SDR AALA202610190251Relay · damagedAIRCRAFT WAS GROUNDED: ON DESCENT OUT OF 10,000 FLIGHT DECK HAD AN ELECTRICAL SMELL. DISSIPATED BY 6,000. MAINTENANCE PERFOMED GVI OF COCKPIT C/B PANELS AND ALL E&E BAYS. FOUND RELAY 7HG (LH RECIRC FAN CONTROL) DAMAGED. REPLACED RELAY 7HG IAW ESPM 20-46-50. RESDR SWAA2026100891056Fan · odorACRID ODOR ON DESCENT, DISSIPATED WITH RECIRC FANS TURNED OFF. REAPPEARED WITH FANS BACK ON AT GATE. R & R LT RECIRC FAN IAW AMM 21-25-02, AND R & R LT RECIRC AIR FILTER IAW AMM 21-25-01. OPS CHECKED NORMAL AND NO ACRID ODORS.SDR CALA2026100520077Apu · odorAFTER ENG SHUTDOWN AT GATE APU BLEED ON. SMOKE FILLED CABIN SLIG HT BURN SMELL PERFORM CONDITIONAL INSPECTION PER AMM 05-51-58-910-801-C1. IAW TASK 05-51-58-910-801-C1 SMOKE/ODOR IN THE FLIGHT DECK AND/OR CABIN CONDITIONAL.