Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2015062994025Connector · unsecureROWS 46C TO 53C SEAT EMERGENCY EXIT LIGHTS INOPERATIVE. SECURED SEAT 51 CONNECTOR IN THE J BOX. OPERATIONS CHECKED OK.SDR CALA2015062994026Connector · unsecureROWS 54H TO 60H SEAT EMERGENCY EXIT LIGHTS ARE DIM. SECURED CONNECTOR AT SEAT 57H. OPERATIONS CHECKED OK.SDR CALA2015062994027Connector · unsecureSEAT 57H EMER EXIT LIGHT INOPERATIVE. SECURED CONNECTOR AT 57H. OPERATIONS CHECKED OK.SDR CALA2015062994029Fuse · blownPER A CHECK LT OVERWING LIGHTS, 2 EACH, AFT INOPERATIVE. REPLACED FUSE ON M7919 EMER LIGHT POWER SUPPLY LOCATED ABOVE DOOR 3L IAW WDM 33-51-42 PAGE 1 SHEET 1. OPERATIONAL CHECK OF ALL 4 EA LT OVERWING EXTERNAL EMER LIGHTS OK.SDR CALA2015062694023Sensor · failedFLAP & SLAT DISAGREE & INTERMITTENT LE EXTEND INDICATIONS FAULT MSG 27-81021 FAILED SENSOR S303. LE SLAT SENSOR NR 9. R & R SENSOR, TESTED NORMAL.SDR CALA2015062294000Reveal · crackedMAIN DECK STATION 2231 R - H, STRINGER 22R - 23R, DOOR REVEAL FOUND CRACK. REPAIRED IAW SRM 53-60-15 REPAIR 3 FIG 203 REV 93.SDR CALA2015062294001Reveal · crackedMAIN DECK STATION 2231 L - H, STRINGER 22L - 23L, DOOR REVEAL FOUND CRACK. REPAIRED IAW SRM 53-60-15 REPAIR 3 FOG 203 REV- 93.SDR CALA2015062494016Reveal · crackedMAIN DECK STATION 2231 RT, STRINGER 22R - 23R, DOOR REVEAL FOUND CRACK. REPAIRED IAW SRM 53-60-15 REPAIR 3 FIG 203 REV 93.SDR CALA2015062494017Reveal · crackedMAIN DECK STATION 2231 LT, STRINGER 22L - 23L, DOOR REVEAL FOUND CRACK. REPAIRED IAW SRM 53-60-15 REPAIR 3 FOG 203 REV- 93.SDR CALA2015061893990Power Supply · defectiveROWS 54 - 61 RT SIDE AISLE EMER LIGHTS & DOOR 5R EMER LIGHT ILLUMINATES INTERMITTENT. IAW FIM 33-51 TASK REPORT PG 302 ITEM 3 FOUND LIGHTS ON DIM INTERMITTENTLY. REPLACED POWER SUPPLY M6012 IAW MM 33-51-04 PG 201. TESTED NORMAL.SDR CALA2015061993997Structure · crackedSTATION 2598 AFT INNER CHORD CRACKED. CF9142 DATED 3/12/12 CAT B. REPAIR ACCOMPLISHED IAW SRM 53-80-08 HAS FAA APPROVAL WITH SUPPLEMENTAL INSPECTION ACCOMPLISHED IAW TABLE II PG 94 OF 97.SDR DALA2015061503759Engine · flamed outDURING CLIMB FROM FL380 TO FL390 ENGINE NR 3 FLAMED OUT. GOT CLEARANCE TO FL300 AND ATTEMPTED RESTART AT FL300, UNSUCCESSFUL. COMPLETED QRH PROCEDURE ENGINE FLAME OUT AT APPROXIMATELY 1740Z. NR 3 ENGINE OIL PRESSURE STAYED AT 12-14 REST OF FLT NR 3 ENGINE CSDR CALA2015061593917Latch · out of adjustREF EA 2560 02662 OP 1 LT OFF WING ESCAPE SLIDE DOOR LATCH CHECK FAILED, EXCEEDS 175 INCH POUNDS STEP 5 IAW EA OP3 MUST NOW BE COMPLIED WITH. COMPLIED WITH OP 001 EA 2560-02662. LT OFF WING ESCAPE SLIDE DOOR LATCH & DISCONNECT HOUSING INSPECTION.SDR CALA2015061593913Battery · dischargedOVER THE WING EMER EXIT LIGHT 2 LT FWD ARE INOPERATIVE. REPLACED BATTERY PCN 563-1188 & CHARGER PCN 563-1046 IAW AMM 33-51-04. OPERATIONS CHECKED GOOD IAW AMM33-51-04 PG 207-208. ALSO RELAMPED & CLEANED LAMP SOCKETS.SDR CALA2015061593914Light · inoperativeOVER THE WING EMERGENCY EXIT LIGHT 2 RT FWD LIGHTS ARE INOPERATIVE. REPLACED RT FWD OVERWING LIGHT. OPERATIONS CHECKED GOOD.SDR CALA2015061193889Bar · damagedNUMBER 5 FLAP TRACK FAIL SAFE BAR DAMAGED. BUSHING & TOOLING HOLE ELONGATED. REPAIR ACP IAW 747EN-57-0184. DVI AFFECTED AREA OF FAILSAFE BAR & REPAIR BUSHING FOR CORROSION, CRACKS & OTHER REPAIR DEGRADATION AT EVERY C-CHECK, NOT TO EXCEED 24 MONTHS. SEE UASDR CALA2015061193891Light · inoperativeEMERGENCY EXIT LIGHT ON 4A IS INOPERATIVE. REPLACED LIGHT ASSEMBLY. OPERATIONS CHECKED OK.SDR CALA2015061193892Light · inoperativeEMERGENCY EXIT LIGHT ON SEAT 43H IS INOPERATIVE. REPLACED LIGHT ASSEMBLY. OPERATIONS CHECKED OK.SDR CALA2015061193893Connector · looseEMERGENCY SEAT 33C IS INOPERATIVE. FOUND CONNECTOR LOOSE, RECONNECTED. OPERATIONS CHECKED OK.SDR CALA2015061193894Connector · looseEMERGENCY LIGHT ON SEAT 48C IS INOPERATIVE. SECURED THE CONNECTOR. OPERATIONS CHECKED OK.SDR CALA2015061193895Connector · damagedEMERGENCY EXIT LIGHTS ON 45A-53A ARE ALL DIM. REPAIRED OTHER SEATS LIGHT ASSEMBLY CONNECTOR. ALL LIGHTS ARE WORKING GOOD.SDR CALA2015061193896Battery · dischargedEMERGENCY EXIT LIGHT SEAT 45H - 53H ARE DIM. REPLACED BATTERY ASSEMBLY AT DOOR 4. OPERATIONS CHECKED OK.SDR CALA2015061193897Connector · unsecureEMERGENCY EXIT LIGHT SEAT 57C IS INOPERATIVE. SECURED LIGHT ASSEMBLY CONNECTOR. OPERATIONS CHECKED OK.SDR CALA2015060893872Connector · defectiveELECTRIC SMELL IN CABIN DURING TAKEOFF IAW AMM 05-51-56-201. FOUND 7JK CEILING LIGHT BALLAST CONNECTOR SMELL. REPLACED BALLAST & REMOVED ELEC CONNECTOR.SDR CALA2015052993842Loop · defectiveRIGHT DUCT LEAK LIGHT & RT BLD DUCT LEAK EICAS MSG LIGHT STAYS ON WHEN ENG BLD SWITCH IS OFF & ISOL VLVS ARE CLOSED. REPLACED LOOP TS214 IAW MM 26-18-01. OPERATIONS TESTED GOOD.SDR CALA2015052193805Connector · brokenPER A CHECK, SEAT EEL AT 35ABC, INOPERATIVE. FOUND CONNECTOR LOCK BROKEN. REPLACED CONNECTOR & PINS. OPERATIONS CHECKED OK.SDR CALA2015052193806Light · inoperativePER A CHECK, SEAT EEL AT 48ABC, INOPERATIVE. REPLACED SEAT EEL AT 48A. OPERATIONS CHECKED OK.SDR CALA2015052193807Light · inoperativePER A CHECK, SEAT EEL AT 49HJK, INOPERATIVE. REPLACED SEAT EEL STRIP. OPERATIONS CHECKED OK.SDR CALA2015052193808Pin · backed outPER A CHECK SEAT EEL AT 19HJK, INOPERATIVE. FOUND ONE PIN ON POWER CABLE COMING FROM WALL PUSHED IN. SECURED PIN, OPERATIONS CHECKED OK.SDR CALA2015052693814Connector · brokenPER A CHECK, SEAT EMER EXIT LIGHT AT 35ABC, INOPERATIVE. FOUND CONNECTOR LOCK BROKEN. REPLACED CONNECTOR & PINS. OPERATIONS CHECKED OK.SDR CALA2015052693815Light · inoperativePER A CHECK, SEAT EMER EXIT LIGHT AT 48ABC, INOPERATIVE. REPLACED SEAT EMER EXIT LIGHT. OPERATIONS CHECKED OK.SDR CALA2015052693816Light · inoperativePER A CHECK, SEAT EMER EXIT LIGHT AT 49HJK, INOPERATIVE. REPLACED SEAT EMER EXIT LIGHT STRIP. OPERATIONS CHECKED OK.SDR CALA2015052693817Pin · backed outPER A CHECK, SEAT EMER EXIT LIGHT AT 19HJK, INOPERATIVE. FOUND ONE PIN ON POWER CABLE COMING FROM WALL PUSHED IN, SECURED PIN. OPERATIONS CHECKED OK.SDR CALA2015051893794Wire · brokenTWO EACH WALL MOUNTED EEL AT AFT GALLEY INOPERATIVE. FOUND BROKEN WIRE AT POWER HARNESS AT PIN ON CONNECTOR. REPLACED PIN. OPERATIONS CHECKED OK.SDR CALA2015051893795Battery · dischargedLEFT OVERWING EEL, TWO EACH LIGHT ASSEMBLY AFT INOPERATIVE. REPLACED EEL BATTERY 563-1188 & EEL BATTERY CHARGER 563-1046 IAW AMM 33-51-04 PB 201. OPERATIONS CHECKED GOOD.SDR CALA2015051893796Light · failedRUBBER BURNING SMELL IN UPPER DECK GALLEY ELEVATOR, SUSPECT FAILED LIGHT ASSEMBLY. REPLACED ASSEMBLY, NO FURTHER BURNED SMELLS DETECTED.SDR CALA2015051593783Unknown · odorELECTRICAL BURNING SMELL NEAR UPPER DECK LAVATORIES. ACCOMPLISHED CABIN CONDITIONAL INSPECTION MX PRACTICES IAW MM 05-51-56-201. SMELL DISAPPEARED.SDR CALA2015051593785Light · intermittentDOOR 4L EXIT LIGHT FWD OF DOOR, ON OFF CYCLING THROUGHOUT FLIGHT, ROWS 43 - 53 ABC. OPERATIONS TEST ACP IAW AMM 33-51-00 & SERVICE TIP IN FIM 33-51. OPERATIONS NORMAL.SDR CALA2015051593789Light · intermittentDOOR 2L, EMER LIGHT ON OFF INTERMITTENTLY. REPLACED MULTIPLE LIGHT POWER PACKS & CHARGERS NOTED ON OTHER ENTRIES PLUS M1561 IAW AMM 33-51-07. LIGHTS OPERATION CHECKED GOOD, NO DEFECTS NOTED.SDR CALA2015051593791Duct · disconnectedDIVERT DUE TO RT BLEED DUCT LEAK EICAS MSG. FOUND AIR DUCT DISCONNECTED AT R2. ADOMG EDGE FLAP PDU. R & R SEAL & SECURED DUCT IAW AMM 27-81-03 201. LE FLAP OPERATIONS CHECKED OK.SDR CALA2015050893696Battery · dischargedPER A CHECK, ROW 19 TO 22 LT, INOPERATIVE BATTERY. OPERATIONS CHECKED GOOD.SDR CALA2015050893697Light · inoperativePER A CHECK, EEL AT SEAT 35 LT, INOPERATIVE. REPLACED EEL SEAT AT 35 LT. OPERATIONS CHECKED OK.SDR CALA2015051193757Connector · unsecurePER A CHECK , SEAT 48 LT, SEAT EEL INOPERATIVE. SECURED UNDER SEAT CONNECTION & LIGHT OPERATIONS NORMAL.SDR CALA2015050793685Light · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE AT SEAT ROW 56H. REPLACED EEL STRIP IAW MM 33-51-12-201-C03.SDR CALA2015050693663Connector · looseEMERGENCY PATH LIGHT AT SEAT ROW 25H INOPERATIVE. SECURED LOOSE CONNECTOR AT ROW 25H. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-00.SDR CALA2015050493650Skin · crackedON WALK AROUND DURING NR 2 SERVICE CHECK, FOUND A CRACK ON RT INBD SIDE OF RT ELEVATOR, ABOUT 4 INCHES FROM INBD EDGE. REMOVED DAMAGE AREA IAW SRM 51-70-04 REPAIR GENERAL, PARA 5 C 1. COMPLETED STEPS 5 C 2 & 5 C 3 IAW SRM 51-70-04. GENERAL INSTALLED TE FASTSDR CALA2015050193643Wire · damagedOPERATIONAL CHECK ON PAX CABIN LIGHTS & SIGNS. REPAIRED WIRE AT SEAT 40 CTR ON EMER LIGHT PATH LT SIDE. SYS CHECKED NORMAL IAW MM 33-51-00.SDR CALA2015042393626Skin · corrodedCEC COMPARTMENT BS 840 - 860, STRINGER 47L - 47R SKIN CORROSION. SKIN CORROSION REPAIRED IAW ECRA 5330-05102.SDR CALA2015042393627Skin · damagedAD 90-25-05, FUS BS 1740 - 1960, STRINGER 46L - 46R BELLY SKIN FOUND PITTING. DAMAGED BELLY SKIN, PITTING DAMAGE REPAIRED IAW ECRA 5330-05103.SDR CALA2015042393628Skin · damagedFUSE BELLY SKIN BS 520 - 740, STRINGER 44L - 44R HAS PITTING DAMAGE & EXISTING REPAIR DOUBLER BETWEEN BS 620 - 640 & STRINGER 44R - 46R. CF90 48, NOT IAW CURRENT SRM 53-00-01 REPAIR 1. REMOVED, REPLACED DOUBLER & REPAIR SKIN PITTING DAMAGE IAW ECRA 5330-0511
Back to Pratt & Whitney PW4056