Pratt & Whitney PW4060
Service difficulty reports · 7,186
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA01367Wire · exposedEMERGENCY LIGHT STRIP ON FLOOR ROW 14B IS PULLED UP W-WIRES SHOWING. REPAIRED LIGHT BAR OPS CHECKED GOOD. AC OK FOR SERVICE.SDR HALA0800384Blade · nickedETOPS SIGNIFICANT SYSTEM, SMALL NICK FOUND ON LEADING EDGE OF NR 2 ENG, BLADE NR 23 APPROX 6 INCHES FROM ROOT. REPAIRED BY BLENDING PER AMM 72-31-02-308-003-N00. PERFORMED DYE PEN INSP ON REPAIRED AREA, NO TROUBLE FOUND.
SDR 2008UALA01326Mask · crackedSMOKE MASK ON CAPTAIN'S SIDE IS CRACKED.SDR 2008UALA01331Bottle · lowLOW BOTTLE PRESSURE.SDR 2008UALA01348Light · damagedEMERGENCY LIGHT BAR AT AFT GALLEY AREA LEFT SIDE IS DAMAGED. REPLACED EEL STRIP OPS CHECKED GOOD. AC OK FOR SERVICE.
SDR 2008UALA01349Light · damagedEMERGENCY LIGHT BARS AT FWD AND MID CROSSAISLE ARE DAMAGED. REPAIRED AND REPLACED LIGHT BARS OPS CHECKED GOOD. AC OK FOR SERVICE.
SDR 2008UALA01350Light · damagedEMERGENCY LIGHT BAR AT MID RIGHT LAV IS DAMAGED. REPAIRED LIGHT STRIP OPS CHECK GOOD. ACFT OK FOR SERVICE.SDR 2008UALA01351Light · damagedEMERGENCY LIGHT BARS AT FWD RIGHT LAV, MID LEFT LAV, AND BOTH AFT LAVS ARE DAMAGED. REPAIRED AND REPLACED LIGHT BARS OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR 2008UALA01295Control Valve · fodLEFT PACK FAILED ON TAKEOFF WITH PACK INOP AND PACK OFF DISPLAYED RESET NORMAL BUT HAD PLASTIC BURNING SMELL AND ALSO A RATTLING SOUND IN DUCTING AREA ABOVE SEAT 9C. CREW SELECTED PACK OFF AGAIN AND BURNING SMELL AND RATTLE STOPPED. FOUND LEFT PACK CONTROL VSDR 2008UALA01325Light · looseEMERGENCY EXIT PATH LIGHTING IN FIRST CLASS IS LOOSE. SECURED LIGHT OPS CHECKED GOOD. AC OK FOR SERVICE.SDR HALA0800395Bracket · crackedAPPROX 1/2" CRACK TO LIGHT STRUCTURE BRACKET RT ENGINE STRUT NAC STA 298.93 - 297, INBD SIDE ATOP AND FWD OF PANEL 447 ELX. BRACKET MEASURES APPROX 3 INCHES BY 1 INCH AND ATTACHES STRUT AFT TORQUE BOX TO SIDE PANELS, FWD AND ABOVE HYDRAULIC SHUTOFF VALVE. RESDR 2008UALA01281Actuator · leakingCENTER HYD QTY DROPPING AFTER START. FOUND SPOILER ACTUATOR NR 9 LEAKING FROM PISTON'S BODY. LEAKAGE BEYOND DISPATCH LIMITS.SDR 2008UALA01311Terminal Block · damagedNR 1 ENG IDG FEEDERS SHOW SIGNS OF HEAT DAMAGE AT TERMINALS. FOUND DAMAGED TERMINALS AT IDG TERMINAL BLOCK. REPLACED TERMINALS. AC OK FOR SERVICE.SDR 2008UALA01312Wire · misinstalledNR 2 ENGINE IDG WIRE LUGS ARE IMPROPERLY CRIMPED, MULTIPLE WIRE STRANDS BROKEN AT CRIMP POINT. REMOVED AND REPLACED IDG FEEDERS FROM PRODUCTION SPLICE AND REPLACED TERMINALS. OPS CHECK PERFORMED & INSPECTED.SDR 2008UALA01313Feeder Cable · brokenEEL FEEDER AT STA 1000L IS BROKEN. REPLACED EEL FEEDER OPS CK GOOD. AC OK FOR SERVICE.SDR 2008UALA01314Light · damagedEEL LIGHTING INOP BY SEAT 14B. ACP PERMANENT REPAIR TO EEL LIGHT STRIP OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01310Bracket · debondedAFT OVERWING EMERGENCY LIGHT BRACKET DISBONDED.SDR 2008UALA01258Frame · crackedFWD PIT FRAME WEB CRACKED AT BS 456 LBL 28. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED NEW WEB.SDR 2008UALA01265Connector · unsecureDOOR 2 LEFT EXTERIOR EMERGENCY EXIT LIGHT INOP. RESECURED CONNECTOR.
SDR 2008UALA01267Connector · damagedLEFT HYDRAULIC SUPPLY SHUTOFF VALVE DOES NOT CYCLE (MOVE) WHEN ENGINE FIRE HANDLE IS PULLED. FOUND CONNECTOR D44045 DAMAGED SUSPECT IMPROPERLY INSTALLED. REPLACED CONNECTOR OPS CHECKED GOOD IAW MM 29-11-06. AC OK FOR SERVICE.SDR 2008UALA01268Fire Loop · no testFOUND CARGO FIRE TEST FAILED CARGO FWD HEAT INHIBIT.SDR HALA0800372Attach Bracket · gougedNR 2 ENGINE NOSE INLET COWL TO FAN CASE ATTACHMENT BRACKET AT 2 O'CLOCK POSITION GOUGED. DAMAGE ON NOSE COWL AFT BULKHEAD INNER RING BLENDED IAW SRM 54-11-02/1A01, FIG. 101, DETAIL 111, WITHIN SRM LIMITS.SDR 2008UALA01174Skin · corrodedFOUND CORROSION ON CENTER WING UPPER SURFACE AT BS 965, BL0. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION. FABRICATED & INSTALLED REPAIR SHIMS. ACCMP HFEC OF HOLES, NO DEFECT NOTED OVER SIZED HOLES.SDR 2008UALA01191Structure · chafedNR 2 PYLON RIGHT SIDE IS CHAFED IN 5 SPOTS AT NAC 195. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA, FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2008UALA01153Power Cable · damagedEEL ADJACENT TO DR 1R INOP. REPAIRED POWER CABLE.SDR 2008UALA01093Connector · damagedNR 2 PYLON J BOX CONNECTOR D4256J IS DAMAGED BY HEAT. REPLACED CONNECTOR D4256J PER BSWPM 20-63-13. OPS CHECK ACCOMP.SDR 2008UALA01095Connector · damagedNR 2 PYLON J BOX CONNECTOR D4148J IS DAMAGED BY HEAT. REPLACED CONNECTOR D4148J PER BSWPM 20-63-13. OPS CHECK ACCOMP.SDR 2008UALA01096Connector · damagedNR 2 PYLON J BOX CONNECTOR D4236J IS DAMAGED BY HEAT. REPLACED CONNECTOR D4236J REF BSWPM 20-63-13. OPS CHECK ACCOMP.SDR 2008UALA01097Frame · corrodedAFT CARGO PIT AT BS 1197 +22 LBL 38 TO LBL 44 FRAME T-CAP HAS CORROSION UNDER SIDE OF CAP. FOUND TO BE OUT OF LIMITS. REMOVED ENTIRE "T" CORD. INSTALLED NEW "T" CORD REF SRM 51-40-02.SDR 2008UALA01098Floorbeam · crackedMAIN CABIN AT STA 266.5 FLOORBEAM AT RBL 70.5 IS CRACKED ON UPPER FLANGE. REMOVED DAMAGE SECTION OF "T" CAP, INSTALLED "T" CORD AND 2 EA REPAIR ANGLE PER SRM 53-00-5 1, RPR 6. DAMAGE REMOVED STA 266.5, RBL 71 TO 49.SDR 2008UALA01099Connector · damagedNR 2 PYLON J BOX CONNECTOR D4240J IS DAMAGED BY HEAT. REPLACED CONNECTOR D4266J PER BSWPM 20-63-13. OPS CHECK ACCOMP.SDR 2008UALA01148Frame · gougedAFT PIT FRAME WEB GOUGED, STA 1351, STR 24R - 25R.
SDR 2008UALA01149Frame · corrodedAFT CARGO PIT AT BS 1197 +44 LBL 22 TO RBL 9 FRAME T-CAP HAS CORROSION UNDER NUT PLATE ATTACH FASTENER HOLES.SDR 2008UALA01085Floorbeam · corrodedMAIN CABIN FLOORBEAM STA 287, RBL 70.5 UPPER FLANGE IS CORRODED.SDR 2008UALA01087Light · brokenEEL LIGHT COVER ON FLOOR AT 13AB AND 14AB IS PULLED UP. SUSPECT NORMAL CREW AND PASSENGER BOARDING AND DEBOARDING. SPLICED IN NEW EEL STRIP OPS CHECK GOOD. AC OK FOR SERVICE.SDR DL76P081248Engine · failedCREW REPORTS LOSING N2 INDICATIONS ALONG WITH A C1 MESSAGE EN ROUTE TO HNL ON FLT 1465. WHEN PMA STATOR REMOVED MTC NOTED THE PMA ROTOR DRIVE HAS FAILED. REPLACED RT ENGINE PMA.SDR HALA0800351Unknown · unknownETOPS SIGNIFICANT SYSTEM, ON DESCENT THROTTLES 1 INCH DIFFERENCE WITH SAME EPR. PERFORMED MCDP GRD TEST 02-10 ALSO COMPARED THROTTLES POSITION ON THE EPCS PAGE. THE TRA AND EPR POS CHECKED OK, NO FAULTS WITH THROTTLES POS, ACCOMPLISHED PIMU BITE CHK. ALSO NSDR 2008UALA01086Sensor · out of adjustAN 'AIR-GND DISAGREE' EICAS MSG DISPLAYED. PERFORMED THE MM32-09-07-210 AIR-GRD SENSOR TEST IN AIR MODE BY JACKING THE ACFT. FOUND S268 TILT SENSOR OUT OF RANGE PER MM 32-61-99 PG 601. REPLACED S268 TILT SENSOR. ACFT OK FOR SERVICE.SDR 2008UALA01021Stiffener · crackedLEFT VERTICAL STIFFENER CHORD, NLG WW, STA 287 HAS 3" CRACK, INDICATION LOCATED 10.75" FROM THE NOSE WW TOP PANEL.SDR 2008UALA01024Light · faultyEMERGENCY EXIT LIGHT AT FLIGHT DECK DOOR IS ON WITH STANDBY SWITCH IN OFF POSITION.SDR 2008UALA01028Hose · leakingTHE 2ND OBS OXYGEN HOSE IN STORAGE BOX LEAKS. SUSPECT DAMAGED FROM PRE FLIGHT CHECKS. REPLACED MASK AND BOX PER MM35-11-51. OPS CKD NORMAL. AC OK FOR SERVICE.SDR 2008UALA01009Insert · out of positionRIGHT OVERWING SLIDE INFLATION HOSE CLAMP INSERT PULLED OUT.SDR 2008UALA01008Battery · dischargedEMERGENCY LIGHTS ON LEFT + MID SIDE OF 1ST CLASS GALLEY + LEFT SIDE OF CABIN FROM 1L TO MID LAVS. REPLACED EEL BATTERY.SDR 2008UALA00982Gcu · faultyEICAS MSG R GEN OFF DISPLAYED. R GEN OFF AND FIELD OFF LGT'S ILLUMINATED. SUSPECT FAULTY GENERATOR CONTROL UNIT. REPLACED ENGINE NR 2 GCU PER AMM 24-22-02, CHECKS NORMAL. AC OK FOR SERVICE.SDR 2008UALA00981Housing · crackedRIGHT OVERWING SLIDE DISCONNECT HOUSING IS CRACKED.SDR 2008UALA00955Check Valve · faultyNR 1 ENGINE HAS THE L BLEED OFF EICAS MSG AND L-BLEED OFF LIGHT ON WITH BLEED SELECTED. REPLACED ISOLATION BYPASS CHECK VALVE. FOUND DIRECT SHORT AT PRSOV CONNECTOR. FOUND D22 CONNECTOR ON PRSOV BAD. REPLACED SAME. OPS CHECKED GOOD. REPLACED PRSOV. LEAKSDR 2008UALA00948Power Cable · defectiveAFT GALLEY XAISLE EEL INOP. REPLACED EEL POWER RIBBON, CHECKS GOOD.SDR 2008UALA00949Light · inoperativeEXT EMERGENCY LIGHT, AFT OF WING RT SIDE IS INOP. RELAMPED EMERGENCY LIGHT.SDR 2008UALA00920Display · failedRTFL DUE TO FAILURE OF THE MULTI-FUNCTION CONTROL DISPLAY UNIT.SDR 2008UALA00931Cap · missingEND CAPS MISSING FROM EEL LIGHTING AT SEATS 1B AND 1F. INSTALLED END CAPS
Back to Pratt & Whitney PW4060