20260323004199I

Incident · Minor damage

FAA incident report · Embraer ERJ-170-200SU · Cincinnati, OH · March 23, 2026

Date
March 23, 2026 · 14:25 local
Place
Cincinnati, OH
Phase of flight
Takeoff: Climb Out
Operating rules
Foreign air carrier (Part 129)
Operator
NZAF
Damage
Minor damage
Aircraft
C-FEKJ
Reported as
Embraer ERJ-170-200SU
People aboard
69
Fatal injuries
0
Other injuries
0

From the FAA’s Accident/Incident Data System (AIDS), through its Aviation Safety Information Portal, as reported. The NTSB investigates accidents separately, and its record of an accident is the fuller one. The aircraft is matched to the registry by N-number and event date, checked against the reported make and model; the registry’s history has gaps, so older matches can be wrong. Compare the reported make and model.

What happened

The FAA’s narrative, in sentence case. The FAA writes it in capitals and removes private details.

Captian reported loss of pressurization on climb

Through FL220 crew descended to FL 100 right after and once at FL100 flight landed safely in yyz.

Left hand #1 pack – the #1 venturi differential pressure sensor was replaced and operational checks carried out successful.

Right hand #2 pack- the right-hand acm, right hand dual heat exchanger, and load limit by-pass valve were replaced. Operational checks were carried out successful.

Aircraft returned to service.

As the FAA filed it

CAPTIAN REPORTED LOSS OF PRESSURIZATION ON CLIMB

THROUGH FL220 CREW DESCENDED TO FL 100 RIGHT AFTER AND ONCE AT FL100 FLIGHT LANDED SAFELY IN YYZ.

LEFT HAND #1 PACK – THE #1 VENTURI DIFFERENTIAL PRESSURE SENSOR WAS REPLACED AND OPERATIONAL CHECKS CARRIED OUT SUCCESSFUL.

RIGHT HAND #2 PACK- THE RIGHT-HAND ACM, RIGHT HAND DUAL HEAT EXCHANGER, AND LOAD LIMIT BY-PASS VALVE WERE REPLACED. OPERATIONAL CHECKS WERE CARRIED OUT SUCCESSFUL.

AIRCRAFT RETURNED TO SERVICE.