As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS SIGNIFICANT SYSTEM, EXCESSIVE OIL DRIPPING FROM NR 1 ENG. ACCOMPLISHED HI PWR RUN PER AMM 79-00-00-206-015-G00. FOUND ACCUMULATION OF OIL ON RT INBD COWLING (NR 1 ENG) GAUZE WRAP FROM OIL IN PORT OF FUEL SERVO HEATER FOUND WET ALONG WITH OIL ACCUMULATOR AROUND FUEL PUMP AREA. REMOVED AND REPLACED FUEL SERVO HEATER OIL IN SEAL, ACCOMPLISHED HI PWR RUN LEAK CHECK GOOD. COWLING CLOSED AND SECURED.