Pratt & Whitney PW4060
Service difficulty reports · 7,186
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA01885Frame · corrodedAFT CARGO COMPT AT BS 1219 AND RBL 33, FRAME T-CAP IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED T-CAP.SDR 2008UALA01886Frame · corrodedAFT PIT AT BS 1197+132 AND LBL 40 FRAME T-CAP IS CORRODED UNDER AND AROUND NUT PLATE. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED T-CAP.SDR 2008UALA01887Frame · corrodedAFT PIT AT BS 1197+88 AND LBL 40 FRAME T-CAP IS CORRODED UNDER AND AROUND NUT PLATE. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED T-CAP.SDR HALA0800481Circuit Card · malfunctionedETOPS SIGNIFICANT SYSTEM, EICAS L ENG BLEED OFF ILLUMINATED. T/S PER FIM 36 -10 00 CHECKED CONNECTORS AND SENSE LINES AT PRSOV, PRV, HPSOV AND FAMV NO TROUBLE FOUND RE-SEATED BLEED AIR CONTROL CARD RAN LEFT ENG PRSOV, OP CK GOOD PNEUMATICS, OP NORMAL NO FAULTSDR 2008UALA01866Module · brokenLAV 124 OXYGEN MASK COMPARTMENT DOOR BROKEN OFF AND MASK FELL DOWN. REPLACED PASSENGER OXYGEN MODULE. AC OK FOR SERVICESDR 2008UALA01820Stiffener · crackedBS 246 FLOORBEAM AT APPROX RBL 16 HAS A CRACKED VERTICAL STIFFENER. MAJOR REPAIR ACCOMPLISHED, REMOVED AND REPLACED STIFFENER.SDR 2008UALA01821Frame · damagedFRAME IS TORN OUT STA 1351 BETWEEN STR 28R-26R. REPAIRED FRAME IAW SRM 53-00-01 FIG 201 DETAIL II AND SRM 51-40-02. AC OK FOR SERVICE.SDR 2008UALA01822Shear Tie · corrodedAFT CARGO PIT, BS 1197+66 BETWEEN S-39L-39R, SHEAR TIE IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED SHEAR TIE.SDR 2008UALA01823Shear Tie · corrodedAFT CARGO COMPARTMENT AT BS 1197+88 BETWEEN S-39L-39R SHEAR TIE IS CORRODED. MAJOR REPAIR ACCOMPLISHED, REMOVED AND REPLACED SHEAR TIE.SDR 2008UALA01840Idg · malfunctionedR GEN DRIVE LIGHT ON CONTINUOUSLY. REPLACED NR 2 ENG IDG. OP CHECKED AND LEAK CHKD OK. A/C OK FOR RETURN TO SERVICE.SDR HALA0800472Blade · damagedETOPS SIGNIFICANT SYSTEM, RT ENG FAN BLADE 25 HAS NICK. REPAIRED PER AMM TSK 72-31-02, EDDY CURRENT GOOD. EDDY CURRENT CHECKED. NO CRACKS IND NOTED.SDR HALA0800473Blade · damagedETOPS SIGNIFICANT SYSTEM, RT ENG FAN BLADE 22 HAS NICK. REPAIRED PER AMM TASK 72-31-02. EDDY CURRENT GOOD. NO CRACKS IND NOTED.SDR HALA0800474Blade · damagedETOPS SIGNIFICANT SYSTEM, LT ENG FAN BLADE HAS NICK ON NR 18. REPAIRED PER AMM 72-31-02. EDDY CURRENT CHECKED. NO CRACKS IND NOTED.SDR HALA0800475Blade · damagedETOPS SIGNIFICANT SYSTEM, LT ENG FAN BLADE HAS NICK ON NR 17. REPAIRED PER AMM 72-31-02. EDDY CURRENT CHECKED. NO CRACKS IND NOTED.SDR HALA0800476Blade · damagedETOPS SIGNIFICNAT SYSTEM, LT ENG FAN BLADE HAS NICK NR 36. REPAIRED PER AMM TASK 72-31-02. EDDY CURRENT GOOD. NO CRACKS IND NOTED.SDR HALA0800477Fan Blade · damagedETOPS SIGNIFICANT SYSTEM, LT ENG FAN BLADE NR 25 HAS NICK. REPAIRED PER AMM TASK 72-31-02. EDDY CURRENT GOOD. NO CRACKS IND NOTED.SDR HALA0800443Blade · damagedOPEN - BIRD STRIKE INSPECTION OF RT ENG REVEALED A CORNER PIECE MISSING FROM ENG STATOR VANE PLATFORM BASE AT 3 O'CLOCK POSITION. OK TO OPERATE IAW AMM 72-33-02-206--00-N00 TABLE 603. TRANSCRIBED TO MIC SHEET, NO OTHER DAMAGE NOTED AS PER FIM 71 FAULT INDES,SDR 2008UALA01784Idg · failedL GENERATOR DRIVE LIGHT ILLUMINATED. LOST LEFT GENERATOR. NR 1 ENGINE IDG DISCONNECTED DUE TO FAULTS. REPLACED IDG AND GEN CONTROL UNIT (PRECAUTIONARY). GENERATING SYSTEM OP CHKD OK FOR SERVICE.
SDR 2008UALA01790Oxygen Mask · leakingF/O OXYGEN MASK LEAKS FROM THE HEADBAND.SDR 2008UALA01760Gcu · faultedEICAS MSG L GEN OFF DISPLAYED. SUSPECT FAULTY BEARING IDG. REPLACED GENERATOR PER AMM24-11-01 AND GCU PRECAUTIONARY OPS CHECKED NORMAL. ACFT OK FOR SERVICE.SDR 2008UALA01808Contact · damagedEXTERIOR EMERGENCY LIGHT AFT OF RT WING INOP. SUSPECT BAD CONTACT. CLEANED CONTACT OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01750Light · unsecureEMERGENCY LIGHT STRIP COMING UP AT RT SIDE OF BUS GALLEY AT ROWS 10E-F.
SDR 2008UALA01759Warning System · activatedAPU GEN OFF EICAS MSG WITH ASSOC SWITCH LIGHT ILLUMINATED.SDR 2008UALA01721Slide · faultyFOUND DOOR L1 SLIDE IS UNLACED.SDR 2008UALA01722Idg · disconnectedEICAS MSG L GEN DRIVE DISPLAYED. GEN DRIVE LIGHT ILLUM. GEN DRIVE DISCONNECTED.SDR 2008UALA01694Housing · crackedLT OVERWING SLIDE COMPARTMENT DOOR DISCONNECT HOUSING CRACKED AT WELD SEAM.SDR HALA0800429Warning System · malfunctionedETOPS SIGNIFICANT SYSTEM, IMMEDIATELY AFTER ENGINE START. EICAS MSG "L GEN OFF" DISPLAYED. L GEN OFF LT ILLUMINATED. CONDITION RETURNED TO NORMAL AFTER GEN SW RESET. ACCOMPLISHED FIM 24-20-00 FIG 101. NO DEFECTS NOTED. RAN NR 1 ENGINE ON GND, LT GENERATOSDR 2008UALA01675Light · inoperativeEMERGENCY FLOOR LIGHTS BY RIGHT OVERWING INOPERATIVE.
SDR 2008UALA01703Light · faultyEMERGENCY EXIT LIGHTS ROW 15-18 FLASH ON AND OFF.SDR HALA0800418Rod End · damagedETOPS SIGNIFICANT SYSTEM, ENG THRUST LEVERS MISALIGNED IN NORM MODE IN LEVEL FLT AT FL 390 WITH EPR'S MATCHED AT 1.37 AND N1 AT 86.3, THRUST LEVERS SPLIT ONE FULL KNOB APART, R THRUST LEVER LAGS. CHECKED THRUST LEVERS AND RESOLVER ANGLES ALL OK. FOUND RT INPSDR 2008UALA01654Light · faultyEMERGENCY EXIT LIGHTS FLASH ON AND OFF IN COACH AISLE LEFT SIDE ONLY.SDR DL76L080400Case · crackedNR 1 ENG CHANGE DUE TO FAN CASE CRACK.SDR 2008UALA01614Light · intermittentEMERGENCY EXIT ROW LIGHTING COMES ON SPORADICALLY FROM ROW 27AB TO DOOR 2L.SDR 2008UALA01658Bottle · reads lowESCAPE SLIDE BOTTLE LOW .SDR 2008UALA01583Switch · faultyLEFT ENGINE FIRE HANDLE AND L ENGINE FUEL CONTROL FIRE LIGHTS CAME ON, ENG NOT RUNNING AND IN. SUSPECT APU CARGO OVERHEAT SWITCH. REPLACED ENGINE APU CARGO OVERHEAT TEST SWITCH. GROUND CHECK NORMAL. AC OK FOR SERVICE.SDR 2008UALA01556Light · intermittentEMERGENCY PATH LIGHTS IN COACH ON THE RIGHT SIDE COMES ON INTERMITTENTLY.SDR 2008UALA01584Warning Light · illuminatedNR 2 ENG 'ENG CONTROL' MESSAGE APPEARED ON EICAS WITH EEC IN NORMAL MODE. RECURRED ON SUBSEQUENT FLIGHT.SDR 2008UALA01585Light · missingEMERGENCY LIGHT ON FLOOR 1E PLASTIC IS MISSING.SDR 2008UALA01586Lamp · inoperativeLIGHT OUT IN FWD LAV.
SDR UALA2008111301584Eec · malfunctionedNR 2 ENG 'ENG CONTROL' MESSAGE APPEARED ON EICAS WITH EEC IN NORMAL MODE. RECURRED ON SUBSEQUENT FLIGHT. *S/D* REPLACED NR 2 ENGINE EEC ALTERNATOR, EEC AND N1 TRANSDUCER. OPS CHECK NORMAL.SDR DL76L080389Bearing · leakingDUE TO HOC INSPECTED FOR LEAK FOUND NR 3 BEARING LEAKING. REPLACING ENGINE NR 2 ENG.SDR 2008UALA01533Warning Light · illuminatedAILERON LOCKOUT EICAS SLOWING THRU 270 AT 11000.SDR 2008UALA01534Light · inoperativeRIGHT IDG DRIVE LIGHT INOP.SDR 2008UALA01561Light · brokenEEL STRIP BROKEN BY MID GALLEY. REPLACED SPLICES, CRIMPER AND PLASTIC COVER. CHECKED EMERGENCY LIGHT OK.SDR 2008UALA01487Sign · faultyEMERGENCY EXIT LIGHT IN COCKPIT IS ON WHEN SWITCH IS IN ARMED POSITION WHILE ON GROUND. REPLACED PORTABLE EMERGENCY EXIT SIGN ABOVE FLIGHT DECK DOOR PER MM 33-51-01. OPS CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA01488Battery Pack · dischargedALL FOUR INTERIOR OVERWING EMERGENCY EXIT SIGNS INOP. REPLACED BATTERY PACK. OPS CHK'D OK.SDR WRLA2008030Seat Track · crackedDURING C-CHECK INSPECTION FOUND MAIN DECK FLOOR PANEL SUPPORT SEAT TRACK CRACKED STA Y=755 X=+75.25. REPAIRED PER SRM VOL.III 53-70-00 FIGURE 1 REV.40.SDR 2008UALA01371Bulb · inoperativeDOOR 2 LEFT EXTERIOR EMERGENCY EXIT LIGHT INOP. SUSPECT BURNED OUT BULB. REPLACED LAMP OPS CHECKED GOOD. AC OK FOR SERVICE
SDR HALA0800399Blade · nickedETOPS SIGNIFICANT SYSTEM, SMALL NICK FOUND ON NR 1 ENG ON NR 7 FAN BLADE APPROX 5 INCHES FROM BLADE ROOT AREA C. REPAIRED FAN BLADE BY BLENDING AND PERFORMING FPI PER MM 72-31-02-308-003-N00.
SDR 2008UALA01366Skin · corrodedAFT PIT STA 1088 BETWEEN STR 39L AND STR 39R, SKIN IS CORRODED. MAJOR REPAIR ACCOMPLISHED @ GSO: REMOVED DAMAGED AREA FABRICATED REPAIR AND INSTALLED.
Back to Pratt & Whitney PW4060