Pratt & Whitney PW4090-3
Service difficulty reports · 2,638
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011093005308Diode · malfunctionedRAT INADVERTENTLY DEPLOYED, WHILE RESETTING CB'S IN ELMS P310 PSU-A&B PRIM (B4-C7) AND ELMS P310 PSU-A&B ALTN (J5-K5). RAT RETRACTED PER AMM. ITEM WORK WITH EG6198 FOR OPERATIONAL TEST. REPLACED TB405 POS 12 DIODE ACCOMPLISHED FIM TASK 24-09-TASK 819 AND RASDR UALA2011092805255Module · failedFMC LT STATUS MESSAGE. REPLACED FAILED M002 MODULE IN LT AIMS AND LOADED SOFTWARE.SDR UALA2011092805265Idg · failedRIGHT ELECTRIC GENERATOR DRIVE EICAS MESSAGE DISPLAYED. DISCONNECTED RIGHT IDG PER FLT MANUAL. AHM PROGRAM DETECTED MESSAGE 24-31552 RT IDG LOW OIL PRESSURE. REPLACE RIGHT ENGINE IDG.SDR UALA2011092805247Lamp · inoperativeFWD LAVATORY DARK UNTIL LOCKED. RELAMPED FWD LAVATORY.SDR UALA2011092805258Receptacle · brokenINTERPHONE AT L4 DOOR INOPERATIVE. REPLACED ZMU DOWN LOAD SOFTWARE. ALSO REPLACED HANDSET, NO HELP. RECEPTACLE PIN BROKEN.SDR UALA2011092605192Line · chafedHYDRAULIC SUPPLY LINE NR 2 ENGINE HAS RUBBER INSULATION WORN THROUGH EXPOSING BRAIDED METAL. INSTALLED AND LEAK CHECKED LINE. LEAK CHECKED GOOD ON ENGINE RUN. REPLACED NR 2 ENGINE HYD CLAMPS PER MM.SDR UALA2011092605207Start Valve · faultyAFTER NR 2 ENGINE START, CREW RECEIVED "ENG START VALVE 'R" MESSAGE DISPLAYED. START VALVE IS CLOSED, AS INDICATED BY "DUCT PSI" SUSPECT INDICATION PROBLEM. ENGINE OPERATION IS NORMAL. DEFERRED PER SAMC. REPLACED VALVE PER MM. ENGINE STARTING PER JRH. ALLSDR UALA2011092905284Structure · loosePILOT CREW REST AREA DOOR FRAME TRIM AT FWD BOTTOM IS STICKING OUT. SECURED TRIM WITH TAPE.SDR UALA2011092305143Controller · faultyAPU NO START ALONG WITH APU STATUS MESSAGE. REPLACED APUC AND INLET TEMP SENSOR PER MM.SDR UALA2011092605208Skin · tornRT MLG DOOR INBD EDGE SKIN TORN 14" LONG BY 4" DEEP. DAMAGE IS 2.5 FT FROM REAR EDGE OF DOOR. REMOVED RT MLG DOOR. DOOR REPAIRED & REINSTALLED PER MM. BONDING WIRES (3) DISCONNECTED ON RT MLG DOOR HINGE. .SDR UALA2011092305150Structure · damagedLEFT OUTBOARD TE FLAP DAMAGED JUST INBOARD OF NR 1 CANOE. REPAIRED REF SRM, REPAIR NR 12 AND SRM 70-0.SDR UALA2011092705209Fire Loop · shortedFIRE HANDLE WAS PULLED BY FLIGHT CREW DUE TO APU AUTO SHUT DOWN. BEFORE DEPARTURE APU AUTO SHUT DOWN, APU CONSIDERED INOPERATIVE. CREW PULLED HANDLE AND DISCHARGED FIRE EXTINGUISHER. REPLACED APU FIRE EXTINGUISHING BOTTLE AND SQUIB PER MM. BOTTLE PRESSURESDR UALA2011092305135Pump · weakFUEL PUMP CENTER R RIGHT CENTER (OVERRIDE) FUEL PUMP SWITCHED ON AND PUMP OUTPUT PRESSURE LOW. CENTER TANK ONLY HAD 2000 LBS OF FUEL. HAD TO INCREASE CENTER FUEL LOAD TO OVER 2400LBS PER MT 28-UA8. AFTER DOING SO EVERYTHING OKAY.SDR UALA2011092205122Wire · damagedCOPILOT FWD WINDSHIELD MISSING INSULATOR CAP FOR ELECTRIC HEATER. REPLACED POWER WIRE FOR F/O WINDSHIELD. RE-INSTALLED CAP. ACCOMPLISHED RIGHT WINDSHIELD TEST PER MM, CHECKED OKAY.SDR UALA2011092005061Windshield · delaminatedCAPT WINDSHIELD HAS 2 INCH BY 4 INCH DELAMINATION. REPLACED CAPTAINS NR 1 WINDOW PER MM. PERFORMED WINDOW ANTI-ICE TEST PER MM. OK FOR SERVICE.SDR UALA2011092105112Fairing · damagedKEEL BEAM FAIRING 149BL HAS DAMAGE.SDR UALA2011092205121Coupler · faultyHF RADIO TRANSMISSION PROBLEM. MAT FAULTS RT HF, ACCOMPLISHED FIM 23-11 TASK 809. REPLACED RT TRANSCEIVER PER MM, NO HELP. REPLACED ORIGINAL, REPLACED HF COUPLER PER MM, OPS CHECKED GOOD.SDR UALA2011092005086Relay · faultyELEC STANDBY SYS MESSAGE. REPLAC'E K24006 MAIN BATTERY RELAY, NO HELP. REPLACED RELAYS K24020 & K24019, NO HELP. ABOVE SHOULD READ RELAY K24006 NOT K24020. PRIOR TO 2ND TEST HOP, WITH AC POWERED UP FROM BATTERY ONLY, AFTER APU PWR SUPPLIED, GOT 'ELEC STANDSDR UALA2011091905038Idg · faultyL ENG OFF & DRIVE LIGHT STAYED ON AFTER ENG START, NO STATUS NO EICAS. CYCLED GEN CTL SWITCH NO CHANGE. GEN DRV LIGHT ILLUMINATED BRIEFLY THEN WENT OUT WHEN OPPOSITE ENGINE WAS SHUT DOWN. NO STATUS MSGS OR EICAS ADVISORY MSGS FOR GEN DRIVE. CREW DID NOT DISDR UALA2011091905040Idg · faultyLEFT ENGINE GENERATOR DID NOT COME ON LINE AT ENGINE START. CYCLED GEN CTL SWITCH NO CHANGE. GEN DRV LIGHT ILLUMINATED BRIEFLY THEN WENT OUT WHEN OPPOSITE ENGINE WAS SHUT DOWN. NO STATUS MSGS OR EICAS ADVISORY MSGS FOR GEN DRIVE. CREW DID NOT DISCONNECT GESDR UALA2011091905020Relay · faultyCABIN SMOKE INDICATION, RTFL. PER CREW LOWER CREW REST AREA SMOKE DET MSG ON CABIN AREA PANELS WITH ASSOCIATED WARNING HORN SOUNDING. CREW REST DOOR CYCLED, ALT PA SYSTEM SELECTED, BOTTLE DISCHARGE SWITCH SELECTED TO ARM WITH NO HELP. CB'S FOR CREW REST SOV-SDR UALA2011091605018Control Valve · faultyPRIMARY FLAPS FAIL EICAS THIRD FLIGHT IN A ROW SYSTEM GOES ALTN FLAP. SAMC TEXT: PLZ ACP MT27-001R1. T/S PER 777MT 27-011 R1. FOUND FLAP PCV CONNECTOR DV27004B PIN 5-12 LOOP IS OPEN. REPLACED FLAP PCV, LEAK CHECK OK & FLAP OPS CHECK NORMAL PER MM.SDR UALA2011091605016Idg · faultyELEC GEN DRIVE R RIGHT IDG FAULT (LOW INTERNAL OIL PRESSURE) - ADVISORY CREW COMMENTS: DISCONNECTED GEN DRIVER. PROG TEXT: - ITEM ROLLED FORWARD. EICAS MSG ELEC GEN SYS R. FOLLOWED MEL PROC. CHECKED RT IDG AND NO DAMAGE AND OIL LEAK FOUND. IDG OIL SHOUSDR UALA2011091605017Fseu · faultySTATUS MSG FLAP PRIMARY MSG 27-20372. REPLACED FSEU 2 PER MM, OKAY.SDR UALA2011091504983Light · looseSEAT 2E FWD EEL LIGHT LOOSE. SECURED SEAT 2E FWD EEL LIGHT. EEL LIGHT, OPS CHECK GOOD.SDR UALA2011091404976Computer · faultyEICAS STATUS MESSAGE "NO LAND 3" AND "PFC CHANNEL" ARE DISPLAYED. REF SMC 5 FOR INCOMPATIBLE PFC HARDWARE & SOFTWARE. SEE PTT SEQ 6912018 FOR R AND CENTER PFC RPL.SDR UALA2011091204934Housing · defectiveCREW REPORTS BLEED LOSS WING L FAULT WITH BLEED LEAK L CAUTION MSG. REPLACED LT PACK DIFFUSER HOUSING. FOUND BLOWN SEAL. ACCOMPLISHED NR 1 ENG RUN-UP. BLEED NORMAL. LEAK CK GOOD, NO MSGS.SDR UALA2011091204946Computer · faultyPFC LANE FAULT 27-14012. BOEING AHM PROGRAM HAS DETECTED REPEAT FAULT MSG 27-14012 PFC R LANE 1 FAULT. REPLACE THE PFC-R (483-9216) PER MM, CONFIRM PFC SOFTWARE IS CORRECT FOR ALL 3 PFC'S. ACP PFC LANE RESET TEST TWICE TO UNLATCH REMAINING FAULTS. IF PFC-R SDR UALA2011091204938Slat · damagedSLAT NR 4 WAS HIT BY BIRD. ACCOMPLISH INSPECTION OR RECHECK. SLAT DAMAGE MEASURING 10 INCHES LONG X 3 INCHES WIDTH X 3-32 DEEP. VISUAL INSPECTION WAS PERFORMED AND NO OTHER DAMAGES LIKE CRACKS, LOOSE RIVETS OR DAMAGE TO THE SLAT STRUCTURE WAS NOTICED. SLAT SDR UALA2011091204941Sdu · faultySATCOM VOICE VOICE PORTION OF SATCOM FAILS. ADVISORY MSG06- NOT ACTIVE CRUISE INTERMITTENT; SATELLITE DATA UNIT (LEFT) HAS NO OUTPUT ON DATA TO CMU BUS (429). DB- LEFT AIMS MSG-2360121 ACTIVE ER INTER MSG-2360121 ACTIVE ER HARD MSG-2360131 ACTIVE ER HARD MSGSDR UALA2011091204945Module · faultyFLIGHT CONTROL CAUTION MESSAGE ON UPPER EICAS, CLEARS WITH PFC SELF TEST, REAPPEARS WITH THIRD HYS SYSTEM. TS INSTALLED NEW HYDIM CL AND CR REF MM, NO HELP. REPLACED HYDIM CR MODULE, OPS CK GOOD.SDR UALA2011091204920O2 Generator · dischargedLLAR BED 'BAY 4'. O2 GENERATOR FOUND DISCHARGED. REPLACED O2 GENERATOR ON PSU REF MM. UPON ASSY FOUND DOOR LATCH WILL NOT SECURE. TAPED DOOR CLOSED PER MEL INSTRUCTIONS. IPC REF 35-11-18-011 ITEM NR 1. P/N 418W1080-2241A, NS UAL. MEL ALSO REQUIRES DEFERL SDR UALA2011091204921Pbe · unserviceableLLAR PBE FOUND SOFT. REPLACED PBE.SDR UALA2011091204925O2 Generator · dischargedLLAR BED 'BAY 4'. O2 GENERATOR FOUND DISCHARGED. REPLACED O2 GENERATOR ON PSU. UPON ASSY FOUND DOOR LATCH WILL NOT SECURE. TAPED DOOR CLOSED PER MEL INSTRUCTIONS. IPC REF NR 1. P/N 418W1080-2241A, N/S UAL. MEL ALSO REQUIRES DEFERAL OF ASSOCIATED SEAT PER SDR UALA2011091204939Sdu · malfunctionedCHRONIC SATCOM HI GAIN STATUS, HAS AT LEAST 2 PREVIOUS HITS AND STATUS MSG HAPPENED ABOUT 20 TIMES. COMPLIED WITH REQUIREMENTS IN MEL 2315B. REPLACED SATCOM SDU, OPS CHECK GOOD.SDR UALA2011091204940Diplexer · faultyDURING TEST FOR SATCOM SDU REPLACE MAT TEST FAILS LO NOISE AMP-DIPLEXER FOR THE LGA. REPLACED REF AMM. SATCOM TESTS GOOD.SDR UALA2011091204914Unknown · odorSMOKE ODOR NOTICED BY DOOR 2L. ACCOMPLISHED FIM TASK.SDR UALA2011091204916Skin · damagedRT FUSELAGE STATIC PORT HAS DENT IN HEATED PORTION. LIGHTNING DAMAGE IN THE EXTRA CRITICAL SKIN AREA AT THE RT STATIC PORT ON THE RT SIDE STA 764. ACCOMPLISHED HFEC INSP OF INSIDE OF DRILLED HOLE AND OF EXT SKIN AROUND HOLE. NO CRACKS FOUND. LIGHTLY BLEND 3ESDR UALA2011090904870Brake · damagedBRAKE ASSY FULL OF METAL FROM WHEEL BEARING DAMAGE. BRAKE ASSY MAY ALSO HAVE DAMAGE. NEED TO REPLACE NR 2 FWD BRAKE. REMOVED OLD BRAKE ASSY NR 2 FWD REF MM. NEW BRAKE ASSY IN AREA. INSTALLED SERVICEABLE BRAKE ASSY.SDR UALA2011090904884Shutoff Valve · faultyTWO RECYLES AND 1 RESET REQUIRED FOR RIGHT PACK OPERATION ON GROUND. FOUND TRIM AIR PRSOV TORQUE MOTOR NOT IN COMMANDED POSITION MESSAGE. REPLACED TRIM AIR PRSOV FOR RIGHT PACK PER AMM. RAN RIGHT PACK OPS CHECKS GOOD AT THIS TIME.SDR UALA2011091204937Fan · failedLAV-GALLEY FAN L STATUS MESSAGE ON IN-FLIGHT. DEFERRED PER MEL 2126C. LEFT LAV-GALLEY FAN FAILED MAT TEST. FOUND LAV-GALLEY FAN C-B TRIPPED ON THE P110 PANEL. RESET C-B, RAN TEST ON MAT AGAIN, C-B TRIPPED. MAT SHOWS MAINT MSG 21-11241. REPLACED FAN PER MMSDR UALA2011090904872Casting · brokenFOUND DOOR 4R GIRT BAR AFT ATTACH CASTING BROKEN. SAFTIED GIRT BAR AND CASTING TO DOOR FRAME TO CLOSE DOOR. REPLACED AFT GIRT BAR CASTING ON DOOR 4R.SDR UALA2011090704848Precooler · crackedNR 2 ENGINE PRECOOLER CRACKED AT BOTTOM. COMPLETE INSTALLATION OF NR 2 PRECOOLER. INSTALLATION THRU ITEM G. NEED TO COMPLETE INSTALLATION FROM 3H TO END - ACCOMPLISHED.SDR UALA2011090704856Gearbox · leakingNR 1 ENG ECM MONITORING SHOWING INCREASED OIL CONSUMPTION. REFER TO FIM 71-05 TASK 830 AND PERFORM ENGINE CHECK NR 7-OIL LEAKS PER FIM 71-08 TASK 819 PAYING PARTICULAR ATTENTION TO RECENT DISTURBED COMPONENTS: OIL TANK & LINES (REMOVED FOR AIR SHIP), ANGLE GSDR UALA2011090704829Pbe · faultyPBE 1L SOFT. REPLACED PBE.SDR UALA2011090704830Pbe · faultyPBE 2L IS SOFT. REPLACED PBE.SDR UALA2011090704831Pbe · faultyPBE SR IS SOFT. REPLACED PBE.SDR UALA2011090704832Pbe · faultyPBE 4L IS SOFT. REPLACED PBE.SDR UALA2011090704857Unknown · odorCREW COMMENTS: BURNING SMELL IN CABIN WITH RECIRCULATION FANS ON. FANS LEFT-OFF. SAMC TEXT: TURNED GASPER FANS ON 3HRS AGO. NO FURTHER COMPLAINTS OF NOXIOUS SMELL, HOWEVER THE SMELL HAS CONTINUED THROUGHOUT THE FLIGHT IN THE VICINITY OF 1A, SMELLS LIKE BUSDR UALA2011090504808Window · damagedWINDOW (FLIGHT DECK) - SHOWS SIGNS OF DAMAGE. CREW COMMENTS: WHEN SUN ON WINDOW VISION OBSCURED DUE TO PITTING AND SCRATCHES. SAMC TEXT: F/O SIDE WINDOW, 2. REPLACED FLT DECK NR 2 OPERABLE WINDOW ASSY PER MM.
Back to Pratt & Whitney PW4090-3