SDR ASAA2015022010710Warning Light · false activationUPON PUSH BACK STARTUP IN MCO MASTER CAUTION RECALL TEST REVEALED ZONE TEMP LIGHT ILLUMINATED EXTINGUISHED WHEN MASTER CAUTION RESET BUTTON PRESSED. ACFT GROUNDED. PERFORMED BITE CK OF NR 2 TEMP CONTROLLER. FOUND INTERMITTENT FAULT.SDR ASAA2015021910714Warning Light · false activationCONTROL CABIN ZONE TEMP ILLUMINATES ON RECALL, EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. CONT NR 2 LOGGED FLT DECK TRIM VALVE FAULT - BITE TEST GOOD, FAULT RESET.SDR ASAA2015021910713Warning Light · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATES ON MASTER CAUTION RECALL. ACFT GROUNDED. ACCOMPLISHED ZONE TEMP CONTROLLER BITE TEST REF MM 21-61-00. TEST PASSED. NO HISTORY PAST 30 DAYS.SDR YENA20150209015Valve · failedAIR RETURNED TO DEPARTURE, DUE TO FORWARD FLIGHT DECK TEMPERATURE REACHED 52 DEGREES AND FALLING. PERFORMED TROUBLESHOOTING IAW AMM 21-63-00-810-855. R & R COCKPIT TRIM VALVE, 11HK, OPS CHECK OK IAW AMM 21-63-00-710-004 & IAW AMM 21-63-51-000-001.SDR CA150206003Controller · failed(CAN) ON TAKEOFF ROLL, A LOW POWER ECAM INDICATION PROMPTED A REJECTED TAKEOFF. SPEED AT REJECT WAS 105 KTS. IAW TSM71-00-00-810-941 & 21-63-00-810-913 REPLACED NR 2 FCV IAW 21-51-51 PB 401. ZONE CONTROLLER REPLACED IAW AMM 21-63-34 PB 401. PACK CONTROLLERSDR CA150217006Bypass Valve · unserviceable(CAN) THE ACFT MADE AN UNSCHEDULED RETURN TO BASE & THE PILOTS REPORTED THAT THERE WERE ENVIRONMENTAL FUMES COMING FROM THE OVERHEAD GASPERS & VENTS. INITIATED TROUBLESHOOTING & INSPECTION USING COMPUTER ENVIRONMENTAL SOFTWARE. RT HEAT EXCHANGER BY PASS VLV SDR ASAA2015020410555Indicator · erraticAIR CONDITIONING TEMPERATURE GAUGE ERRATIC. ACFT GROUNDED. R & R P5-17 PANEL. OPS GOOD. GROUND VERIFICATION SUCCESSFUL REF AMM 21-61-15.SDR ASAA2015020410553Valve · malfunctionedAFT CABIN ZONE TEMP LIGHT ON RE-SET WITH MASTER CAUTION. ACFT GROUNDED. PERFORMED PACK ZONE TEMP CONTROLLED BITE IAW MM 21-61-00-700-806-002 FOUND AFT CABIN ZONE TRIM MODULATING VALVE FAULT. R & R AFT CABIN ZONE TRIM MOD. VALVE IAW AMM 21-61-21 LEAK CHECK GOSDR ASAA2015020310532Warning Light · false activationON RECALL, CONTROL CABIN ZONE TEMP ILLUMINATED. RESET WITH MASTER CAUTION. ACFT GROUNDED. ACCOMPLISHED BITE TEST ON NR 1 AND NR 2 PACK ZONE TEMP CONTROLLERS, FOUND FAULT LIGHT FOR FLIGHT DECK TRIM VALVE ON NR 2 PACK ZONE TEMP CONTROLLER. IAW MM 21-61-00. OPSDR ASAA2015012710451Warning Light · illuminatedCONTROLLER CABIN ZONE TEMP ILLUMINATED ON RECALL, RESETS WITH MASTER CAUTION. ACFT GROUNDED.SDR ASAA2015012710452Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON MC RECALL, RESETS MASTER CAUTION. ACFT GROUNDED. PRIMARY FLT DECK CONTROLLER INOPERATIVE. BITE CHECK SHOWS FLT DECK TRIM AIR VALVE FAULT. VERIFICATION TEST SUCCESSFUL. RESET FAULTS. HAS NO OTHER RECENT RELATED HSDR ASAA2015012510411Control Module · failedAIR TEMP SELECTOR ON OVERHEAD PANEL IN FWD SUPPLY DUCT POSITION INDICATES 0-100 AT TIME, ALSO INDICATES A HIGH TEMP. F/A INDICATE CABIN TEMP IS OK. ACFT GROUNDED. VERIFIED DISCREPANCY. R & R TEMPERATURE CONTROL MODULE REF MM 21-61-15. OPS CKS NORMAL REF MSDR ASAA2015012510409Warning Light · false activationCONT CABIN ZONE TEMP LIGHT ILLUMINATED ON MASTER RECALL RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED BITE CK OF RT AND LT CONTROLLERS. REF 21-61-00MM. FOUND INTERMITTENT RT FAULT. CLEARED FAULT. RAN PAX AND ENGINES. PERFORMED BITE CK. NO FASDR ASAA2015012410387Valve · failedCONTOL CABIN ZONE TEMP ILLUMINATES ON MC RECALL, RESETS WITH MASTER CAUTION. CONTROLLABLE WITH CONTROL CABIN TEMP SELECTOR. ACFT GROUNDED. PERFORMED PACK ZONE TEMP. CONTROLLER BITE TEST IAW AMM 21-61-00. FOUND FAULT ON CONTROL CABIN TRIM AIR MODULATING VALSDR ASAA2015012310390Valve · failedRIGHT PACK ZONE TEMP CONTROLLER FAULTED: RT PACK TCV. ACFT GROUNDED. R & R RT PACK TCV IAW AMM 21-51-10, ZONE TEMP CONTROL NR 2 BITE CHECKED GOOD. IAW AMM 21-61-00. LEAK CHECKED GOOD.SDR ASAA2015012010320Controller · malfunctionedON RECALL, FWD CABIN ZONE TEMP LIGHT ILLUMINATED TEMP SHOWS 52 DEG C WAS UNABLE TO CONTROL THE TEMPERATURE OR GET LIGHT TO GO OUT WITH CHECKLIST. ACFT GROUNDED. PERFORMED BITE TEST OF BOTH CABIN/ ZONE TEMP CONTROLLERS NR 2 CONTROLLER SHOWED ZONE FAULT. RESETSDR ASAA2015011910293Valve · malfunctionedFWD CABIN ZONE TEMP LIGHT ON RECALL, GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. RT PACK/ZONE TEMP CONTROLLER, M1443, SHOWS NUMEROUS FWD CABIN ZONE TRIM AIR VALVE, V144, FAULT. REPLACED FWD CABIN ZONE TCV REF AMM TASK 21-61-21, LEAK CK AND GROUND FUNCTSDR ASAA2015011910292Warning Message · false activationON RECALL, FORWARD CABIN ZONE TEMP ILLUMINATED. ACFT GROUNDED. NR 2 TEMP CONT LOGGED ZONE TRIM VALVE, BITE TEST GOOD, FAULT RESET.SDR ASAA2015011910291Controller · malfunctionedCONTROL CABINE TEMP CONTROLLER NOT WORKING PROPERLY. IN COLDEST SETTING STILL BLOWS OUT HOT AIR. DUCT TEMP HOVERS AROUND 40C REGARDLESS OF KNOB POSITION. ACFT GROUNDED. PERFORMED BITE CHECK ON RT & LT PACK CONTROLLERS IAW PLACARD. NO FAULTS FOUND. NO FAULSDR ASAA2015011810275Warning Message · false activationCONTROL CABIN TEMP ZONE LIGHT ILLUMINATED ON RECALL, TEMP IS CONTROLABLE. ACFT GROUNDED. PERFORMED PACK TEMP CONTROL BITE CHECK IAW MM 21-61-00. NO HISTORY 30 DAYS. PASS "GO" ON BOTH.SDR ASAA2015011810274Knob · looseCONDITION AIR TEMP SELECTOR ON OVERHEAD PANEL IS NOT WORKING. ACFT GROUNDED. FOUND AIR TEMP SELECTOR ASSY MOUNTING HARDWARE WASHER/NUT VERY LOOSE CAUSING AIR TEMP SELECTOR ASSY TO ROTATE WHEN KNOB TURNED. TIGHTENED MOUNTING HARDWARE, AIR TEMP SELECTOR PROPESDR CA150115001Valve · failed(CAN) CREW HAD ISSUES WITH TRIM AIR VALVE. AFTER RESET ATTEMPTS (AS PER MOC), NO IMPROVEMENT IN CABIN/FLIGHT DECK TEMPERATURE HAD OCCURRED. FLIGHT ELECTED TO RETURN. FLT DECK ZONE TRIM AIR VALVE REPLACED IAW AMM 21-61-02-401 OPS CHECK OK.SDR ASMF201503002Mixing Valve · failedAIRCRAFT RETURNED TO PLATFORM DUE TO DURING TAXING, THE DUCT OVER HEAT LIGHT TURNED ON. DURING MX REVISION, THE AIR CYCLE MACHINE IN THE LT AIR CONDITIONED PACK WAS DETECTED WITHOUT TEMPERATURE CONTROL IN MANUAL & AUTOMATIC MODE, SO THE LT AIR CONDITIONED PACSDR ASAA2015010910184Valve · failedAFT CABIN ZONE TEMP LIGHT ILLUMINATED. ACFT GROUNDED. PERFORMED BITE TEST OF PACK ZONE TEMP CONTROLLERS IAW AMM. NR 1 CONTROLLER FAULTS ZONE TEMP CONTROL VALVE FOR AFT CABIN. R & R AFT CABIN ZONE TRIM AIR MODULATING VALVE IAW AMM 21-61-21. OPS CHECKED NOSDR ASAA2015010810186A/C Pack · malfunctionedDIFFICULT TO CONTROL COCKPIT AIR TEMP IN AUTO. ACFT GROUNDED. ACCOMPLISHED BITE TEST OF CABIN TEMP CONTROLLERS, TEST PASS. ACCOMPLISHED FIM 21-61, TASK 861, OPS CHECKED GOOD. FAULT WAS INTERMITTENT IAW STEP I, 6. NO HISTORY LAST 90 DAYS.SDR ASAA2015010810183Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON TAXI WILL NOT RESET. ACFT GROUNDED. PERFORMED ZONE TEMP LIGHT ON FAULT ISOLATION IAW FIM 21-62, TASK 839. PERFORMED ZONE TEMP CONTROLLER BITE. NO EXISTING FAULTS, OK FOR SERVICE REF FIM TASK 21-62, TASK 801.SDR ASAA2015010610160Valve · failedDURING RECALL, CONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATED. ACFT GROUNDED. R & R CONTROLLER CABIN TRIM AIR MODULATING VALVE IAW AMM 21-61-21-000-801/-400-801. OPS AND LEAK CKS GOOD.SDR ASAA2015010610164Warning Light · illuminatedZONE TEMP LIGHT ILLUMINATED ON RECALL, FWD CABINE. ACFT GROUNDED. NR 2 TEMP CONTROLLER LOGGED ZONE TEMP VALVE. RAN BOTH TEMP CONTROLLERS BITE TEST IAW MM TASK 21-61-00-700-806-002 AND CLEARED FAULT. RAN PACKS AND CABIN TEMP RESPONDED ACCORDING TO SELECTIONSDR ASAA2015010610163Warning Message · illuminatedCONT CABIN ZONE TEMP LIGHT COMES ON WITH RECALL AND EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. NR 2 TEMP CONTROLLER LOGGED FLT DECK TRIM AIR FAULT LAST FLT. NO HISTORY LAST 30 DAYS. PERFORMED FIM 21-62 TASK 842 & FAULT CLEARED. GROUND VERIFICATSDR ASAA2014123110102Control Valve · failedAFTER ENGINE START ON RECALL, "MASTER CAUTION" ILLUMINATED AND "ZONE TEMP" ILLUMINATED ON CABIN CONTROL "CONT CAB". FOLLOWED QRH. MASTER CAUTION RESETS BUT TRIP RESET DOES NOT RESET. ACFT GROUNDED. VERIFIED NR 2 CONTROLLER SHOWS FLT DECK TRIM VALVE FAULT OSDR ASAA2014122710064Warning Light · false activationCONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATED. QRH PROCEDURE FOLLOWED. ZONE TEMP LIGHT ILLUMINATES ON RECALL. ZONE TEMP LIGHT EXTINGUISHES UPON MASTER CAUTION RESET. ACFT GROUNDED. NR 2 CONTROLLER SHOWS "FLT DECK TRIM VALVE" FAULT. RESET FAULT. PERFORMED FSDR ASAA2014122510063Filter · dirtyF/A'S REPORT FWD CABIN IS VERY WARM IT DID NOT SEEM TO RESPOND TO TEMP ADJUSTMENTS. BACK COLD, 40 DEGREE DIFFERENCE. ACFT GROUNDED. FOUND CABIN TEMP SENSOR FILTERS CLOGGED, CLEANED IAW MM 21-+61-06-100-001. ZONE TEMP CONTROL, OPS NORMAL REF MM 21-61-00-700-SDR ASAA2014122010010Controller · malfunctionedDURING MASTER CAUTION RECALL, CONTROLLER CABIN ZONE TEMP, AMBER, LIGHT ILLUMINATES. LIGHT EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. NR 2 TEMP CONTROLLER SHOWS "FLT DECK TRIM VALVE" FAULT ON PREV FLT & BIT. VERIFY TEST PASSSES. RESET FAULT. FAULSDR ASAA2014122010009Controller · failedAFT ZONE TEMP LIGHT ILLUMINATES ON RECALL. ACFT GROUNDED. NR 2 TEMP CONTROLLER SHOWS A "CONTROLLER STBY PACK" FAULT ON BIT, PREV FLT, & VERIFY BITE TESTS. WOULD NOT RESET. REPLACED NR 2 TEMP CONTROLLER OPS CHECK SAME GOOD. BITE TEST SAME GOOD. GROUND VERISDR ASAA2014121910008Controller · malfunctionedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. ACFT GROUNDED. ZONE TEMP CONTROLLER 2 FAULTS FLT DECK TRIM VALVE. PERFORMED FIM 21-62, TASK 832. ZONE TEMP LIGHT EXTINGUISHED, AND ZONE TEMP CONTROLLER BITE CK GOOD IAW FIM 21-62, TASK 801. RAN PACKS, NO DEFECTS.SDR ASAA2014121609970Valve · malfunctionedAFT CABIN ZONE TEMP LIGHT ILLUMINATED ON MASTER CAUTION RECALL. ACFT GROUNDED. NR 1 TEMP CONTROLLER BITE PROCEDURE, 21-62 TASK 801 SHOWED ON BIT & PREVIOUS FLT SHOW ZONE TRIM VALVE FAULT. REPLACED: ZONE TRIM AIR MOD VALVE FOR THE AFT CABIN POSITION. REF: AMSDR ASAA2014121509958Control Valve · failedAFT CABIN ZONE TEMP LIGHT CAME ON WITH RECALL. ACFT GROUNDED. R & R AFT CABIN ZONE TEMP TRIM AIR MODULATING VALVE. RAN RT PACK LEAK CHECKED GOOD. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST NO FAULTS FOUND. ALL WORK DONE IAW AMM 21-61-00-700-806-002 SDR ASAA2014121309920Warning Light · false activationAFTER ENGINE START CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. MASTER CAUTION LIGHT EXTINGUISHES AFTER RECALL. ACFT GROUNDED. PACK/ZONE TEMP CONTROLLER BITE IAW MM 21-61-00-700-806-002 SHOWED RT PACK/ZONE TEMP CONTROLLER FAULT FOR CONTROL CABIN TRIM VALVE. PSDR ASAA2014120909906Warning Light · false activationAFTER ENGINE START, DURING MASTER CAUTION RECALL THE COCKPIT ZONE TEMP LIGHT ILLUMINATED. THE LIGHT EXTINGUISHES WHEN MASTER CAUTION SYSTEM IS RESET. ACFT GROUNDED. ACCOMPLISHED, FIM 21-62, TASK 848, NO FAULTS NOTED, NO HISTORY 30 DAYS.SDR ASAA2014120409866Warning Light · false activationCOCKPIT ZONE TEMP LIGHT ILLUMINATES ON RECALL, GOES OUT WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED CAB TEMP CONTINUED BITE FIM 21-62 TASK 801, NR 2 CONTROLLER FAULTED CONT CAB TRIM VALVE. FAULT WAS CLEARED ON RESET AND OPS CHECKED NORMAL AMM 21SDR ASAA2014120209838Warning Light · false activationPUSHING THE MASTER RECALL, YIELDS AN AIR CONDITIONER AMBER LIGHT AND THE RT PAC AMBER LIGHT ON THE OVERHEAD ILLUMINATES. QRH PROCEDURE FOLLOWED. THE AMBER PAC LIGHT EXTINGUISHES WHEN MASTER CAUTION IS RESET, NO FURTHER ACTION REQUIRED-IAW QRH. MAINTENANCE & SDR ASAA2014120109837Warning Light · false activationON RECALL: FWD CABIN "ZONE TEMP" LIGHT ON, EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. TROUBLESHOT IAW FIM 21-62, TASK 834. APPEARS TO HAVE BEEN AN INTERMITTENT FAULT. VERIFICATION TEST NORMAL. CONTROLLER FAULT CLEARED. HAS NO OTHER RECENT HISTORSDR HALA2014120100201Controller · failedAT LANDING, EICAS MID CABIN, AFT CABIN, FWD CABIN, FLIGHT DECK TEMP ILLUMINATED, RECEIVED A VERY HOT, WENT MANUAL, NO RESPONSE. R & R ZONE TEMP CONTROLLER IAW AMM 21-61-03-004-015, DUE TO CONTROLLER. BITE AND OPS CK GOOD.SDR ASAA2014112709770Control Valve · failedAFT ZONE TEMP LIGHT ILLUMINATED. CABIN INTERIOR TEMPERATURE WENT FULL HOT AND WAS UNCONTROLLABLE. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP BITE TEST, REF 21-62, TASK 801. NR 1 CONTROLLER HAS FAULT ZONE TRIM VALVE, HAS HISTORY. REPLACED AFT CABIN TRIM VALVESDR ASAA2014112709769Warning Light · illuminatedPRIOR TO TAXI, AFT CABIN ZONE TEMP AND AIR COND LIGHTS ILLUMINATED ON MASTER CAUTION RECAL AND RESET CLEARED IT. UNABLE TO CONTROL TEMP IN AFT CABIN. AIR SUPPLY DUCT TEMP STABILIZED AT 46 DEGREES C AND COULD NOT BE CONTROLLED. PASS CABIN TEMP STABILIZED AT SDR ASAA2014112509768Sensor · dirtyAFTER ENGINE START CONTROL CAB ZONE TEMP ILLUMINATED ON RECALL. LIGHT WENT OUT AFTER RESET. FOLLOWED QRH. ACFT GROUNDED. CLEANED CONTROL CABIN TEMP SENSOR ASSY FILTER IAW MM 21-61-06. PACK/ZONE TEMP CONTROLLER BITE REF MM 21-61-00 SHOWED TRIM VALVE FLT DESDR ASAA2014112409739Warning Message · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL, EXTINGUISHES ON RESET. ACFT GROUNDED. ACCOMPLISHED BITE CHECK OF BOTH TEMP CONTROLLERS IAW FIM TASK 21-62, TASK 801 & NO FAULTS FOUND. ACCOMPLISHED FIM TASK 21-62, TASK 832 AND FOUND TO BE AN INTERMISDR SIMA20141113004Control Valve · failedAUTO MODE PRESS FAIL IN FLT. CONDUCTED PROCEDURES IAW AOM VOL 1 DEFERE IAW MEL 21-18. M PROCEDURES COMPLIED WITH. AUTO & MANUAL INOPERATIOMS. CORRECTIVE ACTION: PERFORMED OPERATIONS CHECK OF PRESS SYSTEM IN MAN & AUTO IAW AMM 21-31-00. OPERATIONS CHECKED MESDR ASAA2014111209646Sensor · failedCONT CAB ZONE TEMP ILLUMINATED. QRC ACCOMPLISHED, ILLUMINATES ON RECALL. ACFT GROUNDED. PERFORMED PACK/ZONE BITE CHECK IAW AMM 21-61-00-700-806-002. FOUND A "FLT DECK DUCT SENSOR" FAULT. RETESTED AND RECEIVED THE SAME FAULT. REPLACED THE CONTROL CABIN DUCTSDR ASAA2014111009629Warning Light · false activationAFTER RECALL, ZONE TEMP LIGHT FOR COCKPIT ILLUMINATED. ACFT GROUNDED. BOTH CONTROLLERS LOGGED COCKPIT TRIM VALVE FAULT. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE PROCEDURES IAW FIM 21-62, TASK 801 AND CLEARED FAULT. BOTH TEMP CONTROLLERS, OPS CHECKED GOO
Back to JASC 2160