Pratt & Whitney PW4056
Service difficulty reports · 12,595
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2004UALA00477Lamp · intermittentEMERGENCY EXIT LIGHTS 15-16B, COME ON-OFF FOR NO REASON. RELAMPED AND SECURED BATTERY PACK. NO FLICKERING AT 15-16B AREA. EMERGENCY EXIT LIGHTS TEST OK.SDR 2004UALA00539Slide · deployedFORWARD BOTTLE DISCHARGED WHEN PINS WERE PULLED RESULTING IN SLIDE DEPLOYMENT. UNABLE TO DEFINITIVELY DETERMINE CAUSE OF FAILURE DUE TO PARTIAL DEPLOYMENT OF SLIDE. SUSPECT THAT INFLATION CABLE WAS MISROUTED, RESULTING IN TENSION WHICH DEPLOYED SLIDE WHEN BOSDR 2004UALA00453Frame · crackedAFT PIT FRAME WEB AT STA 2120 RBL 41.33 CRACKED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW WEB SECTION.SDR 2004UALA00454Torque Box · crackedAFT PIT TORQUE BOX WEB BETWEEN STA 1840 - 1860 LBL 61 HAS 1 CRACK AND DENT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW TORQUE BOX WEB.SDR 2004UALA00455Torque Box · dentedFWD PIT TORQUE BOX AT STA 660-680 LBL 25 TO LBL 40 WEB HAS 3 EA DENTS AROUND EXISTING DOUBLER. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW WEB.SDR 2004UALA00456Floor Support · corrodedAFT PIT STA 1920 T-CAP CORRODED FROM RBL 58 TO LBL 58. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW T-CAP SECTION.SDR 2004UALA00457Floorbeam · bentFWD PIT STA 840 RBL 49 FLANGE OF UPPER TEE CHORD IS BENT RBL 8 TO RBL 65. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLES & T-EXTRUSION.SDR 2004UALA00458Frame · dentedAFT PIT FRAME AT STA 1840 LBL 61 HAS DENT AT LOWER SECTION. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW FRAME.SDR 2004UALA00459Floorbeam · bentFWD PIT STA 760 RBL 49 AFT FLANGE OF UPPER TEE CHORD IS BENT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLES AND T-EXTRUSION.SDR 2004UALA00439Warning Light · illuminatedTOP OF DESCENT CREW GOT AFT CARGO FIRE INDICATOR LIGHT. DECLARED EMERGENCY. USED ONE FIRE BOTTLE AND LIGHT DID NOT EXTINGUISH. NORMAL LANDING. PROBABLE CAUSE A COMBINATION OF AN INTERMITTENT SMOKE DETECTOR AND MOISTURE FROM THE CARGO. SMOKE DETECTOR WAS RESDR 2004UALA00410Floorbeam · crackedAFT PIT RT SIDE STA 2120 T-CAP FOR WASTE TANK SUPPORT FITTING CRACKED RBL 41 - 33. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW T-CAP SECTION.SDR 2004UALA00398Stringer · crackedLWR NOSE COMPT LT CRAWL WAY STRINGER 39 BTWN BS 280 AND BS 300 IS DEFORMED AND CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER.SDR 2004UALA00393Door Frame · crackedDOOR 1L MED FRAME CRACKED AROUND CENTER BOX. FABRICATED & INSTALLED REPAIR DOUBLER.SDR 2004UALA00394Structure · dentedFWD CARGO DOOR FWD EDGE 36 INCHES FROM TOP DENTED. FABRICATED & INSTALLED FILLER & DOUBLER REPAIR.SDR 2004UALA00373Frame · dentedAFT PIT FLOOR FRAME T-CAP DENTED AT FRAME 1600 LBL 13. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW T-CAP.SDR 2004UALA00374Skin · buckledMED 5L EXTERIOR SKIN AT FWD LOWER CORNER BUCKLED. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2004UALA00375Skin · dentedEXTERNAL FUSELAGE SKIN HAS DENT AT BS 2188 BTWN S29R & S30R. FABRICATED AND INSTALLED DOUBLER REPAIR.SDR 2004UALA00376Skin · dentedLWR EXTERNAL FUSELAGE SKIN DENTED BS 1814 LBL 12.5. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2004UALA00388Odor · detectedFA REPORTED SMELLING PLASTIC BURNING SMELL/SMOKE. F/A USED A PLASTIC COVER WHILE HEATING FOOD. PLASTIC COVERED FOOD IS NOT LOADED INTO OVENS. F/A SHOULD REVIEW CORRECT PROCEDURES FOR RECON OVENS AND NEVER PLACE ANY PLASTIC ITEMS INTO OVENS.SDR 2004UALA00332Slide · tornSLIDE FAILED PROOF PRESSURE TEST AFTER 3 MINUTES AT 4.2 PSI. THE SEAM BELOW THE GIRT TORE. SLIDE WAS RETURNED TO OEM FOR ANALYSIS, BUT SPECIFIC CAUSE FOR FAILURE WAS INDETERMINATE. INFLATABLE PORTION OF SLIDE WAS SCRAPPED.SDR 2004UALA00323Floorbeam · crackedFWD PIT STA 760 RBL 56 FLOORBEAM CRACKED AND DENTED. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. FABRICATED AND REPLACED SECTION.SDR 2004UALA00307Warning Light · illuminatedON FINAL APPROACH FIRE CARGO AFT CAME ON. CREW USED ONE EXTINGUISHER BOTTLE. EMERGENCY EQUIPMENT STANDING BY. IN ADDITION TO THE "FIRE CARGO AFT" WARNING DURING DECENT, FLIGHT CREW OBSERVED STATUS MESSAGE "AFT CARGO 4 LP B". NRTMM FOUND STORED CMC FAIL MESSSDR 2004UALA00288Skin · dentedBULK CARGO COMPARTMENT SKIN DENTED FROM STRINGER 47L TO 46L AT STA 1936. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED DOUBLER & SPLICE REPAIR.SDR CA040330002Window · cracked(CAN) AIRCRAFT TOTAL TIME 49,175HRS,7715 CYCLES ITEM NOT A TRACKED ITEM.IN FLIGHT, PASSENGER WINDOW AT ROW 31 CRACKED,IT WAS THE OUTER PANE, WITH NO DEPRESSURISATION WINDOW REPLACED.SDR 2004UALA00284Light · intermittentEMERGENCY LIGHTS FLASHING IN ALL ZONES. COULD NOT DUPLICATE. LIGHTS CHECKED GOOD.SDR 2004UALA00253Battery Pack · inoperativeEMERGENCY EXIT LIGHTS AT DOOR 4R INOP AT TWO LOCATIONS. REPLACE BATTERY PACK BASE AND PACK.SDR 2004UALA00235Power Supply · inoperativeEMERGENCY LIGHTS AT SEATS 32, 33, 34 A, B & C COME ON AND OFF INTERMITTENTLY WHILE AT THE GATE. REPLACED POWER SUPPLY UNIT ABOVE 3L.SDR 2004UALA00212Light · inoperativeSLIDE LIGHT INOP AT DOOR 3L. REPLACED & TESTED DOOR SLIDE LIGHT LAMP, TESTS GOOD.SDR 2004UALA00198Frame · corrodedBULK CARGO PIT FRAME STA 1920 UPPER CHORD AFT FLANGE IS EXFOLIATED UNDER NUT PLATES AT LBL 20, RBL 3, 6 & 12, LBL 20, RBL 3, RBL 6, RBL 12. MAJOR REPAIR ACCOMPLISHED. SPLICED IN NEW CHORD SECTION.SDR 2004UALA00199Bulkhead · dentedAFT PRESSURE BULKHEAD (STA 2360) HAS 2 EACH DENTS JUST BELOW WL 274.87 AT RBL 45 AND RBL 55. MAJOR REPAIR ACCOMPLISHED. INSTALLED 2 EACH REPAIR DOUBLERS.SDR 2004UALA00200Frame · corrodedAFT PIT FRAME 1920 T-CHORD EXFOLIATED AT RBL 57. MAJOR REPAIR ACCOMPLISHED. REPLACED CORRODED T-CHORD SECTION.SDR 2004UALA00201Skin · lightning strikeLIGHTNING STRIKE BLENDED OUT OF LIMIT AT STA 190 AND STRINGER 28AL (LEFT). MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED EXTERNAL SKIN DOUBLER.SDR 2004UALA00286Slide · failedDOOR 2 RIGHT SLIDE FAILED OVER PRESSURE TEST AT 3.80 PSI DURING OVERHAUL. SLIDE OEM ANALYSIS OF FAILURE WAS INCONCLUSIVE. INFLATABLE PORTION OF SLIDE SCRAPPED.SDR 2004UALA00168Skin · damagedAFT CARGO DOOR LOWER SKIN DAMAGED AT EDGE. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED FILLER AND DOUBLER.SDR S04472025Engine · surges744 B18273, DURING FINAL APPROACH, AT ALT 4000 FT, AUTO THROTTLE WAS ENGAGED. WHEN THROTTLE ADVANCE FROM IDLE, ENG 1 SURGE AND SPOOL DOWN.C/A: REPLACE ENG 1 VSV ACT. PERFORM MAINT ACTION IAW FIM 71-00-00. CHECK NML.SDR ANCF200400003Engine · surgesRT ENGINE SURGE DURING ACCEL (AFTER SELECTING CLIMB THRUST) AT 5000 FT ENG OPERATION ABNORMAL AFTER SURGE. ENG WAS NOT SHUTDOWN. BOROSCOPE INSPECTION WAS PERFORMED IAW AMM 71-00-00/601, FIM 71-06-00, FIG 105A NEGATIVE TEST, THE ENGINE WILL BE REPLACE ON FEBRUSDR 2004UALA00143Frame · dentedUPPER T-CHORD ON THE FRAME AT BS 720, APPROX RBL 15 HAS A DENT IN THE HORIZONTAL FLANGE OF THE CHORD. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED REPAIR ANGLES, SHIMS AND FILLER.SDR 2004UALA00144Frame · dentedUPPER T-CHORD ON THE FRAME AT BS 1780, APPROX RBL 27 HAS A DENT IN THE HORIZONTAL FLANGE OF THE CHORD. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED REPAIR ANGLE, SHIMS, INTERCOSTAL WEB & FILLERS.SDR 2004UALA00145Fuse · blownRIGHT OVERWING AFT 2 EMERGENCY LIGHTS INOPERATIVE. REPLACED FUSE IN POWER SUPPLY. CHECKS OK.SDR 2004UALA00146Odor · detectedRIGHT ELEC UTIL EICAS MSG WITH ELECTRICAL ODOR IN GALLEY. AFTER SHUTTING DOWN RIGHT UTIL BUS, LEFT BUS TRIPPED. W/U STATES ELECTRIC BURNING ODOR FOLLOWED BY "ELEC UTILITY BUS R" AND THEN BY "ELEC UTILITY BUS L" BOTH UTILITY BUS SW'S SELECTED "OFF" PER FLT MASDR 2004UALA00123Floorbeam · corrodedCORROSION WAS DISCOVERED ON THE UNDERSIDE OF THE FLOORBEAM LOCATED AT STA 1100 FROM LBL 17 TO LBL 30. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR STRAP.SDR 2004UALA00114Floorbeam · damagedAFT CARGO COMPARTMENT FLOORBEAM AT STA 1820 BL0 DAMAGED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED T-CHORD REPAIR.SDR 2004UALA00115Door Frame · crackedRIGHT NR 5 MED, FWD FRAME INBOARD WEB CRACKED AT LOWER DOOR HINGE AREA. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2004UALA00116Door Frame · crackedLEFT NR 5 MED, FWD FRAME INBOARD WEB IS CRACKED AT LOWER DOOR HINGE AREA. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2004UALA00117Floorbeam · crackedUPPER DECK FLOORBEAM WEB IS DENTED AND CRACKED STA 380 RBL 14. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED WEB, TAPER SHIM & STIFFENER REPAIRS.SDR 2004UALA00110Line · chafedFLT HAS HAD NR 1 QTY INDICATION LOSS WITH PSBL HYD PRESS LOSS. AMBER ALERT DECLARED. LOSS OF FLUID DUE TO LANDING GEAR DOWN HYDRAULIC LINE PIN HOLE LEAK. PIN HOLE CAUSED BY CHAFING DUE TO BROKEN CLAMP BACC10CC-8 LOCATED AT STA 900. ACCOMPLISHED RYNGLOK RESDR 2004UALA00091Terminal Block · missingEMERGENCY LIGHT ON DOOR NR 2 LEFT, STAYS ON ALL THE TIME. FOUND GROUND MISSING AT TERMINAL BLOCK. SECURED GROUND TERMINAL. LIGHT ASSY OPS CHECKS OK FOR ALL FUNCTIONS.SDR 2004UALA00044Door · unsecureAFTER TAKEOFF UNABLE TO PRESSURIZE A/C. EICAS CAUTION DOOR AFT CARGO ILLUMINATED. FOUND LATCH CAM MANUAL LOCK HITTING CAM ON AFT CARGO DOOR. RERIGGED LATCH CAM TO ALLOW FOR 0.06 INCH CLEARANCE.SDR S04425003Oven · failed744 B18203, SMOKE FOUND ON STEAM OVEN (508) OF GALLEY UINT 7 WHEN OPERATION OF OVEN. C/A: STEAM OVEN REPLACED AND FUCTIONAL TEST FOUND NORMAL. REMOVED STEAM OVEN WAS FOUND WITH THE SENSOR BOARD BURN OUT CAUSED BY MOISTURE BASED ON THE SHOP REPORT AND NOTISDR 2005UALA00058Door Frame · dentedEXTERNAL POWER RECEPTACLE PANEL DOOR FRAME IS DENTED. FABRICATED & INSTALLED INTERNAL DOUBLER PER EA. INSTALLED SHIMS & FILLERS AS REQUIRED
Back to Pratt & Whitney PW4056