JASC 2150
Service difficulty reports · 12,393
Reports filed under 2150 · Cabin Cooling System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR XMXR202104230002Valve · failedECS 1 OFF IN FLIGHT CASSSDR AALA202104089021Spring · brokenAIRCRAFT WAS NOT GROUNDED: PACK FAILURE. 1 PACK LIGHT ILLUMNATED INFLIGHT. RESET OKAY AND THEN LIGHT RE-ILLUMINATED. FLIGHT RETURNED TO FIELD. TROUBLESHOT 1 PACK FAULT , UPON TROUBLESHOOTING FOUND DEFLECTOR DOOR SPRING BROKEN. REMOVED AND REPLACED THE 1 DEFLECSDR UIEA2021040700847Sensor · faultedL PACK TEMP EICAS MSG DISPLAYED AFTER LANDING(<P>PERFORMED FIM 21-51 FAULT TREE 804. IDENTIFIED L MANIFOLD TEMP SENSOR FAULTY. P/N 624016-2 ON ORDER. REMOVED AND REPLACED L MANIFOLD TEMP SENSOR, OPS TEST GOOD.<BR /></P><P>07 APR 21 - LP 1145835 ITEM 6 - TPA - SDR UIEA2021040700848Warning Message · false activationAFT EQ EXH FAN2 STATUS MSG(<P>RESET C/B ON PANEL P11, ROW B, COL 10 IAW 767 AMM 20-60-01-862-001. FAN TEST GOOD IAW AMM 21-26-01-400-002. NO DEFECTS NOTED AT THIS TIME.</P>)SDR P5CA2021040900087A/C Pack · malfunctionedLEFT PACK OFF WOULD NOT RESET(<P>RESET LEFT PACK AND CYCLED APU BLEED SWITCH. OPS CHECK NORMAL IAW AMM21-51-00</P>)SDR UIEA2021040300829Circuit Card · faultedNO EICAS MSG WHEN RT PACK SW OFF(<P>REMOVED AND REPLACED RT PACK FLOW CIRCUIT CARD PER AMM 21-51-09 TASK 401. OPS CKS GOOD AND THIS CLEARS MDDR 144783.</P>)SDR P5CA2021040300082Controller · false activationR PACK TEMP EICAS MESSAGE IN FLIGHT(<P>PERFORMED FIM 21-51 TASK 876, FOUND RT TEMP CONTROLLER AT FAULT. <SPAN>REMOVED & REPLACED</SPAN><SPAN> RT TEMP CONTROLLER PER AMM 21-51-00-405-008-001. OPS CHK OK.</SPAN></P>)SDR UIEA2021040600839Warning Message · false activationAT FL 400 L PACK TEMP EICAS MESSAGE FOLLOWED BY L PACK OFF. ACCOMPLISHED QRH AND RESET PACK. PACK LIGHTS EXTINGUISHED AND CONTINUED IN STBY.(<P>PERFORMED BITE TEST ON L PACK TEMP CONTROLLER BOX 1. NO FAULTS NOTED AND OPS CHECK OF L PACK GOOD IAW B767 AMM 21-5SDR P5CA2021040500084Warning Message · false indicationR PACK TEMP EICAS(<P>RT TEMP. CONT FAIL LIGHT ON. RESET CONT & BITE TEST ACCOMPLISHED IAW AMM 21-51-11. RT PACK OPS CHECK NORMAL.<BR /></P>)SDR P5CA2021040200080Warning Message · false activationRIGHT PACK TEMP EICAS(<P>RIGHT PACK TEMP CONTROLLER FAIL LIGHT ON. RESET CONT. & BITE TEST ACCOMP IAW AMM 21-51-14 - RT PACK OPS CHECK NORMAL.<BR /></P>)SDR UIEA2021040200784Warning Message · false activationAT FL 400 L PACK TEMP EICAS MESSAGE FOLLOWED BY L PACK OFF. ACCOMPLISHED QRH AND RESET PCK. PACK LIGHTS EXTINGUISHED AND CONTINUED IN STBY N.(<P>PERFORMED BITE TEST ON L PACK TEMP CONTROLLER BOX, NO FAULTS NOTED. OPS CHECK OF L PACK GOOD. IAW B767 AMM 21-51-14SDR P5CA2021040100078Warning Message · false activationRIGHT TEMP PACK DURING TAXI(<P>RIGHT PACK TEMP CONTROLLER FAIL LT ON RESET C/OUT AND BITE TEST ACCOMPLISHED IAW AMM 21-51-14 OPERATIONAL TEST SATIS<BR /></P>)SDR ASAA2021033034476Warning Light · false activationL 'PACK' ILLUMINATED ON RECALL. GROUNDED - YES. BITE OF NR 1 CONTROLLER SHOWS TCV FAULT. TEST OF CONTROLLER REF B737-800 AMM 21-61-20-400-801 PASS FAULT CLEARS AND OPS NORMAL.SDR DXTA2021033040270Control Valve · defectiveACM OVERHEAT ON TAKEOFF. THERE WAS A HOT/BURN SMELL IN THE AIRCRAFT. COMPLETED CHECKLIST AND LANDED. DID NOT DECLARE AN EMERGENCY. DID NOT LAND OVER WEIGHT. COMPLIED WITH OPERATIONAL PROCEDURE. REMOVED AND REPLACED RH FLOW CONTROL VALVE. IAW 560XL MM 21SDR ASAA2021032934478Actuator · faultyLEFT PACK LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. RESETS DURING MASTER CAUTION. GROUNDED - YES. ACCOMPLISHED ZONE TEMP CONTROL BITE PER B737-900 FIM 21-62 TASK 801, FOUND RAM AIR ACTUATOR FAULT. ACCOMPLISHED FIM 21-62 TASK 837. REMOVED AND INSTALLSDR VNAA202103291111Acm · failedON TAXI OUT THE CAPTAIN/FO BEGAN TO SMELL A BURNING SMELL THEN GOT A CALL FROM THE FA IN THE BACK SAYING THERE IS SMOKE. THE PAX THEN EVACUATED THROUGH THE MAIN CABIN DOOR ON THE TAXIWAY. THE SMOKE WAS COMING FROM THE CENTER OF THE AIRCRAFT ACCORDING TO THE FASDR GTIA2021032935660A/C Pack · odorFA REPORTED A FUME SMELL AT ROUGHLY 400FT MSL DURING DESENT. PACK 2 WAS TURNED OFF AND SMELL WENT AWAY.-CW TSM 055000810831 FAULT ISOLATION. FAULT ISOLATION TO PACK 2. PACK 2 LOCK OUT. OPS CK OK. NO FUDER ODOR FOUNDSDR UIEA2021032700725Warning Message · false activationL PACK INOP AND L PACK TEMP EICAS DISPLAYED ENROUTE AT CRUISE FL390, STANDBY "N" SELECTED PER QRH, PACK RESET SWITCH PUSHED AND EICAS REMAINED CLEARED WITH STANDBY *N* SELECTED.(<P>PERFORMED FIM TASK 21-51 FT 844. OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2021032700728Valve · faultedAFTER STARTING THE SECOND ENG GOT FWD EQUIP VALVE EICAS, VALVE LIGHT STAYED ILLUMINATED, RETURNED TO PARKING.(<P>TRANSFERRED TO MDDR# 144449, MEL 21-58-08-01-01. PLACARD INSTALLED AND MCC NOTIFIED. CAT C.</P><P>CVG, 28MAR, LP 1334570, ITEM M3: REMOVED AND REPLSDR ASAA2021032734417Warning Light · false indicationDURING MASTER CAUTION RECALL FOR THE DESCENT CHECKLIST, NOTE LEFT PACK LIGHT WAS ILLUMINATED. LIGHT EXTINGUISHED UPON RESET OF THE MASTER CAUTION SYSTEM. GROUNDED - YES. PERFORMED B737-900 FIM 21-62 TASK 801 PACK TEMPERATURE CONTROL BITE PROCEDURE. PERFORMED BSDR YENA2021033100198A/C Pack · odorFLT 165, BOS-RSW. ON TAKE OFF & DECENT AROUND 5K HAD A STRONG SMELL IN THE CABIN. ALMOST LIKE VHEMICAL OF SOME KIND. FA SAID MAYBE DIRTY SOCK SMELL. SEEMS NOW AT GATE APU RUNNING HERE FAINT DIRTY SOCK SMELL. ( APU BLEED VALVE ); REACTIVATED APU AFTER ECS DECONSDR GTIA2021032935657A/C Pack · odorDIRTY SOCK SMELL ON CLIMB OUT OF EWR TURNED PACK 1 OFF SMELL SUBSIDED ON ARRIVAL INTO FLL AT 8000 SMELL RETURNED TURNED PACK 2 OFF SMELL SUBSIDED-PERFORMED PACK # 1 + # 2 BURN OUT WITH APU + ENG 1+2 IAW TSM 05-50-00 AFTER BURN OUT NO ODOR NOTED AT THIS TIMESDR ASAA2021032434392Warning Light · false activationRIGHT HAND PACK LIGHT ILLUMINATED ON RECALL. EXTINGUISHES AFTER MASTER CAUTION RESET. GROUNDED - YES. ACCOMPLISHED RH PACK TEMP CONTROL BITE: LOGGED RAM AIR DOOR "ACTUATOR", FAULT CLEARED. ACCOMPLISHED BITE TWO MORE TIMES, NO FAULTS. REF B737-800 FIM TASK 21-6SDR UIEA2021032100657Sensor · inoperativeCOCKPIT ON EICAS ECS PAGE "L PACK PRIIM HEAT EX IN" SHOWS NO DATA P/N MS 28034-1(<P>REMOVED/REPLACED L PRJ. HEAT EXCHANGER INLET TEMP SENSOR AND OPS CHECK OK AMM 21-52-08.<BR /></P>)SDR MDGA202103270323Cooling Turbine · seizedON CLIMB CREW RECEIVED A DUCT OVERHEAT AND LOSS OF TEMPERATURE CONTROL. EMERGENCY PRESSURIZATION SYSTEM ACTIVATED AND CAUSED NOXIOUS ODOR IN THE CABIN. THE CREW HANDLED USING CHECKLIST AND LANDED WITHOUT FURTHER INCIDENT AT DESTINATION AIRPORT. MAINTENANCE IDESDR P5CA2021032200073Warning Message · false indicationEICAS MESSAGE R PACK TEMP(<P>PER AMM 21-51-00, PERFORMED R PACK TEMP CONTROLLER BITE TEST. PASSED. MSG GONE.</P>)SDR AALA202103219004Ecs · contaminatedAIRCRAFT WAS GROUNDED: SMELLED DIRTY SOCKS ODOR AFTER TAKE OFF ABOUT 20,000 FEET WITH ENGINE ANTI ICE ON. DISSIPATED WHEN ENGINE ANTI ICE OFF. ODOR RETURNED ON DESCENT WITH ANTI ICE OFF FROM 10,000 FEET UNTIL ARRIVAL AT GATE. TURNED RIGHT PACK OFF AND NO CHANGSDR P5CA2021032200074Warning Message · false activationR PACK TEMP CAUTION APPEARED ON APPROACH WHEN PASSING THROUGH 10,000 / FEET. EMERGENCY PROCEDURE ACCOMPLISHED(<P>R PACK CONTROLLER BITE CHECKED "CONTROLLER FAULT" AND RECYCLED PACK TEMP CONT RELATED CBS THEN NO FAULT FOUND. R PACK SYS OPS NORMAL PER AMM 21-51SDR UIEA2021031500562Relay · malfunctionedBTB ON PUSHBACK AFTER ENG START FWD EQUP VLV EICAS MSG. RAN QRH LIGHT DID NOT EXT.(<P>TRANSFERRED TO DMI 143825 IAW MEL 21-58-07 PROCEDURE 2. PLACARDS INSTALLED. MCC NOTIFIED. </P><P>LP 1329081: PERFORMED FIM 21-58-58 FT 939. REMOVED AND REPLACED OVERBOARD EXHSDR ASAA2021031434284Control Valve · failedLEFT PACK FLOW CONTROL VALVE CLOSED POSITION SWITCH FAILED. FMC RECEIVES "OPEN" DISCRETE FROM TARGET CALCULATIONS. GROUNDED - YES. REMOVED AND REPLACED LEFT PACK FLOW CONTROL VALVE REF AMM 21-51-01, LEAK AND OPS CK'S GOOD.SDR UIEA2021031300537Check Valve · stuckL PACK TEMP. CLEARED AFTER QRH, LEFT IN N POSITION PER PROCEDURE. PERFORMED PACK TEMPATURE CONTROLLER BITE TEST IAW AMM 21-51-14. BITE TEST GOOD. PERFORMED OPS CHECK OF COOLING PACK IAW AMM 21-51-00, OPS CHECK GOOD NO DEFECTS NOTED AT THIS TIME. DUE TO HISTOSDR ASAA2021031334283Control Valve · faultedRIGHT PACK LIGHT ILLUMINATED ON RECALL. EXTINGUISHES ON RESET. GROUNDED - YES. PERFORMED BITE CHECK OF RIGHT HAND PACK/ZONE TEMP CONTROLLER. INITIAL BITE TEST SHOWED TCV FAULT, ABLE TO RESET, BITE TEST OPS NORMAL, REF B737-800 AMM 21-61-00.SDR AALA202103139005Sensor · faultyAIRCRAFT WAS GROUNDED: FLIGHT DIVERTED TO LAS FOR LH PACK FAILURE. REPLACED PRECOOLER SENSOR 390 AND PRECOOLER VALVE (AALA202103139004) IAW AMM 36-12-03, AMM 36-12-01, AND JOB CARD JC08L40036001, OPS CHECK GOOD.SDR AALA202103139004Valve · faultedAIRCRAFT WAS GROUNDED: FLIGHT DIVERTED TO LAS FOR LH PACK FAILURE. REPLACED PRECOOLER VALVE AND PRECOOLER SENSOR 390 (AALA202103139005) PER AMM 36-12-03, AMM 36-12-01, AND JOB CARD JC08L40036001, OPS CHECK GOOD.SDR HYIA20211310001Heater · odorTHE PILOT REPORTED A BURNING SMELL IN THE CABIN IN FLIGHT WITH THE HEATER TURNED ON. MAINTENANCE INSPECTED AND REPLACED THE HEATER ASSEMBLY WITH NO FURTHER DEFECTS NOTED.SDR ASAA2021030834258Warning Light · false activationRT PACK LIGHT ILLUMINATED DURING CLIMB OUT ABOUT 24K FEET. RAN CHECK LIST LIGHT STAYED ILLUMINATED. RETURNED TO SEATTLE PER DISPATCH. GROUNDED - YES. DIVERSION TIME 35 MINUTES - ACCOMP WIRING CHECKS PER TSR 710605 STEP 1 NO DISCREPANCIES, STEP 2 NO DISCREPANCISDR UIEA2021031000510A/C Pack · malfunctionedLEFT PACK INOP AND LEFT PACK TEMP EICAS MSG(<P>PERFORMED PACK RESET AND BITE CHECK IAW FIM 21-51-803. NO FAULTS NOTED. OPS CHECK GOOD.</P>)SDR HNAA2021030800094Unknown · odorPDIS 683 21-01 2532571 08MAR21 FLO ASSGN
PACK 2 OVERHEAT WITH BURNING SMELL IN COCKPIT AND TR
OUBLE COOLING A/C. BURNING SMELL ALSO NOTICED WITH O
NLY PACK 1 RUNNING (NOTE: CREW STATED IT TAKES RUN
NING 3 MINS BEFORE SMESDR AALA202103099006Condenser · odorAIRCRAFT WAS GROUNDED: ON TAKE-OFF, SMELL OF FUMES IN COCKPIT AND CABIN APU WAS OFF. SMELLED LIKE DEICE/BURNT OIL. RETURNED TO PHL. PERFORMED J/C'S 26L00021001, 26L00021003, 26L00021004. SUCCESSFUL DECONTAMINATION ACCOMPLISHED, LEFT PACK. REPLACED CONDENSER (ASDR IPXA2021030766499A/C Pack · odorINSPECTION TYPE:N/ASLIGHT OILY SMELL COMING FROM THE PACKS. MORE PRONOUNCED WITH THE LEFT PACK ON. AT ALTITUDE OIL PRESSURE LEFT ENGINE 51, RIGHT ENGINE 91.R+R LEFT ENGINE IAW TC #5001 (RR) OPS AND LEAK CKED GOOD. A/C OK FOR SERVICE.SDR ASAA2021030434246Control Valve · faultedRIGHT PACK LIGHT ILLUMINATED. GROUNDED - YES. PERFORMED BIT PER B737-800 FIM 21-62 TASK 801. INITIALLY NO FAULTS NOTED. NOTED TCV FAULT ON LATER BIT CHECK. TCV FAULT CLEARED PACK OPERATED NORMALLY AT THAT TIME. SUSPECT FAULTY RH TCV. REMOVED AND REPLACED #2 PASDR UIEA2021030400473Control Valve · malfunctionedLEFT PACK INOP IN AUTO ( PACK TEMPERATURE CONTROL SYSTEMS (-200/-300) , AUTO MODE )(<P>TRANSFER TO DMI 143251 IAW MEL 21-51-03-01, CAT C, DUE DATE 13MAR21. </P><P>ACCOMPLISHED ACTION PLAN 19320 PER MCS 8001 REV 0. REMOVED AND REPLACED ACM TEMP CONTROL VALVE PESDR UIEA2021030400474Warning Message · false activationL PACK TEMP EICAS. QRH COMPLETE, FAULT REMAINS. RAN FAULT TREE FIM 21-51 TREE 844. NO FAULTS FOUND. OPS CKS GOOD.SDR SWAA2021030453003Acm · odorFAINT ELECTRICAL SMELL NOTED BY BOTH PILOTS; DISSAPPERED IMMEDIATELY. NO SMOKE NOTED. EXPERIENCED LEFT PACK TRIP OFF ON LANDING. / PERFORMED CONDITIONAL INSPECTION PER AMM 05-51-56 FOUND LEFT ACM AND LEFT TEMP CONTROL VALVE TO BE BAD. R/RD LEFT ACM PER AMM 21-SDR UIEA2021030300471Actuator · failedL PACK TEMP EICAS MSG REMOVED AND REPLACED;LH PACK INLET DOOR ACTUATOR IAW B767 AMM 21-53-03. OPS CHECK/ BITE TEST GOOD IAW 767 AMM 32-09-02. REMOVED AND REPLACED LH PACK LOW LIMIT VALVE IAW AMM 21-51-11 PN: 3289696-1 SN: 3182. OPS AND LEAK CHECKS GOOD.SDR I5PA2021030192202Control Valve · inoperativeRIGHT PACK FLOW CONTROL VALVE WAS FOUND FAULTY DURING THE PACK OPERATIONAL CHECK. PART WAS REPLACED AND PACK WAS PLACED BACK IN OPERATION.SDR I5PA2021030192201Circuit Card · faultedRIGHT PACK RESET SWITCH WAS PLACED ON MEL. ISSUE WAS ISOLATED TO A FAULTY PACK FLOW CONTROL CARD.SDR ASAA2021030134215Control Valve · failedRIGHT PACK LIGHT ILLUMINATED. GROUNDED - YES. DURING CONTROLLER BITE TEST TCV SHOWED FAILED. REMOVED AND REPLACED RH TEMP CONTROL VALVE PER B737-800 AMM 21-51-10-400-801. OPS AND LEAK TEST GOOD.SDR HNAA2021030100065A/C Pack · failedPDIS 644 21-51 2139501 28FEB21 TRI ASSGN #1 PACK FAIL WITH BURNING SMELL MEL 28FEB21 10:56 TRI C05904 21-13-1 1 AIR CON PACK ELECTRO/MECH N600-N649 SMOKE REPORT HAS BEEN FILLED OUT, SDR SUPPLEMENTAL INFO WILL FOLLOW, CURSDR UIEA2021022700425Plenum · damagedAPPROX 50 MIN INTO FLIGHT, SLIGHT VIBRATION FELT IN AIRFRAME. VIBRATION FELT EVERY 5 TO 6 MINS. LASTING APPROX.15 SECONDS. NO EICAS OR STATUS MESSAGES ASSCOCIATED. NO HIGH VIB INDICATION ON ENGINE. THE OUTFLOW VALVE APPEARS TO BE MOVING AND SEEMS TO COINCIDE W