JASC 2150
Service difficulty reports · 12,393
Reports filed under 2150 · Cabin Cooling System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20160403001Accessory Unit · faultyAIRCRAFT WAS GNDED. AIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT WAS OVERWEIGHT. DURING CLIMB, FWD CABIN DUCT TEMP REACHED 140 DEGREES C. CONT CAB & FWD CABIN, ILLUMINATED, UNABLE TO CONTROL. R & R TRIM AIR MODULATION FWD VLV V144 IAW AMM 21-61-SDR ASAA2016033016164Actuator · failedON CLIMBOUT THE LT PACK TRIP, AMBER, LIGHT ILLUMINATED, 12,000 FT. WE RAN THE QRH AND THE LIGHT EXTINGUISHED. ACFT GROUNDED. R & R LT RAM AIR INLET ACTUATOR, REF AMM 21-51-21/401. PERFORMED RAM AIR INLET DEFLECTOR DOOR AND MODULATIONS PANEL ADJUSTMENT ON INSDR ASAA2016033016165Valve · failedRIGHT PACK LIGHT ILLUMINATED UPON RECALL, EXTINGUISHED WITH RESET. ACFT GROUNDED. PERFORMED PACK ZONE TEMP CONTROL BITE IAW FIM 21-62, TASK 801. RT CONTROLLER FAULTED THIS PACK TCV IAW FIM 21-62, TASK 831, FAULTS RT TCV. REMOVED RT PACK TEMP CONTROL VALVE ISDR ASAA2016032916143Control Valve · failedRIGHT PACK ILLUMINATES ON RECALL. UNABLE TO CONTROL TEMP ON RT PACK. ACFT GROUNDED. NR 2 ZONE TEMP CONTROL BITE THIS PACK TCV. R & R THE RT PACK TEMPERATURE CONTROL VALVE, IAW AMM 21-51-10/401. OPS CHECKED NORMAL, NO LEAKS NOTED. NR 2 ZONE TEMP CONTROLLERSDR ASOA20160328030HSAcm · inoperativeSUP: MAINTENANCE R & R THE NR 2 ACM, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, REMOVED THE MEK, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASAA2016032816116Warning Light · false activationAFTER TAKEOFF, PASSING THROUGH 12,000 FT LT PACK ILLUMINATED. RAN QRH PROCEDURE AND PACK LIGHT EXTINGUISHED. ACFT GROUNDED. FAULT CODE 215-280-41 LT SIDE "PACK LIGHT ON DURING CLIMB, LIGHT STAYS OUT AFTER RESET". PERFORMED FIM 21-53, TASK 805, NO DEFECTS SDR ASOA20160328030HA/C Pack · smokeTHE CREW REPORTED THAT SMOKE COMES OUT WHEN NR 2 PACK WAS TURNED ON. MAINTENANCE PLACED THE NR 2 PACK ON MEL 21-51-00-3, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASAA2016032716103A/C Pack · malfunctionedUNABLE TO COOL DOWN CABIN TEMP WITH PASSENGER CABIN FWD OR AFT CABIN TEMPERATURE SELECTORS, COMPLIED WITH, CABIN TEMPERATURE HOT, ABNORMAL CHECKLIST. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TESTS, BOTH CONTROLLERS. INITIALLY NR 2 TCV LIGHT, TSDR AALA20160407008Acm · faultyAIRCRAFT WAS GNDED. DURING CLIMB A STRONG ODOR LASTING APPROX 7 MINUTES WAS REPORTED IN THE COCKPIT. FOUND LT ACM FAILING. R & R LT ACM.SDR ASAA2016032516083Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED DURING RECALL, WENT OUT WHEN MASTER CAUTION PRESSED. ACFT GROUNDED. PERFORMED LT AND RT PFTC BITE TEST IAW AMM TASK 21-61-00-740-801-002, ALL TESTS PASSED WITHOUT EXISTING FAULTS. BOTH PACKS OPS CHECKED NORMAL.SDR AALA201603259004Reheater · odorAIRCRAFT WAS GNDED. ON TAKEOFF OIL BURNING SMELL TURNED OFF NR 1 PACK SMELL WENT AWAY. FOUND LT PACK REHEATER HAD MOLD & DIRTY MUSTY SMELL. REPLACED IT IAW AMM 21-52-31-400-001-A. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECKS WITH NO ODORS BEING NOTED.SDR QMLA2016032316028Belt · overheatedAIR CONDITIONER COMPRESSOR BELT OVER HEATED & BROKEN.SDR ASAA2016032216058Warning Light · false activationRIGHT PACK LIGHT ILLUMINATES ON RECALL EXTINGUISHING ON MASTER CAUTION RESET. PERFORMED BITE TEST ON RT PACK TEMP CONTROLLER. FOUND TCV FAULTED. RESET PACK TEMP CONTROLLER. TCV FAULT EXTINGUISHED. PERFORMED OPS CHECK ON RT TCV IAW AMM 21-61-00, NO FAULTS NSDR ASAA2016032116045Control Valve · malfunctionedRIGHT PACK LIGHT ILLUMINATED ON RECALL. LIGHT EXTINGUISHED WHEN MASTER CAUTION RESET. ACFT GROUNDED. R & R RT FLOW CONTROL AND SHUTOFF VALVE IAW AMM 21-51-01, OPS TEST GOOD, RT PACK LIGHT STAYS OFF WHEN RECALL PUSHED. NO OTHER DEFECTS NOTED.SDR ASAA2016032116044Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED ON RECALL DURING DESCENT CHECKLIST. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST, REF AMM TASK 21-61-00-700-806-002, ON RT PACK AND FOUND RAM AIR ACTUATOR LIGHT ILLUMINATED AFTER BIT BUTTON PUSHED, CONTINUED TEST ASDR ASAA2016032016019Warning Light · false activationRIGHT PACK LIGHT ON RECALL, CLEARS WITH CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROL BITE PROCEDURE ON NR 2 CONTROLLER, SHOWED TCU FAULT. RESET NR 2 CONTROLLER CLEARED FAULT REF FIM 21-62, TASK 801. RAN RIGHT PACK FOR 20 MINS, NO FAULTS NOTESDR ASAA2016031915994Warning Light · false activationLEFT PACK ILLUMINATED ON RECALL,THE LIGHT EXTINGUISHES WHEN MASTER CAUTION SYS IS RESET. ACFT GROUNDED. PACK LIGHT EXTINGUISHED ON RESTART AND REMAINED EXTINGUISHED REMAINDER OF FLIGHT, DOES NOT ILLUMINATE ON RECALL.ACCOMPLISHED PACK CONTROLLER BITE AND ALL SDR ASAA2016031915991Warning Light · false activationLEFT PACK ILLUMINATED ON RECALL, EXTINGUISHED ON RESET. ACFT GROUNDED. PERFORMED BITE CHECK OF NR 1 CONTROLLER. FAULT SHOWS RAM AIR ACTUATOR. FAULT RESET AND BITE TEST NORMAL REF AMM 21-61-00.SDR 2016F00090Valve · misrepairedAFTER THE REPLACEMENT OF THE NR 1 AIR CONDITIONING PACK CONTROL VALVE WITH A REPAIRED VALVE, DURING THE OPS CHECK OF THE VALVE, IT CAUSED THE CIRCUIT BREAKER TO OPEN, FAILING THE TEST. A REVIEW OF THE TEARDOWN REPORT INDICATED THAT THE VALVE REPAIR WAS REQUIRSDR ASAA2016031515940Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. ENROUTE MEL ACCOMPLISHED BY CREW. ACCOMPLISHED FIM TASK 21-62, TASK 802. NO FAULTS FOUND. GROUND VERIFICATION CHECKS NORMAL.SDR GTIA2016031401501A/C Pack · odorDIVERTED BECAUSE OF CABIN ODOR OF BURNING RUBBER. UPON ARRIVAL, FOUND PIECE HANGING OFF NR 1 ENGINE RESECURED NR 1 END T/R SEAL IAW CMM 78-11-11. PERFORMED GENERAL VISUAL INSPECTION OF CABIN WITH NO DEFECT OR ODORS NOTED. IAW TSM 05-50-00-810-831-A PERFORMESDR ASAA2016031415993Sensor · failedFOLLOW-UP TO HISTORY OF RT RAM AIR FULL OPEN LIGHT REMAINING ON DURING FLIGHT. ACFT GROUNDED. ACCOMPLISHED STEPS 6 AND 7 IAW FIM 21-51, TASK 803 & RT RAM AIR SENSOR T482 REPLACED IAW AMM 21-51-50, ALL OPS NORMAL. NO DEFECTS OR FAULTS FOUND. AIR/GROUND OVERRSDR ASAA2016031415903Controller · malfunctionedALL PACK TEMP CONTROLLERS IN OFF ON ARRIVAL TO ACFT. ALL ZONE TEMP LIGHTS AND BOTH PACK LIGHTS ILLUMINATE ON RECALL. CANCEL WITH MASTER CAUTION. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP BITE IAW AMM 21-61-00-700-806-002, NO FAULTS.SDR ASAA2016031415902Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED ON TAXI OUT. ACFT GROUNDED. PERFORMED PACK TEMP CONTROLLER BITE RT SIDE, LOGGED RT EXIT RAM FAULT PREVIOUS FLT. FAULT CLEARED AND SYSTEM BITES NORMAL, REF FIM 21-62, TASK 801 AND 21-62, TASK 854.SDR ASAA2016031315888Actuator · failedBLUE RAM DOOR FULL OPEN LIGHT WAS ILLUMINATED FOR THE ENTIRE FLIGHT. ACFT GROUNDED. R & R THE RT RAM AIR EXHAUST ACTUATOR, IAW AMM 21-51-27/401. OPS AND BITE CHECKED GOOD.SDR ASAA2016031015861Warning Light · false activationAFTER START, RT PACK LIGHT ILLUMINATED UP RECALL, IT EXTINGUISHED ON MASTER CAUTION PUSH TO RESET. ACFT GROUNDED. ACCOMPLISHED BITE CHECK, REF FIM TASK 21-61, TASK 801. NO FAULT FOUND.SDR ASAA2016030915842Heat Exchanger · crackedLEFT PRIMARY HEAT EXCHANGER CRACKED ON LOWER SURFACE. ACFT GROUNDED. R & R THE LT PRIMARY HEAT EXCHANGER REF AMM 21-51-03-400-804-002. LEAK AND OPS CHECK GOOD.SDR UIEA2016031000134Bulb · unsecureTEMP BULBS, THREE EACH ARE NOT SAFETIED IN RT PACK BAY. SAFETIED THREE EACH TEMP BULBS IN RT PACK BAY IAW AMM 21-52-02 & AMM 20-10-23.SDR UIEA2016031000133Bulb · unsecureTEMP BULB IN LT AC PACK BAY NOT SAFETIED. SAFETIED ONE EACH TEMP BULB IN LT PACK BAY IAW AMM 21-52-02 & AMM 20-10-23.SDR AALA20160308003Hose · rupturedAT 34,000 FT, GOT PRESSURIZATION FLOW LIGHT ON. DESCENDED TO 25,000 FT. AT 25,000 FT, THE CABIN DEPRESSURIZED. THE CREW DONNED OXYGEN MASKS & PERFORMED EMER DESCENT TO 10,000 FT. AN EMER WAS DECLARED. OXYGEN MASKS DEPLOYED IN THE CABIN WHEN CABIN ALTITUDESDR HALA2016030701776Warning Message · activatedCREW DIVERTED THE FLIGHT DUE TO PACK 2 OVERHEAT. SHUTDOWN PACK 2 AFTER COOLING RESET, PACK 2 OPS NORMAL. RIGHT REGULATOR FAULT STILL DISPLAYED ON ECAM. REPLACED NR 2 FLAP INLET ACTUATOR IAW AMM 21-53-51, NO HELP. VERIFIED TO BE IN FULL OPEN POSITION.SDR HALA2016030600074Actuator · failedPACK 2 OVERHEAT SHUTDOWN, PACK 2 AFTER COOLING RESET, PACK 2 OPS NORMAL, RT REGULAR FAULT STILL DISPLAYED ON ECAM. REPLACED NR 2 FLAP INLET ACTUATOR IAW AMM 21-53-51, NO HELP. FWD TO MEL 21-53-04. VERIFIED TO BE IN FULL OPEN POSITION, DMI 54818, PLACARD ANDSDR CA160307004Housing · cracked(CAN) WHILE REPLACING THE ACM FOR AN UNRELATED ISSUE, IT WAS FOUND TO HAVE A CRACK INTERNALLY IN THE HOUSING CAUSING AN OIL LEAK WITH SMOKE IN THE CABIN.SDR A6WA201643683A/C Pack · contaminatedUNBEARABLE ORANGE SMELL IN CABIN, STARTED WHEN PACK TURNED ON. PERFORMED PACK BURN OUT IAW AMM 09-037A FOR RT PACK, NO FURTHER ORANGE SMELL IN CABIN OR COCKPIT.SDR A6WA201643646Acm · malfunctionedLEFT PACK TEMP 118, SHUTDOWN PACK. RECEIVED SMOKE IN COCKPIT. INSPECTED LT PACK & DUCT WORK IN AFT EQUIPMENT BAY. NO DAMAGE NOTED. VERIFIED NO SMOKE IN COCKPIT. PLACED ON MEL MARCH 07 2016. R & R LT PACK ACM IAW AMM 21-51-00. OPERATIONS CHECKED GOOD.SDR ASAA2016030515743Actuator · failedLEFT PACK LIGHT ILLUMINATES ON RECALL AND EXTINGUISHES WHEN MASTER CAUTION IS RESET. ACFT GROUNDED. ACCOMPLISHED PACK ZONE TEMPERATURE CONTROLLER BITE AND FOUND CURRENT FAULT AND PREVIOUS FAULT OF LT PACK RAM AIR DOOR ACTUATOR. REMOVED RAM AIR ACTUATOR REF AMSDR YENA20160303219Filter · failedREF BURNING PLASTIC, RUBBER ODOR IN COCKPIT IMMEDIATELY AFTER ENGINE SHUTDOWN. PERFORMED TSM 05-50-00-810-831-A, RUN BOTH ENGINES WITH PACKS ON. R & R PACK 1 OZONE FILTER IAW AMM 21-51-41. OPS CHECK GOOD.SDR ASAA2016030315742Actuator · failedAFTER ENGINE START, PUSHED RECALL AND LT PACK LIGHT ILLUMINATED. FOLLOWED QRH PROCEDURES AND LIGHT EXTINGUISHED. ACFT GROUNDED. PERFORMED TEMPERATURE CONTROLLER BITE TEST ON LT PACK REF AMM 21-61-00-700-806-002. FOUND SRADA INLET LIGHT ILLUMINATE ON PREV FSDR ASAA2016030215724Bearing · roughON RECALL, THE LT PACK LIGHT ILLUMINATES. ACFT GROUNDED. DURING TROUBLESHOOTING OF LT PACK ISSUE, FOUND LT RAM AIR INLET DOOR NOT MOVING SMOOTHLY. REPLACED LT RAM AIR INLET DEFLECTOR DOOR SHAFT BEARING IAW AMM 21-51-22. PERFORMED PACK/ZONE TEMP CONTROLLER SDR ASAA2016030215723Heat Exchanger · crackedRIGHT PLENUM AND HEAT EXCHANGER FOR THE PRIMARY BROKEN AND CRACKED. ACFT GROUNDED. R & R PRIMARY RT PLENUM AND HEAT EXCHANGER ASSY REF AMM 21-51-03-000-804-002 AND AMM 21-51-03-804-002, 21-51-03-400. PERFORMED HEAT EXCHANGER AND PLENUM/DIFFUSER INSTALLATION SDR ASAA2016030215722Actuator · failedRIGHT PACK LIGHT ILLUMINATES ON RECALL, EXTINGUISHES ON RESET. ACFT GROUNDED. RIGHT PZTC LOGGED RAM AIR ACTUATOR FAULT. R & R RT RAM AIR ACTUATOR. OPS CHECK NORMAL, REF AMM 21-51-21.SDR WX0A2016030273098Control Valve · malfunctionedWHILE IN CRUISE FLIGHT THE CREW NOTED THAT THE CABIN PRESSURIZATION WAS CLIMBING. CREW WENT TO THE QRH, BUT THERE WAS NO CHECKLIST FOR CABIN DEPRESSURIZATION. ONCE THE CABIN REACHED 11000 FT THE CREW DECLARED AN EMER & EXECUTED AN EMER DESCENT. AT THAT POINSDR ASAA2016030115710Warning Light · false activationRIGHT RAM DOOR FULL OPEN LIGHT DID NOT GO OUT AND REMAINED ON ENTIRE FLIGHT. ACFT GROUNDED. CHECKED AND RELEASED ACFT IAW MEL 21-5D, RT RAM AIR DOOR INOPERATIVE. FOLLOWED FIM 21-51, TASK 803 THROUGH STEP G, 11, E. BITE CHECK & OPS CHECKS GOOD. RAM AIR DOOR SDR ASAA2016030115709Warning Light · illuminatedLEFT AND RIGHT PACK LIGHT ON WHEN RECALL PRESSED AND ONLY WITH ALL TEMP SELECTORS IN OFF POSITION. ACFT GROUNDED. ACCOMPLISHED BITE PROCEDURE IAW FIM 21-62, TASK 801, NO EXISTING FAULTS NOTED IAW EA 900ER-21EA-16652. ACFT IS OK TO RETURN TO SERVICE WITH NO SDR WNDA2016FA0000105Acm · overheatedON CLIMBOUT AFTER TAKEOFF, PILOT NOTICED SMOKE IN THE CABIN FOLLOWED BY RT PAC OVERHEAT LIGHT. AFTER FURTHER INVESTIGATION BY MAINTENANCE FOUND THE RT AIR CYCLE MACHINE TO HAVE A LOCK UP IMPELLER SHAFT.SDR ASAA2016022915696Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. PERFORMED FIM 21-62, TASK 848, THEN PERFORMED BITE CHECK ON LT AND RT PACK TEMP CONTROLLERS. REF FIM 21-62, TASK 801. NO FAULTS. GREEN LIGHT ON.SDR ASAA2016022915695Warning Light · false activationRT PACK CAUTION LIGHT ILLUMINATED ON MASTER CAUTION CHECK AT TOP OF DESCENT. CANCELLED WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED BITE AMM 21-61-00-700-806-002. NO FAULTS FOUND, LIGHT DOES NOT ILLUMINATE DURING MASTER CAUTION CHECK. ACFT OK FOR SERSDR ASAA2016022915694Warning Light · false activationLT PACK LIGHT ILLUMINATES ON RECALL. ACFT GROUNDED IAW FIM 21-62, TASK 848, PZTC BITE NORMAL WITHOUT FAULTS. BOTH PACKS, OPS CHECKED NORMAL ON GROUND.SDR ASAA2016022915693Warning Light · false activationLEFT PACK LIGHT ILLUMINATES DURING MASTER CAUTION RECALL AND RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED PACK/ZONE TEMPERATURE CONTROLLER BITE CHECK ON BOTH PACK ZONE CONTROLLERS IAW AMM TASK 21-61-00-700-806-002. NO FAULTS ON EITHER CONTROLLSDR ASAA2016022815682Blade · missingWHILE OPERATING NR 1 PACK, PACK EMITTED A SIREN LIKE SOUND. ACFT GROUNDED. R & R LT AIR CYCLE MACHINE REF 737-900 AMM 21-51-04-000-802-002 AND AMM 21-51-04-400-802-002. OPS CK, LEAK CK, AND BITE CHECK GOOD.
Back to JASC 2150