JASC 2150
Service difficulty reports · 12,393
Reports filed under 2150 · Cabin Cooling System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2016062100451Warning System · false activationLEFT PACK TEMP EICAS MSG IN CRUISE AT FL 360. PERFORMED PACK BITE CHECK IAW FIM 21-51, FT 803, NO FAULTS AT THIS TIME.SDR ASOA20160620056HSSwitch · inoperativeTHE CREW REPORTED A PACK 1 OVERLOAD ON EICAS, THE QRH WAS UNSUCCESSFUL AND THE MESSAGE REMAINED. APPROXIMATELY 20 MINUTES LATER THE F/A REPORTED SMOKE IN THE CABIN WITH THE NR 1 PACKOFF. THE CREW RAN THE CABIN SMOKE CHECKLIST AND TURNED OFF THE NR 2 PACK ANDSDR ASOA20160620057Acm · inoperativeTHE CREW REPORTED A PACK 1 OVERLOAD ON EICAS, THE QRH WAS UNSUCCESSFUL AND THE MESSAGE REMAINED. APPROXIMATELY 20 MINUTES LATER THE F/A REPORTED SMOKE IN THE CABIN WITH THE NR 1 PACK OFF. THE CREW RAN THE CABIN SMOKE CHECKLIST AND TURNED OFF THE NR 2 PACK ANSDR P5CA2016061900144Acm · malfunctionedLEFT PACK TEMP EICAS MSG ON TAXI PLACED LT PACK ON MDDR 67656 IAW MEL 21-51-01-01. MAINTENANCE PROCEDURES C/W PLACARD INSTALLED. LT PACK WILL NOT RESET IN AUTO OR STANDBY. REMOVED AND REPLACED LT ACM MM 21-51-07. REMOVED AND REPLACED HOT AIR SUPPLY TUBE IASDR HALA2016061900244Regulator · faultedETOPS SIGNIFICANT SYSTEM, AIR PACK REGULATOR 2 FAULT. T/S IAW TSM 21-53-00-810-850A. RESET PACK TEMP CONTROLS. NO FAULTS. OK FOR SERVICE.SDR ASAA2016061817057Actuator · failedLEFT RAM DOOR, FULL OPEN LIGHT ILLUMINATED THROUGH CLIMB AND AT CRUISE. ACFT GROUNDED. R & R LT RAM AIR DOOR ACTUATOR IAW AMM 21-51-21. OPS CHECK NORMAL.SDR ANCF2016061701Acm · malfunctionedDURING APPLICATION, THERE WAS SMOKE AT PAX CABIN AND A SIMULTANEOUS BURN ODOR PACK 2 WAS TURNED OFF MANUALLY AND THE SMOKE AND ODOR STOPPED, WITH PACK 1 OPERATION ONLY INCREASED EXCESSIVELY THE DUCT AND CABIN TEMPERATURE. IT WAS NECESSARY TO TURN PACK 1 OFF ASDR ASAA2016061617056Actuator · failedLEFT PACK LIGHT ILLUMINATED ON RECALL; EXTINGUISHES UPON MASTER CAUTION RESET. ACFT GROUNDED. CONFIRMED DEFECT, BITE OF LT PACK ZONE TEMP CONTROL IAW FIM 21-62, TASK 801 SHOWED RAM AIR ACTUATOR FAULT. ACCOMPLISHED T/S FOR RAM AIR ACTUATOR FAULT IAW FIM 21-SDR UIEA2016061600427Switch · faultyLT PACK BITE MAINTENANCE MESSAGE. REPLACED ALTITUDE SWITCH IAW AMM 21-51-17, OPS CHECK NORMAL.SDR P5CA2016061400139Valve · failedFWD EICAS EQUIPMENT VALVE TRANSFERRED MEL 21-58-07-02, MDDR 67490. ITEM: M-2: IAW FIM 21-58, FT 985, FOUND FWD CARGO OVERBOARD VALVE FAIL TO CLOSE IAW 21-58-43. REPLACED FDARS VALVE AND OPS CHECK OK. MDDR 67490 CLOSE. PLACARD REMOVED, MEL 21-58-07-02 PROCEDSDR ASAA2016061417035Warning System · false indicationDURING RECALL LEFT PACK LIGHT ILLUMINATED. EXTINGUISHED WITH MASTER CAUTION RESET.
COMPLIED WITH QRH. ACFT GROUNDED. RESET RT PACK TCV FAULT. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE IAW AMM 21-61-00. NO FAULTS NOTED. GROUND VERIFICATION
SUCCESSFUL.SDR VNAA2016061100017Acm · odorLEFT PACK HIGH TEMP AND BURNING ELECTRICAL ODOR IN COCKPIT. MAINTENANCE TROUBLESHOT, DEFFERED THE LT PACK AND PERFORMED CHECKS IAW THE AMM. THE ACFT WAS RELEASED FOR SERVICE. MAINTENANCE R&R LT ACM IAW AMM, OPS CHECK GOOD, LEAK CHECK GOOD. MEL CLEARED.SDR ASAA2016061116995Control Valve · malfunctionedRIGHT PACK LIGHT ILLUMINATES WITH RECALL. PACK LIGHT EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED FIM 21-62, TASK 801. FOUND CURRENT STATUS AND PREVIOUS FLIGHT FAULTS TCV ON THE NR 2 PACK/ZONE TEMP CONTROLLER. BOTH PACK/ZONE TEMP CONTRSDR ASAA2016060916994Warning Light · illuminatedRT PACK LIGHT ON RECALL. ACFT GROUNDED. ACCOMPLISHED GROUND VERIFICATION OF PACK TEMP CONTROL RIGHT SIDE BITE, REF FIM 21-62-TASK 801, NO FAULTS NOTED, RT PACK LIGHT STAYS OFF ON RECALL.SDR ASAA2016060716975Actuator · failedLT PACK LIGHT ILLUMINATED ON RECALL. EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. REMOVED AND INSTALLED LT RAM AIR EXHAUST ACUATOR, REF AMM 21-51-27. ACCOMPLISHED LT PACK/ ZONE TEMP CONTROLLER BITE, GROUND FUNCTIONAL CHECK, NORMAL, REF AMM 21-51-00-7SDR RAIA201606100002Condenser · crackedON FINAL APPROACH SMELL OF SMOKE ORIGINATING IN CABIN NO VISUAL. INSPECTED FOUND CRACKED CONDENSER/MIXER. R & R CONDENSER/MIXER. OPS CHECK GOODSDR ASAA2016060616955Warning Light · false activationRIGHT PACK LIGHT ILLUMINATES WHEN CHECKING RECALL ON MASTER CAUTION SYS. RESETS/EXTINGUISHES ON RESET. PRI OR SEC PACK SYS INOPERATIVE. ACFT GROUNDED. ON DEFERRAL.SDR UIEA2016060600405A/C Pack · faultyEICAS MSG PACK 3. NOTED STRONG FUMES IN COCKPIT. NR 3 PACK CONFIRMED FAULTY & PLACED ON DMI IAW DDG 21-51-01-01.SDR RAIA201606100001Muffler · disconnectedLOUD BANG HEARD DURING APPROACH TO RDU. SMOKE SEEN FROM BELOW 10A. TURNING OFF BLEED AND PAC STOPPED SMOKE. FOUND LT PACK MUFFLER DISCONNECTED. SECURED MUFFLER. OPS CHECK GOODSDR HNAA2016060600163Acm · failedIN ICING CONDITIONS AT CRUISE CREW NOTICED A BURNING ODOR IN THE COCKPIT AND FWD GALLEY AREA AND AFTER LANDING PACK 2 OVERHEAT AND PACK 2 OVLD EICAS MESSAGES APPEARED. DURING T/S MX FOUND METAL SHAVINGS AT OUTLET SCREEN NR 2 PACK. PERFORMED FIM TASK FOR SMOKSDR SOKF20160607003Acm · malfunctionedDURING CLIMB, AIRCRAFT RETURNED TO DEPARTURE DUE TO CABIN SMOKE ODOR, AT STATION. PERFORMED FIM 21.20.00.810.800A, AND FOUND ACM 1 DAMAGED. R & R THE ACM 1 IAW AMM 21.51.05 AND PERFORMED OPS CHECK IAW AMM 21.51.00.710.801A, OK NORMAL. THE ACFT RETURN TO NORMSDR HALA2016060400228Warning Message · false activationRT PACK TEMP EICAS MESSAGE DISPLAYED PERIODICALLY DURING CRUISE FLIGHT BUT WOULD EXTINGUISH IN 5 SEC. REAPPEARED IN THE DESCENT. TURNED SWITCH TO AUTO-N IAW QRH. MESSAGE DID NOT APPEAR IN AUTO-N. PERFORMED PACK TEMPERATURE CONTROLLER BITE PROCEDURE IAW FIM SDR SWAA2016060952721Acm · faultySTRONG ODOR ON SHORT FINAL FOLLOWED BY LEFT PACK TRIP ON TAXI IN. R & R LT AIR CYCLE MACHINE IAW MM.SDR DALA2016060604451Retainer · corrodedCORROSION RT PACK RAM AIR INLET ACTUATOR INBD BEARING RETAINER PLATE HAS SURFACE CORROSION. R & R RT PACK RAM AIR INLET ACTUATOR WITH BEARING AND BEARING RETAINER. R & R RT RAM INLET DOOR TO FOM. OPS CHECK GOOD ALL IN REF TO SWPM 20-60-06, SRM 51-40-02 P 10,SDR ASAA2016053116907Switch · failedLEFT PACK LIGHT ILLUMINATED, FOLLOWED QRH 2.12, SELECTED WARMER TEMP ALL ZONES, RESET PACK NO PACK LIGHT ON RECALL. PACK LIGHT ILLUMINATED AGAIN, ODOR OF HEAT ODOR OBSERVED IN FLIGHT DECK. SHOTDOWN PACK IAW QRH 2.12. ODOR WENT AWAY. CABIN PRESSURE STABLE ATSDR ASAA2016053116906Warning Light · false activationLEFT RAM AIR DOOR FULL OPEN LIGHT REMAINED ILLUMINATED FOR THE FIRST 3 HOURS OF FLIGHT. ACFT GROUNDED. ACCOMPLISHED FIM 21-51, TASK 803. NO FAULTS NOTED, NO HISTORY 30 DAYS.SDR ASAA2016053116904Warning Light · false activationON RECALL LT PACK LIGHT ILLUMINATED. EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROL BITE TEST IAW AMM 21-61-00. NO FAULTS NOTED. GROUND VERIFICATION SUCCESSFUL.SDR REXA2016053000960A/C Pack · malfunctionedPACKS EMIT EXCESSIVE CONDENSATION WHEN COOLING THE ACFT ON THE GND DURING HUMID CONDITIONS. UNABLE TO SEE PAX FLOOR EMER LIGHTS. PERFORMED OPERATIONAL TEST OF BOTH LT & RT PACKS IAW AMM 21-51-00. BOTH OPERATIONS CHECKED GOOD.SDR ASOA20160530034Acm · failedTHE CREW REPORTED SMOKE IN COCKPIT AND CABIN. MAINTENANCE INSPECTED AND REPLACED THE PACK NR 1 ACM. OPS CHECKS WERE GOOD.SDR SIMA20160529001A/C Pack · failedPASSENGER & FLIGHT ATTENDANT CALLED ABOUT A BURNING ODOR WHILE TAXING. SHORTLY THEREAFTER NR 2 PACK FAILED. DEFERRED IAW MEL 2144. R & R PAC 2 AQCM IAW AMM 21-51-05. OPERATIONS CHECK IS GOOD. MEL ITEM RESTORED.SDR ASOA20160528052Acm · damagedTHE CREW REPORTED SMOKE COMING FROM THE F/O'S SIDE VENT. THE ACFT RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE ACFT AND FOUND THE NR 1 ACM TO BE DAMAGED. THE ACFT WAS SUBSEQUENTLY FERRIED TO WHERE MAINTENANCE R & R THE NRSDR QMLA2016052816056Wheel · seizedAFTER COMPLETING PATIENT TRANSFER & APPROX 10 MINUTES FROM BASE, ACFT AC UNIT WAS TURNED ON. IMMEDIATELY A PECULIAR SMELL WAS NOTICED BY CREW, IN THE AFT CABIN. AC UNIT WAS TURNED OFF & THE SMELL STOPPED. LANDED AT BASE & NOTIFIED MECHANIC.SDR ANCF2016052701Acm · malfunctionedSMOKE ODOR IN PASSENGER CABIN DURING LANDING AND ECAM MAG AIR PACK 2 OVERHEAT. ACM NR 2 REMOVED IAW AMM 21-52-21, PN 983A0000-03, SN 0983A00ES000382.SDR ASAA2016052716862Warning Light · false activationUPON RECALL, AIR CONDITION AND MASTER CAUTION ILLUMINATED ALONG WITH RT PACK LIGHT. ALL LIGHTS EXTINGUISHED UPON RESET. ACFT GROUNDED. NR 2 ZONE TEMP CONT LOGGED TCV FAULT, CLEARED AND TESTED NML IAW AMM 21-61-00, GROUND CONFIRMATION SUCCESSFUL.SDR ASAA2016052716858Warning Light · false activationRIGHT PACK LIGHT ILUMINATED DURING TAXI OUT RESET WITH MASTER CAUTION. ACFT GROUNDED. SUPPLIED CONDITIONED AIR TO RT PACK AND RT PACK LIGHT DID NOT ILLUMINATE. OPS CHECK GOOD, REF FIM 21-53, TASK 804. THIS CLEARS MEL 21-32B. NO SPECIAL PROCEDURES. GROUND VSDR ASAA2016052616860Actuator · failedLT PACK LIGHT ILLUMINATED UPON RECALL AFTER ENGINE START. ACFT GROUNDED. ATTEMPTED TO DO BITE ON NR 1 IAW FIM 21-62, TASK 301 NR 1 PTC DID NOT OPERATE. FOUND RAM AIR MOD LT C/B P6-4 OUT, C/B WOULD NOT RESET. REF AMM 20-60-01, NO DEFECTS NOTED ON C/B. REMOVSDR VQIA201606080016Regulator · failedACFT EXPERIENCED AN AIR PACK NR 2 FAULT ON CLIMBOUT. THE NR 1 PACK HAD BEEN PREVIOUSLY DEFERRED IAW MEL 21-52-01-07 AND LOCKED OUT. THE FLIGHT CREW FOLLOWED FCOM AND QRH PROCEDURES AND DIVERTED. THE ACFT NEVER LOST CABIN PRESSURE. UPON ARRIVAL, TECHS REPASDR VQIA2016060800015A/C Pack · faultedACFT EXPERIENCED AN AIR PACK NR 2 FAULT ON CLIMBOUT. THE NR 1 PACK HAD BEEN PREVIOUSLY DEFERRED IAW MEL 21-52-01-07 AND LOCKED OUT. THE FLIGHT CREW FOLLOWED FCOM AND QRH PROCEDURES AND DIVERTED. THE ACFT NEVER LOST CABIN PRESSURE. UPON ARRIVAL, TECHS REPAISDR ASAA2016052516846Warning Light · false activationLEFT PACK ILLUMINATES ON MASTER CAUTION RECALL AFTER ENGINE START AND EXTINGUISHES AFTER MASTER CAUTION RESET. ACFT GROUNDED. COMPLIED WITH TEMPERATURE CONTROLLER BITE TEST IAW AMM 21-51-00-700-803, BITE CHECK RESET GOOD . OPS TEST IAW AMM TASK 21-51-00-700-8SDR ASAA2016052516845Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL, EXTINGUISHED WHEN RESET. ACFT GROUNDED. VERIFIED DISCREPANCY. PERFORMED LT PZTC BITE, REF AMM 21-51-00. FOUND RAM AIR ACTUATOR FAULT LOGGED ONE TIME. RESET FAULT. ACCOMPLISHED RAM AIR ACTUATOR INSTALL TEST, REF AMM 21-SDR AALA20160602007Acm · seizedAIRCRAFT WAS GNDED. DURING TAXI IN HEAVY SMOKE ENTERED THE CABIN. RT AIR CONDITIONING PACK WAS SHUT OFF & SMOKE DISSIPATED. FOUND RT ACM SEIZED. R & R ACM IAW AMM 21-51-03. OPERATIONAL & LEAK CHECKED NORMAL.SDR DALA2016060104273Actuator · corrodedLEFT PACK RAM AIR INLET DOOR ACTUATOR BODY AND AFT ATTACH LUG EXFOLIATED. R & R LT PACK RAM AIR INLET DOOR ACTUATOR IAW AMM 21-53-03. OPS CHECK GOOD IAW AMM 21-53.SDR YENA20160524466Control Valve · failedFOUR HOURS INTO FLIGHT, A BURNED ODOR WAS NOTICED AND PACK 1 WAS SHUTDOWN. ODOR WENT AWAY. R & R FLOW CONTROL VALVE ON NR 1 PACK IAW AMM 21-51-51. LEAK CHECK AND OPS CHECK GOOD, PASSED.SDR SCNA20160522056Bracket · brokenLT RAM AIR DOOR, GUIDE BRACKETS 1 WORN, 1 BROKEN. INSTALLED NEW GUIDE BRACKETS ON LT RAM AIR DOOR.SDR SCNA20160522055Link · crackedLEFT RAM AIR DOOR, 2 EA ATTACH LINKS CRACKED. INSTALLED NEW 2 NEW LT RAM AIR DOOR ATTACH LINKS.SDR SWAA2016052351984Acm · leakingDIVERSION & DECLARED EMER. FUMES IN CABIN ABEAM, BETWEEN ROWS 15 - 19 ON RT SIDE OF THE ACFT. FOUND ACM LEAKED. R & R RT ACM IAW AMM.SDR ASAA2016052016797Control Valve · failedLT PACK LIGHT ILLUMINATED ON MASTER CAUTION RECALL, RESET. ACFT GROUNDED. R & R V139, AMM 21-61-21/401, TASK 21-61-21, REMOVAL, 21-61-21 INSTALL, BITE, AND LEAK TEST GOOD, OPS CHECK NORMAL.SDR ASAA2016052016802Warning Light · false activationRT PACK CAME ON DURING DESCENT FOLLOWED QRH AND IT REMAINED ILLUMINATED. TURN OFF DURING TAXI TO THE GATE. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROL BITE PROCEDURE ON NR 2 CONTROLLER, NO FAULTS NOTED, SYS PASSED. PERFORMED RAM AIR ACTUATOR TEST, NO FAULTSDR UIEA2016052100343Acm · faultyLEFT PACK INOPERATIVE LIGHT. REPLACED LT PACK ACM IAW AMM 21-51-03. OPERATIONS & LEAK CHECKS GOOD.SDR ASOA20160519023Acm · odorPILOT REPORTED A LOUD HISSING NOISE BY EXIT ROW WITH PACK 2 ON WITH A BURNING ODOR IN COCKPIT. PLACED ON MEL 5/19/16, 5/21/16. MAINTENANCE R & R NR 2 AIR CYCLE MACHINE WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.
Back to JASC 2150