Pratt & Whitney PW4056
Service difficulty reports · 12,595
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2005UALA00506Light · inoperativeTWO AFT, LT OVERWING EMERGENCY LIGHTS INOP. REPLACED PWR SUPPLY FIRST WITH NO HELP (PRECAUTIONARY), THEN REPLACED 2 EA LIGHT ASSY, LIKELY ONE OF WHICH WAS SHORTED. LIGHTS WORKED FINE AFTER REPLACEMENT.SDR 2005UALA00522Oil Cooler · leakingFUEL LEAK NR 4 ENGINE. DIVERTED TO NARITA. CP07 AIR/OIL COOLER TUBE CRACKED. TUBE & CLAMPS WERE REPLACED. AGB REMOVED. SUSPECT AGB VIBRATION CAUSED TUBE CRACK. AGB TEARDOWN REVEALED NO DISCREPANCIES. ENGINE SUBSEQUENTLY REMOVED AS PRECAUTIONARY. SHOP INPUTSDR 2005UALA00496Skin · gougedSKIN DENTED AND GOUGED 9 INCHES FWD OF BS 1961, 2 INCHES BELOW STRINGER 41R. DAMAGE REPAIRED PER SRM 53-00-01, FIGURE 201.SDR 2005UALA00497Frame · dentedAFT CARGO LWR FRAME AT BS 1760, BL 0 IS DENTED ON UPPER TEE CHORD. DAMAGE REPAIRED PER FAA-APPROVED ENGINEERING DOCUMENT 747-5360-13-1295.SDR 2005UALA00521Wire Harness · burnedWIRE BUNDLE APPEARS BURNED UNDER CLAMP, AFT OF LEFT 2.9 BLEED VALVE AT BRACKET. CLOSER RE-EXAMINATION DISCLOSED THAT HARNESS WAS NOT BURNED. IT HAD BEEN OVERSPRAYED BY SOME UNKNOWN SUBSTANCE. NO CORRECTIVE ACTION REQUIRED.SDR 2005UALA00512Skin · dentedDENT FOUND ON BULK CARGO DOOR OUTER SURFACE. DENT'S DIMENSION APPROX 0.5 X 0.2 INCH WITH LESS THAN 0.04 INCH IN DEPTH. DENT ON BULK CARGO DOOR EXTERNAL SURFACE. DAMAGE DUE TO IMPACT WITH GROUND EQUIPMENT. REPAIRED PER 747 SRM 52-00-01.SDR 2005UALA00484Battery · dischargedLT SIDE EMERGENCY STRIP LIGHTING IN ZONE C GOES ON AND OFF. BATTERY NOT HOLDING CHARGE. EEL LIGHT BATTERY REPLACED.SDR 2005UALA00513Skin · damagedSMALL SCRAPE ON FUSELAGE BETWEEN DOOR 5 LEFT AND STATIC PORT. SMALL SCRAPE AND DENT ON FUSELASE MEASURES-MINOR AXIS 5.0", DEPTH 0.15" A OVER Y EQUALS 50.0 - ACCOMPLISHED SKIN CUTOUT AND FABBED DOUBLER PER SRM 53-00-01 FIG.201. AREA AFFECTED IS STA 2350 APSDR 2005UALA00485Battery · dischargedDOOR 3 LT, ZONE C EEL BATTERY INOP. BATTERY NOT HOLDING CHARGE. EEL LIGHT BATTERY REPLACED.SDR 2005UALA00481Warning System · activatedEVAC ALARM ACTIVATED. DOOR 1 RH COMMAND SWITCH IN ON POSITION. MECHANICS FOUND THAT DOOR 1 RIGHT COMMAND SWITCH WAS IN THE "ON" POSITION. SELECTED THE SWITCH TO THE "OFF" POSITION AND THE SYSTEM CHECKED OUT NORMAL. NO OTHER HITS SINCE.SDR 2005UALA00404Bottle · lowLOW BOTTLE PRESSURE.SDR 2005UALA00396Pad · stuckONE FOAM PAD PACKED UNDERNEATH SLIDE, STUCK TO BOTTLE BAG.SDR 0500616307Blades · bird strikeDURING CLIMB, THE NR 2 ENGINE INGESTED A BIRD. AFTER THE BIRDSTRIKE, THE ENGINE HAD NOTICEABLE VIBRATION. THE ENGINE WAS SHUT DOWN, FUEL WAS DUMPED, AND THE AIRCRAFT RETURNED TO JFK. THE LANDING WAS WITHOUT INCIDENT. MAINTENANCE REPLACED EIGHT PAIRS OF FANSDR 2005UALA00388Odor · detectedCREW ODOR IN CABIN, NOTICED IN AFT CREW REST AREA, SULPHUR LIKE SMELL. CHILLERS SHUT OFF, RECIRCS SHUT OFF & PAX ENT SYSTEM SHUT OFF ODOR STILL EVIDENT. UTILITY BUSSES SHUT OFF AND ODOR STILL EVIDENT. FOUND OUTBOARD OVERHEAD ELECTRONIC UNIT 46HJK BURNED. SDR 2005UALA00383Battery · inoperativeEMERGENCY EXIT LIGHT ON AT 4L AND 4R. LOW BATTERY. REPLACED BATTERY.SDR 2005UALA00384Hose · leakingAFTER LEVEL-OFF A/C LEAK RE-DEVELOPED AND SLOW STEADY PRESSURE DROP. LOCATED OXYGEN HOSE LEAK AT PRESSURE REGULATOR. REPLACED HOSE AND SERVICED CREW OXYGEN BOTTLE.SDR 2005UALA00363Odor · detectedWINDOW HEAT 2L EICAS MSG DISPLAYED. A WEIRD ODOR WAS APPARENT IN THE COCKPIT THEN C/B TRIPPED FOR 2L. NO RESET ATTEMPTED. INVESTIGATED & FOUND LOOSE WINDOW HEAT CONTROL THERMOSTAT WIRING & "WINDOW HEAT 2L" MESSAGE ON EICAS. LOOSE WIRING MAY HAVE CAUSED ARCSDR 2005UALA00361Wire · openLEFT OVERWING EEL LIGHT SECOND FROM TOP AFT BULB INOP. RELAMPED, NO HELP. AFT LAMP OF THE UNIT WAS DISBONDED FROM THE CHASSIS GROUND. RECRIMPED THE CONNECTION AND REESTABLISHED GROUND.SDR 2005UALA00333Warning Light · illuminatedCREW OBSERVED FWD CARGO FIRE WARNING ACTIVATE. CAUSE OF PROBLEM IS UNDETERMINED. SEVERAL ITEMS WERE ACCOMPLISHED TO FIX PROBLEM INCLUDING CH1924 ADRRESSING THE OUTGASSING OF CERTAIN PRODUCE ITEMS THAT ACCORDING TO THE EXPERTS MAY TRIGGER THE FIRE DETECTION SSDR 2005UALA00279Wire · damagedFIRST CLASS ALL LT EELS INOP. REPAIRED WIRING.SDR 2005UALA00373Slide · tornMULTIPLE HOLES AND TEARS IN THE INFLATABLE. CAUSE UNKNOWN, SLIDE REPAIRED PER OEM MAINTENANCE/REPAIR MANUAL.SDR 2005UALA00213Frame · dentedAFT PIT STA 1580, RBL 36 FRAME CAP DENTED. FRAME DENTED BY CARGO LOADING OPERATIONS. FAA-APPROVED PERMANENT REPAIR APPLIED TO FRAME INNER FLANGE.SDR 2005UALA00217Seat Track · damagedCABIN SEAT TRACK AT LBL 33.39 STA 1063-1218 IS FOUND TO BE OUT OF LIMIT AFTER DAMAGE REMOVAL. *S/D* MAJOR REPAIR ACCOMPLISHED. SEAT TRACK SECTIONS REPLACED.SDR 2005UALA00218Seat Track · damagedCABIN SEAT TRACK AT RBL 33.39, STA 1168-1222 FOUND TO BE OUT OF LIMIT AFTER DAMAGE REMOVAL. *S/D* MAJOR REPAIR ACCOMPLISHED. SEAT TRACK SECTION REPLACED.SDR 2005UALA00219Panel · damagedLEFT WING OUTBOARD T/E AFT FLAP PANEL 588JT HAS ELONGATED HOLE. DAMAGE OCCURED DURING MAINTENANCE. REPAIRED PER EA 747-5753-13-A1252.SDR 2005UALA00212Wire · failedEMERGENCY EXIT LIGHTS WILL NOT GO OUT. THE MED 5R SLIDE LIGHT CONDUIT ASSY WAS DAMAGED WHERE CONTACT IS MADE AT THE DOOR CUTOUT. REPLACED WIRE ASSY AND INNER AND OUTER CONDUITS.SDR 2005UALA00210Flange · damagedEXTERNAL POWER RECEPTICLE DOOR FLANGE HAS AN AREA APPROX 0.5 INCH IN DIA, BURNED AWAY FROM HEAVY ARCHING ON LOWER EDGE. SOURCE OF DAMAGE UNCERTAIN. ROUTINE INSPECTION DISCOVERED DAMAGE. REPAIR PROVIDED BY ENGINEERING.SDR 2005UALA00197Floorbeam · dentedAFT PIT FLOOR TEE CHORD FLANGE DENTED AT STA 1780 AND RBL 48. DENT MEASURES 0.5 LONG BY 0.5 WIDE BY 0.06 5 INCH DEEP.SDR 2005UALA00196Girt Bar · malfunctionedDOOR 2 RIGHT GIRT BAR WILL NOT ENGAGE WITH THE ARM SWITCH, WILL ENGAGE BY MAINTENANCE ONLY. CAUSE IS NOT FULLY KNOWN AT THIS TIME. MAY BE CAUSED BY IMPROPER HANDLING OF SLIDE DURING INSTALLATION WHICH RESULTED IN SLIDE PACK BECOMING UNRAVELED AND INTERFERRSDR 2005UALA00194O-Ring · defectiveLOW BOTTLE PRESSURE IN ONE CYLINDER. REPLACED DEFECTIVE O-RING IN REGULATOR.SDR 2005UALA00130Door · noisyAFTER TAKEOFF, LOUD NOISE FROM DOOR 4L. ALSO, EICAS MESSAGE FOR DOOR. EXAMINATION OF THE DOOR DID NOT REVEAL ANY DISCREPANCIES. THE DOOR WAS OPERATED SEVERAL TIMES EACH TIME SATISFACTORILY.SDR 2005UALA00116Structure · crackedLOWER AFT CORNER OF FWD CARGO DOOR CRACKED. DAMAGE WAS CAUSED BY IMPROPER OPERATION OF THE DOOR. DOOR WAS LOWERED ONTO CONTAINER LOADER. DAMAGED SKIN WAS REMOVED, AND THE DOOR WAS REPAIRED.SDR 2005UALA00112Warning Light · false indicationFIRE CARGO FWD MSG ON UPPER EICAS ON FINAL APPROACH. FWD CARGO FIRE BOTTLES WERE DISCHARGED ON ARRIVAL. A CHECK OF THE FORWARD CARGO PIT AFTER LANDING REVEALED NO EVIDENCE OF A FIRE. THE SMOKE DETECTORS WERE COVERED WITH MOISTURE. THIS IS CONSISTENT WITH SSDR S05432042Actuator · damaged9A CHECK FOUND RT WING GEAR RETRACT ACTUATOR ROD END SLEEVE WORN OUT. ROD END BEARING SLEEVE WORN OUT. ACTUATOR REPLACED AND FUNCTION TEST NORMAL. IAW 744 AMM 32-32-01 P.407 AND IPC 32-11-01 FIG.1. WASHERS AND SPACERS SHOULD BE INSTALLED ON BOTH SIDE OF ROSDR 2005UALA00091Slide · failedSLIDE SUFFERED DAMAGE DURING DEPLOYMENT TO INFLATABLE, ABRASIONS ON EXPOSED HOSES AND 3 HOSES FAILED HYDRO TESTING. LEAKING AT THE WELDED AREA ON TUBING. SLIDE DAMAGED DUE TO IMPROPER HANDING AFTER DEPLOYMENT. REPAIRED INFLATABLE HOLES AND REPLACED HOSES.SDR 2005UALA00064Light · inoperativeMOUNTED EEL LIGHT AT SEATS 6AB, 7AB, AND 8AB ARE INOP. REPLACED POWER SUPPLY M6003, TEST OK.SDR 2005UALA00024Door · brokenCHRONIC WRITE UP BANGING IN FLOOR BEHIND DOOR 2L, 5 ROWS BACK ALSO STOP WITH NR 2 PACK OFF. THE NR 2 AIR CONDITIONING PACK INLET DOOR WAS FOUND BROKEN. THE DOOR WAS REPLACED AND THE AIRCRAFT HAS HAD NO FURTHER PROBLEMS.SDR 2005UALA00023Fan · failedELECTRICAL SMELL IN CABIN. SMELL DISSIPATED WITH BOTH RECIRC FANS TURNED OFF. THE UNDER FLOOR LEFT RECIRCULATION FAN MOTOR FAILED. THE FAN WAS REPLACED AND THE AIRCRAFT HAS HAD NO FURTHER PROBLEMS.SDR 2005UALA00016Hydraulic System · leakingFLIGHT LOST ALL QUANTITY IN THE NR 2 HYD SYS. LOSS OF FLUID DUE TO CHAFED THRUST REVERSER RETURN HYDRAULIC LINE. MAINTENANCE ALSO NOTED LEAK AT PUMP FLANGE. LEAK AT PUMP FLANGE POSSIBLY DUE TO PUMP FAILURE DUE TO SUBSEQUENT FLUID STARVATION. SYDMM ACCOMPLISDR 2004UALA01253Fan · failedELEC UTIL BUS R EICAS ADVISORY MESSAGE DISPLAYED. UTILITY BUSS 3 (OR 4) OR GALLEY BUSS 3 (OR 4) DOES NOT HAVE ELECTRICAL POWER ON IT. AIRPLANE IS NOT IN LOAD SHED CONDITION. THE LOWER LEFT RECIRCULATION FAN BEARINGS FAILED. THE FAN WAS REPLACED AND THE AIRCSDR 2004UALA01247Floorbeam · dentedUPPER T-CHORD FWD FLANGE OF AFT CARGO COMPARTMENT FLOORBEAM AT STA 1760, LBL 51 WAS FOUND DENTED. REPAIR ACCOMPLISHED.SDR 2004UALA01248Frame · dentedDENT WAS FOUND ON THE UPPER I/B T-CHORD ON FRAME AT STA 900 APPROX LBL 20 IN THE FWD HORIZONTAL FLANGE OF THE CHORD. REPAIR ACCOMPLISHED.SDR 2004UALA01225Power Supply · dischargedAFT EMERGENCY EXIT SIGN INOP. REPLACED CHARGER AND BATTERY PACK TO DM5934 CONNECTOR.SDR 2004UALA01226Aspirator · misinstalledCRACKED UPPER TUBE ASPIRATOR. ASPIRATOR DAMAGED DUE TO IMPROPER PACKING DURING PREVIOUS OVERHAUL. REPLACED ASPIRATOR.SDR 2004UALA01215Fitting · leakingLOW BOTTLE PRESSURE. CHARGE FILL FITTING LEAKING. REPLACED BOTTLE AND VALVE.SDR 2004UALA01204Power Supply · inoperativeFLASHING EMERGENCY EXIT LIGHTS UPPER DECK FWD OF EXIT DOORS INOP. REPLACED BATTERY PACK FOR LIGHTS.SDR 2004UALA01189Floorbeam · dentedAFT PIT FLOOR SUPPORT STRUCTURE AT STA 1800 HAS DENT AT RBL 22.0. CARGO OPERATIONS PERIODICALLY CAUSES STRUCTURAL DAMAGE IN THE SUPPORT FRAMES. STANDARD REPAIR.SDR 2004UALA01188O-Ring · leaking90 DEGREE ELBOW TUBE ASSEMBLY LEADING WHERE FITTING GOES ON TO THE REGULATOR VALVE AS O-RING. DATA THE SDR DESCRIBES AN AIR LEAK AT THE INTERFACE BETWEEN THE SLIDE BOTTLE REGULATOR ASSEMBLY AND THE 90 DEGREE ELBOW TUBE LEADING TO THE PRESSURE GUAGE. REPLACEDSDR 2004UALA01182Slide · tornDEPLOYED SLIDE, FOUND TEAR IN FLOOR. SLIDE LEAKS IN INFLATABLE AND AT ASPIRATOR FLAPS. SLIDE SENT TO OEM (GOODRICH) FOR REPAIR. REPLACED GIRT AND ASPIRATOR.SDR 2004UALA01171Sensor · malfunctionedALTIMETER SPLIT 240-250 FT WITH RT SIDE READ LOW. THE RT AOA PROBE IS SUSPECTED TO BE PROVIDING ERRONEOUS INDICATIONS TO THE ADC AT HIGH SPEEDS (0.8 - 0.9 MACH). THE AIR DATA COMPUTER TAKES AOA INPUTS TO MAKE CORRECTIONS TO THE PITOT-STATIC PRESSURES. DURIN
Back to Pratt & Whitney PW4056