JASC 2160
Service difficulty reports · 3,041
Reports filed under 2160 · Cabin Temperature Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2016060216934Warning Light · false activationUPON RECALL ZONE TEMP CONT CABIN LIGHT ILLUMINATED. ACFT GROUNDED. T/S FIM 21-61-TASK 801. BITE CHECK BOTH ZONE TEMP CONTROLLERS NO FAULTS, CLEANED FLIGHT DECK SENSOR. OPS CHECK NORMAL. NO RECALL LIGHT INDICATION.SDR UIEA2016060300399Indicator · inoperativeFORWARD COMPARTMENT TEMP READOUT INOPERATIVE.SDR ASAA2016060116914Warning Light · false activationCONTROLLER CABIN ZONE TEMPERATURE ILLUMINATES ON RECALL GOES OUT WITH RESET. ACFT GROUNDED. ACCOMPLISHED BITE TEST ON BOTH TEMP CONTROLLERS, REF FIM 21-62, TASK 801, NO FAULTS FOUND.SDR ASAA2016053016892Warning Light · false activationCONTROLLER CABIN ZONE TEMP ILLUMINATED ON RECALL AFTER ENGINGE START. EXTINGUISHES WHEN MASTER CAUTION PRESSED. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE, BOTH NR 1 & NR 2, REF FIM 21-62, TASK 801, BITE TEST PASSES, 10 TIMES AND NO FAULT HSDR ASAA2016052816863Sensor · dirtyCONTROLLER CABIN TEMP IS DIFFICULT TO CONTROL. SOME ROTATION OF TEMP MAKE IT TOO HOT OR TOO COLD. ACFT GROUNDED. CLEANED SENSORS IN COCKPIT, FWD CABIN. TEMP CONTROLLER NOT FAULTING. OPS CHECK GOOD IAW FIM 21-62, TASK 814.SDR ASAA2016052616857Warning Light · false activationZONE TEMP, CONTROL CABIN ILLUMINATED ON MASTER RECALL ON PUSH BACK. ACFT GROUNDED. ZONE TEMP CONTROL CABIN LIGHT NO LONGER ILLUMINATED IAW FIM 21-62, TASK 801. NO EXISTING FAULTS AND GROUND TEST PASSED, MEL CLEARED.SDR ASAA2016052216816Control Valve · failedCABIN TEMP VERY HOT IN FWD CABIN 6-15, ROW, QRH FOLLOWED, CABIN TEMP LOWERED WITHIN SHORT TIME PERIOD. "TRIM SWITCH OFF". ACFT GROUNDED. BITE TESTED TEMP CONTROLLERS, REF FIM 21-61-00-810-801. VERIFIED FAULT, ACCESSED 4 CEILING PANELS FROM ROWS 6 TO 15, NO DSDR ASAA2016052216815Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. LIGHT RESETS WITH MASTER CAUTION RESET. COMPLIED WITH QRH PROCEDURE, NO CHANGE. LIGHT ILLUMINATES ON RECALL. ACFT GROUNDED. ACCOMPLISHED BITE OF PTC, REF FIM 21-62, TASK 801, FAULTED ON NR 2 PTC FLIGHT DECK TRIM VALSDR ASAA2016052116803Warning Message · false activationZONE TEMP FOR CONT CAB ILLUMINATES ON RECALL AND EXTINGUISHES ON RESET. ACFT GROUNDED. PERFORMED PACK CONTROLLER BITE TEST, REF FIM 21-62, TASK 801. RAN LT PACK, FAULT INTERMITTENT, NO ZONE TEMP LIGHT. BITE TEST PASSED, NO HISTORY 60 DAYS.SDR ASAA2016052116798Warning Light · false activationCONTROLLER CABIN ZONE TEMP AMBER LIGHT CAME ON AFTER RECALL. AFTER ENGINE START LIGHT GOES OUT ON RESET. ACFT GROUNDED. ACCOMPLISHED PACK TEMPERATURE CONTROL BITE IAW FIM 21-62, TASK 801. NO DEFECTS NOTED. SUSPECT NUISANCE FAULT REF FTD 737NG-FTD-21-16001.SDR ASAA2016052016801Filter · dirtyCONTROL CABIN ZONE TEMP ILLUMINATES ON RECALL, EXTINGUISHES ON RESET. ACFT GROUNDED. RIGHT PZTC LOGGED FLIGHT DECK TRIM VALVE. RESET RIGHT PZTC. CLEANED FLIGHT DECK TEMP SENSOR FILTER, REF AMM 21-61-06-201. RAN PACK FOR 45 MINUTES AT VARIOUS SELECTED TEMPESDR ASAA2016051916800Filter · dirtyF/A REPORTED CABIN TEMP VERY HOT FROM ROWS 6-15. FOLLOWED QRH PROCEDURE-TURNED TRIM AIR SWITCH OFF. AFTER 15 MINUTES CABIN TEMP WAS REPORTED VERY GOOD. TRIM AIR SWITCH LEFT IN OFF POSITION. ACFT GROUNDED. ACCOMPLISHED FIM TASK 21-62, 801, P/2 TEMP CONTROLSDR ASAA2016051916799Warning Light · false activationON RECALL CONT CAB ZONE TEMP ILLUMINATED. RESETS WITH MASTER CAUTION. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROL BITE, REF FIM 21-62, TASK 801. FOUND FLIGHT DECK TRIM VALVE FAULT. COMPLETED VERIFY TEST, NO FAULTS FOUND. CLEARED FAULT, PACK TEMP CONTROLSDR ASAA2016051816767Warning Light · false activationCONTROLLER CAB ZONE TEMP LIGHT ON RECALL. RESETS ON MASTER CAUTION RESET. ACFT GROUNDED. F/D SELECTOR FAULT, 21-51311 CODE. RESET IAW FIM 21-62 TASK 805. PTC BITE OPS NORMAL IAW FIM 21-62, TASK 801.SDR HALA2016051800102Valve · failedAIRCRAFT DIVERTED DUE TO THE NR 3 CABIN TRIM AIR VALVE FAILED IN THE FULL HOT POSITION. REPLACED THE TRIM AIR VALVE.SDR HALA2016051900199Valve · failedNR 3 CABIN TRIM AIR VALVE FAILED IN THE FULL HOT POSITION. R & R TRIM AIR VALVE, 633HK, IAW TSM 21-63-00-810-824-A. OPS CHECK GOOD. OK FOR SERVICE.SDR ASAA2016051716779Warning Light · false activationON RECALL, AIR CONDITION-ZONE TEMP LIGHT ILLUINATED. RAN QRH. LIGHT RESET ON MASTER CAUTION SYS RESET. SYSTEM OPS NORMAL. GROUNDED. NR 2 PZTC LOGGED FLIGHT DECK TRIM VALVE. COULD NOT DUPLICATE MALFUNCTION. PZTC BITE CHECK NORMAL SEVERAL TIMES. DURING BITESDR ASAA2016051716766Warning Light · false activationON PUSHBACK ZONE TEMP LIGHT ILLUMINATED, EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. BITE CHECK OF ZONE TEMP CONTROLLERS SHOWS NO FAULTS. NO PRIOR HISTORY 90 DAYS IN TRAX. SYSTEM OPS NORMAL, REF AMM 21-60-00. RAN PACKS WITH NO DISCREPANCIES NOTED.SDR ASAA2016051716765Warning Light · false activationCONTROLLER CAB ZONE TEMP ILLUMINATES ON RECALL. ACFT GROUNDED. BITE OF BOTH CONTROLLERS SHOWS CABIN SENSOR FAULT FOR PREVIOUS FLIGHT. FOUND CABIN SENSOR FILTER CLOGGED. CLEANED FILTER, REF AMM 21-61-06-100-801. BITE TEST BOTH CONTROLLERS CHECKS GOOD, REF ASDR ASAA2016051516736Control Valve · failedLEFT PACK LIGHT ON RECALL AFTER START. ACFT GROUNDED. VERIFIED FAULT. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST, CONTROLLER NR 1 SHOWS TCV FAULT FOR LT PACK. CONTROLLER NR 2 SHOWS NO FAULTS. ACFT REQUIRES TEMP CONTROL VALVE, V139 REF AMM 21-61-00-700SDR ASAA2016051316707Filter · cloggedF/A'S AND PAX COMPLAINED ABOUT CABIN TEMP. MOSTLY STAYING TOO COLD WITH TEMP SELECTORS IN 2 O`CLOCK POSITION AND THOUGH FURTHER MOVEMENT TOWARD 3 O`CLOCK RESULTED IN TEMP BEING VERY HOT. ACFT GROUNDED. FOUND FWD AND AFT CABIN TEMP SENSOR FILTERS CLOGGED. CSDR ASAA2016051216705Controller · failedRIGHT PACK LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. RIGHT PACK LIGHT EXTINGUISHED WHEN MASTER CAUTION WAS RESET. ACFT GROUNDED. ACCOMPLISHED BITE OF BOTH PTC, NR 1 HAD STANDBY PACK FAULT AND WOULD NOT RESET REF FIM 21-63, TASK 801 AND 802. REPLACED SDR ASAA2016051116693Warning Light · false activationZONE TEMP CONT CABIN ILLUMINATES ON MASTER RECALL AND DOES NOT RESET. ACFT GROUNDED. ACCOMPLISHED PACK FLOW TEMP CONTROLLER, PFTC, BITE, PASSED IAW AMM 21-61-00-740-801-002. GROUND VERIFICATION SUCCESSFUL.SDR ASAA2016051116692Warning Light · false activationON MASTER CAUTION RECALL, 3 ZONE TEMP LIGHTS ON, RESET WHEN MASTER CAUTION RECALL RESET. ACFT GROUNDED. ACCOMPLISHED PACK TEMP BITE PROCEDURE REF FIM 21-62-801, NR 1 AND NR 2 CONTROLLERS LOGGED FLT DECK TRIM AND CABIN TRIM VALVE FAULTS. ALL FAULTS RESET ON SDR ASAA2016051016684Valve · failedDURING CLIMBOUT AFT CABIN RAN HIGH AT 46 DEGREES C AND WOULD NOT COOL WITH FULL COLD SELECTED. RAN CHECKLIST AND CABIN COOLED WITH TRIM AIR SELECTED OFF. ACFT GROUNDED. R & R AFT CABIN TRIM AIR MODULATING VALVE IAW AMM 21-61-21.SDR ASAA2016050816655Control Valve · failedCONT CAB ZONE TEMP LIGHT ILLUMINATES ON RECALL, CAN BE RESET. ACFT GROUNDED. CLEANED ALL 3 CABIN TEMP SENSOR FILTERS. ACCOMPLISHED PACK FLOW TEMP CONTROLLER BITE, LT BITE TEST PASS NO FAULTS. RT SHOWS FAULT CODES 21-51266 AND 21-51267 BOTH ARE FOR TEMP CONTSDR ASAA2016050716635Warning Light · false activationZONE TEMP FOR CONTROL CABIN ILLUMINATES WITH RECALL AND EXT WITH MASTER CAUTION RESET. CHECKED & REL IAW MEL 21-21F FLIGHT DECK PRI TEMP CONTROL INOPERATIVE. ACFT GROUNDED. PERFORMED FIM 21-62, TASK 832 AND FAULT CLEARED. GROUND FUNCTIONAL CK GOOD REF FIM SDR ASAA2016050716634Control Valve · failedF/A REPORTED CABIN WAS VERY HOT. FWD CAB SUPPLY DUCT TEMP READ 60 DEGREE C AND WOULD NOT COOL DOWN WITH TEMP SELECTED TO MAXIMUM COOL. QRH RAN, TRIM AIR TURNED OFF AND TEMPERATURE COOLED DOWN. TRIM LIGHT CAME ON AFTER QRH. ACFT GROUNDED. BITE TEST OF RT CONSDR ASAA2016050616631Filter · cloggedFWD CABIN TEMP CONTROLLER REQUIRES MUCH HIGHER POSITION TO MAINTAIN NORMAL TEMP - SOMEWHAT ERRATIC. ACFT GROUNDED. BITE CKD BOTH ZONE CONTROLLERS REF FIM 21-62, TASK 801, NO FAULTS LOGGED. FOUND FWD ZONE FILTER CLOGGED. CLEANED FILTER AND OPS CHECKED REF ASDR ASAA2016050516630Warning Light · false activationZONE TEMP LIGHT ILLUMINATED, CONT CABIN, WITH RECALL LIGHT. EXTINGUISHED PUSHING MASTER CAUTION. ACFT GROUNDED. RT PZTC LOGGED FLT DECK TRIM VALVE. RESET RIGHT PZTC. RAN PACK FOR 45 MINUTES AT VARIOUS SELECTED TEMP. VERIFIED VALVE PASSED WITH NUMEROUS BISDR ASAA2016050416619Warning Light · false activationAFTER ENGINE START, FLOW DISCONNECTED CONTROL CAB ZONE TEMP LIGHT ON MASTER CAUTION RECALL. ACFT GROUNDED. PERFORMED BITE TEST OF PACK/ZONE TEMP CONTROLLERS IAW AMM 21-61-00. FOUND NR 2 CONTROLLER WITH FLIGHT DECK ZONE TRIM VALVE RED FAULT LIGHT ON DURING TSDR ASAA2016050316605Warning Light · false activationZONE TEMP, CONTROLLER CABIN ILLUMINATED UPON RECALL ON DESCENT. ACFT GROUNDED. RIGHT PZTC LOGGED, FLT DECK TRIM VALVE FAULT. COULD NOT DUPLICATE MALFUNCTION. VERIFIED INSTALLED TRIM VALVE WAS A -5 PN. VALVE PASSED NUMEROUS BITE CHECKS. RAN PACK FOR 45 MINUSDR ASAA2016050216594Warning Light · false activationZONE TEMP ON CONTOL CABIN ILLUMINATED DURING AFTER START. ACFT GROUNDED. PERFORMED PFTC BITE ON BOTH NR 1 AND NR 2 PFTC IAW FIM 21-62, TASK 801. NO FAULTS ON EITHER CONTROLLER. R & R CONTROL CABIN SENSOR FILTER IAW AMM 21-61-06. NO FAULTS.SDR ASAA2016050216595Warning Message · false activationCONTROL CABIN ZONE TEMP ILLUMINATES ON RECALL. EXTINGUISHES ON RESET. ACFT GROUNDED. ACCOMPLISHED BITE CHECK OF THE LT AND RT PFTC'S REF AMM TASK 21-61-00-740-801-802. NO FAULTS NOTED. OK FOR SERVICE. MEL 21-21F CLEARED.SDR ASAA2016050116585Controller · failedON RECALL ZONE TEMP LIGHTS ON FWD CAB AND CONT CABIN ILLUMINATES, RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. REF LP 11647860 RT PACK LIGHT ILLUMINATES ON RECALL EXTINGUISHED ON RESET OF MASTER CAUTION, FOUND RT AUTO TEMP CONTROLLER LOGGED, CONTROLLER FASDR ASAA2016043016570Warning Light · false activationCONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXTINGUISHED AFTER RESET. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP. CONTROLLER BITE AND RESET VERIFIED ON 1 AND 2 CONTROLLER CABIN ZONE TEMP LIGHT EXTINGUISHED AND GREEN GO LIGHTS ON REF AMM 21-61-00/501SDR ASAA2016042816562Warning Message · false activationON M/RECALL CK CONTROLLER CABIN ZONE TEMP LIGHT CAME ON. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE, BITE SHOWS PRIMARY COCKPIT TRIM VALVE FAULT. TEST AND RESET NORMAL WITH NO CURRENT FAULTS. ZONE TEMP DOES NOT ILLUMINATED WITH RECALL. REF SDR ASAA2016042716545Warning Light · false activation"ZONE TEMP" LIGHT FOR CABIN CONTROL. RESETS WITH MASTER RECALL. ACFT GROUNDED. REF AMM 21-61-00 PACK FLOW TEMP CONTROLLER BITE, CABIN TEMP & INDICATIONS OPS TEST, NO FAULTS DETECTED AFTER BITE. OPS TEST NORMAL. OPERATED PACKS, COULD NOT DUPLICATE FAULT. AS SDR ASAA2016042616539Valve · failedDURING RECALL CONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATED. ACFT GROUNDED. ACCOMPLISHED FIM 21-62, TASK 832 FOUND FLT DECK TRIM VALVE FAULTED. R & R FLT DECK TRIM VALVE REF MM 21-61-21 RE-ACCOMPLISHED BITE, FIM 21-62, TASK 801, NO FAULTS FOUND. CLEARED MEL 2SDR ASAA2016042516530Control Valve · failedTHERE IS AN ISSUE WITH THE CABIN TEMP CONTROL SYS. OVERHEAD TEMP INDICATOR AND CONTROL PANEL IS NOT AGREEING WITH THE REPORTED TEMPS, MAKING THE CABIN TEMP- ESPECIALLY AFT VERY DIFFICULT TO PROPERLY CONTROL. AFT CABIN IS INDICATING 22C AFT SUPPLY IS INDICATISDR ANCF2016042401Warning System · unknownCABIN PRESSURE SAFETY VLV OPEN CAUTION ON ECAM. IAW AMM 21-61-00-710-001 THE TEMP CONTROL PRIMARY WAS PERFORMED. TESTED SATISFACTORY.SDR ASAA2016042316488Warning Light · false activationON RECALL ON AFTER START ZONE TEMP CONTROL ILLUMINATED. MASTER CAUTION RESET LIGHT. ACFT GROUNDED. ACFT CHECKED. PERFORMED BITE TEST ON PACK FLOW TEMPERATURE CONTROLLER, NO FAULTS NOTED REF AMM 21-61-00-740-801-002. RAN ACFT AND PERFORMED RECALL, NO LIGHSDR ASAA2016042216487Warning Light · false activation" CONT CAB-ZONE TEMP" LIGHT ON RECALL. ACFT GROUNDED. ACFT CHECKED AND RELEASED IAW MEL 21-21F, CABIN ZONE TEMP CONTROL INOPERATIVE. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROLLER BITE TEST REF AMM 21-61-00, OPS TEST GOOD. NO FURTHER DEFECTS NOTED. THIS CLEASDR MTNA20160422001Control Valve · faultyDURING CRUISE AT FL 190, HOT AIR STARTED COMING OUT OF DUCTS & TEMP CONTINUES TO GET HOTTER, TEMP ABOVE 100 DEGREES. TEMP SWITCHED TO MANUAL MODE & NOTHING CHANGED, RAN THE CHECKLIST, DECLARED AN EMER & RETURNED TO FIELD. R & R NR 1 TEMPERATURE CONTROL VALVESDR ASAA2016041716431Warning Light · false activationON RECALL, ZONE TEMP LIGHT ILLUMINATED FOR THE CONTROL CABIN. EXTINGUISHES ON RESET. ACFT GROUNDED. RAN CONTROL CABIN THROUGH TEMP RANGE MAX HOT-COLD AND ACCOMPLISHED BITE TEST, REF AMM 21-61-00. NO FAULTS NOTED.SDR ASAA2016041616407Warning Light · false activationZONE TEMP LIGHT FOR CONT CAB CAME ON DURING TAXI OUT. ACCOMPLISHED QRH PROCEDURES. LIGHT EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED FIM 21-62 TASK 842, INITIAL EVALUATION PASSED. PERFORMED PACK TEMP CONTROL BITE, NO EXISTING FAULTS. SDR ASAA2016041616405Warning Light · false activationON AFTER START ZONE TEMP LIGHT ON RECALL, LIGHT OUT WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED BITE OF THE PACK/ZONE TEMP CONTROLLERS, REF FIM 21-62, TASK 801. FOUND NUISANCE FAULT ON THE NR 2 PACK/ZONE TEMP CONTROLLER FOR THE FLIGHT DECK TRIM VSDR ASAA2016041116346Warning Light · false activationCONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL. EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. FOUND "FLT DECK TRIM VALVE" FAULT LOGGED, COMPLIED WITH FIM TASK 21-61-00. FAULT CLEARED & DID NOT RETURN. OPS CHECK GOOD, NO FURTHER DEFECTS NOTSDR ASAA2016040816298Filter · cloggedON RECALL CHECK LT PACK AMBER LIGHT ILLUMINATES. LIGHT GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROL BITE, NR 2 SHOWS NO FAULTS, NR 1 SHOWS THIS PACK TCV, VALVE 139. CLEARED FAULT. CLEANED ALL 3 CABIN TEMP SENSOR FILTERS SDR ASAA2016040716299Control Valve · failedUPON RECALL, LT PACK LIGHT ILLUMINATED, FOLLOWED QRH PRESSED MASTER CAUTION TO RESET, PACK LIGHT EXTINGUISHED. ACFT GROUNDED. LT PACK/ZONE TEMP CONTROLLER, M1442 FAULTED, THIS PACK TCV. REPLACED LT PACK TEMP CONTROL VALVE, V139 ZONE TEMP BITE PASSES. INST
Back to JASC 2160