SDR ASAA2018071625440Modulating Valve · failedON TAXI OUT FWD ZONE TEMP ILLUM ON RECALL. GROUNDED - YES. R&R V0144 TRIM MODULATING VALVE. CHECKED GOOD. NO MORE FAULT. OPS NORMAL REF AMM 21-61-21 /401.SDR UIEA2018071701498Warning System · false activationFWD CARGO BACKUP ADVISORY MESSAGE. PERFORMED FIM TASK 21-61 FT 803 BITE PROCEDURES. COULD NOT DUPLICATE DISCREPANCY. AIRCRAFT OK FOR SERVICE.SDR ASAA2018071525467Modulating Valve · failedAFTER ENGINE START AND PACKS WERE PLACED ON, "ZONE TEMP" LIGHT ILLUMINATED ON FORWARD CAB. BOTH MASTER CAUTION LIGHTS ILLUMINATED ALONG WITH AIR CONDITIONING LIGHT. LIGHTS WOULD NOT RESET WHEN MASTER CAUTION PRESSED. FWD CAB TEMP CONTROLLER KNOB HAD NO EFFECT SDR IPXA2018071831738Indicator · defectiveINSPECTION TYPE:MX, FLIGHT DECK TRIM AIR VALVE POSITION INDICATOR INOP, TEMP CONTROL NORMAL. R&R FLIGHT DECK TRIM AIR VLV INDICATOR ASSY IAW AMM 21-64-01.SDR ASAA2018071625394Unknown · malfunctionedTEMPERATURE CONTROL INCONSISTENT THROUGHOUT PASSENGER CABIN. TYPICALLY VERY WARM IN ROWS 6-10 WHEN REST OF CABIN COMFORTABLE. IF 6-10 ARE COMFORTABLE, OTHER PASSENGERS COMPLAIN OF BEING TOO COLD. GROUNDED - YES. COMPLETED PACK/ZONE TEMP CONTROL BITE CHECK NO FSDR ASAA2018071625343Unknown · malfunctionedZONE TEMP CONT CAB ON RECALL. CLEARS WITH M/C RESET. GROUNDED - YES. PERFORMED PACK TEMP CONTROL BITE REF FI 21-62 TASK 801. NO FAULTS FOUND ZONE TEMP REMAINS EXTINGUISHED WITH RECALL.SDR ASAA2018070925321Warning System · false activationZONE TEMP (CONT CAB) ILLUMINATED UPON RECALL, EXTINGUISHES WHEN MASTER CAUTION SYSTEM IS RESET. GROUNDED - YES. NR 2 CONTROLLER LOGGED FLT DECK TRIM VALVE FAULT. RESET FAULT. COMPLETED FIM 21-62 TASK 801, PACK TEMP CONTROL BITE. NO FAULTS, OK FOR SERVICE.SDR YADA20180703001Warning System · activatedPILOT REPORTED AIRCRAFT HAD A RIGHT HAND ENVIRONMENTAL FAIL INDICATION AND PERFORMED UNSCHEDULED LANDING AT HOME STATION. MAINTENANCE IS CURRENTLY TROUBLESHOOTING.SDR ASAA2018062625218Warning System · false activationFWD CAB ZONE TEMP ILLUMINATED ON RECALL. RESETS AS WELL. GROUNDED - YES. FAULT CODE 21622100 FIM 21-62 TASK 843. INITIAL INSPECTION NO FWD CAB ZONE LIGHT ON RECALL. NO FAULT LOGGED ON EITHER TEMP CONTROLLER. PERFORMED PACK TEMP CONTROL BITE TEST REF FIM 21-62 SDR ASAA2018062425197Unknown · malfunctionedFA REPORTS IN FLIGHT AFT CABIN IS VERY COLD EVEN WITH THE AFT CABIN CONTROL TURNED TO WARM AND INDICATES WARM AIR IN THE DUCT. ON THE GROUND APU RUNNING AND AFT CABIN CONTROLLER ON FULL WARM FA STILL REPORTS THE AIR IS LUKE WARM AT BEST. GROUNDED - YES. TEMP CSDR ASAA2018062025138Valve · faultedCONTROL CABINE ZONE TEMP LIGHT ILLUMINATED ON RECALL, CLEARS WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED PZTC BITE ON BOTH CONTROLLERS IAW FIM 21-62, TASK 801. ON NR 2 CONTROLLER, FOUND FLT DECK TRIM VALVE FAULT FOR PREVIOUS FLIGHT. RESET SUCCESSDR ASAA2018062195137Valve · faultedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON MASTER CAUTION RECALL. ACFT GROUNDED. ACCOMPLISHED CONTROLLER BITE IAW 21-61-00-700-806-002. FOUND FLT DECK TRIM VALVE FAULTED. RESET SUCCESSFUL. OPS GOOD IAW AMM 21-01-00-700-807-002. NO HISTORY LAST 90 DAYS.SDR CALA2018062211494Controller · malfunctionedTEMPERATURE CONTROL CANNOT COOL THE CABIN. ALL TEMPERATURE SELECTORS SET TO FULL COLD, A/C WOULD NOT COOL DOWN ON THE GROUND. TEMP WAS REACHING A SAFETY CONCERN. OPEN.SDR ASAA2018061855067Warning Light · false activationZONE TEMP CONTROL CABIN LIGHT ILLUMINATED ON RECALL. EXTINGUISHED ON MC RESET. ACFT GROUNDED. PERFORMED A PACK TEMP CONTROL BITE IAW FIM 21-62, TASK 801. NO FAULTS FOUND. LIGHT REMAINS EXTINGUISHED ON RECALL. NO 90 DAY HISTORY.SDR ASAA2018061184990Controller · false indicationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXTINGUISHED WHEN RESET. ACFT GROUNDED. VERIFIED CONT CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL. ACCOMPLISHED FIM 21-62J,TASK 801. CLEARED FAULT FROM THE NR 2 CONTROLLER FLT DECK TRIM VALVE. LIGHT NO LSDR ASAA2018060864959Warning Light · false activationCONTROL CABIN ZONE TEMP ILLUMINATED. ON RECALL, DID NOT RESET. ACFT GROUNDED. ACCOMPLISHED A PACK/ZONE TEMPERATURE CONTROLLER BITE TEST, OPS NORMAL IAW AMM 21-61-00-700-806-002.SDR ASAA2018060524923Valve · malfunctionedHOT AIR A/C VALVE STUCK IN CLOSED POSITION GROUNDED - YES. PERFORMED BITE TEST OF ACSC SYSTEM OPS CK GOOD, HOT AIR VALVE CLOSED AND OPEN OK, REF AMM 21-61-00-00,SDR ASAA2018060624887Valve · failedON RECALL, THE CONTROL CABIN ZONE TEMP ILLUMINATED, EXTINGUISHED ON RESET. ACFT GROUNDED. REMOVED & REPLACED THE ZONE TRIM MODULATION VALVE IAW AMM 21-61-21-000/400. CHECKED GOOD IAW AMM 21-51-00-700-803, PACK ZONE TEMP CONTROLLER BITE TEST. OPS NORMAL.SDR ASAA2018060694853Valve · faultedAFTER TAKEOFF, OBSERVED THE CONTROL CABIN ZONE TEMP LIGHT WAS ILLUMINATED. FOLLOWED THE QRH AND THE ZONE TEMP EXTINGUISHED WHEN THE MASTER CAUTION SYSTEM WAS RESET. THE TEMPERATURE CONTROLLER WORKED NORMALLY. ACFT GROUNDED. PERFORMED PACK ZONE CONTROL BITESDR UIEA2018052900998Controller · defectiveAFT CABIN TEMP WAS INOPERATIVE. PERFORMED A BITE TEST OF THE ZONE TEMP CONTROLLER FAULT TRIM VALVE, FOUND AFT ZONE TEMP VALVE MOTOR CIRCUIT BREAKER TRIPPED. REMOVED AND REPLACED ZONE TEMP TRIM AIR VALVE. OPS CHECKED GOOD IAW AMM 21-61-01. FOUND THE ZONE TEMSDR ASAA2018052974814Warning Message · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, GOES OUT WITH PUSH TO RESET. ACFT GROUNDED. RESET TEMP VALVE FAULT. ACCOMPLISHED A PACK - ZONE TEMP CONTROL BITE TEST IAW AMM 21-61-00. NO CURRENT FAULTS NOTED. NO HISTORY 30 DAYS.SDR ASAA2018052524808Warning System · false activationON AFTER START CHECKS AIR COND LIGHT ILLUMINATED WITH CONT CABIN TEMP ZONE ON MASTER CAUTION RECALL AND RESETS ON SUBSEQUENT RECALL. GROUNDED - YES. PERFORMED BITE FOR BOTH PACK TEMP CONTROLLERS, REF FIM 21-62 TASK 801, BOTH CONTROLLERS TEST PASSED, NO FAULTS SDR ASAA2018052224744Warning System · false activationWHEN RECALL FOR MASTER CAUTION SYSTEM IS PRESSED, AIR COND IS ILLUMINATED WITH A ZONE TEMP LIGHT FOR THE FWD CAB. LIGHTS EXTINGUISH WHEN MASTER CAUTION SYSTEM IS RESET. GROUNDED - YES. FWD CAB ZONE TEMP OPS CHECK GOOD IAW FIM 21-62 TASK 843.SDR ASAA2018052124743Warning System · false activationON DESCENT CHECK, RECALL ILLUMINATED CONT ZONE TEMP CAUTION LIGHT, LIGHT EXTINGUISHED WITH MASTER CAUTION RESET. GROUNDED - YES. RELEASED PER MEL 21-21F, CONT CABIN ZONE TEMP INOP. ACCOMPLISHED PACK FLOW TEMP CONTROLLER BITE TEST PER AMM TASK 21-61-00 AND TCV SDR ASAA201805224725Ecs · malfunctionedFA REPORTED WERE UNABLE TO COOL ROWS 6 - 16 INFLIGHT, UNTIL THE LAST HOUR OF FLIGHT. ACFT GROUNDED. NO HISTORY LAST 60 DAYS. PFTC FAULT HISTORY LAST LEG SHOW R: 21-51123, L: 21-51123 & 21-51117. ALL FAULTS SHOW AS INTERMITTENT, COUNT 1 & FAULT STATE. RECSDR ASAA201805224724Shutoff Valve · faultedDURING DESCENT, PRESSING MASTER CAUTION RECALL, FWD CABIN ZONE TEMP ILLUMINATED. PRESSING MASTER CAUTION RESET, THE LIGHT EXTINGUISHED. ACFT GROUNDED. THIS TIME THE OPS PROCEDURE TO DISPATCH. #2 PZTC BITE SHOWS CABIN SENSOR - ZONE FAULT AND NR 1 PZTC SHOWS SDR ASAA2018052194694Accessory Unit · malfunctionedFWD ZONE CABIN TEMP LIGHT ILLUMINATED, TEMP NORMAL. ACFT GROUNDED. PERFORMED TROUBLESHOOTING IAW FIM 21-62 TASK 840, AND 21-62 TASK 839. AGAIN ZONE TEMP CONTROLLER 2 FAILED ZONE CABIN SENSOR DURING BITE CHECK. THIS SENSOR HAS BEEN REPLACED. FAULT CLEARED OSDR ASAA201805214691Warning Light · false activationCONTROL CABIN ZONE TEMP ILLUMINATED ON RECALL AFTER START. THE CONTROL CABIN ZONE TEMP LIGHT GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED A PACK TEMP CONTROL BITE, FOUND NO FAULTS. LIGHT DOESN'T ILLUMINATE ON RECALL IAW FIM 21-62, TASK 801.SDR JIKA201805221801Actuator Valve · brokenTHE PILOT REPORTED THAT WHILE CLIMBING, THAT THE COCKPIT WAS VERY HOT. AFTER TURNING THE TEMPERATURE CONTROLLER FROM AUTO TO MANUAL COLD, THE COCKPIT BECAME HAZY. A SHORT TIME LATER THE SMOKE STARTED TO CLEAR. THE PILOT ADVISED ATC, RETURN TO DEPARTURE AND LANSDR ASAA201805214674Sensor · dirtyDURING THE DESCENT CHECKLIST, WHEN RECALL WAS PUSHED, RECEIVED A FWD CABIN ZONE TEMP LIGHT, EXTINGUISHED ON RESET. ACFT GROUNDED. PERFORMED A BITE CHECK OF THE ZONE TEMP CONTROLLER NR 2, M1143. BITE AND PREVIOUS FLT FAULTED ZONE CABIN SENSOR FAULT, TROUBLSDR ASAA2018051624662Filter · cloggedFWD CABIN ZONE TEMP LIGHT ILLUMINATED WITH RECALL, EXTINGUISHED WHEN MASTER CAUTION RESET. ACFT GROUNDED. RESET WITH MASTER CAUTION. ACCOMPLISHED CABIN TEMP CONTROLLER BITE IAW FIM 21-62 TASK 801. FOUND THE FWD SENSOR FAULT LOGGED. FOUND ALL CABIN AND FLISDR ASAA201805174661Warning Light · false activationCONTROL CABIN ZONE TEMP ILLUMINATED DURING AFTER START FLOW. ACFT GROUNDED. PERFORMED FIM 21-62 TASK 842, CONT CABIN ZONE TEMP LIGHT ILLUMINATED, FAULT RESET NO OTHER FAULTS NOTED NO HISTORY IN THE PAST 30 DAYS.SDR ASAA201805164641Valve · malfunctionedFLT DECK ZONE TEMP ILLUMINATED ON MASTER CAUTION RECALL. ACFT GROUNDED. FLT DECK TRIM VALVE FAULT NR 2 ZONE TEMP CONTROLLER, RESET & TESTS NORMAL IAW FIM 21-62 TASK 832. ETOPS SIGNIFICANT SYSTEM, GROUND VERIFICATION SUCCESSFUL.SDR ASAA201805164640Unknown · unknownPASSENGER CABIN EXCESSIVELY HOT WITH CABIN CONTROL KNOBS TURNED TO FULL COLD. ACFT GROUNDED. PERFORMED CABIN TEMPERATURE CONTROL AND INDICATION OPERATIONAL TEST WITH LT, RT, AND BOTH PACKS WITH NO DEFECTES NOTED IAW AMM 21-61-00-700-807-002. ETOPS GROUND VSDR ASAA201805164639Warning Light · false activationPASSENGER CABIN TEMP EXCESSIVELY HOT. AIR TEMP CONTROL PANEL HAD FOLLOWING INDICATIONS DURING CRUISE FLIGHT. SUPPLY CONT CAB 5 FWD 4 AFT 4PASS CAB FWD 30, AFT 32 PACK : R 30 L 25. ACFT GROUNDED. COMPLIED WITH A LT PACK ZONE TEMP CONTROLLER BITE TEST IAW AMM SDR ASAA2018051324618Warning System · false activationFWD CABIN ZONE TEMP ILLUMINATES WITH MASTER CAUTION RECALL. EXTINGUISHES WITH MASTER CAUTION RESET. GROUNDED - YES. REVERSED CONFIGURATION CHANGES OF MEL 21-1G OF THE RT PACK REF AMM 21-00-00-040-804. PERFORMED PZTC BITE ON BOTH CONTROLLERS, MULTIPLE TIMES WITSDR ASAA201805144589Filter · warning lightCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. CLEARED THE TEMP SENSOR FILTER IAW AMM 21-61-06-100-801. OPS CHECKED IAW AMM 21-61-00. ZONE TEMP LIGHT EXTINGUISHED ON RECALL.SDR ASAA2018062824479Fault Message · false activationHOT AIR FAULT. ACFT GROUNDED. PERFORMED AN OPS CHECK OF THE COCKPIT AND CABIN TEMP CONTROL IAW AMM 21-63-00. OPS CHECKED GOOD. NO DEFECTS NOTED.SDR UIEA2018050100825Valve · inoperativeZONE TRIM AIR MODULATING VALVE GAUGE FLUCTUATES ERRATICALLY EVERY TIME VALVE MOVES. OPS CHECKED THE A/C PACKS IAW AMM 21-61-00. FOUND ZONE TRIM VALVE TO BE INOPERATIVE.SDR UIEA2018050100824Gauge · erraticCOLD WARM GAUGE FOR TEMP CONTROL FLUCTUATES ERRADICALLY. PERFORMED AN OPS CHECK OF THE PACKS. OPS CHECKS GOOD IAW AMM 21-61-00.SDR ASAA2018050124415Warning Light · false activationON RECALL, CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. CLEARED WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED A PACK TEMP CONTROL BITE IAW FIM 21-62 TASK 801, NO DISCREPANCIES NOTED WITH ALL FAULTS CLEARED.SDR ASAA2018042824416Indicator · failedWHEN USING THE CABIN, DUCT TEMP SELECTOR KNOB, ABNORMAL TEMPS IN THE CABIN WILL INDICATE ON NEEDLE ON GATE. ALSO TEMP NEEDLE WILL VARY WIDELY WHEN SELECTING CABIN TEMPS AND DUCT TEMPS. ACFT GROUNDED. REPLACED THE TEMP INDICATOR IAW AMM 21-61-00-700-807-002.SDR ASAA201804304417Control Valve · faultedZONE TEMP ANNUNCIATED AFTER ENGINE START ON COCKPIT TEMP CONTROL. ACFT GROUNDED. CONFIRMED FAULT, THE NR 2 PACK, ZONE TEMP CONTROLLER SHOWS FLIGHT DECK TCV V143 FAULTED. REMOVED & REPLACED THE COCKPIT TCV IAW AMM 21-61-21, LEAK & OPS CHECKED NORMAL IAW AMM SDR ASAA2018042724414Warning Light · false activationDURING MASTER CAUTION RECALL, CONTROL CABIN ZONE TEMP AMBER LIGHT ILLUMINATED. ACFT GROUNDED. PERFORMED FIM 21-62-00-810-801, PACK TEMPERATURE CONTROL-BITE PROCEDURE, ALL TESTS PASSED.SDR ASAA2018042704396Control Valve · faultedRIGHT PRIMARY TEMP CONTOLLER INOPERATIVE ILLUMINATED. LIGHT EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED A TEMP CONTROLLER BITE CHECK, FOUND THE TEMP CONTROL VALVE FAULTED. REMOVED & REPLACED THE TEMP CONTROL VALVE IAW AMM 21-51-10. LEASDR ASAA2018042424377Filter · dirtyON RECALL, FWD CABIN ZONE TEMP ILLUMINATED, EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED THE LT & RT CONTROLLER BITE IAW AMM 21-61-00. FOUND THE NR 2 CONTROLLER LOGGED FWD ZONE. CLEANED THE FWD AND AFT FILTERS. GROUND RAN PACK FOR SDR FDEA201804221092Controller · failedAFTER LEVEL OFF, HAD NO FWD CABIN TEMP CONTROL. RECEIVED A CABIN TEMP ICAS. TROUBLESHOT IAW MOCC. RETURNED TO DEPARTURE. SYSTEM CONFIGURATION OF CH 21 CTC SHOWED MISSING INFO FOR LT CTC CHANNELS 1 & 2. R & R THE LT CTC IAW AMM 21-61-01. CHECKED GOOD. OK SDR ASAA2018042224352Warning Light · false activationAFTER START, WHEN PRESSING MASTER CAUTION RECALL FWD CABIN ZONE TEMP ILLUMINATED. ZONE TEMP LIGHT EXTINGUISH WITH MASTER CAUTION WHEN VERIFYING PACK CONTROL, SUPPLY DUCT TEMP DID NOT MOVE. ACFT GROUNDED. ACCOMPLISHED A PACK TEMP CONTROL BITE IAW FIM 21-62 TASDR O9IA201804190001Sensor · damagedDURING CRUISE FLIGHT, PILOT NOTED AN FAINT ELECTRICAL SMOKE ODOR. DETECTED IN THE CABIN AS WELL. TURNED BACK TO BASE. THE CREW IN THE BACK TRACED THE ODOR TO THE OVERHEAD PANEL THAT HOUSES THE AUTO TEMP SENSOR. THE PILOT THEN TURNED OFF THE AUTO TEMP MODE SDR P5CA2018041800064Relay · failedFLT DECK TEMP CONTROL INOPERATIVE IN AUTO, CYCLED FROM FULL HOT TO FULL COLD. EICAS ACTIVATED FOR A FEW MINUTES. R & R THE FLIGHT DECK ZONE DUCT OVERHEAT RELAY K238 IAW AMM 21-61-00. OPS CHECKED NORMAL IAW SWPM 20-81-13, AND AMM 21-61-00.
Back to JASC 2160