SDR HALA0700445Wire · shortedETOPS SIGNIFICANT SYSTEM, STATUS MSG LEFT ENG OH LP2 DISPLAYED. T/S AND FOUND WIRES SHORTED TO THE UPPER FWD OVHT DETECTOR W314-458R-16 AND W314-457R-16. PERFORMED TYPLICAL TEMP REPAIR IAW BOEING STANDARD WIRING PRACTICE MANUAL 20-10-13. OPS CK IAW M/M 26-1SDR HALA0700443Housing · leakingETOPS SIGNIFICANT SYSTEM, NR 2 ENGINE HIGH OIL CONSUMPTION 8 PINTS ADDED. ACCOMPLISHED AMM TASK 79-00-00-206 STEP G. LEAKAGE DETECTION INSPECTION ON NR 2 ENGINE, FOUND LEAK AT NR 4 BEARING OIL STRAINER HOUSING. TORQUED AND SAFETY B-NUT, NO LEAKS NOTED ON ENSDR 2007UALA04174Girt Bar · brokenRIGHT OVERWING SLIDE PACK RETENTION BAR CLAMP IS BROKEN AND COMPARTMENT DOOR LATCHES (4 EA) CORRODED AT WBL 97.9. SLIDE REPLACED ON JC 61960 4016.SDR 2007UALA04175Girt Bar · brokenLEFT OVERWING SLIDE PACK RETENTION BAR CLAMPS BROKEN. SLIDE REPLACED.SDR 2007UALA04162Slide · inoperativeRIGHT EMERGENCY ESCAPE SLIDE TESTS INOP DURING SQUIB TEST. REPLACED OFF WING ESCAPE SYS. EMERGENCY BATTERY FOR RIGHT SIDE. (M962) ESCAPE SLIDE SQUIBS TEST NORMAL
SDR 2007UALA04163Lamp · inoperativeDURING EQUIP COOLING TEST, SMOKE LIGHT DOES NOT COME ON AND NO FWD EQUIPMENT SMOKE ADVISORY MESSAGE. RELAMPED SMOKE DETECTOR. OPS CK OK PER JC EQUIP COOLING TEST.SDR 2007UALA04152Starter · malfunctionedNR 2 ENGINE STARTER BLEW DURING START. DAMAGED REVERSER & FAN COWL. 11-01-07 REPLACING STARTER & STARTER VALVE. OP CHECK OF STARTER INDICATES BOTH ARE GOOD FOR SERVICE. SUSPECT BEARING DETERIORATION & RELEASE OF ROTOR CAUSING RESULTANT IMBALANCE AND DSDR 2007UALA04095Warning Light · illuminatedAPU GENERATOR "OFF" LIGHT ILLUMINATES AFTER RIGHT ENGINE STARTS.SDR 2007UALA04115Switch · faultyAPU AUTOSHUTDOWN 5 TIMES WITHIN 10 SECONDS AFTER STABILIZING AT 95PC RPM.
SDR 2007UALA04114Light · intermittentEMERGENCY LIGHTS ON RIGHT AISLE ROWS 15-18 COMING ON AND OFF. LEAVING EMERGENCY LIGHT SWITCH OFF FOR A TIME NO HELP. CHECKED ALL CONNECTIONS AND TESTED SYSTEM. ALL OPERATIONAL. NO DEFECTS FOUND. COULD NOT REPRODUCE PROBLEM.
SDR 2007UALA04128Valve · faultyFWD CABIN TEMP CONTROL FAILED TO CONTROL DESIRED TEMP. CREW COMMENTS: FWD AND MID CABINS EXTREMELY COLD. AFTER EXTENSIVE TROUBLE SHOOTING FOUND FAULTY FWD TRIM AIR VALVE AND LOW LIMIT CONTROL VALVE. REPLACED BOTH VALVES OP CHECKED GOOD. AC OK FOR SERVICE.SDR DL76L071316Starter · failedRIGHT ENGINE STARTER MOTOR FAILED DURING START CYCLE. STARTER MOTOR REPLACED. OIL SERVICE ACTIONED. DRY CYCLE OK. CHECK START ACTIONED ON PUSHBACK. MF PART NR 774860A4.SDR 2007UALA04059Pump · faultedFOUND FLICKERING FAULT AND L FUEL JET PUMP EICAS MSG.
SDR 2007UALA04035Light · looseFOUND EXIT PATH LIGHTING LOOSE AT 14AB LEFT SIDE. REPAIRED DAMAGED EEL LIGHT CIRCUIT.
SDR 2007UALA04072Unknown · unknownCREW COMMENTS: FUEL OVERBURN BY 6000 PLUS POUNDS.
SDR 2007UALA04074Unknown · unknownCREW COMMENTS: TEMPS VERY DIFFICULT IN COCKPIT, FIRST, BUS CLASSES.SDR HALA0700423Detection Sys · malfunctionedETOPS SIGNIFICANT SYSTEM, ON ETOPS CHECK FOUND EICAS MSG "R ENG OH LP 1". TROUBLESHOOT PER FIM 26-11-00 SWAPPED OVERHEAT CARD M689 AND M687 CONDITION SAME RE-INSTALLED OVERHEAT CARD TO ORIGINAL POSITION REPLACED RT ENGINE OVERHEAT DETECTORS PER AMM 26-11-02, SDR HALA0700420Seal · leakingETOPS SIGNIFICANT SYSTEM, EXCESSIVE OIL DRIPPING FROM NR 1 ENG. ACCOMPLISHED HI PWR RUN PER AMM 79-00-00-206-015-G00. FOUND ACCUMULATION OF OIL ON RT INBD COWLING (NR 1 ENG) GAUZE WRAP FROM OIL IN PORT OF FUEL SERVO HEATER FOUND WET ALONG WITH OIL ACCUMULATOSDR 2007UALA04032Battery Pack · inoperativeFOUND LEFT AFT FLOOR EEL DIM ONLY. REPLACED BATTERY PACK.
SDR 2007UALA04073Fire Loop · faultyEICAS MSG "ENG 1 FIRE LP2" DISPLAYED AT SHUTDOWN.SDR 2007UALA03994Feeder Cable · damagedC-ZONE FLOOR PROXIMITY LIGHTS INOP ON LEFT SIDE. 10-26-07 REMOVED AND REPLACED BATTERY PACK PER MM 33-51-07 , ALSO FOUND LIGHT BAR FEEDER BROKEN IN BETWEEN LH AFT LAVS, REPAIRED PER GN-MM 2-0-15-005 AND OPS CHECK GOOD.SDR 2007UALA03995Connector · looseEICAS MSG L GEN DRIVE DISPLAYED. GEN DRIVE LIGHT ILLUM. GEN DRIVE DISCONNECTED. FOUND TERMINAL CONNECTOR LOOSE, CLEANED, SECURED AND OPS CK NOW OK.
SDR 2007UALA03992Light · inoperativeEEL LIGHTS AT RIGHT OF MID GALLEY & AT ROW 5AB ARE INOP. 10-26-07 REPAIRED EEL POWER STRIP. OP CHECKS GOOD.SDR 2007UALA03993Light · inoperativeEEL LIGHT BARS AT THE RIGHT AFT LAV & IN FRONT OF THE VCC CABINET ARE INOPERATIVE. 10-26-07 REPAIRED EEL LIGHT BAR PER MM 33-51-10 AND OP CHECKS GOOD.SDR 2007UALA03996Light · inoperativeEEL STRIP LIGHTS OUT AT SEAT 1E. 10-26-07 REPAIRED EEL STRIP. OP CHECKS NORMALLY.SDR 2007UALA03955Flashlight · inoperativeMID CABIN, RIGHT OUTBOARD FLIGHT SEAT HAS INOP EMERGENCY FLASHLIGHT. 10-23-07 REPLACED EMERGENCY FLASHLIGHT BATTERY PACK IN RIGHT OUTBOARD FLIGHT ATTENDANT SEAT.SDR 2007UALA03884Feeder Cable · crackedNR 2 ENG IDG POWER FEED WIRES OUTER INSULATION IS CRACKED IN A FEW AREAS. REPAIRED NR 2 ENG IDG POWER FEEDER CABLES AT CRACKED AREAS IAW GNMM 2-0-15-1. INSP BY QC INSPECTOR AND RETURNED TO SERVICE.SDR 2007UALA03885Stringer · corrodedAFT PIT BS 1223 STR 36L IS CORRODED. REMOVED DAMAGE & FABRICATED REPAIR PART. INSTALLED STRINGER DOUBLER. INSPECTED & APPROVED FOR RETURN TO SERVICE.SDR 2007UALA03889Strip · looseEMERGENCY LIGHT STRIP BY 1E TRIM CAME OFF AND IS A TRIPPING HAZARD. SECURED LOOSE EEL LIGHT STRIP. OP CHECKED OK FOR SERVICE.SDR 2007UALA03934Drive Unit · failedRECEIVED "WXR FAIL ANT" ON EHSI. *S/D* REPLACED WEATHER RADAR ANTENNA DRIVE UNIT AS PER MM 34-43-05-401, TEST PASSED.SDR HALA0700402Isolation Valve · malfunctionedETOPS SIGNIFICANT SYSTEM, RT ISOLATION VALVE ILLUMINATED. REPLACED ISOLATING VALVE RIGHT SIDE INSTALLED PER AMM 36-11-04. REMOVED PER AMM 36-11-04. SECURITY CONDITION GOOD. OPS CK GOOD.SDR HALA0700401Proximity Sensor · malfunctionedETOPS SIGNIFICANT SYSTEM DURING A CK, FOUND RT REVERSER GREEN LIGHT NOT ON WITH NR 2 ENG IN REVERSE. FOUND OUTBOARD PROX SENSOR TARGET OUT OF RIG. ADJ TARGET. CKS OK, PER AMM 78-36-00.SDR HALA0700400Idg · leakingETOPS SIGNIFICANT SYSTEM, FOUND RT ENG IDG LEAKING OIL FROM FILL PORT FITTING. REPLACED IDG FILL PORT FITTING AND O-RING. RAN ENG. CKS OK.SDR 2007UALA03787Starter · failedUNABLE TO START RIGHT ENGINE. 10-19-07 REPLACED RIGHT ENGINE STARTER AND START VALVE. NOW RIGHT ENGINE STARTS NORMALLY. ALSO ALL INDICATIONS NORMAL .SDR HALA0700384Controller · malfunctionedATB: RT ENG BLEED OVHT UNABLE TO RESET PER QRH 2 RT ENG BLEED OVHT. BITE CK AIR SYS CTL MOD FOUND HPC FAULT. REPLACED PNEU TEMP SWITCH FOR RT BLEED. REPLACED HP CONTROLLER PER AMM 36-11-08 OP CK GOOD ON HIGH POWER RUN UP NO DEFECTS NOTED. REPLACED PCA CARSDR 2007UALA03760Lamp · inoperativeLEFT FWD GALLEY AISLE EEL LIGHT INOPERATIVE. 10-9-07 REPLACED LAMP, OP CHECKS OK.SDR 2007UALA03761Switch · faultyAFT ATTENDANT EMERGENCY LIGHT SWITCH LIGHT INOP. 10-9-07 EMERGENCY LIGHT SWITCH CONNECTED BACKWARDS. REWIRED SWITCH PER WDM 33-51-11, OP CHECK OKSDR 2007UALA03762Switch · faultyEMERGENCY EXIT LIGHTS ON W- SWITCH IN ARMED POSITION. 10-19-07 REPLACED FLT DECK AND AFT FLT ATTEND. SWITCHES REF WD 33-51-11 PG.1D OPS CKS GOOD.SDR HALA0700382Cooler · leakingETOPS SIGNIFICANT SYSTEM, ON WALKAROUND FOUND EXCESS OIL ON BOTTOM OF ENGINE NR 1 COWLS. MOTORED ENGINE. FOUND OIL SEEPING FROM FUEL OIL COOLER, OIL LINE. TIGHTEN FOUR BOLTS. RAN ENGINE AT IDLE FOR FIVE MINUTES. NO LEAKS NOTED. OK FOR SERVICE.SDR HALA0700380Electrical Box · malfunctionedETOPS SIGNIFICANT SYSTEM, AFTER ENGINE START RIGHT ENGINE EGT DECREASED FROM 435DEG TO 20DEG AND REMAINED AT 20 DEG WHEN THROTTLE ADVANCED. STANDBY INDICATIONS INDICATE SAME CONDX. REPLACED JUNCTION BOX PER AMM 77-21-02-004. REMOVED, INSTALLED AMM-77-21-004.SDR 2007UALA03731Battery · inoperativeLEFT SIDE EEL IS INOP FROM SEAT 27 TO AFT GALLEY. REPLACED BATTERY & EEL CHECKS GOOD.SDR 2007UALA03732Cable · kinkedRIGHT OVERWING SLIDE AFT DOOR OPENING ACTUATOR CABLE, UNTWISTED, PREVIOUSLY BIRD CAGED, KINKED. 10-9-07 REMOVED AND REPLACED RH OW ESC SLIDE AFT ACT CABLE PER MM 25-65-10.SDR 2007UALA03738Ballast · faultyFWD GALLEY OVERHEAD LIGHT EMITTED ODOR WHILE ON BUT WENT AWAY. LEFT IT OFF FOR REMAINDER OF FLIGHT. 10-9-07 REPLACED BALLAST M660, OP CHECKS OK.FOR SERVICE.SDR HALA0700378Engine · surgesETOPS SIGNIFICANT SYSTEM, ACARS EXCEEDANCE REPORT NR 1 ENGINE SURGE AT 35,000FT. ACCOMPLISHED HAL M105 FILE NR 582038 ITEMS NR 1 AND NR 2 WITH FOLLOW UP ACTION AS NOTED ON LOG PG 196039 ITEM 64. OK FOR SERVICE, NO DEFECTS NOTED.SDR HALA0700379Engine · surgesETOPS SIGNIFICANT SYSTEM, ACARS EXCEEDANCE REPORT NR 2 ENGINE SURGE AT 35,000 FT. ACCOMPLISHED HAL M105 FILE NR 582038 ITEM NR 3. NO DEFECTS NOTED. OK FOR SERVICE.SDR 2007UALA03697Floorbeam · crackedE/E COMPARTMENT, FLOORBEAM AT STA 246, APPROX RBL 19 HAS A CRACK IN VERTICAL STIFFENER. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED CRACKED STIFFENER.SDR 2007UALA03707Connector · disconnectedENTIRE FIRST CLASS EEL LIGHTS INOP LEFT SIDE AND X AISLE. 10-9-07 RECONNECTED AND SECURED FEEDER CONNECTOR.OPS CHECKED EEL LIGHTS, OK FOR SERVICE.SDR 2007UALA03708Lamp · inoperativeEEL LIGHTS INOP RIGHT SIDE ROWS 15 THRU 27. 10-9-07 REPLACED SHORTED EEL LAMP. ALL EEL OP CHECKS OK.SDR 2007UALA03689Lamp · inoperativeEMERGENCY CEILING LIGHT AT ROW 17AB INOP. 10-5-07 FOUND LAMP ASSY BROKEN. REPLACED LAMP ASSY. OP CHECK NORMAL.SDR 2007UALA03690Feeder Cable · failedEMERGENCY EEL LIGHTS FROM ROW 5AB-14AB & AT LEFT MID LAV ARE INOPERATIVE. 10-5-07 REPLACED POWER SUPPLY FEEDER CABLE. OP CHECKS GOOD.