SDR UIEA2016051900338Warning System · false activationAT DEPARTURE LT PACK INOPERATIVE LIGHT. FOUND LT PACK OVERTEMP ON BITE BOX. RESET BOX, OPENED PACK BAY DOORS, NO PROBLEMS NOTED, SYS OK IAW AMM 21-51-03.SDR ASAA2016051816768Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL AFTER ENGINE START ON GROUND. ACFT GROUNDED. LT PACK LOGGED TCV FAULT. PERFORMED FIM 21-62 TASK 830 AND FAULT CLEARED. GROUND FUNCTIONAL TEST PASSED.SDR 29GA2016051900001Acm · odorBURNED ODOR DETECTED ON THE DESCENT, IN BOTH CABIN AND COCKPIT. R & R NR 2 AIR CYCLE MACHINE IAW SILVER T/C 21-50-03S. OPS CHECK GOOD, NO BURNED ODOR DETECTED AT THIS TIME.SDR R61A201605170362Acm · failedCREW REPORTED A STRONG ELECTRICAL ODOR IN THE FLIGHT DECK AND CABIN. AN EMERGENCY WAS NOT DECLARED AND CREW LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT, R & R PACK NR 1 AIR CYCLE MACHINE IAW AMM AND OPS CHECKED GOOD. TIMES WILL BE PROVIDED WHEN AVAILABLSDR DALA2016051804035Acm · odorFUME, RETURNED TO GATE FOR UNUSUAL ODOR. NOTICED LT PACK TEMPERATURE HIGH AND FLIGHT DECK DUCT TEMPERATURE REACHED 173 DEGREES. TURNED OFF LT PACK AND ODOR DISSIPATED. FOUND AUTO EVENT MESSAGE LEFT PACK TEMP AND LT AIR CYCLE MACHINE SEIZED. APPLIED MEL 21-SDR ASAA2016051516737Warning Light · false activationON TAXI OUT PUSH RECALL AND GET BOTH PACK LIGHTS AND ALL 3 ZONE TEMP LIGHTS. THEY RESET OFF WHEN MASTER CAUTION IS RESET. ACFT GROUNDED. BITE TESTED BOTH CONTROLLERS REF FIM 21-62, TASK 801, NO CURRENT FAULTS FOUND. PERFORMED GROUND SYSTEM TEST, NO FAULT FSDR ASAA2016051416706Warning Light · false activationRIGHT PACK LIGHT ON RECALL RESET WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED BITE CHECK IAW FIM TASK 21-61-00-810-801. NR 2 "BIT" SHOWED "RAM AIR ACT", FAULT WENT AWAY WITH "VERIFY". RAN RT PACK 10 MINUTES AND REPEATED TEST; NO FAULTS FOUND. MASTESDR ASAA2016051316708Actuator · failedRIGHT PACK LIGHT ILLUMINATES ON RECALL. PACK LIGHT RESETS WHEN MASTER CAUTION LIGHT IS PUSHED. ACFT GROUNDED. INSTALLED NEW RT RAM AIR EXHAUST ACTUATOR IAW AMM 21-51-27-400-801. OPS CHECKED GOOD. PERFORMED OPS CK ON BOTH FWD AND AFT RT RAM AIR DOOR ACTUASDR ASAA2016051116691Warning Light · false activationAFTER TAKEOFF, LEFT SIDE "PACK" LIGHT ILLUMINATED. QRH PROCEDURE ACCOMPLISHED AND LIGHT STAYED ON AFTER PUSHING RESET SWITCH. NO OTHER LIGHTS ON WHEN RUNNING QRH. UPON RECALL, AT TOP OF DESCENT, THE LIGHT WENT OUT DURING RESET. SUBSEQUENT, RECALL, ILLUMINATESDR ASAA2016051016683Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED UPON RECALL, EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. RT PACK TEMP CONTROLLER SHOWED THIS SIDE TCV FAILURE. PERFORMED PACK TEMPERATURE CONTROL. BITE PROCEDURE, FIM 21-62 TASK 801. VERIFY WAS GREEN, RESET TEMP CONTSDR ASAA2016050916675Actuator · failedRIGHT PACK LIGHT ILLUMINATES ON RECALL, EXTINGUISHES WITH RESET. ACFT GROUNDED. RIGHT PACK FAULTS SRADA INLET ACTUATOR. FAULT WILL NOT CLEAR. ACFT CHECKED AND RELEASED IAW MEL 21-5D, RT PACK RAM AIR SYS WITH SRADA INOPERATIVE. INSTALLED NEW RT RAM AIR INLSDR ASAA2016050616633Tie Rod · out of adjustLEFT RAM AIR INLET DEFLECTOR DOOR OVERCENTER LINKS DO NOT OVERCENTER, DOOR CLOSES WITH HAND PRESSURE WITH OUT DEFLECTING LINKS. ACFT GROUNDED. ADJUSTED THE DEFLECTOR DOOR TIE ROD ASSY. VERIFIED CORRECT ADJUSTMENT OF ACTUATOR ROD END REF AMM 21-51-22-400-803SDR ASAA2016050616632Warning Light · false activationWITH MASTER CAUTION RECALL INITIATED, FOLLOWING LIGHTS ILLUMINATED: MASTER CAUTION, AIR COND, "PACK" LIGHT ON PRESSURIZATION PANEL, LEFT PACK. MASTER CAUTION RESET SEES ALL LIGHTS EXTINGUISHED. ACFT GROUNDED. ACCOMPLISHED GROUND VERIFICATION OF "PACK TEMP CSDR AALA20160509013Acm · overservicedAIRCRAFT WAS GNDED. AFTER DESCENT & LEVEL AT 6000 FEET, AN OIL SMELL WAS NOTICED IN THE COCKPIT. THIS WAS AGAIN NOTICED WHILE TAXING WITH RT ENG E SHUTDOWN & APU RUNNING. MX ACCOMPLISHED MCM CARD 21-91-01 & FOUND LT PACK TURBINE EXCESSIVELY OVER SERVICED. SDR P5CA2016050600099Relay · malfunctioned1 MINUTE BEFORE LANDING, FWD EQUIPMENT COOLING, EICAS MSG ON. REPLACED TIME DELAY RELAY K698 ON P36 PANEL REF WDM 21-58-02. OPS CHECK NORMAL AT THIS TIME MCC INFORMED.SDR ASOA201605050043Acm · seizedTHE CREW REPORTED A BURNING ODOR FOLLOWED BY SMOKE IN THE FLIGHT DECK WHILE CLIMBING THROUGH 10,000 FT. THE ACFT RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE R & R THE NR 1 ACM, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE ACFT WSDR ASAA2016050416620Warning Light · false activationON MASTER CAUTION RECALL, LT PACK AMBER OVERHEAD LIGHT ILLUMINATED. EXTINGUISHES ON MASTER CAUTION WARNING RESET. ACFT GROUNDED. ACCOMPLISHED FIM TASK 21-62, TASK 801. NO FAULTS FOUND. GROUND VERIFICATION GOOD REF FIM 21-62, TASK 848. CLEARS MEL 21-32B.SDR 7C7A2016050300241Acm · leakingBURNING SMELL & SMOKING HAZE SEEN COMING FROM GASPER WITH HEAT IN MANUAL AT FULL HOT. STOPPED WHEN HEAT WAS TURNED OFF. R & R ACM DUE TO LEAKING OIL INTERNALLY. OPERATIONS CHECKED CABIN HEAT SYS IAW MM 21-60-01. CHECKS GOOD, OK FOR SERVICE.SDR SWIA201642096A/C Pack · leakingLEFT 14TH DUCT WARNING WITH SYS OFF, RED FLOW BAR ON LT COWL/PYLON. FOLLOWED QRH AND MSG DID NOT EXTINGUISH. DIVERTED, DECLARED EMERGENCY. HOT AIR LEAK COMING FROM FWD OF THE LT PACK. THE HOT AIR IS BLOWING ON THE 14TH STAGE LOOP CAUSING WARNING MESSAGE. RSDR ASOA20160502021Acm · seizedPILOT REPORTED SMOKE IN COCKPIT AND CABIN DURING FLIGHT. MAINTENANCE R & R THE NR 2 AIR CYCLE MACHINE WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASAA2016050116582Valve · faultedM/C RECALL, CONT CABIN ZONE TEMP LIGHT ILLUMINATES ON CRUISE. EXTINGUISHES ON RESET. ACFT GROUNDED. FOUND MASTER CAUTION RECALL WILL NOT WILL NOT RECALL ZONE TEMP. FAULT NO LONGER PRESENT. CLEANED ALL 3 CABIN TEMP SENSORS FILTERS IAW MM 21-61-06-100-801. ACSDR ASAA2016050116583Warning Light · false activationLEFT PACK LIGHT ILLUMINATES ON RECALL. EXTINGUISHES WHEN MASTER CAUTION IS RESET. ACFT GROUNDED. ACCOMPLISHED FIM 21-62, TASK 801 PACK TEMP CONTROLLER BITE NR 1 PTC FAULTED FWD SRADA, WAS ABLE TO CLEAR/RESET FAULT AND REACCOMPLISHED BITE WITH NO FURTHER DISCSDR ASAA2016042916564Control Valve · failedLT PACK CAUTION LIGHT ILLUMINATES ON RECALL CANCELS W/ MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED BITE TEST OF NR 1 ZONE TEMP CONTROLLER REF AMM TASK 21-61-00-810-801. ZONE TEMP CONTROL INDICATES TCV FAILURE. REPLACED LT PACK TEMP CONTROL VALVE REF AMM SDR WX0A2016042973146Acm · overservicedDURING CLIMB OUT HEARD REAR LAVATORY SMOKE DETECTORS GOING OFF. RAN QRH 26.9, FLIGHT ATTENDANT CONFIRMED VISUAL SMOKE WAS PRESENT, NOT THE TYPICAL SUMMERTIME SMELL. SMOKE DISSIPATED UPON LANDING. BURNING ELEC SMELL CAME BACK, CB`S PULLED IAW QRH. PERFORMEDSDR DALA2016050303575Inlet · crackedDURING SERVICE CHECK, FOUND RT SIDE OF RAM AIR INLET CRACKED IN 2 PLACES. REMOVED CRACKED RAM AIR, Y-DUCT IAW AMM 21-20-17-201. INSTALLED SERVICEABLE Y DUCT IAW AMM 21-20-17 LEAK CHECK GOOD. OK FOR SERVICE.SDR ASAA2016042616540Warning Light · false activationRAM DOOR OPEN LIGHT ILLUMINATED. ACFT GROUNDED. AFTER TALKING WITH PILOT RT RAM AIR DOOR LIGHT ILLUMINATED ALL THE TIME IN FLT. ACCOMPLISHED FIM 21-51, TASK 803. ACCOMPLISHED STEPS 803A1- G11E BITE TEST NO FAULTS NOTED BOTH FWD AND AFT ACTUATORS GREEN LIGHTSDR P5CA2016042400085Warning Message · false activationFWD EQUIPMENT COOL, EICAS, OPERATED IN OVERHEAD. CW FIM 21-58, FT 902 COULD NOT DUPLICATE ON GROUND OPS CHECK GOOD AT THIS TIME.SDR GTIA2016042201528Filter · dirtyNR 1 A/C PACK, ODOR IN THE CABIN. R & R NR 1 A/C PACK RECIRCULATING FILTER IAW AMM 21-21-41.SDR ASAA2016042116500Controller · failedRT PACK PRIMARY TEMP CONTROLLER INOPERATIVE. ACFT GROUNDED. PERFORMED A PACK/ZONE TEMP CONTROLLER BITE IAW AMM 21-61-00-700-806-002. NO FAULTS NOTED. NOTICED THAT THE RT PACK PRIMARY TEMP CONTROL VALVE WAS MOVING SLOWER THAN NORMAL, WITH AN ABNORMAL GRINDISDR QMLA2016042016042Inlet Screen · obstructedAT APPROX 2000 LOCAL TIME, DURING CRUISE FLIGHT, CREW COMPLAINED OF AN ELEC BURNING SMELL. PILOT NOTICED IT SOON AFTERWARD. SHUT OFF A/C, SMELL REMAINED BUT FADED SLIGHTLY. TURNED A/C BACK ON & SMELL GOT MUCH STRONGER. TURNED OFF A/C, OPENED ALL VENTS, MONSDR ASAA2016041916466Warning Light · false activationRIGHT PACK LIGHT ON RECALL. ACFT GROUNDED. COULD NOT DUPLICATE PROBLEM. RT PACK LIGHT DOES NOT ILLUMINATE WITH RECALL AND PERFORMED BITE TEST OF BOTH PACK/ZONE TEMP CONTROLLERS IAW AMM 21-61-00, OPS NORMAL. NO FAULTS FOUND.SDR ASAA2016041916465Warning Light · false activationRIGHT RAM AIR FULL OPEN LIGHT WILL NOT EXTINGUISH. ACFT GROUNDED. ACCOMPLISHED RAM DOOR FULL OPEN LIGHT STAYS ON AIRPLANE IN THE AIR-FAULT ISOLATION, REF FIM 21-51, TASK 803. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST, BOTH NR 1 AND NR 2 CONTROLLER PASSEDSDR ASAA2016041716437Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. CONTROLLER LOGGED TCV FAULT, ACCOMPLISHED BOTH TEMP CONTROLLERS BITE TEST IAW AMM TASK 21-51-00 AND FAULT CLEARED. BOTH CONTROLLERS BITE CHECK OPS CHECK GOOD, NO EXISTING FAULT.SDR VNAA2016041600017A/C Pack · malfunctionedDURING CLIMBOUT, THE CREW RECEIVED A RT PACK FAULT AND RT PACK HIGH PRESSURE WHEN COMPLYING WITH MEL PROCEDURES FOR THE LT PACK. MAINTENANCE INTEROGATED AND FOUND NO RELATED FAULTS FOR THE RT PACK AND COULD NOT DUPLICATE THE ISSSUE. MAINTENANCE PERFORMED CHECSDR P5CA2016041600076Relay · looseDURING DESCENT, FWD EQUIPMENT VALVE , COMPLIED WITH QRH; CHAPTER 2.24 AFTER 30 SECONDS FWD EQUIPMENT VALVE EICAS MESSAGE AND LIGHT, VALVE, STILL ILLUMINATED. IAW SSM 21-58-41 REACTIVE NORMAL CND AND CHECK FOUND K2198 RELAY BASE LOOSENED, RETIGHTEN THEN OPERASDR ASAA2016041616409Warning Light · false activationRIGHT PACK LIGHT ILLUMINATES. CLEARS ON MASTER CAUTION RESET. ACFT GROUNDED. HAD PACK SENSOR FAULT ON INITIAL BITE. RESET SYS, GROUND FUNCTIONAL CHECK GOOD IAW AMM 21-61-00-700-806-002, NO HISTORY LAST 10 DAYS.SDR ASAA2016041516408Control Valve · failedAFTER PUSHBACK ON RECALL LT PACK LIGHT, MC AND AIR COND LIGHT ILLUMINATED. RESET AND ALL LIGHT EXTINGUISHED. ACFT GROUNDED. PERFORMED BITE CHECK, FOUND TEMP CONTROL VALVE ISSUE FAULT CODE 21-51266 AND 21-51267. REMOVED LT TEMP CONTROL VALVE, REF AMM 21-51-SDR SWAA2016041851011Acm · leakingAIR TURN BACK, DECLARED EMER JUST OUT OF 10,000'. FLIGHT ATTENDANT CALLED TO INFORM OF SMOKE SMELL IN CABIN. FOUND RT ACM LEAKED OIL INTERNALLY. R & R RT ACM IAW MM.SDR FDEA201604141222Transmitter · damagedUPON TAKEOFF ON 18L, ECAM INDICATED A MAIN DECK CARGO FIRE. RETURNED TO RNWY 18C WITH AN OVERWEIGHT LANDING OF 311.0. DURING T/S IAW TSI 21-60/0903, NR 1 PACK FLOW INDICATION INDICATING FULL FLOW WITH PACK OFF. FOUND NR 1 PACK FLOW TRANSMITTER (13WV) DAMAGESDR P5CA2016041400075Relay · failedEICAS MSG FWD EQUIPMENT VALUE. FOUND RELAY K10723 FAILED AND OVERBOARD EXHAUST VALVE FAILED, REF SSM 21-58-41 REPLACED RELAY K10723 AND PFM OVERBOARD VALVE T/S, FND VALVE ACTUATOR STUCK BY INSULATION BLANKET, REMOVED STUCK INSULATION BLANKET THEN OPERATOR TSDR ASAA2016041216368Control Valve · failedLEFT SIDE PACK CONTROL TRIP. RESET DURING MASTER CAUTION RESET. ACFT GROUNDED. LT PZTC LOGGED TCV FAULT. TCV PASSES INITIAL BITE CHECK. R & R LT PACK TCV. OPS CHECK NORMAL, REF AMM 21-51-00.SDR SIMA20160411002A/C Pack · surgesRIGHT PACK SURGING INTERMITTENTLY DURING FLIGHT. PERFORMED OPERATIONS CHECK OF ENG 2 PRSOV IAW AMM 36-12-01 & ETN CR-36-008. NO FURTHER DEFECTS NOTED.SDR ASAA2016040616261Valve · failedON RECALL, LT PACK LIGHT ILLUMINATES. ACFT GROUNDED. PERFORMED BITE TEST OF PACK/ZONE TEMP CONTROLLERS, REF AMM 21-61-00. CONFIRMED RED FAULT LIGHT "TCV THIS PACK" ILLUM ON NR 1 CONTROLLER, AND OVERHEAD LT PACK LIGHT STILL ILLUMINATED UPON RECALL. CONTINUEDSDR REXA2016040500552Acm · malfunctioned4 MINUTES AFTER ENG START UP SMOKE & ACRID SMELL IN CABIN, RETURNED TO GATE. DEFERRED RT PACK IAW MEL 21-51-1A. PLACARD INSTALLED MM02 UPDATED. R & R ACM IAW JC 900-21-902. OPERATIONS CHECKED GOOD. PLACARD REMOVED & MM02 UPDATED.SDR ASAA2016040516246Actuator · failedRIGHT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. PERFORMED RT PACK TEMP CONTROL BITE, REF AMM 21-62, TASK 801, RAM AIR ACTUATOR LOGGED ON RECENT FLIGHTS. DUE TO REPEATED WRITE UPS, R & R RT RAM AIR INLET ACTUATOR, REF AMM 21-51-21. RAM AIR INLET ACTUASDR ASAA2016040516247Warning Light · false activationLEFT PACK LIGHT ILLUMINATES, BON ON MASTER CAUTION RECALL CANCELS WHEN MASTER CAUTION LIGHT PRESSED TO RESET. ACFT GROUNDED. RAN SYS TEST IAW AMM 21-61-00, SYS OPS CHECKS GOOD.SDR F3LA2016040600015Acm · malfunctionedLOG PAGE 981218, AFTER TAKEOFF THE FLIGHT CREW NOTED SMOKE IN THE AFT CABIN. THE FLIGHT DECLARED AN EMER & RETURNED TO THE FIELD. FOUND THE NR 2 PACK INOPERATIVE. APPLIED MEL 21-52-01E CONTROL NR 1120060. R & R NR 2 ACM IAW AMM 21-52-21 PAGE BREAK 401. OPSDR ASAA2016040416234Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED ON RECALL AND EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED RT PACK/ ZONE TEMP CONTROLLER BITE TEST, REF AMM 21-61-00-700-806-002. FAULT LIGHT CLEARED ON VERIFY. CLEARED WITH RESET.SDR AALA20160403004Acm · leakingAIRCRAFT WAS GNDED. AIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT OVERWEIGHT. DURING CLIMB, FLIGHT ATTENDANT REPORTED SMOKE FROM TAIL CONE AREA. ACCOMPLISHED CABIN ODOR TROUBLESHOOTING CARD MCM 21-96-01 & FOUND LT AIR CYCLE MACHINE LEAKING OIL. RSDR ASAA2016040316221Controller · malfunctionedLEFT PACK LIGHT ON AFTER RECALL, AFTER START. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST ON BOTH CONTROLLERS, REF AMM 21-61-00, TCV REF LIGHT ILLUMINATED. RESET THE PACK/ZONE TEMP CONTROLLERS. RAN LT PACK ON HIGH FOR 5 MINUTES, NO FAULTS.
Back to JASC 2150