Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2140' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2140' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2023091107406Unknown · unknown(LOG 4926952) ON DEPT OUT OF MCO FA'S SMELED A BURNING SMELL, THEN DISIPATED. REMOVED AND REPLACED FWD DOOR AREA HEATER AS PER B737-800 AMM 21-45. OPS CHECK OK.SDR DALA2023082806979Unknown · unknownSHIP 3772 -DIV/FUMES- DIVERTED TO DFW DUE TO ODOR IN FORWARD GALLEY. CORRECTIVE ACTION: MAINTENANCE FOUND DOOR HEATER WITH CHARRED DEBRIS. MELD DOOR HEATER ASSY AND REPLACED RECIRCULATION FILTERS. .SDR DALA2023082106817Unknown · unknownSHIP 3576 -DIV- TO GANDER DUE TO A BURNING ELECTRICAL SMELL IN THE AFT GALLEY. CORRECTIVE ACTION: FOUND AFT GALLEY ELECTRIC SUPPLEMENTAL HEATER FAULTED. DEFERRED PER MEL 21-60-11A (20AUG23 ATL - REPLACED AFT GALLEY HEATER). (LP 4562800)SDR DALA2023081406594Unknown · unknownDURING CRUISE FLIGHT ATTENDANTS REPORTED AN ELECTRICAL SMELL NEAR THE OVENS IN THE AFT GALLEY. ALL OVEN CIRCUIT BREAKERS WERE PULLED AND SMELL DISSIPATED. CORRECTIVE ACTION: COULD NOT DUPLICATE SMELL WITH OPERATING GALLEY EQUIPMENT. FOUND TWO BURN MARKS IN GALSDR CHIA202308076438Blower · shortedDURING FLIGHT PIC/SIC NOTICED SLIGHT BURNING SMELL IN COCKPIT IN FWD FLIGHT AFTER DEPARTING DIP SITE. PIC IMMEDIATELY TURNED OFF THE HEAT VENT MASTER SWITCH, AFTER WHICH NO FURTHER SMELLS WERE NOTED. CONTINUED MISSION FOR APPROXIMATELY 15-20 MINUTES AND THEN RSDR CHIA2023F00247Blower · shortedDURING FLIGHT PIC/SIC NOTICED SLIGHT BURNING SMELL IN COCKPIT IN FWD FLIGHT AFTER DEPARTING DIP SITE. PIC IMMEDIATELY TURNED OFF THE HEAT VENT MASTER SWITCH, AFTER WHICH NO FURTHER SMELLS WERE NOTED. CONTINUED MISSION FOR APPROXIMATELY 15-20 MINUTES AND THEN RSDR DALA2023071805806Unknown · unknownSHIP 3408 CREW REST COMPARTMENT HAS LOW AIRFLOW LIGHT. ATLANTA MTC DIRECTED TO RESET VENT CONTROL LANE 1, LANE 2. (DID NOT RESOLVE LOW AIRFLOW LIGHT). ALSO, IN REST COMPARTMENT RESET THE SMOKE RESET BUTTON. NO AIRFLOW IN REST AREA. CORRECTIVE ACTION: OPERATIONSDR DALA2023061604895Unknown · unknownSHIP 1801 FLIGHT ATTENDANTS REPORT WARM ELECTRICAL SMELL IN CREW REST COMPARTMENT. CORRECTIVE ACTION: FOUND HEATERS TO BE THE SOURCE OF ELEC SMELL. FWD TO MEL 21-66-02A. MEL PLACARD INSTALLED & "M" PROC C/W (4722506)SDR HYIA20230501002Blower · failedPILOT REPORTED SMOKE SMELL IN THE COCKPIT ASSOCIATED WITH THE HEATER. MAINTENANCE INVESTIGATED AND CONFIRMED FAULT TO BE HEATER RELATED AND PLACED SYSTEM ON MEL.SDR HYIA20230421001Unknown · unknownPILOT REPORTED BURNING SMELL FROM CABIN HEATER IN CRUISE, WHICH STOPPED WITH HEATER WAS TURNED OFF. MAINTENANCE IS INSPECTING AND WILL ADDRESS THE ISSUE PRIOR TO NEXT FLIGHT.SDR HYIA20230418001Heater · failedPILOT REPORTED A SMOKE SMELL IN COCKPIT. MAINTENANCE FOUND PILOT LEG HEATER FAN TO BE INOPERATIVE. THE FAN WAS PLACED ON MEL AND WILL BE REPLACED.SDR DALA2023041603011Heater · odorSHIP 3928 - DIV - TO JAX DUE TO ELECTRICAL ODOR IN CABIN. CORRECTIVE ACTION: THE DOOR AREA HEATER CIRCUIT BREAKER FOUND TRIPPED. MAINTENANCE REPLACED THE FORWARD DOOR HEATER PER B737 AMM 21-45.SDR HYIA20230410001Blower · failedPILOT REPORTED ELECTRICAL BURNING SMELL FROM HEATER. MAINTENANCE INSPECTED AND DETERMINED THE HEATER BLOWER FAN TO BE INOPERATIVE. THE BLOWER WAS REPLACED WITH NO FURTHER DEFECTS NOTED.SDR 8HBR20230410050Shroud · buckledDURING THE AIRFRAME OVERHAUL 2 NEW CABIN HEAT MUFFLER SHROUDS PROVIDED BY ROBINSON DID NOT FIT ON THE MUFFLER PROPERLY CAUSING SEVERE BUCKLING AND DEFORMATION.SDR 9JLA2023032929737Control Valve · faultyFLIGHT CREW REPORTED EXCESSIVELY HOT AIR BLOWING FROM CABIN GASPERS WHILE IN FLIGHT, THE FLIGHT CREW WAS UNABLE TO CONTROL VIA CABIN OR FLIGHT DECK CONTROLS. THE CREW ELECTED TO DIVERT FLIGHT AND LAND. THE MAINTENANCE CREW DETERMINED THE TEMP CONTROL VALVE WASSDR DALA2023040302541Unknown · unknownSHIP 3353 DO NOT OCCUPY SIGN LENS ABOVE CREW REST DOOR MISSING. CORRECTIVE ACTION: REF ER/A 607247-14. (4090677)SDR HDNA2023032010002Ejector · activatedCREW SMELLED FUMES AFTER THE BLEED AIR HEAT WAS TURNED ON.SDR HYIA20230215001Blower · failedPILOT REPORTED ODOR OF SMOKE IN THE COCKPIT ACCOMPANIED BY THE HEATER OVERHEAT LIGHT. MAINTENANCE INSPECTED AND FOUND THE VENTILATION FAN INOPERATIVE.SDR DALA2023021401150None · noneSHIP 3311 LDMCR LOW AIR FLOW ALERT HORN DAMAGED. CORRECTIVE ACTION: REMOVED AND REPLACED LDCMR LOW AIRFLOW ALERT HORN AND TEST OK. (9842188)SDR QR9R2023021000001Ejector · failedAIRCRAFT HEATER FAILED IN MID-FLIGHT; UNABLE TO GET HEATER TO RESET. A/C RESTRICTED FROM FLYING IN TEMPS BELOW 50 DEGREES WHILE REPLACEMENT PART IS ON ORDER.SDR G1IA20230206033Heater · odorAT APPROXIMATELY 12000 FEET ON CLIMBOUT FROM KRNO, MEDCREW AND PILOT SMELLED A BURNED RUBBER SMELL. MEDIC DETERMINED THE SOURCE AS THE AFT VENTS IN THE CEILING OF THE CABIN BY THE CARGO NET. PILOT TURNED OF HEATER AND CYCLED THE FANS TO BOOST FAN AND SYTEM OSDR DALA2023020801006None · noneFA SMELLED BURNING PLASTIC SMELL WHEN THE FLOOR HEATER WAS TURNED ON IN THE AFT GALLEY. FWD TO MEL 21-23-65. REMOVED AND REPLACED AFT DUCT HEATER PER A220 EFIM SOLUTION #2-37570. C/W AMDS CARD 0550-2001 A220 ODI FOLLOW UP INFORMATION. CONTACTED MCC AND GOT APPSDR DALA2023020400876Not Reported · not reportedSHIP 3315 DURING CLB OUT PILOT ON BREAK OBSERVED LOW AIRFLOW MSG IN LDCRM. PERFORMED SDCU 1+2 RESET AND VENT CONT LANE 1/2 RESET. O2 MASKS IN REST FACILITY DEPLOYED. CORRECTIVE ACTION: NO RELATED FAULT ON PFR, STOWED CREW REST OXYGEN MASKS + PERFORMED VC TEST SDR DALA2023020300855Not Entered · not enteredSHIP 1703 ELECTRICAL BURNING SMELL MID AIRCRAFT AND GETS STRONGER IN THE AFT GALLEY. CORRECTIVE ACTION: FOUND SOURCE OF ODOR FROM BULK CARGO VENT FAN. DEFFERED PER MEL 21-40-01C (4136714)SDR EVCA011720232Heater · odorWITH HEATER TURNED ON THERE IS FUEL SMELL IN CABIN. INSPECTED WITH NO ISSUES FOUND. GROUND RAN AND COULD NOT DUPLICATE.SDR HYIA20230124002Blower Motor · failedPILOT REPORTED BURNING SMELL IN CABIN, THEY TURNED THE HEATER OFF AND SMELL DISSIPATED. MAINTENANCE INSPECTED AND FOUND THE COMBUSTION BLOWER INOPERATIVE. MAINTENANCE REPLACED THE COMBUSTION BLOWER WITH NO FURTHER DEFECTS NOTED.SDR QR9R2023010600002Heater · inoperativePRIOR TO TAKEOFF, HEATER WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED HEAT EJECTOR IAW 21-41-00, 4-1.SDR CALA2023010400023Valve · inoperativeAFT CARGO HEAT HOT AIRVALVE WILL NOT OPEN W/SEL AT FULL HOT..TRI M AIR AT C..AMB TMP 58+ DEC NO FAULTS NOTED IN FLIGHT DECK. PERFORMED POWER UP BITE TEST AMM COMPARTMENT HEATING SYSTEM AMM 21-43-00-710-003-A. FOUND AFT FROM THIS POSITION SAME WITH TRIM AIR VALSDR 2022FA0000711Actuator · defectiveTHE AIRCRAFT CAME INTO MAINTENANCE WITH THE CABIN HEATER INOPERATIVE. DURING TROUBLESHOOTING, THE IRIS VALVE WAS FOUND TO OPERATE SLOWLY AFTER APPLYING LIGHT PRESSURE TO THE ARM. THE ARM IS CONNECTED TO A CABLE THAT IS ROUTED TO THE FRESH AIR VALVE ACTUATOR BESDR DALA2022112107463Relay · inoperativeLEAD FLIGHT ATTENDANT REPORTED SMOKE SMELL AFTER LANDING, NO SMOKE VISIBLE. NO ABNORMAL INDICATIONS ON FLIGHT DECK. DISIPATED WITHIN A FEW MINUTES. REMOVED AND REPLACED DOOR AREA HEATER POWER RELAY R560 PER WDM 21-42-11 OPS CHECKS NORMAL.SDR 6CBA2022111422217Heater · smokePROBLEM: DURING A FLIGHT FROM KILG TO KPSM THE FLIGHT CREW ENCOUNTERED "SMOKE IN COCKPIT/CABIN, DISSIPATED AFTER SECURING CABIN HEAT." THEY DECLARED AN EMERGENCY AND DIVERTED TO KPNE, LANDING WITHOUT INCIDENT. RESOLUTION: THE FLIGHT CREW DISCREPANCY " SMOKE ISDR DBCA2022AA060007Heater · failed1) CREW NOTED SMOKE IN COCKPIT/CABIN AFTER TAKE OFF. 2) CREW DECLARED AN EMERGENCY AND RETURNED TO SAT. 3) MTN FOUND RH FWD CABIN ELECTRIC HEATER/FAN PCB BURNED. 4) MTN REPLACED RH FWD CABIN ELECTRIC HEATER ASSY WITH NEW.SDR DALA2022110707201Heater · odorSHIP 6822 FLT ATTD REPORTED ELECTRICAL SMELL IN FWD CABIN. NO NOTICIBLE SMELL IN COCKPIT. ON DECENT SMELL DISIPATED AND IFE BECAME INOP/ COMPLETELY SHUTDOWN. R/R IFE OMC REF LOG #9399149. PERFORMED SYSTEM TEST OF DOOR AREA HEATERS REF B757 AMM 21-45. C/W MD SDR QR9R2022110200001Ejector · failedHEATER FAILED RUN UP TEST. DURING TROUBLESHOOTING, AVIONICS CONFIRMED HEATER MIXING ASSEMBLY BAD. REMOVED AND REPLACED HEATER EJECTOR ASSY IAW AMM 21-41-00, 4-1. OPERATIONAL TEST OF THE HEATING SYSTEM COMPLETE OK AMM 05-60-00, 6-1.SDR DALA2022102106801Heater · fod(LOG 9374456) AFTER TAXI HAD COMMAND FLT ATTD REPORTED SMELLING AN ODOR SIMILAR TO A LIT MATCH FROM THE RT OVERWING DOOR AREA. PERFORMED INSP OF AFT GALLEY DOOR HEATER AND FOUND UNOPPENED EARPLUGS IN AIRSTREAM AGAINST FLOOR HEATER. CLEANED AND RE-INSTALLED FLOSDR HYIA20221005001Igniter · burnedTHE PILOT REPORTED AN ELECTRICAL SMELL IN THE COCKPIT DURING FLIGHT. MAINTENANCE INSPECTED AND FOUND THE HEATER IGNITION SYSTEM BURNT. THIS WAS REPLACED WITH NO FURTHER DEFECTS NOTED.SDR 6CBA2022092722216Heater · odorDURING FLIGHT FROM KGAI TO KGRR THE FLIGHT CREW REPORTED "STRONG ELECTRICAL BURNING SMELL NOTED IN FLIGHT." THE FLIGHT CONTINUED AND THE AIRCRAFT LANDED WITHOUT INCIDENT. RESOLUTION: ? REMOVED AND REPLACED LH AFT CABIN HEATER WITH NEW UNIT IAW PC-24 DM PC24-SDR DALA2022081705595Heater · odor(LOG 9152167) FAINT ELECTRICAL ODER IN AFT GALLEY AFTER RETURN TO GATE. INSTALLED SERVICEABLE AFT DOOR AREA HEATER PER B737 AMM 21-45. OPS CHECK GOOD.SDR 2022FA0000407Combustion Tube · burned outHARTZELL ENGINE TECHNOLOGIES (JANITROL) HEATER ASSEMBLY P/N 65D79-3IS, S/N A00020017 OVERHAULED TO ZERO-TIME ON 5/20/2013 BY THIS REPAIR STATION (IS4R269M) WITH THE INCONEL UPGRADE KIT. UPON INSPECTION WE FIND THE COMBUSTION TUBE P/N 88D95-1(IS), S/N H130410 HSDR DALA2022072805200None · noneSUPPLEMENTAL INFORMATION SHIP 3357 BURNING SMELL AFT GALLEY. WHEN TAPE HEATER CB'S WERE PULLED, SMELL STOPPED. CORRECTIVE ACTION: PERFORMED ADJUSTMENT OF THE POTENTIOMETERS. NO SMELL/SMOKE NOTED. TESTS GOOD . (9305380)SDR DALA2022110707192None · noneSHIP 3311 AFT GALLEY FLOOR HAS BURN MARK AT ENTRANCE, ABOUT WHERE ALL 3 ZONES MEET. DOOR 4 L/R AND AFT GALLEY FLOOR. CORRECTIVE ACTION: R/R AFT GALLEY HEATED FLOOR PANEL (FIN 113DS) AS PER A 330 AMM 25-27. C/W R.I. 603567-14. (8762205)SDR DALA2022110407162None · noneSHIP 3311 2R FLOOR HAS A BURN MARK AT FLT ATTENDANT SEAT AREA. CORRECTIVE ACTION: REMOVE AND REPLACED 2R HEATED FLOOR PANEL 28DS PER A330 AMM 25-27. (8762207)SDR CALA2022062901608Sensor · dirtyBULK CARGO HEAT EICAS AFTER SEVERAL MINUTES FROM OFCRA EICAS FOUND SUPPLY FAN FOD SCREEN AND BULK CARGO ZONE TEMP SENSOR FULL OF DUST . CLEANED FOD SCREEN AND TEMP SENSOR. PERFORMED AFT/ BULK TEST PASSED.TRIM AIR TEST, TEST PASSED. PERFORMED AIR DISTRUBUTION SDR 2022FA0000316None · leakingCABIN HEATER ASSY FAILS PRESSURE DECAY TEST. AIR LEAKAGE CAN BE HEARD IN CABIN AIR CHAMBER LEAKING IN FROM COMBUSTION CHAMBER.SDR AALA202206141472Heater · smokeAIRCRAFT WAS GROUNDED: GALLEY HEATER G7 IN AFT GALLEY GIVES AN ELECTRICAL SMELL/ODOR WHEN TURNED ON G8 HEATER WORKS NORMAL. **SUPPLEMENTAL REPORT FOR AALA202206091472: REMOVED AND REPLACED G7 GALLEY HEATER PER AMM 21-45-30** (CLOSED)SDR AALA202206091472None · noneAIRCRAFT WAS GROUNDED: GALLEY HEATER G7 IN AFT GALLEY GIVES AN ELECTRICAL SMELL/ODOR WHEN TURNED ON G8 HEATER WORKS NORMAL. **SUPPLEMENTAL REPORT REQUIRED** (OPEN)SDR 6CBA2022053122212Heater · faultyPROBLEM: PILOT REPORTS " SMOKE IN CABIN FROM FLOOR AREA OF LEFT HAND AFT POSITION OF CABIN; ASSOCIATED ELECTRICAL BURNING ORDER. SECURED HEATER AND SMOKE AND FUMES DISSIPATED." RESOLUTION: REMOVED AND REPLACED LH AFT CABIN ELECTRIC HEATER OFF/ON P/N:959.90.SDR ABXA202241455None · noneAFT CARGO OVHT DURING TAXI, AIRCRAFT BACK TO BLOCK AND GROUNDED BY MAINTENANCE. MAINTENANCE DEFERRED PER MEL 21-40-2-1A2. MBCB 05/24/2022. AIRCRAFT REMAINS ETOPS 180. NO MX PROCEDURES REQUIRED. AIRCRAFT RETURNED TO SERVICE.SDR DALA2022051603345Heater · inoperativeSHIP 3856 -ATB- DUE TO REPORT OF ELECTRICAL SMELL AND VISIBLE SMOKE FROM FORWARD GALLEY / R1 DOOR AREA. CORRECTIVE ACTION: C/W NO-GO-ODI INSPECTION TASKS. DETERMINED ODOR COMING FROM THE R1 DOOR HEATER. MAINTENANCE REPLACED FORWARD DOOR AREA HEATER IAW B737 AMSDR 2022F00209None · noneCREW REPORTED AN ACRID SMELL IN CABIN SHORTLY AFTER TAKEOFF, CREW DECLARED AN EMERGENCY AND DIVERTED AIRCRAFT TO KIND, MAINT RESPONDED TO AIRCRAFT AND FOUND THE SMELL WAS A RESULT OF THE ENGINES HAVING A INTERNAL CORROSION TREATMENT THAT GOT INTO THE BLEED AIR
Back to JASC 2140