Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 2A6D20260814Frame · corrodedCORROSION ON THE COLLECTIVE SPLIT FRAME ON FWD AND AFT SIDE OF OPENING.Aug 14, 2026 · N741AC · Urocop EC130T2 · Fuselage Main, FrameSDR 2A6D20260813002Rib · chafedCHAFE DAMAGE ON BL 1263 RIB ON RH SIDE OF HORIZONTAL STABILIZER.Aug 13, 2026 · N741AC · Urocop EC130T2 · Horizontal Stabilizer, Spar/RibSDR 2A6D20260813001Crossbeam · chafedGOUGE/CHAFE DAMAGE TO THE AFT LANDING GEAR ATTACHMENT FWD CROSSBEAM AND SUPPORT ANGLE.Aug 13, 2026 · N741AC · Urocop EC130T2 · Fuselage Main, StructureSDR 2A6D20260728001Support Angle · crackedCRACK FOUND ON SUPPORT ANGLE OF UPPER LEFT FUSELAGE TO TAILBOOM ATTACHMENTJun 16, 2026 · N350MV · Snias AS350B3 · Fuselage Miscellaneous StructureSDR 2A6D20260305001Fuel Line · bentWHILE HOVER TAXIING THE AIRCRAFT DURING CHECK FLIGHTS, THE PILOT REPORTED A FUEL P LIGHT AND TURNED THE AIRCRAFT AROUND TO RETURN TO THE RAMP. DURING THE FLIGHT BACK, THE PILOT WAS ALERTED TO AN AMBER GOV LIGHT AND NOTICED THAT THE AIRCRAFT WAS LOSING POWER. TMar 3, 2026 · N11KQ · Urocop EC130T2 · Aircraft Fuel Distribution SystemSDR 2A6D20251125001Crossbeam · chafedVARIOUS DAMAGES AT THE AFT LANDING GEAR LOCATION, THE FIRST DAMAGE (#1) IS AT THE AFT LANDING GEAR CROSS BEAM SHIM (P/N: 350A214344.20) IN THE FORM OF CHAFING. THE CHAFE DAMAGE IS POSSIBLE DUE TO WEAR IN THE SHIM (P/N: 350A410064.20) BETWEEN THE AFT LANDING GENov 25, 2025 · N92OU · Urocop EC130B4 · Fuselage Main, StructureSDR 2A6D20251106001Bulkhead · chafedCHAFING DAMAGE ON THE LT LONGITUDINAL BULKHEAD (X-FRAME) ON THE UPPER INBD FACE MEASURING APPROXIMATELY 0.017" IN DEPTH, 0.10" IN WIDTH, AND 0.210" IN LENGTH. THE DAMAGE WAS REPAIRED WITH A DOUBLER IAW AIR METHODS ENGINEERING AUTHORIZATION 33-5300-EA-5308.Nov 6, 2025 · N629AM · Snias AS350B3 · Fuselage Main, BulkheadSDR 2A6D20251105001Beam · chafedDAMAGE TO THE RH Y398.5 BEAM (P/N: 350A211351.22) AND STOP DOUBLER (P/N: 350A211363.25) IN THE FORM OF A CHAFE. THE CHAFE DAMAGE IS NEAR THE FWD UPPER SIDE OF THE CUTOUT AND WAS MEASURED TO BE APPROXIMATELY 0.4" IN LENGTH AND 0.040" IN DEPTH.Nov 5, 2025 · N629AM · Snias AS350B3 · Fuselage Main, StructureSDR 2A6D20251006001Keelbeam · damagedA MIS-DRILLED HOLE WAS FOUND ON THE FORWARD LH KEEL BEAM (PN: 350A21-1350-20), AFT LH KEEL BEAM (PN: 350A21-1056- 20) AND FWD KNOT ASSEMBLY LH SPLICE (PN: 350A21-1071-20) LOCATED AT Y400 X 1296. TOOL MARK DAMAGE WAS ALSO DISCOVERED ON THE FWD KNOT ASSEMBLY LOct 6, 2025 · N814SM · Snias AS350B3 · Fuselage Main, KeelSDR 2A6D20250818001Mount Flange · gougedDAMAGE TO THE LANDING GEAR LH OTBD AFT BEARING IN THE FORM OF GOUGE. THE GOUGE DAMAGE IS AT LOWER FLANGE OF THE BEARING AND WAS MEASURED TO BE APPROXIMATELY 0.3895” X 0.1105” X DEPTH MORE THAN HALF THE THICKNESS OF THE BEARING.Aug 18, 2025 · N109LN · Snias AS350B3 · Fuselage, Landing Gear Attach FittingsSDR 2A6D20250602002Floor Support · chafedCHAFE DAMAGE WAS DISCOVERED ON THE R/H CABIN FLOOR EDGE P/N: 350A21-1359-21Jun 2, 2025 · N267AM · Snias AS350B3 · Fuselage Miscellaneous StructureSDR 2A6D20250602001Doubler · chafedCHAFING DAMAGE WAS DISCOVERED ON T/R SERVO GUIDE DOUBLER P/N: 355A23-2000-20Jun 2, 2025 · N267AM · Snias AS350B3 · Fuselage Main, Plate/SkinSDR 2A6D20250502001Xmsn Deck · chafedGOUGING- TOOL DAMAGE WAS DISCOVERED ON THE LH SIDE OF THE TRANSMISSION DECK. THE DEPTH IS APPROXIMATELY 0.026". THE MAXIMUM APPROXIMATE LENGTH IS .6 AND WIDTH IS 0.85".Jun 2, 2025 · N11UQ · Urocop EC130T2 · Fuselage Main, StructureSDR 2A6D20250130001Beam · damagedFASTENER HOLE DAMAGE (ELONGATION) WAS DISCOVERED ON THE LH MAINTENANCE FOOTSTEP BEAM (P/N 350A21124520) IN THE FUSELAGE REAR STRUCTURE.Jan 30, 2025 · N354CF · Snias AS350B3 · Fuselage Main, StructureSDR 2A6D20241209001Crossbeam · chafedTHE FIRST DAMAGE IS ON THE AFT LANDING GEAR CROSS BEAM (P/N: 350A214311.20). THE AFT CROSS BEAM IS DAMAGED DUE TO MISSING SHIM BETWEEN THE AFT LANDING GEAR LOWER ARM AND LOWER HALF BEARING WHICH CREATED LATERAL MOVEMENT OF LANDING GEAR CROSS TUBE AND CAUSED CHDec 9, 2024 · N317AM · Urocop EC130B4 · Fuselage Main, StructureSDR 2A6D20240828006Structure · gougedGOUGE AT THE OUTBOARD FLANGE RIVNUT LOCATION IN THE FORM OF SHEAR OUT. THE GOUGE WAS MEASURED TO BE APPROXIMATELY 0.1” X 0.1285”X 0.060”.Aug 28, 2024 · N108LN · Snias AS350B3 · Fuselage Structure (General)SDR 2A6D20240828003Bulkhead Web · chafedDAMAGE TO THE 15° BULKHEAD LH WEB (PN: 350A21-1032.86) IN THE FORM OF SEVERAL CHAFES. THE CHAFES WERE REPORTED TO BE 0.20” X 0.10” AND 0.004” DEEP, AS WELL AS 0.20” X 0.30” AND 0.010” DEEPAug 28, 2024 · N108LN · Snias AS350B3 · Fuselage Structure (General)SDR 2A6D20240828002Structure · gougedDAMAGE TO THE LH UPPER CARGO EDGING (P/N: 350A211041.22) IN THE FORM OF A GOUGE CAUSED WHILE INSTALLING BLIND FASTENER. THE GOUGE DAMAGE NEAR AFT SIDE OF THE LH EDGING AND WAS MEASURED TO BE APPROXIMATELY 0.40” X 0.15” X 0.02”.Aug 28, 2024 · N108LN · Snias AS350B3 · Fuselage Miscellaneous StructureSDR 2A6D20240828001Floor Panel · corrodedTHERE IS CORROSION DAMAGE TO THE CABIN FLOOR EDGING (PN: 350A21-1359-20/21).Aug 28, 2024 · N108LN · Snias AS350B3 · Fuselage Floor PanelSDR 2A6D20240614001Attach Angle · crackedDAMAGE TO THE BAGGAGE COMPARTMENT LH FWD LOWER ANGLE (P/N: 350A210053.28) IN THE FORM OF GOUGE/CRACK. THE GOUGE/CRACK DAMAGE MEASURED TO BE APPROXIMATELY 0.13” IN DIAMETER.Jun 14, 2024 · N11FQ · Urocop EC130T2 · Fuselage Main, Attach FittingsSDR 2A6D20240528001Frame · corrodedDAMAGE TO THE AFT UPPER FRAME (P/N: 350A21-1242.35) IN THE FORM OF CORROSION. THE CORROSION DAMAGE IS ON THE UPPER FLANGE OF FRAME AT LH AND RH BOTTOM SIDE NEAR THE AFT LOWER FRAME. THE LH SIDE CORROSION DAMAGE MEASURED TO BE APPROXIMATELY 0.71: X 2.05” AND THMay 28, 2024 · N11FQ · Urocop EC130T2 · Fuselage Main, FrameSDR 2A6D20240509003Floorbeam · corrodedDAMAGE IS ON THE LH CABIN FLOOR EDGE FITTING (P/N: 350A214753.20) IN THE FORM OF CORROSION AND CRACKS. THE LH FITTING PLATE IS EXCESSIVELY CORRODED AND THE CRACK DAMAGES AT TWO FASTENER HOLES TO EOP WHICH RESULTS IN REPLACEMENT OF LH FITTING.May 9, 2024 · N11FQ · Urocop EC130T2 · Fuselage Main, Floor BeamSDR 2A6D20240509002Bonding Plate · corrodedDAMAGE IS ON THE TAIL BOOM VHF ANTENNA BASE PLATE (P/N: 350A65-1707.00) IN THE FORM OF CORROSION. THE BASE PLATE IS EXCESSIVELY CORRODED AND DEPTH OF THE DAMAGE IS ALL THE WAY THROUGH THICKNESS WHICH RESULTS IN REPLACEMENT OF ANTENNA BASE PLATE.May 9, 2024 · N11FQ · Urocop EC130T2 · Fuselage Main, StructureSDR 2A6D20240509001Bulkhead · corrodedTHE UPPER 7° BULKHEAD DOUBLER (PN: 350A21-0849.20) IS CORRODED AT THE LOCATION OF A PASS-THRU HOLE. THE DAMAGE AREA WAS REPORTED TO BE 0.80” X 0.50” AND 0.030” DEEP AT THE DEEPEST POINTMay 9, 2024 · N11FQ · Urocop EC130T2 · Fuselage Main, BulkheadSDR 2A6D20240508003Crosstube · corrodedTHE AFT LANDING GEAR CROSSTUBE FITTING (PN: 350A21-0960.20) IS CORRODED IN MULTIPLE AREAS ON THE LOWER SURFACE. THE DEEPEST DAMAGE AREA WAS REPORTED TO BE 0.022” DEEP AND THE LARGEST AREA IS APPROXIMATELY 0.40” WIDE WITH VARIOUS LENGTHSMay 8, 2024 · N11FQ · Urocop EC130T2 · Fuselage Main, StructureSDR 2A6D20240508002Crossbeam · corrodedTHE RH X2244 CROSSBEAM (PN: 350A21-0861.20) IS CORRODED IN AN AREA ON THE LOWER OUTBOARD CORNER OF THE CROSSBEAM. THE DAMAGE WAS REPORTED TO BE 0.572” X 0.179” AND 0.028” DEEPMay 8, 2024 · N11FQ · Urocop EC130T2 · Fuselage Structure (General)SDR 2A6D20240508001Crossbeam · corrodedTHE RH X1790 CROSSBEAM (PN: 350A21-0572.20) IS CORRODED IN AN AREA WHERE IT CONTACTS THE RH Y400 BEAM (PN: 350A21-0587.20)May 8, 2024 · N11FQ · Urocop EC130T2 · Fuselage Main, StructureSDR 2A6D2024043002Beam · damagedDAMAGE TO THE LH BEAM UNDER THE ENGINE DECK (P/N: 355A21-2110.25) IN THE FORM OF AN ELONGATED HOLE IN THE LOWER FLANGE NEAR THE AFT END OF THE PART. THE ORIGINAL HOLE IS 1/8” DIAMETER, AND THE ELONGATED HOLE WAS MEASURED TO BE APPROXIMATELY 0.4” X 0.2”.Apr 25, 2024 · N350AM · Snias AS350B3 · Fuselage Main, Floor BeamSDR 2A6D20240425009Skin Panel · corrodedCORROSION DAMAGE ON THE FWD UPPER SKIN MEASURED TO BE APPROXIMATELY 0.80” X 0.60” X 0.003”Apr 25, 2024 · N11FQ · Urocop EC130T2 · Fuselage Main, Plate/SkinSDR 2A6D20240425008Stiffener · corrodedDAMAGE TO THE TAIL BOOM LH FWD STIFFENER MEASURED TO BE APPROXIMATELY 0.85” X 0.85” X 0.0125” IN THE FORM OF CORROSION.Apr 25, 2024 · N11FQ · Urocop EC130T2 · Rotorcraft Tail BoomSDR 2A6D20240425007Attach Angle · corrodedREAR LANDING GEAR ATTACHMENT LOWER ANGLE HAS DAMAGE IN THE FORM OF CORROSION. THE DAMAGE NEAR THE ANGLE OVERLAPS WITH MACHINED FRAME AND AFT LOWER BELLY FAIRING. THE DAMAGE IS ON THE VERTICAL FACE OF THE ANGLE AT PREVIOUS REPAIR LOCATION AND IS MEASURED TO BE Apr 25, 2024 · N11FQ · Urocop EC130T2 · Fuselage, Landing Gear Attach FittingsSDR 2A6D20240425006Cradle · corrodedRH AFT FUEL CRADLE REINFORCEMENTS HAS DAMAGE IN THE FORM OF CORROSION. THE RH AFT CORROSION DAMAGE MEASURED TO BE APPROXIMATELY 2.1” X 0.80” X 0.009”.Apr 25, 2024 · N11FQ · Urocop EC130T2 · Fuel StorageSDR 2A6D20240425005Cradle · corrodedTHE LH FWD FUEL CRADLE REINFORCEMENTS HAD DAMAGE IN THE FORM OF CORROSION. THE LH FWD CORROSION DAMAGE MEASURED TO BE APPROXIMATELY 1.0” X 0.80” X 0.008”.Apr 25, 2024 · N11FQ · Urocop EC130T2 · Fuel StorageSDR 2A6D20240425004Skin Panel · corrodedDAMAGE IS ON THE AFT FUSELAGE RH SIDE SKIN PANEL (P/N: 350A210046-21 IN THE FORM OF CORROSION. THE RH SIDE SKIN DAMAGE IS NEAR TOP EDGE WHERE ENGINE DECK OVERLAPS AND MEASURED TO BE APPROXIMATELY 0.15” X 0.20” X 0.011”.Apr 25, 2024 · N11FQ · Urocop EC130T2 · Fuselage Main, Plate/SkinSDR 2A6D20240425003Skin Panel · corrodedFIRST DAMAGE IS ON THE AFT FUSELAGE LH SIDE SKIN PANEL IN THE FORM OF CORROSION. THE LH SIDE SKIN DAMAGE IS NEAR TOP EDGE WHERE ENGINE DECK OVERLAPS AND MEASURED TO BE APPROXIMATELY 0.15” X 0.35” X 0.009”.Apr 25, 2024 · N11FQ · Urocop EC130T2 · Fuselage Main, Plate/SkinSDR 2A6D20240425002Brace · corrodedDAMAGE TO THE LH VERTICAL ANGLE (PN: 350A62-1148.21) ON THE AFT SECTION FWD LOWER FRAME IN THE FORM OF CORROSION. THE CORRODED AREA IS LOCATED AT THE BOTTOM END OF THE ANGLE, AND WAS MEASURED TO BE APPROXIMATELY 0.875” X 0.875” IN SIZE THROUGH THE FULL THICKNEApr 25, 2024 · N11FQ · Urocop EC130T2 · Fuselage Miscellaneous StructureSDR 2A6D20240425001Web · corrodedDAMAGE TO THE LOWER CENTER WEB IN THE FORM OF CORROSION. THE CORROSION DAMAGE IS TOWARDS THE AFT SIDE OF THE WEB NEAR LIGHTENING HOLES AND MEASURED TO BE THROUGH THICKNESS IN DEPTH.Apr 25, 2024 · N11FQ · Urocop EC130T2 · Fuselage Miscellaneous StructureSDR 2A6D20240402001Xmsn Deck · chafedCHAFING DAMAGE WAS DISCOVERED ON THE L/H SIDE TRANSMISSION DECK.Apr 2, 2024 · N629AM · Snias AS350B3 · Fuselage Main, StructureSDR 2A6D20240329001Xmsn Deck · chafedCHAFING DAMAGE WAS DISCOVERED ON THE TRANSMISSION DECK. THE DAMAGE MEASURES APPROXIMATELY 0.3” LONG, 0.1 WIDE WITH A MAXIMUM DEPTH OF 0.010".Mar 29, 2024 · N350AM · Snias AS350B3 · Fuselage Main, StructureSDR 2A6D20240321002Floor Support · corrodedCORROSION DAMAGE DISCOVERED TO THE R/H CABIN FLOOR EDGING P/N: 350A21-1359-21.Mar 21, 2024 · N4497Y · Snias AS350B3 · Fuselage Miscellaneous StructureSDR 2A6D20240321001Floor Support · corrodedCORROSION DAMAGE DISCOVERED TO THE L/H CABIN FLOOR EDGING P/N: 350A21-1359-20.Mar 21, 2024 · N4497Y · Snias AS350B3 · Fuselage Miscellaneous StructureSDR 2A6D20240320001Support Angle · corrodedEXFOLIATION CORROSION LOCATED ON FWD. L/H SIDE STIFFENER OF MASTER ELECTRICAL BOX.Mar 20, 2024 · N11FQ · Urocop EC130T2 · Fuselage Miscellaneous StructureSDR 2A6D20240229001Bulkhead · crackedA CRACK WAS DISCOVERED ON THE AFT BULKHEAD CENTER STRUCTURE. THE CRACK MEASURES APPROXIMATELY 1.0 INCH LONGFeb 29, 2024 · N344AM · Urocop EC130B4 · Fuselage Main, BulkheadSDR 2A6D20240201002Web · corrodedDAMAGE TO THE LOWER CENTER WEB (P/N: 350A21-4300.20) IN THE FORM OF CORROSION. THE CORROSION DAMAGE IS TOWARDS THE AFT SIDE OF THE WEB NEAR LIGHTENING HOLES AND MEASURED TO BE THROUGH THICKNESS IN DEPTH.Feb 1, 2024 · N11FQ · Urocop EC130B4 · Fuselage Miscellaneous StructureSDR 2A6D20240201001Angle · corrodedDAMAGE TO THE LH VERTICAL ANGLE (PN: 350A62-1148.21) ON THE AFT SECTION FWD LOWER FRAME IN THE FORM OF CORROSION. THE CORRODED AREA IS LOCATED AT THE BOTTOM END OF THE ANGLE, AND WAS MEASURED TO BE APPROXIMATELY 0.875” X 0.875” IN SIZE THROUGH THE FULL THICKNEFeb 1, 2024 · N11FQ · Urocop EC130B4 · Fuselage Miscellaneous StructureSDR 2A6D20231102001Floor Support · corrodedCORROSION WAS FOUND ON THE CABIN FLOOR EDGING ON THE LH AND RH SIDE (P/N: 350A21-1359-20/21)Nov 2, 2023 · N574AM · Snias AS350B3 · Fuselage Miscellaneous StructureSDR 2A6D20230825001Bulkhead · chafedDAMAGE WAS DISCOVERED ON THE LH SIDE OF THE 15 DEGREE BULKHEAD ON THE AFT FACE. THE CHAFE CORRESPONDS TO AN ANGLE CLIP OF THE SHEET METAL LOX ENCLOSURE RUBBING ON THE AFT WALL. THE CHAFE MEASURES APPROX. 0.029” DEEP, 0.1” LONG AND 0.2” WIDE.Aug 25, 2023 · N790K · Urocop EC130T2 · Fuselage Main, BulkheadSDR 2A6D20230824003Xmsn Deck · chafedCHAFING DAMAGE WAS DISCOVERED ON THE LH SIDE OF THE TRANSMISSION DECK. THE FIRST CHAFE AREA MEASURES APPROXIMATELY: 0.014" DEEP, 3/8" LONG AND 1/4" WIDE. THE SECOND CHAFE AREA MEASURES APPROXIMATELY 0.007” DEEP, 3/8” WIDE AND 2.5” LONG.Aug 24, 2023 · N544AM · Snias AS350B3 · Fuselage Main, StructureSDR 2A6D20230807002Bulkhead · chafedDAMAGE TO THE AFT BULKHEAD PANEL (P/N: 350A21-1570.20) IN THE FORM OF MULTIPLE CHAFED AREAS IN THE PART, MOST OF WHICH ARE FOUND ON THE TOPS OF THE STIFFENING FEATURES. THE LARGEST CHAFE WAS MEASURED TO BE APPROXIMATELY 1.40” X 0.70” AND 0.0075” DEEP.Aug 7, 2023 · N223SH · Urocop EC130T2 · Fuselage Main, BulkheadSDR 2A6D20230807001Flange · crackedDAMAGE TO THE LH SIDE OF THE 7 DEG BULKHEAD FLANGE (P/N: 350A21-0980.22) IN THE FORM OF A CRACK AND A DENT AT THE FASTENER LOCATION. THE CRACK THROUGH THE FLANGE MEASURED TO BE APPROXIMATELY 0.65” IN LENGTH AND THE DENT DAMAGE MEASURED TO BE APPROXIMATELY 0.5”Aug 7, 2023 · N223SH · Urocop EC130T2 · Fuselage Miscellaneous Structure
Back to Air Methods LLC