SDR ASAA2016091318002Warning Light · false activationZONE TEMP LIGHT ON CONTROLLER CABIN. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST. CLEARED FAULT, ZONE TEMP LIGHT NO LONGER ILLUMINATED IAW FIM 21-62, TASK 801.SDR ASAA2016091117982Control System · malfunctionedAFTER START OBSERVED ZONE TEMP FOR CONTROL CABIN AND AFT CABIN ILLUMINATED. THE AFT SUPPLY DUCT FAILED TO RESPOND TO TEMP SELECTOR MOVEMENT TO HOT OR COLD. ACFT GROUNDED. RECYCLED AIRCRAFT POWER IAW AMM 24-00-00. CHECK NORMAL. AIRCRAFT OK FOR SERVICE.SDR ASAA2016091117981Filter · dirtyCOCKPIT ZONE TEMP LIGHT ILLUMINATES ON RECALL. CLEARS ON RESET. ACFT GROUNDED. PERFORMED BITE OF PACK/ZONE TEMP CONTROLLERS, NO FAULTS, IAW AMM 21-61-00. CLEANED CABIN TEMP SENSOR FILTERS, IAW AMM 21-61-06.SDR ASAA2016090817969Modulating Valve · failedFWD CAB ZONE TEMP LIGHT ILLUMINATED AFTER TAKEOFF. CONTROLLER SEEMS TO BE WORKING BUT RESET DID NOT EXTINGUISH THE LIGHT. LATER IN FLIGHT M/C RESET EXTINGUISHED LIGHT. ACFT GROUNDED. FOUND NR 2 CONTROLLER HAS ZONE TRIM VALVE FAULT LIGHT. ACCOMPLISHED BITESDR ASAA2016090417891Warning Light · false activationCONTROLO CAB ZONE TEMP ILLUMINATED ON RECALL RESETS WITH M/C. ACFT GROUNDEDS. NO CURRENT FAULT ON RECALL. PACK/ZONE CONTROLLERS IAW AMM 21-61-00-700-806-002 BITE CHECKED OK. NO CURRENT FAULTS. NO HISTORY 60 DAYS. ETOPS GROUND VERIFICATION COMPLETE. RAN BOTHSDR ASAA2016090317895Valve · malfunctionedDURING LIFTOFF, COCKPIT BECAME VERY WARM. ALSO, NOT THE SAME VOLUME OF AIR COMING OUT OF VENTS. DURING CLIMB, PRESSURIZATION OK. AIR VOLUME CONTROL RETURNED TO NORMAL AND SYSTEM PERFORMED NORMALLY. ACFT GROUNDED. CURRENTLY SYSTEM CHECKS GOOD BUT HAS HISTORY.SDR ASAA2016090317893Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON MASTER RECALL. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROLLER BITE TEST IAW AMM 21-21-00-700-806-002. LEFT CONTROLLER SHOWED TCV FAULT IN FLT HISTORY. ON BITE VERIFICATION, THE CONTROLLER RESET WITH NO FURTHER OCSDR ASAA2016090217894Warning Light · false activationCONTROL CABIN ZONE TEMP ILLUMINATED ON RECALL. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROLLER BITE TEST IAW AMM 21-61-00-700-806-002. LEFT CONTROLLER SHOWED TCV FAULT IN FLT HISTORY. UPON BITE VERIFICATION, THE CONTROLLER RESET WITH NO FURTHER SDR ASAA2016083117872Fan · obstructedON AIR TEMP CONTROLLER PANEL, FORWARD CABIN WAS VERY ERRATIC. TEMPERATURE WAS CONTROLLER BUT WOULD HAVE SEVERE TEMPERATURE SWINGS WITH VERY LITTLE MOVEMENT POSITION OF CONTROL KNOB. TEMP WAS ALMOST UNBEARABLE ACCORDING TO FAS, TOO HOT. CONTROLLER TO "OFF" ASDR ASAA2016083017857Sensor · contaminatedON TAXI UPON RECALL " FWD ZONE TEMP" LIGHT ILLUMINATED AND CANCELS ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE CHECK. NR 1 CONTROLLER OPS NORMAL, NO FAULTS NOTED. NR 2 CONTROLLER HAD 1 FAULT (ZONE). CHECKED AND FOUNDSDR ASAA2016082917841Controller · malfunctionedFLIGHT DECK ZONE TEMP LIGHT ILLUMINATES ON RECALL, EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. NR 2 ZONE TEMP CONTROLLER LOGGED FLIGHT DECK TRIM VALVE FAULT. RESET FAULT. ACCOMPLISHED ZONE TEMP CONTROLLER BITE IAW AMM 21-61-00,TEST PASSED.SDR ASAA2016082117767Controller · faultedLEFT A/C PACK ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROL BITE IAW FIM 21-62 TASK 801. FLIGHT DECK TRIM VALVE FAULT, NR 1 CONTROLLER. CLEARED FAULT. RAN PACKS AND FAULT REMAINED CLEARED.SDR ASAA2016082017752Modulating Valve · failedCONTROL CAB ZONE TEMP ILLUMINATED AFTER RECALL, EXTINGUISHES WITH RECALL. ACFT GROUNDED. PERFORMED NR 2 PACK ZONE TEMP CONTROL BITE, REF FIM 21-62, TASK 801. FOUND CONTROL CABIN TRIM AIR VALVE FAULT IN CURRENT, HISTORY, AND VERIFY. R & R CONTROL CABIN TRIMSDR COZA20160820090Valve · intermittentCONTROL CABIN AMBER ZONE TEMPERATURE ANNUNCIATOR ILLUMINATED ON RECALL. BITE CHECK OF THE ZONE/TEMPERATURE CONTROLLER INDICATED A FAILED CONTROL CABIN TRIM AIR VALVE. REPLACED THE CONTROL CABIN TRIM AIR VALVE AND OPERATIONAL CHECK NORMAL.SDR ASAA2016081717735Control Valve · failedAFTER ENGINE START, LEFT PACK LIGHT ILLUMINATED, EXTINGUISHED WITH MASTER CAUTION. ACFT GROUNDED. PERFORMED PACK TEMP CONTROLLER BITE TEST IAW AMM 21-51-00-700-80. LT PACK LOGGED "TCV" FAULT. REMOVED & REPLACED THE LT TEMP CONTROL VALVE IAW AMM 21-51-10/40SDR ASAA2016081517708Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. NR 2 ZONE TEMP CONTROLLER SHOWS FLIGHT DECK SELECTOR ON PREVIOUS FLIGHT, GREEN FOR BITE & VERIFY, FAULT CLEARED. RAN PACKS & RE-VERIFY BITE, IAW FIM 21-62 TASK 801, GROUND VERIFICATION TEST SDR P5CA2016081500196Controller · malfunctionedCOCKPIT AUTO TEMPERATURE CONTROL INOPERATIVE. CHECKED FLT DECK SENSOR FILTER, NORMAL CONDITION. ZONE TEMP CONTROLLER CONDITION NORMAL IAW AMM 21-61-03 AND FIM TASK 21-61.SDR P5CA2016081200193Filter · dirtyFLIGHT DECK AUTO TEMP CONTROL FAILS TO MAINTAIN DESIRED TEMP. MANUAL MODE OPERATES NORMALLY & PERFORMED ZONE TEMP CONTROLLER BITE CONDITION NORMAL. CLEANED FLT DECK TEMP SENSOR FILTER. FLIGHT DECK TEMP CONTROL CONDITION. CHECKS NORMAL IAW AMM 21-61-03.SDR ASAA2016081017668Unknown · unknownRIGHT PACK LIGHT ILLUMINATES DURING RECALL, THEN EXTINGUISHES ON MASTER CAUTION RESET. PRESSURIZATION AND AIR CONDITIONING APPEAR NORMAL. ACFT GROUNDED. PERFORMED BITE TEST OF TEMPERATURE CONTROLLER, REF AMM 21-61-00, FOUND TEMPS CONTROL VALVE FAULTED ON NRSDR P5CA2016080900189Filter · dirtyAUTO-MODE FUNCTION OF FLIGHT DECK IS NOT ABLE TO MAINTAIN A DESIRED TEMP, VARIES BETWEEN 170-28C. PERFORM FIM 21-61 FAULT TREE 912 PERFORM ZONE TEMP CONTROLLER TEST CONDITION. NORMAL. NO FAULT FOUND. CLEANED FLIGHT DECK TEMP SENSOR FILTER AND AUTO-MANUAL MOSDR UIEA2016080900676Controller · malfunctionedZONE TEMP CONTROLLER UNABLE TO MAINTAIN TEMP FLIGHT CREW MODULATION TRIM AIR TO MAINTAIN TEMP. PERFORMED TASK 21-51-14-705-075, PACK TEMP CONTROLLER BITE FOUND LT TSMP COND VALVE FAULT, TESTED GOOD. BITE TEST ZONE TEMP CONTROLLER. AUX ZONE TEMP CONTROLLER SDR P5CA2016080900188Controller · malfunctionedAUTO MODE FUNCTION OF FLT DECK IS NO ABLE TO MAINTAIN A DESIRED TEMPETURE , VARIES BETWEEN 17C -28C. PERFORMED FIM 21 64461-FAULT TREE 912 PERFORMED ZONE TEMP CONTROLLER BITE TEST COND NORMAL .NO FAULT FOUNDED. CLEANED FLT DECK TEMP SENSOR, FILTER AND AUTOSDR P5CA2016080800185Warning System · false activationFORWARD CARGO BACK UP EICAS MSG DISPLAYED FORWARD CARGO AC FAULT DISCRETE LIGHT ILLUMINATED FORWARD CARGO TEMP 39C. PERFORMED FIM 21-61, FAULT TREE 922, NO FAULTS FOUND, CHECKS SERVICEABLE.SDR HALA2016072800148Valve · failedAIRCRAFT 388, ATB DUE TO UNABLE TO CONTROL CABIN TEMP, NR 2 CABIN TRIM AIR VALVE INOPERATIVE, MAX CABIN TEMP 100, MAX TRIM AIR VALVE 156. REPLACED TRIM AIR VALVE AND PERFORMED SYSTEM TEST OF COCKPIT AND CABIN TEMP CONTROL, OPERATIONAL CHECK OK.SDR P5CA2016072700175Filter · dirtyFLIGHT DECK TEMP CONTROL SENSOR FILTER DIRTY. IAW AMM 21-61-09, CLEANED THE SENSOR FILTER. CONDITION CHECKED SATISFACTORY.SDR UIEA2016072700640Bulb · inoperativeRT PACK TEMP OUT, BULB INOPERATIVE. REPLACED RIGHT PACK OUT TEMP BULB & TESTED IAW AMM 21-52-06/401.SDR ASAA2016072317456Valve · defectiveFWD CABIN ZONE TEMP LIGHT ILLUMINATED WITH RECALL AND EXTINGUISHED WITH MASTER CAUTION. ACFT GROUNDED. FWD CABIN ZONE TRIM VALVE FAULTS DURING CONTROLLER BITE TEST. REPLACED FWD CABIN ZONE TRIM VALVE IAW AMM 21-61-21-000-801 AND 21-61-21-400-801, OPS CHECKESDR ASAA2016072017438Filter · dirtyFLT DECK PRIMARY TEMP CONTROLLER INOPERATIVE. ACFT GROUNDED. PERFORMED RT PACK ZONE TEMP CONTROLLER BITE AND FOUND FLIGHT DECK TRIM AIR VALVE FAULT CURRENT AND IN HISTORY BUT COULD NOT DUPLICATE IN VERIFY TEST, IAW AMM 21-61-00. VERIFIED OPERATION OF TRIM AISDR ASAA2016071917425Control Valve · failed@ FL 340 AFT CABIN TEMP BECAME HOT. RIGHT PACK TEMP WAS PEGGED AT 100 DEGREES C. ON RECALL, HAD A RIGHT PACK LIGHT. RAN QRH FOR "PACK" & COULD NOT CORRECT. THEN RAN "CABIN TEMP HOT" IN QRH. CABIN COOLED THEN. ACFT GROUNDED. REMOVED AND REPLACED PACK TCV, REF SDR ASAA2016071717402Warning Light · false activationZONE TEMP LIGHT FOR CONTROL CABIN ILLUMINATED ON MASTER CAUTION RECALL. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST, NO FAULTS NOTED. NO ZONE TEMP LIGHT ON RECALL, ALL OPS NORMAL, IAW AMM 21-61-00.SDR ASAA2016071517378A/C Pack · unknownF/A REPORTED INCONSISTENT HEAT & COOLING IN AFT CABIN FRONT TO BACK AND SIDE TO SIDE. AFTER 5 HOUR FLIGHT, UNABLE TO FIND SETTING TO SATISFY AFT CABIN. ACFT GROUNDED. ACCOMPLISHED CABIN TEMP CONTROL & INDICATION TEST IAW AMM 21-61-00-700-807-002. OPS CHECKSDR ASAA2016071517376Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL. GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED FIM 21-62 TASK 848. LIGHT DID NOT ILLUMINATE. PERFORMED BITE B737-800 FIM 21-62 TASK 801. NO FAULTS LOGGED. OPERATED PACK. NO ZONE TEMP LIGHT ILLUSDR COZA20160718084Controller · intermittentLEFT AMBER "PACK" ANNUNCIATOR ILLUMINATED ON RECALL. REPLACED THE PACK ZONE TEMPERATURE CONTROLLER PER THE FIM. OPS CHECKED OK.SDR ASAA2016070917299Warning Message · false activationON RECALL, CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHED & RESET ON MASTER CAUTION RESET PUSH. ACFT GROUNDED. PERFORMED PACK TEMP CONTROL BITE ON BOTH CONTROLLERS, NR 2 CONTROLLER FAULTED "FLIGHT DECK TRIM VALVE". CLEARED FAULT IAW FIM 21-62 TASK SDR WRNA2016F00149Controller · inoperativeDURING CRUISE, UPPER CABIN AND ALL DECKS TEMPERATURE EXCEEDED 60 DEGREES C. RETURNED TO DEPARTURE. EMERGENCY NOT DECLARED. TROUBLESHOOTING FOUND A DEFECTIVE ZONE TEMPERATURE CONTROLLER. CONTROLLER WAS REMOVED AND REPLACED, OPERATIONAL SYSTEM CHECK SATISFACSDR AALA20160708003Control Valve · stuckDURING CLIMB CREW WAS UNABLE TO CONTROL CABIN TEMPERATURE. EMERGENCY DECLARED. LANDING UNEVENTFUL. AIRCRAFT WAS GROUNDED. MAINTENANCE FOUND THE RIGHT ZONE TEMPERATURE CONTROL VALVE STUCK PARITALLY OPEN. REMOVED AND REPLACED THE CONTROL VALVE IAW AMM 21-51-10SDR AALA20161229008Controller · faultyCABIN TEMPERATURE NEVER REDUCED AFTER TAKE-OFF. RIGHT PACK PUTTING OUT HOT AIR / LEFT TEMPERATURE CONTROLLER INOPERATIVE. CABIN REACHED MAX OF 99 DEGREES. THE AIRCRAFT WAS GROUNDED. REPLACED THE CABIN TEMPERATURE CONTROLLER AND CLEANED ZONE TEMPERATURE SENSOR.SDR ASAA2016070617284Control Valve · failedF/A REPORTED CABIN VERY HOT AT ROWS 6-14. ACCOMPLISHED QRH PROCEDURE, TRIM-AIR OFF, THEN CABIN TEMP STABILIZED TO NORMAL. TRIM AIR SWITCH REMAINED OFF. ACFT GROUNDED. PERFORMED PACK FLOW TEMP CONTROL BITE IAW FIM 21-62 TASK 801. GROUND TEST PASSED ON BOTH SDR ASAA2016070617283Warning Light · illuminatedCONTROL CABIN ZONE TEMP ON, AT RECALL. CLEARS WITH MC RESET. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE CHECK OF BOTH LEFT & RIGHT CONTROLLERS IAW AMM 21-60-00-700-806-002. FOUND "CABIN SENSOR " LIGHT RED ON BOTH CONTROLLERS FOR FLIGHT DECK. UPSDR AALA20160705003Valve · malfunctionedDURING CRUISE RIGHT PACK ZONE TEMP CONTROL UNCONTROLLABLE. EXCESSIVE HEAT IN CABIN. PERFORMED AN EMERGENCY LANDING WITHOUT FURTHER INCIDENT. REMOVED AND REPLACED AFT ZONE TRIM VALVE RIGHT PACK IAW AMM 21-61-21. LEAK CHECK GOOD, OPERATIONS CHECK GOOD, BITE CHSDR ASAA2016070417257Warning Light · false activationFWD CABIN ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. NR 2 CONTROLLER LOGGED ZONE TRIM VALVE PREVIOUS FLIGHT, RESET FAULT. ACCOMPLISHED BITE TEST, IAW AMM 21-61-00, TEST PASSED.SDR ASAA2016070317247Controller · faultedCONTROL CABIN ZONE TEMP CAUTION ON RECALL. ACFT GROUNDED. VERIFIED CONTROLLER CABIN ZONE TEMP CAUTION ON RECALL, ACFT CHECKED & RELEASED IAW MEL 21-21F. TROUBLESHOT IAW FIM 21-62, TASK 848 & 801. FOUND FAULT ON ZONE TEMP CONTROLLER 2, TRIM VALVE FLIGHT DECSDR ASAA2016070217214Controller · malfunctionedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON "RECALL" ONLY NO RESET. ACFT GROUNDED. NR 2 CONTROLLER SHOWS TRIM VALVE FLT DECK FAULT. FAULT CLEARED & BITE TEST GOOD IAW AMM 21-61-20.SDR ASAA2016062117108Unknown · unknownUPON ARRIVAL AT AIRCRAFT, FOUND ALL 3 TEMPERATURE SELECTORS IN THE OFF POSITION. AFTER APPLYING APU BLEED AIR PRIOR TO ENGINE START WITH APU ON, ZONE TEMP LIGHT ILLUMINATED ON CONTROLLER CABIN, CLEARED W/ MASTER CAUTION RESET. ACFT GROUNDED. REF FIM 21-62, SDR AALA20160612006Shutoff Valve · faultyAIRCRAFT WAS GROUNDED. AIR INTERRUPT, EMERGENCY NOT DECLARED. LANDING UNEVENTFUL. ACFT NOT OVERWEIGHT. DURING CRUISE THE FLIGHT DECK TEMPERATURE INCREASED AND BECAME UNCONTROLLABLE. MAINTENANCE R & R THE TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE IAW SDR ASAA2016061217015Warning Light · false activationCABIN ZONE TEMP LIGHT ON RECALL AFTER STARTING ENGINES. ACFT GROUNDED. PERFORMED PACK ZONE TEMP BITE CHECK IAW AMM 21-60-00 ON BOTH CONTROLLERS, FOUND NR 2 CONTROLLER FLIGHT DECK RED LIGHT ON. BITE CHECK CLEARED ALL FAULTS AND PERFORMED BITE. NO DEFECTS NOTSDR ASAA2016060816993Bulb · failedOUTPUT TEMP OF RT & LT PACKS ARE NOT THE SAME IN CRUISE FLIGHT. RIGHT PACK IS STABLE 22C. LEFT PACK VARIES FROM 0-10C IN A SLOW CYCLE. TRIM AIR ON. ACFT GROUNDED. R & R LT PACK TEMP BULB T488 IAW WDM 21-61-51. LEFT PACK TEMP INDICATION NORMAL.SDR P5CA2016060300127Controller · malfunctionedUNABLE TO MAINTAIN FWD LOWER CARGO COMPARTMENT TO 1 DEGREE C TO COMPLY WITH NOTOC REQUIRMENT IAW AMM 21-28-00 THE FWD CGO TEMP CONTROL IS BETWEEN 4 DEGREES C-25 DEGREES C IAW AMM 21-28-00. DO THE FWD CARGO TEMP CONTROL SYS TESTSDR ASAA2016060316933Control Valve · failedRIGHT PACK LIGHT ON RECALL, EXTINGUISHED WITH RESET. ACFT GROUNDED. BITE OF RT PACK/ZONE TEMP CONTROLLER IAW FIM 21-62, TASK 801, SHOWED "THIS PACK TCV" AND VERIFY TEST CONFIRMED FAULT. ACCOMPLISHED T/S FOR RT PACK TEMP CONTROL VALVE IAW FIM 21-62 TASK 831. SDR ASAA2016060316932Control Valve · failedRIGHT "PACK" LIGHT ILLUMINATED DURING MASTER RECALL ON DESCENT, CHECK LIGHT EXTINGUISHES WHEN MASTER CAUTION RESET. ACFT GROUNDED. CONFIRMED FAULT, RT PACK/ZONE TEMPERATURE CONTROLLER BITE, REF AMM TASK 21-61-00-700-806-002 SHOWS HARD FAILURE, TCV NR 2, V141,
Back to JASC 2160