, SHAFT SEAL, & FILTER.SDR 2007UALA04085Lamp · inoperativeFOUND EMERGENCY LIGHT ROW 35 ABC INOP. RELAMPEDSDR 2007UALA04086Light · unsecureFOUND EMERGENCY LIGHT ROW 43 ABC INOP. RESECURED EMERGENCY LIGHT. OP CK NORMAL.
SDR 2007UALA04087Connector · unsecureFOUND EMERGENCY LIGHT AT ROW 44ABC. RESECURED EMERGENCY LIGHT.
SDR 2007UALA04170O-Ring · low pressureMAIN ENTRY DOOR SLIDE PRESSURE GAUGE IS NOT WITHIN THE GREEN BAND. PRESSURE TESTED FOR LEAK. O-RING AT GAUGE ELBOW ASSEMBLY LEAKING. REMOVED AND REPLACED O-RING. RETESTED AND TESTED OK
SDR 2007UALA04039Light · brokenFOUND SEAT 3A SEAT MOUNTED EMERGENCY LIGHT BROKEN OFF. REPLACED LIGHT ASSEMBLY.
SDR 2007UALA04024Lamp · inoperativeFOUND UPPER DECK SEAT AREA 15AB CEILING EMERGENC Y LIGHT IS INOP. RELAMPEDSDR 2007UALA04025Lamp · inoperativeFOUND SEATS 33 ABC, 37 ABC, 52 ABC AND 53 ABC EMERGENCY LIGHTS ARE INOPERATIVE. RELAMPED
SDR 2007UALA03963Structure · damagedRIGHT OUTBOARD AFT FLAP HAS 3 INCH DIA HOLE, BOTTOM AT APPROX 4 FT OUT FROM INBOARDD EDGE AND 7 INCHES UP FROM T/E. REPAIRED IAW SRM 51-70-02. AC OK FOR SERVICE.SDR 2007UALA03964Skin · delaminatedLEFT MID FLAP DELAM AND DAMAGE. LEADING EDGE INBOARD, EXTENDING OUT APPROX 5 INCHES. SUSPECT MOISTURE CONTAMINATION. REPLACED THE LT OUTBOARD FLAP PER MM-27-51-04. AC OK FOR SERVICE.SDR 2007UALA04015Light · inoperativeFOUND EMERGENCY CEILING LIGHTS INOP ROWS 35 HJK - 46 HJK. RELAMPED
SDR 2007UALA04016Light · inoperativeFOUND EEL AT ROW 32-34 HJK AND 52HJK ARE INOP. REPAIRED SHORT CIRCUIT.SDR 2007UALA04017Wire · damagedFOUND EMERGENCY EXIT SIGN INOP DR 3R AFT. REPAIRED WIRING.SDR 2007UALA04018Lamp · inoperativeFOUND DR 1L EMERGENCY SLIDE ILLUM LIGHT INOP. RELAMPEDSDR 2007UALA04019Connector · unsecureFOUND EEL AT DR 3R AND L XAISLE INOP. SECURED CONNECTOR AT LAMP.
SDR 2007UALA04020Lamp · inoperativeFOUND EEL 4J FWD INOPERATIVE. RELAMPEDSDR 2007UALA04010Light · inoperativeEMERGENCY LIGHTS INOP AT 4E AFT, 4J AFT, 5J AFT, 43 ABC AND 58 ABC. REPLACED LIGHT ASSEMBLIES.
SDR 2007UALA04011Lamp · inoperativeFOUND SEATS 5A FWD, 8A AFT AND 56 HJK ARE INOPERATIVE. RELAMPED
SDR 2007UALA04012Lamp · inoperativeFOUND DOOR 2R AFT SILL EMERGENCY LIGHT IS INOPERATIVE. RELAMPEDSDR 2007UALA04013Battery · inoperativeFOUND RIGHT OVERWING AFT TWO EMERGENCY LIGHTS ARE INOP.SDR 2007UALA04014Lamp · inoperativeUPPER DECK FWD TWO CEILING EMERGENCY LIGHTS ARE INOP. RELAMPEDSDR 2007UALA03951Relay · faultedLOST PRIMARY FLAPS ON ALT MODE. 10-23-07 REPLACED RELAYS R7515 & R7513 IN PANEL P54 AS PER SSM 27-51-02 & 03 AND PER FIM TASK 27-51 883-8 84.
RAN FLAPS ON GROUND-NO FAULTS-OP CHECKS NORMALLY.SDR 2007UALA03918Light · inoperativeTHE 5A EXIT LIGHT INOP. *S/D* REPLACED EXIT EEL LIGHT AT DOOR 5A. OP CHECKS OK FOR SERVICE.