Service difficulty report · Blower Motor · Cessna 402C

Difficulty date
January 8, 2023
Submitted
January 24, 2023
Operation
Air carrier
Aircraft
N205CA
Make and model
Cessna 402C
Aircraft serial
C4020207
Aircraft time
22,429 hours, 38,240 cycles
Part
Blower Motor
Part number
722099
Part serial
0311202
Condition
Failed
Location
Heater
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PILOT REPORTED BURNING SMELL IN CABIN, THEY TURNED THE HEATER OFF AND SMELL DISSIPATED. MAINTENANCE INSPECTED AND FOUND THE COMBUSTION BLOWER INOPERATIVE. MAINTENANCE REPLACED THE COMBUSTION BLOWER WITH NO FURTHER DEFECTS NOTED.