Pratt & Whitney PW4090-3
Service difficulty reports · 2,638
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013102292268Pump · faultyC1 ADP WILL NOT PRODUCE MORE THAN 1500 PSI WHEN OPERATED WITH APU BLEED AIR. PUMP SLOWLY WILL RISE TO 3000PSI. PRESSURE ALSO CYCLES.SDR CALA2013102292269Engine · surges2706-2 ENG 222023 CMC SENT MAINT MSG 71-60432 'RIGHT ENG HAS SURGED' IN CRUISE BUT NO FLIGHT CREW REPORTSDR CALA2013102292270Insulation · deterioratedUPON OPENING RT PACK BAY FOUND INSULATION HEAT SHIELD DETERIORATING AFT OF HEAT EXCHANGER, CLAMP FOUND LOOSE IN AREA. REPLACED INSULATION BLANKET IAW IPC.SDR CALA2013102492338Unknown · odorCREW NOTICED A SWEET ODOR FROM AROUND ROWS 8 & 9AB & DOOR 2L AREA. CREW SHUT OFF POWER TO ROW 8 & 9, SHUT DOWN VIDEO SYSTEM POWER AT DOOR 2L & REMOVED FLUORESCENT BULBS FROM 2L LAVATORY. CHECKED GALLEY AREA FOR SOURCE, SMELL DISSIPATED BUT UNABLE TO LOCATE SDR CALA2013102192224Light · inoperativeEXIT LIGHT ON RT AT CENTER DIVIDER BETWEEN BC & YC INOPERATIVE. RELAMPED, OPERATIONS CHECKED, EXIT LIGHT GOOD.SDR CALA2013102292253Thermocouple · out of toleranceNR 1 ENG TCA THERMOCOUPLE OUT OF RANGE CH. B. REPLACED NR 1 ENG TCA PROBE IAW AMM, OPERATIONS CHECKED OKAY.SDR CALA2013102292255Lens · missingEMERGENCY EXIT LIGHT LENSES MISSING ON BOTH AISLES OF UB-TO-ECONOMY PLUS CTR CLASS DIVIDER. REPLACED LENSES.SDR CALA2013102192195Brake · wornNR 1 MIDDLE BRAKE FOUND WORN BEYOND LIMITS. REPLACED MLG BRAKE ASSEMBLY IAW MM.SDR CALA2013102192237Circuit Card · faultedLEFT ENGINE FIRE LOOP 1 & 2 FAULTED. REPLACED BOTH LT & RT FODC FIRE DETECTOR CARDS IN P84 & P85 A10 CARDS IAW MM 26-11-03 & OPS CHECKED GOOD.SDR CALA2013101792133Pin · damagedDURING LT HORIZONTAL STAB PIVOT PIN REPLACEMENT IAW COA 210 181, THE NEW PIVOT PIN WAS FOUND TO HAVE DAMAGED THREADS. REWORKED DAMAGED THREADS & MAG PARTICLE INSPECTED IAW ECRA 5510-02334. INSTALLED PIVOT PIN IAW COA 210181.SDR CALA2013101792134Skin · scratchedEXTERNAL FUSELAGE SKIN HAS TWO DEEP SCRATCHES AT BS 437 ABOVE STRINGER 47L. AFTER BLENDING, THE SKIN THICKNESS WAS OUT OF LIMITS IAW SRM 53-00-01. REMOVED DAMAGE, MANUFACTURED DOUBLER & FILLERS & INSTALLED REPAIR IAW SRM 53-00-01 REPAIR 6. ALL FASTENER HOLESDR CALA2013101892172Valve · failedPACK MODE RT PACK AIR CYCLE MACHINE HAS FAILED, OR RT ECONOMY COOLING VLV FAILED OPEN, OR BOTH RT CONDENSER INLET TEMP SENSORS FAILED. RT PACK IS OPERATING IN A NON NORMAL MODE HEAT EXCHANGER ONLY COOLING MODE. REPLACED RT PACK LOW LIMIT VLV IAW AMM. DUE TOSDR CALA2013101892175Indicator · faultyIAW EQ4836 TANK UNIT CTR LT NR 8 M28154 IS OPEN OR SHORTED. FAULT OCCURRED INTERMITTENTLY LEGS 8, 15, 19 & 21. CTR TANK INDICATION INOPERATIVE PARTS 483-2010 5041KTU01TANK.SDR CALA2013101892174Probe · intermittentLT MAIN TANK UNIT 12L M28085 SIGNAL IS OUT OF RANGE. IT HAS BEEN HIT INTERMITTENTLY DURING LEGS 2, 9, 12 & 16. REPLACED LT MAIN TANK UNIT 12L PROBE.SDR CALA2013101792145Shutoff Valve · malfunctionedBLEED PRSOV LEFT MESSAGE DUE TO CHRONIC BLEED PRSOV LEFT MESSAGES, PLEASE PERFORM A PNEUMATIC SYSTEM HEALTH CHECK IAW SERVICE TIP 36-UA1 FOR PRSOV MUSCLE LINE FROM PRSOV TO PRSOV CONT. R & R PRSOV IAW AMM 36-11-09. ALSO, REPLACED PRSOV CONTROLLER IAW 36-11-1SDR CALA2013101792146Actuator · faultyEICAS MESSAGE LT SPAR VLV. REPLACED ACTUATOR, MESSAGE IS GONE. OPERATIONS CHECKED NORMAL.SDR CALA2013101892171Outflow Valve · malfunctionedCABIN ALTITUDE AUTO LOSS OF INPUT FROM, OR FAILURE OF BOTH ASCPC'S, OR LOSS OF INPUT OR FAILURE OF BOTH OFV'S, OR A COMBINATION OF THE ABOVE THAT RESULTS IN LOSS OF COMPLETE AUTOMATIC CONTROL, OR MANUAL MODE SELECTED FOR BOTH OFV'S. CAUTION IAW PTT SEQ 56920SDR CALA2013101592088Pressure Switch · damagedNR 1 ENG FUEL PUMP FILTER DIFFERENTIAL PRESS SWITCH THREADS STRIPPED. REPLACED NR 1 ENG FUEL PUMP DIFFERENTIAL PRESS SWITCH.SDR CALA2013101692096Bearing · seizedRT RAM INLET DOOR FWD TORQUE TUBE IS FROZEN. DISCONNECTED INLET DOOR FWD ARM ASSEMBLY & ACTUATOR FROM THE TORQUE TUBE. REPLACED OTBD END CAP BEARING ASSEMBLY ON TORQUE TUBE, CLEANED & LUBED INBD BEARING. OPERATIONS CHECKED OKAY. RECONNECTED ALL COMPONENTS.SDR CALA2013101592064Trim Switch · faultyPITCH TRIM ELECTRIC INOPERATIVE ON BOTH CAPTAINS & FIRST OFFICERS YOLKS IN NOSE DOWN DIRECTION. ALTERNATE PITCH TRIM OPERATED NORMALLY & INDICATED NORMALLY ON STAB TRIM INDICATOR. R & R CAPTAINS PITCH TRIM SWITCH IAW AMM, OPERATIONS GOOD.SDR CALA2013101191963Valve · faultyECON COOL VLV LT PACK ECONOMY COOLING VLV NOT IN COMMANDED POSITION. PERFORMED AIR ON TEST IAW FIM 21-52-811. VLV RESETS AT BEGINNING OF TEST BUT FAILS DURING ECON VLV OPERATION. IAW NEW VALVE 646-0029. REPLACED VLV IAW AMM 21-52-31 NEED TO ACP LEAK & OPESDR CALA2013101191964Pump · leakingEVIDENCE OF HYD LEAK FLUID IN THE RT WW. FLUID IN THE RT WW. FOUND C2 ACMP CENTER ELEC HYD PUMP LEAKING AT PUMP HOUSING, PUMP NEEDED 611-9025 - MR29183. NO LEAK NOTED WHEN C1 ACMP IS IN USE. C2 ACMP ELEC PUMP INOPERATIVE. NO LEAK NOTED WHEN REMAINING HYD SDR CALA2013101191978Reveal · crackedWINDOW PANE AT 39K CRACKED. REPLACED WINDOW REVEAL.SDR CALA2013101191984Shutoff Valve · failedBLEED OFF ENG LT ENG BLEED VLV CLOSED FOR SYSTEM FAULT OR SWITCH OFF & THE ENG IS NOT SHUTDOWN. ADVISORY MSG01- LATCHED DESCENT MODE DEPENDENT. HIGH PRESSURE SHUTOFF VLV LT FAILED CLOSED. DB- AIR SUPPLY & CABIN PRESSURE CONTROLLER LT MSG02- LATCHED DESCENTSDR CALA2013101191962Inlet · damagedNR 2 ENG INLET BETWEEN 8 & 9 O'CLOCK POSITION HAS SMALL DAMAGED TO COMPOSITE AREA.SDR CALA2013101191977Inlet · damagedNR 2 ENG INLET BETWEEN 8 & 9 O'CLOCK POSITION, HAS SMALL DAMAGED TO COMPOSITE AREA.SDR CALA2013101191983Igniter · failedENG IGNITOR R1 RT ENG FAILED TO IGNITE USING IGNITOR 1.SDR CALA2013101592063Inlet · damagedNR 2 ENG INLET BETWEEN 8 & 9 O'CLOCK POSITION. HAS SMALL DAMAGED TO COMPOSITE AREA.SDR CALA2013100991920Oxygen Mask · leakingCREW O2 NOW 980 SUSPECT POSSIBLE LEAK. FOUND FIRST OBSERVERS SEAT CREW MASK LEAKING. REPLACED MASK. ALL ACCESSIBLE FITTINGS IN NOSE TUNNEL FROM BOTTLE TO FLOOR LINE & OTHER CREW MASKS WERE LEAK CHECKED, NO ADDITIONAL LEAKS FOUND.SDR CALA2013100891861Unknown · malfunctionedAPU WON'T START BY ELECTRIC STARTER, OK FOR BY PNEUMATIC. APU USEABLE IAW MEL.SDR CALA2013100891866Display · inoperativeDISPLAY UNIT BLANK, BLINKS ON & OFF. CAPT ND DISPLAY INOPERATIVE. SWAP CAPT ND MR31612-562 TO LOWER EICAS DISPLAY MR31612-555. AFTER SWAP CAPT ND CHECKED OK. LOWER EICAS DISPLAY INOPERATIVE IAW MEL. REMOVED LOWER DU MR31612-562 & INSTALLED LOWER DU MR31612-SDR CALA2013100991919Lru · malfunctionedACE TEST FAILED SHOW RT ACE INTERNAL FAULT. MESSAGE 27-13003, 27-13002, 27-13001 & 27-13000 DISPLAYED AFTER ACE MONITOR TEST PASS INDICATED ON MX PAGE. THIS CONDITION OK IAW MM. ACCOMPLISHED ACE LRU REPLACED TEST TO UNLATCH FAULTS. ALL LRU REPLACEMENT TESTSDR CALA2013100891832Idg · faultyLT GEN DRIVE LT PREVIOUS GRIPE REPLACED LT ENG IDG DUE TO METAL FOUND IN FILTER. RAN ENG, OPERATIONS CHECKED NORMAL.SDR CALA2013100891862Shutoff Valve · faultyTRIM AIR PRSOV RT PACK. DUE TO REPEATED HITS FOR RT PACK TRIM AIR PRSOV MSG 21-24202. PLEASE REPLACE THE RT TRIM AIR PRSOV V21622 646-9008 MR21670 AMM 21-62-01. INSTALLED NEW PRSOV IAW AMM 21-62-01, GROUND TEST PASSED OPERATIONS NORMAL.SDR CALA2013100891865Eec · unknownENG EEC C1 LT ENGINE CONTROL IS IN A TIME LIMITED DISPATCH CONDITION.SDR CALA2013100791763Pin · missingRT AIR COND PACK BAY, FOUND RT AMC BOTTOM SIDE MISSING AN INDEX ROLL PIN, HOT AIR BLOWING IN COMPARTMENT. INOPED SECOND STAGE TURBINE BYPASS VALVE IN OPEN POSITION, REMOVED & CAPPED CONNECTOR. SWAPPED LT & RT LOW LIMIT VALVE. SECOND STAGE TURBINE BYPASS VALSDR CALA2013100791788Warning System · activatedEICAS MESSAGE HYD PUMP DEM C1. ACCOMPLISHED MEL, REPLACEMENT OF ACP MODULATING SHUT-OFF VALVE. NO HELPSDR CALA2013100791791Pressure Sensor · faultyAPU AUTO SHUTDOWN AFTER ENGINE START. REPLACED APU CHECK VALUE DIFFERENTIAL PRESSURE SENSOR & SURGE CONTROL VALVE IAW AMM, OPERATIONS CHECKED NORMAL. RAN BOTH ENGINES, APU OPERATIONS NORMAL.SDR CALA2013100891853Air Filter · cloggedRECIRCULATING MESSAGE ON EICAS ALL CABIN RECIRCULATING FILTERS MUST BE REPLACED. ONE IN MID GALLEY CEILING FOUND COMPLETELY PLUGGED WITH INSULATION MATERIAL, REPLACED UPPER RECIRCULATING AIR FILTERS. LOWER RECIRCULATING FILTERS STILL NEED TO BE REPLACED. RSDR CALA2013100991918Air Filter · dirtyRECIRCULATING MESSAGE ON EICAS. REPLACED UPPER RECIRCULATING AIR FILTERS.SDR CALA2013100791789Window · crackedLT FWD WINDOW SHATTERED. AFTER FINISHED COA209881, REPLACED WITH NEW WINDOW SHIELD IAW AMM 56-11-01. MAT TEST PASSED, NO DEFECT NOTED.SDR CALA2013100791824Pump · intermittentHYD PRESS PRI C1 LOW CENTER SYSTEM HYD PRIMARY PUMP NR 1 PRESS OR PUMP SWITCHED OFF. PUMP INTERMITTENT, OPERATIONS OK AT PRESENT.SDR CALA2013100891833Cover · looseDOOR ARMING COVER FOR DOOR 2R LOOSE. REPLACED DOOR 2R ARMING COVER & SPRING ASSEMBLY IAW IPC 52-11-25.SDR CALA2013100891852Idg · faultyELEC GEN OFF LT EICAS. RESET ONCE OK, THEN TRIPPED OFF AGAIN. REPLACED LT GENERATOR CONTROL UNIT IAW AMM 24-22-02. RAN ENGINE, NO HELP. GEN CAME ON LINE, FREQUENCY OUT OF RANGE WHEN UNDER LOAD. R & R IDG NR 1 ENG, OPERATIONS CHECKED NORMAL. NO LEAKS NOTESDR CALA2013100891863Battery · faultyFUEL SHUTOFF VALVE BATTERY STATUS MSG. DEF IAW MEL. ACCOMPLISHED FIM 28-22 TASK 842, REPLACED ENG FUEL SPAR VALVE BATTERY IAW MM. OPERATIONS TESTED IAW MM, OPERATIONS NORMAL.SDR CALA2013100891864Sensor · faultyRT PACK STATUS MESSAGE PRESENT. FAULTING RT PRIMARY HEAT EXCHANGER INLET TEMPERATURE SENSOR IAW MM 21-51-04. NO MESSAGE NO FAULTS.SDR CALA2013100791762Hydraulic Line · frayedRT TRUCK TILT ACTUATOR LINE FRAYED. REPAIRED COVERING IAW GNMM 1-0-13-008.SDR CALA2013100791823Door · damagedAFT CARGO DOOR AFT LOWER CORNER DAMAGED WHILE CLOSING DOOR AT DEPARTURE TIME. REPAIR IAW SRM 52-30-01 REPAIR 17 NEEDS HFEC AT DAMAGED AREA.SDR CALA2013100891851Strip · damagedNR 2 GAP STRIP ON LT ENGINE PYLON CRACKED. BLENDED DAMAGE ON NR 2 GAP STRIP. PERFORMED HFEC AFTER BLEND OUT, NO CRACKS NOTED. AREA OF DAMAGE IS 12" BY .062" WITH TOTAL AREA OF EXPOSURE OF .744 SQ INS. IAW WITH ALLOWABLE DAMAGES 1 TABLE B FIG 103 PG 114 GAPSDR CALA2013100391686Pump · faultyIAW DF186 C1 AIR DRIVEN PUMP ASSEMBLY REQUIRES REPLACEMENT. REPLACED C1 AIR DRIVEN PUMP IAW MM. ALL NORMAL OPERATIONS GOOD.
Back to Pratt & Whitney PW4090-3