Pratt & Whitney PW4060
Service difficulty reports · 7,182
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014021290369Stiffener · crackedFLOOR BEAM 246 FWD FACE STIFFENER CRACKED LBL 23 BS 246. CRACKED STIFFENER R & R IAW B767-300 SRM 51-40-02 & SRM B767 53-10-51 REPAIR 3 TIMCO NR 20003.SDR CALA2014021090327Unknown · leakingFLIGHT CANCELLED DUE TO HYD LEAK. REMOVE UNDERWING PANEL TO SEARCH FOR SOURCE.SDR CALA2014021190357Light · inoperativeRT WING NAV LIGHT BULB INOPERATIVE. PLACED RT GREEN NAV LIGHT ON MEL 3343B.SDR CALA2014021190358Floorbeam · corrodedMAIN CABIN FLOOR BEAM FOUND CORRODED AT STATION 303 & RBL 41. REMOVED DAMAGED SECTION & REPAIRED FLOOR BEAM T CORD IAW SRM 53-00-51 REPAIR 1, STATION 303, RBL 41 & WL 199.5.SDR CALA2014021190359Floorbeam · corrodedMAIN CABIN FLOOR STRUCTURE FOUND CORRODED BEYOND LIMITS BS 790, LBL 32. REMOVED DAMAGE & REPAIRED FLOOR BEAM LOCATED BETWEEN STATION 808 - 788, LBL 32 IAW SRM53-00-51 REPAIR 3 FIG 201 IAW TIMCO NR24938.SDR CALA2014021090348Light · intermittentEMERGENCY EXIT LIGHTS RANDOMLY FLICKERING OVER THREE WINDOW EXITS & SOME SEAT MOUNTED REDS. INTERIOR EMERGENCY LIGHTS VERIFIED IAW FIM TASK 33-51-00, ALL LIGHTS CHECKED OK. NO FLICKERING NOTED ON ALL EXIT WINDOWS LIGHTS DURING ALL GND TRANSIT WITH CONTROL SWSDR CALA2014021090349Floorbeam · corrodedC53-221 MAIN CABIN FLOOR BEAM STATION 287, BL 0, LBL 20 FOUND CORRODED. CORROSION FOUND OUT OF LIMITS AT STATION 287, BL 0, LBL 20. REPAIRED BEAM IAW SRM53-00-51REPAIR 4 IAW NR21219.SDR CALA2014021090350Floorbeam · corrodedFWD CARGO FLOOR BEAM T CAP FOUND CORRODED BEYOND LIMITS AT STATION 654 - 121, STRINGER 33L - 34L. ACCOMPLISHED REPAIR 4 OF SRM53-00-07 FIG 201 1-10.SDR CALA2014021090351Stiffener · corrodedFLOOR BEAM 246 FWD FACE STIFFENER CRACKED LBL 11 BS 246. CRACKED STIFFENER R & R IAW B767-300 SRM51-40-02 & B767-300 SRM 53-10-51 REPAIR 3.SDR CALA2014021090352Floor Support · corrodedFLOOR BOARD SUPPORT AT STATION 1524 - 1540, LBL 80 FOUND CORRODED BEYOND LIMITS SPLASH GUARD. REMOVED DAMAGE, FABRICATED EXTRUSION & INSTALLED IAW DRAWING 146T0051 & SRM 51-40-02.SDR CALA2014021090353Floor Support · corrodedMAIN CABIN FLOOR SUPPORT STATION 288 - 295, RBL 80 FOUND CORRODED, FOUND DAMAGE OUT OF LIMITS. R & R WITH NEW SPLASH GUARD IAW DRAWING 141T 8310 & SRM 51-40-02.SDR CALA2014021090356Warning System · activatedON SHORT FINAL CTR HYD DEM EICAS CAME ON WITH GEAR SELECTED DOWN & FLAPS 20 SELECTED.SDR CALA2014020690314Flap System · malfunctionedFLAP OVER SPEED ON GO AROUND. FLAPS RETRACTED FROM 30 TO 20 & THEN HAD FLAP SHUTDOWN MESSAGE. EG WAS AT 8 KNOTS OVER SPEED. PHASE ONE INSPECTION REQUIRED IAW AMM05-51-08. OPERATED FLAPS IN ALT MODE MESSAGE CLEARED, PERFORMED FLAPS OPERATIONS CHECKED IAW 27SDR CALA2014020690315Stiffener · crackedBS 246 FLOOR BEAM FWD FACE STIFFENER IS CRACKED AT RBL 11. INSPECTED THE MID CHORD & FLOOR BEAM WEB FOR CRACKS IN THIS LOCATION IAW ROUTINE TASK CARD 611003311, STEP 3, NOTE 1, NO CRACKS NOTED. REMOVED STIFFENER, FABRICATED REPLACEMENT STIFFENER 5 SUPPORT ISDR CALA2014020390284Battery Pack · dischargedEMERGENCY LIGHTS ON SEATS 19J - 21J DO NOT ILLUMINATE WITH EMERGENCY LIGHT SWITCH IN ON POSITION BY RT OVERWING EXITS. SIDEWALL LIGHTS ARE WORKING CORRECTLY. REPLACED EMERGENCY BATTERY PACKS AT SEAT SIDEWALL PANELS 18KJ & 20KJ IAW AMM 33-51-07, OPERATIONS CHSDR CALA2014020390285Light · inoperativeSEAT MOUNTED EMERGENCY LIGHT INOPERATIVE AT SEAT ROW 30JK. REPLACED LIGHT IAW MM 33-51-00, OPERATIONS OK.SDR CALA2014020390286Switch · dirtyEMERGENCY LIGHTS COME ON IN ENTIRE AIRCRAFT WITH EMERGENCY LIGHT SWITCH IN FLT DECK OFF POSITION. RESET & CLEANED AFT FLT ATTENDANT ON OFF SWITCH. OPERATIONS CHECKED GOOD IAW B767-300 AMM 33-51-00 ADJUSTMENT & TEST.SDR CALA2014012790242Skin · damagedFOUND CREASE ON FRAME 228 LAP SEAM STATION 222.4 TO 230.5 AT LAP SPLICE STRINGER 21L. THE DENT IS LOCATED IN THE RVSM CRITICAL AREA. REPAIRED IAW ECRA 5310-05971 REO 617052 REV B.SDR CALA2014012790243Floorbeam · gougedMAIN CABIN FLOOR BEAM AT BS 920 LBL 33 IS FOUND GOUGED. GOUGE FOUND OUT OF LIMITS. REMOVED DAMAGE & REPAIRED IAW SRM53-00-51 REPAIR 3 CAT A REPAIR.SDR CALA2014012790244Floorbeam · corrodedCORROSION FOUND ON MAIN CABIN FLOOR BEAM BS 850 LBL 55. CORROSION EXCEEDED LIMITS IAW SRM53-00-51. REMOVED & REPAIRED DAMAGED BEAM IAW SRM53-00- 51 RPR3.SDR CALA2014012790245Floorbeam · gougedMAIN CABIN FLOOR BEAM FOUND GOUGED AT BS 893 RBL 10. GOUGE EXCEEDED LIMITS IAW SRM53-00-51. REMOVED DAMAGE & REPAIRED IAW SRM 53-00-51 REPAIR 3.SDR CALA2014012290208Battery Pack · dischargedLT SIDE FIRST & BUSINESS CLASS SEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY LIGHT BATTERY PACK LOCATED AT STATION 988, WL 203 & LBL 92 IAW B767 AMM 33-51-07 & OPERATIONS CHECKED GOOD ON NON-ROUTINE 23120.SDR CALA2014012090194Support · corrodedMAIN CABIN RT UNDER FLOOR SEAT TRACK SUPPORT CORRODED AT BS 859, RBL 55. INSTALLED REPAIR IAW B767-300 SRM 53-00-51 REPAIR 3 PAGE 204.SDR CALA2014012090192Skin · dentedRT FUSELAGE SKIN DENTED AT STATION 654+66, STRINGER 29R. EVALUATED DENT & FOUND TO BE WITHIN LIMITS OF SRM 53-00-01. DENT WIDTH 2.65, DEPTH.054 & A OVER Y RATIO 49. DENT IS SMOOTH & CRACK FREE, OK TO ARCHIVE. ^18JAN GSO RPR RE-EVALUATED DENT AT S CHECK & FOSDR CALA2014012090193Skin · dentedEVALUATED FUSE SKIN BETWEEN BS 320 - 478 LT BETWEEN STRINGER 21L TO 23L. FOUND TWO DENTS AT BS 471 & STRINGER 23L OUT OF LIMITS IAW SRM 53-00-01. DENT CROSSES STRINGER 23L, NO OTHER DEFECTS NOTED. CUT OUT DAMAGED AREA OF SKIN AT BS 471 & STRINGER 23L. FABRSDR CALA2014011590156Light · inoperativeIAW TASK CARD 6-2006-A, FLOOR MOUNTED EMERGENCY EXIT LIGHT INOPERATIVE AT LT MID LAVATORY. REPLACED EMERGENCY EXIT LIGHT LT AT MID LAVATORY IAW MM 33-50-99, TEST IAW MM33-51-00 TESTED OK.SDR HALA2014011000003Warning Message · illuminatedDURING CRUISE, STATUS PAGE MESSAGE DISPLAYED FOR RT ENGINE EEC C1. FOLLOWED FIM 73-21/828. FOUND MESSAGE CH-B, CAT 1 FAULT ON RT PIMU FOLLOWED BY PIMU MESSAGE TABLE IAW FIM TASK 71-01-00/201 AND PERFORMED BITE/GROUND TEST OF PIMU THEN RESET, MESSAGE WENT OUTSDR CALA2014010890090Status Message · activatedSTATUS MESSAGE RT REV ISLN VLV CAME ON UPON LANDING.SDR CALA2014010790051Circuit Breaker · poppedCREW REPORTS ON PUSH BACK FOUND LT CTR FUEL PUMP CB IS POPPED.SDR CALA2014010790053Indication Sys · fluctuatesNR 2 ENG EICAS VIB INDICATION FLUCTUATES. VARIABLE 1.5 TO 3.6 AT DIFFERENT POWER SETTINGS.SDR CALA2014010290035Pressure Switch · dirtyRT ENG ANTI ICE VLV INTERMITTENTLY CAME ON AT ALL POWER SETTINGS. CLEANED RT ENG ANTI ICE PRESS SWITCH. ALL OPERATIONS CHECKED SATISFACTORY.SDR CALA2014010290036Fan · faultyAFT EXHAUST FAN 1 EICAS MESSAGE. REPLACED AFT EXHAUST FAN 1, OPERATIONS CHECKED NORMAL.SDR CALA2014010290037Fmu · faultyAFTER NR 1 ENG START EEC C1 STATUS MESSAGE APPEARED. REPLACED NR 1 ENG FMU. ACP TEST 3, LEAK & OPERATIONS CHECKED GOOD, NO MESSAGE.SDR CALA2014010290012Motor · faultyLT WIPER CONTINUES TO WIPE WHEN SWITCHED TO OFF. REPLACED WIPER MOTOR, CHECKED OKAY.SDR CALA2014010290028Windshield Wiper · damagedCAPTAIN`S SIDE WIPER BLADE FLEXES & APPEARS TO BE BROKEN. REPLACED CAPTAIN'S SIDE WIPER ARM & BLADE IAW AMM, CHECKED GOOD.SDR CALA2014010290034Oxygen Mask · defectiveCAPTAIN`S O2 MASK EMERGENCY TEST BUTTON STICKS. REPLACED MASK, GND CHECKED NORMAL.SDR CALA2014010290011Door · obstructed2L WILL NOT ARM. REMOVED DEBRIS FROM DOOR SILLSDR CALA2014010290030Relay · failedLT IDG VLV STATUS MESSAGE. TROUBLESHOT IAW FIM 24-20-00 PG 105, BLOCK 1 & 2 ARE BOTH, NO NEED TO START AT BLOCK 3, FIG 102, PG 106. ALSO PERFORMED BITE ON PBCU, NO IDG FAULTS, NR 1 ENG, IDG OIL SERVICED, SCAVENGE FILTER DPI IS GOOD. CHECKED WIRING & CONNECTOSDR CALA2014010290027Hose · leakingPOTABLE LEAKING NO PRESS. HOSE REPLACED LEAK CHECKED OK FOR SERVICE.SDR CALA2014010290038Smoke Goggles · contaminatedCAP SMOKE GOGGLES & COVER SOILED WITH LIQUID. REPLACED GOGGLES & COVER OK TO CONTINUE.SDR CALA2013123094016Cooling Fan · faultyFWD EQUIP COOLING EXHAUST FAN EICAS MESSAGE. ODOR SIMILAR TO ELECTRICAL ODOR WAS AFTER TAKE OFF & WHEN POWER RETARDED. ODOR WAS SHORT IN DURATION & DISSIPATED RAPIDLY WITH NO ACTION BY THE CREW OR FLIGHT ATTENDANTS. THE ODOR REMAINED GONE AFTER IT DISSIPATESDR CALA2013123094025Life Vest · missingLIFE VEST MISSING SEAT 35A. INSTALLED LIFE VEST AT SEAT 35A, OK TO CONTINUE.SDR CALA2013123094050B-Nut · leakingSUSPECT HYD LEAK AFT TAIL CONE AREA. FOUND SEVERAL B NUTS LEAKING AT THE ELEVATOR AP ACTUATORS. TIGHTENED, NO LEAKS NOTED.SDR CALA2013123194071Actuator · faultyFUEL CROSS FEED VLV LEFT ON & "FUEL CROSS FEED" EICAS MESSAGE DISPLAYED WHEN CROSS FEED SW OPEN OR CLOSED SELECTED. AFT FUEL CROSS FEED VLV IS UNUSUALLY SLOW TO OPERATE. REPLACED ACTUATOR IAW MM.SDR CALA2014010290031Valve · leakingBOOTS BY THE EQUIPMENT COOLING SOV WORN & LEAKING. INSTALLED NEW VLV IAW V 767-300 AMM 21-58-05 STEP11. REPLACED EQUIPMENT COOLING INDICATION CARD, NO HELP. REINSTALLED OLD CARD, REPLACED RELAYS K1206 & K1008, NO HELP. ACCOMPLISHED FIM TASK 21-58 -939 STEPSDR CALA2013122793971Control Valve · dirtyLT PACK OFF LIGHT DOES NOT ILLUMINATE WITH PACK SELECTED OFF. CLEANED LT PACK CONTROL VLV, CONNECTOR PACK OFF LIGHT ILLUMINATED. ACCOMPLISHED TEST IAW MM, ALL OPERATIONS & INDICATIONS NORMAL.SDR CALA2013122793973Ballast · defectiveVERY VERY LOUD SQUEAL IN OVERHEAD MID COACH CABIN. PLACED CEILING LIGHT AT ROW 30-31L ON MEL. BALLAST CONNECTOR D11218 DISCONNECTED & STOWED. BALLAST WAS THE CAUSE OF LOUD HUMMING NOISE, WILL REQUIRE BALLAST PCN 563-0055 & 05814-16 BALLAST.SDR CALA2014010290032Hinge · wornLT PACK RAM AIR INLET DOOR HINGE PIN IS MIGRATED OUT & RUBBING ON PLENUM. REMOVED LT PACK INLET DOOR. FWD & AFT DOOR HINGES WORN & AFT BLOCKS ARE WORN. ACCOMPLISHED INSTALLED INLET DOOR IAW AMM 21-53-01.SDR CALA2014010290033Latch · misinstalledFWD LATCH FOR LT OVERWING SLIDE PANEL DOES NOT ENGAGE. FOUND LATCH INSTALLED INCORRECTLY REINSTALLED LATCH IAW MM25-65-09 THRU STEP 3 D 1 D CONT OF AMIS ITEM 9872050. CONT IAW AMM 25-65-09 FROM 3 D 1 D THRU END OF 25-65-09, ALL CHECKED OK.SDR CALA2013122693954Light · inoperativeAFT CARGO FIRE WARNING LIGHT DOES NOT LIGHT WITH A FIRE TEST.
Back to Pratt & Whitney PW4060