- Certificate number
- XC4R643M
- Designator
- XC4R
- Name on the FAA list
- FUTURE AVIATION INC
- Address
- 14111 JETPORT LOOP
FORT MYERS, FL 33913 - Phone
- (239) 225-0101
- gtuttle@heico.com
- Accountable manager
- TUTTLE, GREGG A
(239) 225-0101 - Liaison
- JEREMIAS, MATTHEW
(239) 225-0101
mjeremias@heico.com - Bilateral agreements
- EASA, United Kingdom
- On the FAA list
- On the list of October 26, 2026; listed since October 26, 2026 or earlier (OpenAirDocs’ first copy)
- Difficulty reports filed
- 106
From the FAA’s Find a Facility dashboard. The FAA writes names in capitals; the mixed case here is OpenAirDocs’ . The dashboard has no certificate dates, and nothing on it shows whether a certificate is in good standing: confirm with the station or its FAA office.
On this page
Ratings
What the FAA certificated the station to work on (14 CFR 145.59 and 145.61). A limited rating covers only the makes and models in the station’s operations specifications, which the FAA doesn’t publish.
| Rating | Class | What it covers |
|---|---|---|
| Radio | Limited | Only the makes and models in its operations specifications |
| Instrument | Limited | Only the makes and models in its operations specifications |
| Accessory | Class 1 | Mechanical accessories |
| Class 2 | Electrical accessories | |
| Class 3 | Electronic accessories | |
| Limited | Specialized services | A process its operations specifications name, such as plating or heat treating |
Service difficulty reports · 106
Reports the station filed (under its designator XC4R), newest first.
| 1995 | 24 |
|---|---|
| 1996 | 2 |
| 1997 | 13 |
| 1998 | 1 |
| 1999 | 40 |
| 2000 | 26 |
SDR 2000ZZZX587Seal · leakingBRAKE ASSEMBLY, P/N 5010520-1, FAILED PREMATURELY. FIVE EACH, PISTONS LEAKING FROM INSULATOR AREA. PISTONS INTERNALLY FILLED WITH FLUID. EVIDENCE OF T-SEAL FAILURE. THIS IS A CONTINUAL DISCREPANCY. NOTE: OEM PARTS INSTALLED IN BRAKE ASSEMBLY AND THE MOSTSDR 2000ZZZX586Seal · leakingBRAKE ASSEMBLY, P/N 5010520-1, FAILED PREMATURELY. ONE EACH, PISTON LEAKING FROM INSULATOR AREA. PISTON INTERNALLY FILLED WITH FLUID. EVIDENCE OF T-SEAL FAILURE. THIS IS A CONTINUAL DISCREPANCY. FACTORY NEW BRAKE ASSEMBLY. NOTE: OEM PARTS INSTALLED IN BSDR 2000ZZZX585Seal · leakingBRAKE ASSEMBLY, P/N 5010520-1, FAILED PREMATURELY. TWO EACH, PISTONS LEAKING FROM INSULATOR AREA. PISTONS INTERNALLY FILLED WITH FLUID. EVIDENCE OF T-SEAL FAILURE. THIS IS A CONTINUAL DISCREPANCY. FACTORY NEW BRAKE ASSEMBLY. NOTE: OEM PARTS INSTALLED IN
See all 106 reports