Pratt & Whitney PW4060
Service difficulty reports · 7,182
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013122693955B-Nut · looseHYD FLUID STREAM IS VISIBLE COMING FROM APU ACCESS DOOR. FOUND B NUT LOOSE ON RT ELEVATOR PCA. TIGHTENED B NUT, OPERATED ELEVATOR NUMEROUS TIMES WITH NO LEAKS. CLEANED AREA. HYD QTY GOOD.SDR HALA2013122500181Fmu · failedRIGHT ENGINE N1 VARIES INLFIGHT DURING CRUISE. N1 CONTINUALLY OSCILLATES .5 PERCENT AT CONSTANT THROTTLE SETTING. RT ENGINE EPR CHANGES IN RELATION TO N1 CHANGES. REMOVED NR 2 ENGINE FMU, REF AMM 73-21-01. INSTALLED SERVICEABLE FMU ON NR 2 ENG IAW AMM 73-2SDR CALA2013122693926Ground Wire · damagedAT D41921 FWD PYLON NR 1 ENG HAS MULTIPLE GND WIRES BROKEN. REPAIRED WIRING SHIELD GNDS IAW SWP 20-10-15 & WDM 75-23-11, 78-36-11. SEE PTT 6182027, 6182028, 6182029, 6182040, 6182041, 6182042 & 6182043 FOR SPECIFIC DETAILS. IAW SMC053 FOR CANNON PLUG INSTALSDR CALA2013122693937Pressure Switch · inoperativeLT HYD DEMAND PUMP INOPERATIVE IN AUTO & ON MODE IAW IAHMM. REPLACED LT ENG DRIVEN PUMP LOW PRESS SW IAW AMM 29-11-17. OPERATIONS CHECKED GOOD NO LEAKS. ENG LOW PRESS SW WAS PREVENTING AUTO FUNCTION OF DEMAND PUMP.SDR CALA2013122793985Turbine Blades · damagedON ENG NR 1 ESN 717550 IAW EC6281, FOUND ONE EACH 2ND STAGE HPT BLADE DAMAGED. DAMAGE IS ON LE APPROXIMATELY 0.400 INCHES LONG BEGINNING 0.300 INCHES FROM THE END OF THE BLADE. THE DAMAGE IS ON BOTH THE CONVEX & CONCAVE SIDES & PARENT METAL IS MISSING WITH SDR CALA2013122693922Wire · damagedIAW SMC014 WIRE W356-149-20 SHIELD GND NEEDS REPAIR AT CONNECTOR D4192J. IAW WDM 78-36-11 REPAIRED SHIELD GND FOR WIRE W356-149-20 IAW SWP 20-10-15.SDR CALA2013122693923Wire · damagedIAW SMC014. WIRE W356-150-20 NEEDS SHIELD GND REPAIRED AT CONNECTOR D4192J, IAW WDM 78-36-11. REPAIRED SHIELD GND FOR WIRE W356-150-20 IAW SWP 20-10-15.SDR CALA2013122693924Heat Shield · damagedHEAT SHIELD, BLANKET ABOVE CNA DAMAGED. REPLACED HEAT SHIELDSDR CALA2013122693925Blanket · debondedINBD C DUCT NR 1 ENG HAS FIRE BLANKET DISBOND IN 2 AREAS, LOWER IS APPROXIMATELY 30 X 24 INCHES, UPPER IS APPROXIMATELY 10 X 18 INCHES. REPAIRED AREA IAW SRM 78- 31-01.SDR CALA2013122393891Fseu · malfunctionedSTATUS MESSAGE FLAP SLAT ELECTRICAL. STAB POSITION CARD M838 & FLAP SLAT ELECTRICAL UNIT AT FAULT. R & R STAB MODULE & FLAP SLAT MODULE IAW 27-51-01, 27-58-01. SYS OPERATIONS CHECKED GOOD. ALSO PERFORMED TEST 30 ALL SYS PASSED.SDR CALA2013122693915Duct · dentedINLET COWL ON NR 1 ENG INLET TIA TUBE HAS MULTIPLE DENTS & GOUGES FROM 3 O'CLOCK TO 6 O'CLOCK AFT FACING FWD. REVIEW OF CMM 36-10-06 PAGE 603 & 604 SHOWS FINDINGS OUT OF LIMITS. REPAIRED DUCT IAW CMM 36-10-06 REP 1-1.SDR CALA2013122693916Inlet · damagedNR 1 ENG INBD C DUCT COOLING AIR INLET NOT SEALANT MATING SURFACE. REPAIRED NR 1 ENG INBD C DUCT COOLING AIR INLET MATING SURFACE.SDR CALA2013122393879Skin · crackedNR 2 ENG PYLON FWD TORQUE BOX UPPER SPAR SKIN CRACKED AT THE HYD LINE EXIT, ACCESS PANEL 442BL. FOUND WEB CRACKED AT CASE DRAIN CUTOUT JUST AFT OF NAC STATION 172.14. REMOVED EXISTING REPAIR DOUBLER ON THE INBD SIDE & FABRICATED A NEW REPAIR DOUBLER & FILLERSDR CALA2013122393892Transceiver · faultyWX RADAR NOT PAINTING PRECIPITATION, UNABLE TO GET GND RETURNS. TROUBLE SHOT FOUND WX RADAR TRANSCEIVER NOT PAINTING RRD WX RADAR RT. OPERATIONS CHECKED OK AT THIS TIME.SDR CALA2013122393893Floorboard · damagedON ARRIVAL RAMP REPORTED DAMAGE TO FWD CARGO PIT FLOOR BOARD AT APPROXIMATELY STATION 650.SDR CALA2013122393894Actuator · failedRT PACK TEMP EICAS. COMPLETED CHECKLIST, OPERATING IN MANUAL, TEMP CONTROL DIFFICULT. FOUND RT PACK RAM AIR EXIT DOOR FAILED IN CLOSED MODE & ALSO FAULTED ON CONTROLLER BITE CHECK. REPLACED ACT WRT MM 21-53-04, ALSO CONTROLLER BITE CHECKED NORMAL.SDR CALA2013122693914Repair · damagedON ENG NR 1 RT CORE COWL UPPER TE CORNER, PREVIOUS REPAIR IS DAMAGED. REINSTALLED MISSING FILLER MATERIAL 071 2024 & REINSTALLED FASTENERS IAW SRM 51-40-02. IAW NON RII INSP OF REPAIR TO INBD TE CORE COWL NR 1 ENG. REPAIR IS COMPLETE IAW SRM 51-40-02.SDR CALA2013122093847Anti-Ice Valve · faultyWHEN SELECTING RT ENG ANTI ICE EICAS MESSAGE WITH VLV LIGHT ILLUMINATED IN SWITCH. REMOVED RT ENG ANTI ICE VLV & REPLACED NR 1 ENG ANTI ICE VLV IAW 30-21-03 UP TO PG 405 STEP 11. NEED TO CONT FROM STEP 11 TO END.SDR CALA2013122393858Longeron · crackedLT UNDERWING LONGERON FITTING INSPECTION. FOUND CRACKED. ACCOMPLISHED LT UNDERWING LONGERON INSPECTION. THE LONGERON WAS FOUND CRACKED, REQUIRING ISSUANCE OF OP NR 3 OF EA 5710-02220, REV A. OP NR 3 COMPLIED WITH IN CONJUNCTION WITH ECRA 5710-02331 FOR MINOR DSDR CALA2013122393903Anti-Ice Valve · faultyNR 1 ENG WHEN TAI IS SELECTED ON, VLV OPENS FOLLOWED BY INCREASE IN EGT. WHEN SELECTED OFF, EGT ROLLS BACK EICAS MESSAGE LT ENG ANTI ICE, WITH VLV LIGHT ILLUMINATED IN SWITCH. REPLACED NR 1 ENG ANTI ICE VLV IAW 30-21-03 UP TO PG 405 STEP 11. NEED TO CONT FRSDR CALA2013122693913Slide · faultyL1 DOOR SLIDE, RT SIDE RETAINING CABLES RELEASED, SLIDE REMOVED FROM DOOR. R & R L1 DOOR SLIDE IAW AMM.SDR CALA2013122093834Light · inoperativeLT & RT MID CABIN EMERGENCY LIGHT BARS ARE INOPERATIVE. R & R THE RT & LT EMERGENCY EXIT LIGHT BARS & OPERATIONS CHECKED GOOD IAW MM 33-51-10 ON NON-ROUTINE 49272.SDR CALA2013122093835Connector · unsecureAFT GALLEY EMERGENCY LIGHT BAR & AFT RT LAVATORY LIGHT BAR INOPERATIVE. SECURED CONNECTOR AT AFT GALLEY LIGHT BAR & REPLACED THE RT LAVATORY LIGHT BAR & OPERATIONS CHECKED IS GOOD IAW AMM 33-51-10 ON NON-ROUTINE 49262.SDR CALA2013122093846Shutoff Valve · faultyHAVE APU FUEL VLV EICAS & APU FAULT LIGHT. R & R APU FUEL SOV.SDR CALA2013122093848A/C Pack · inoperativeRT PACK INOPERATIVE LT EICAS RT PACK TEMP. OPERATES IN STANDBY.SDR CALA2013121993819Light · inoperativeSEATS 19AB - 23AB EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY LIGHT BULBS ON SEATS 19AB - 23AB IAW AMM 33-51-10 & OPERATIONS CHECKED GOOD.SDR CALA2013121993820Light · inoperativeSEATS 35JK TO 39JK EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY LIGHT BULBS IAW AMM & OPERATIONS CHECKED GOOD ON NON-ROUTINE 49263.SDR CALA2013121993821Light · inoperativeSEATS 28,29,35, 37 & 38AB EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY LIGHT BULBS IAW AMM 33-51-10 & OPERATIONS CHECKED GOOD.SDR CALA2013121893777Sdu · failedSATCOM DOES NOT PASS INSTALL TEST IAW WORK CARD 6-2013-2C. FAILED SDU CH 5 TX & RX FAULT. REPLACED SATCOM SDU IAW MM, CHECKED OK. SOFTWARE VERIFIED CORRECT IAW IPC 31-00-00-99 & DIS 39908.SDR CALA2013121993809Shutoff Valve · faultyFUEL IMBALANCE DUE TO REPEAT GRIPES OF FUEL IMBALANCE WITH RT TANK LESS THAN LT AFTER CTR TANK FUEL IS CONSUMED. OPEN UP ASSOCIATE FUEL TANKS & INSPECT INTERNAL PLUMBING FOR ANY LEAKS. IN ADDITION, REPLACE BOTH THE RT CTR MOTIVE FLOW VLV PCN 615-0008 & RT CTSDR CALA2013121693734Proximity Switch · faultyLE SLAT ASYM EICAS WHEN FLAPS LOWERED TO 1. BITE TEST ON PSEU BOX HAD FAULTED NR 5 SLAT INBD PROX SWITCH 286. REPLACED PROX SWITCH & ACP LE SLAT SENSOR OPERATION TEST. SYS TESTED NORMAL, EICAS MSG CLEARED.SDR CALA2013121693750Handle · defectiveCAPTAIN`S SIDE, RUDDER PEDAL ADJUST KNOB DOES NOT ENGAGE DETENTS, PEDALS CAN SLIP FWD. R & R CRANK HANDLE ON CRANK ASSEMBLY IAW AMM 27-21-06, OPERATIONS CHECKED NORMAL.SDR CALA2013121693751Paint · damagedFOA PAINT SCRAPED FROM SKIN SURFACE ADJACENT TO AFT CARGO DOOR FRAME, LOWER LT CORNER APPROXIMATELY STATION 1350 WL 28R. DIMENSIONS 6 INCH X 2 INCH X .002 INCH B.SDR CALA2013121693752Hydraulic Line · leakingNR 1 ENG WHILE PERFORMING ENGINE RUN FOUND A HEAVY HYD FLUID LEAKING OUT OF LARGE DRAIN MAST. FOUND FAR AFT HYD SUPPLY LINE IN J BOX LOOSE, TIGHTENED LINE. LEAKED CHECKED GOOD & OPERATIONS CHECKED GOOD.SDR CALA2013121693708Idg · faultyRT GEN OFF LIGHT ILLUMINATED ON DESCENT. RAN CHECKLIST RESET, DID NOT RESET. BPCU READOUT FOUND SHORTED PMG TRIP & GEN FIELD WIRING GCU. AFTER RESET PB BPCU TESTED OK. AFTER RT ENG RUN GEN OFF AGAIN. AIRCRAFT RELEASED IAW MEL.SDR HALA2013121100179Terminal · damagedDURING PDC CHECK, FOUND RT ENGINE FIRE LP2 MESSAGE ON EICAS PAGE. TROUBLESHOT IAW FIM 26-11 804. REPLACED TERMINAL LUGS FOR RT ENGINE FIRE DETECTOR TS683. OPS CHECKED OK.SDR CALA2013121693693Squib · faultyEMERGENCY ESCAPE SYSTEM FAILED TEST 2 AT P61 PANEL. R & R NR 7 SPOILER OVERRIDE ACTUATOR SQUIB IAW AMM 25-65-19 & PERFORMED SQUIB TEST IAW AMM 25-65-00 & TEST PASSED FOR TEST 1 & 2.SDR CALA2013121693694Battery Pack · dischargedLT FRONT CEILING EMERGENCY AISLE LIGHTS INOPERATIVE. R & R BATTERY PACK IAW AMM & OPERATIONS CHECKED GOOD.SDR CALA2013121693695Pin · brokenIAW EQ5099 TO R & R LT OVERWING SLIDE. IPC 25-65-08-01 LOCATING PIN ITEM 280 TWO EACH BROKEN. R & R OVERWING SLIDE LOCATING PINS AS REQUIRED.SDR CALA2013121893788Pump · leakingC2 HYD PUMP LEAKING. R & R C2 HYD ACMP PUMP, OPERATIONS & LEAK CHECKED GOOD.SDR CALA2013121793763Flap System · malfunctionedDIVERSION DUE TO LE SYMMETRY ISSUE COUPLED WITH MAIN FLAPS UNABLE TO ADVANCE BEYOND 20 DEGREES. IN THIS CONDITION AIRCRAFT IS UNABLE TO EXECUTE A AUTO LAND AS REQUIRED IAW FOM FOR CONDITIONS AT ETA.SDR CALA2013121393655Battery Pack · dischargedAFT CABIN LT & CTR LAVATORY EMERGENCY EXIT LIGHT STRIPS INOPERATIVE. R & R M1556 BATTERY PACK IAW AMM 33-51-10, OPERATIONS CHECKED GOOD.SDR CALA2013121393656Light · inoperativeAFT SEATS 27 - 39 SEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE. LIGHT ASSEMBLY ON SEAT 32JK & 36JK & REPLACED LIGHT BULBS AT SEAT 39JK & 38AB, OPERATIONS CHECKED GOOD IAW MM 33-51-10.SDR CALA2013120993543Relay · faultyRT CTR FUEL PUMP DOES NOT TEST PROPERLY. CLEANED RELAY K633, TESTED GOOD.SDR CALA2013120593495Clutch · faultyAPU WILL NOT START. BOTH ENG GEN OPERATES NORMALLY. HYD MOTOR GEN VERIFIED IAW 24-25-00-501. APU INTAKE DOOR IS CLOSED. GND PNEUMATIC SOURCE FOR ENG START USED AT GVA. STARTER ROTATING AT APU START BUT RPM NOT RISING ON EICAS. APU STARTER REMOVED & NO DAMSDR CALA2013120693516Fseu · faultyWITH FLAP HANDLE AT 5R FLAP IND 1 & LT FLAP IND 5. R & R FLAP SLAT ELECTRONIC UNIT IAW MM. PERFORMED BITE TEST IAW FIM 27-51-00 FIG 104, ALL SYSTEMS CHECKED GOOD. CYCLED FLAPS SEVERAL TIMES. NO DEFECTS NOTED AT THIS TIME, OPERATIONS CHECKED GOOD.SDR CALA2013120693517Fan · malfunctionedLT RECIRCULATING FAN LIGHT ON OVERHEAD & ON EICAS. PLACED LT RECIRCULATING FAN ON MEL IAW 2125A.SDR CALA2013120593475Brake · faultyNR 1 FWD BRAKE PIN IS 1-16". CURRENT PTC IS 14625 MUST BE REPLACED ON OR BEFORE PTC 14627. BRAKE PCN 160-9740. R & R NR 1 MLG BRAKE ASSEMBLY.SDR CALA2013121193610Wire · burnedWIRE W710-551-20 IS BURNT IN TWO UNDER LT SIDE CARGO BIN FLOOR PANEL NEXT TO LT WALL AT STATION 1220. SPLICED WIRE 0710-0551 STATION 1220 LT SIDEWALL.SDR CALA2013121193611Wire · burnedWIRE W710-562-20 IS BURNT IN TWO UNDER LT SIDE CARGO BIN FLOOR PANEL NEXT TO LT WALL AT STATION 1220. SPLICED WIRE W0710-0562 STATION 1220 LT SIDEWALL.
Back to Pratt & Whitney PW4060