Reports filed under 2160 · Cabin Temperature Control System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2160'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASAA2015062912262Controller · failedAFT CABIN ZONE TEMP ILLUMINATED DURING RECALL CHECK. ACFT GROUNDED. PILOT REPORTS AFT ZONE TEMPERATURE WAS TOO WARM AND UNRESPONSIVE TO THE CONTROLLER. TRIM AIR SELECTED OFF TO ACHIEVE NORMAL TEMP, RIGHT RAM DOOR FULL OPEN LIGHT ON IN CRUISE. GROUND VERIFJun 29, 2015 · N457AS · Boeing 737990ERSDR ASAA2015062912261Control Valve · failedON CLIMB OUT, AT APPROXIMATELY FL220 CONTROL CABIN BECAME VERY WARM AND GOT WARMER AS CLIMB CONTINUED. AT FL 340, THE CONTROL CABIN DUCT TEMP WAS AT 60 DEG C. TEMP CONTROL INPUTS HAD NO AFFECT. FOLLOWED STEPS IN FLEET INFO BULLETIN DATED 9/12/14 WITH NO SUCJun 29, 2015 · N431AS · Boeing 737990ERSDR ASAA2015062912260Grill · brokenFWD & AFT CABIN TEMP SENSOR AIR INLET GRILLES ARE BROKEN. ACFT GROUNDED. REPLACED FWD & AFT CABIN TEMP SENSOR AIR INLET GRILLES IAW T/C N2221000.Jun 29, 2015 · N512AS · Boeing 737890SDR ASAA2015062812249Control Valve · failedCLIMB AND CRUISE, WARM AIR ENTERING FLIGHT DECK & CABIN, ALL ZONE SELECTORS FULL COLD, STILL WARM AIR. ACFT GROUNDED. ACCOMPLISHED BITE ON BOTH PACK TEMP CONTROLERS, BOTH CONTOLLERS FAULTED THE TCU IAW MM FIM 21-62 TASK 801-14584. CLEANED TEMPERATURE SENSORJun 28, 2015 · N431AS · Boeing 737990ERSDR ASAA2015062812246Filter · dirtyDURING MASTER CAUTION RECALL, RECEIVED AIR CONDITIONER MASTER CAUTION ASSOCIATED WITH AFT CAB ZONE TEMP AMBER LIGHT. ACFT GROUNDED. PERFORMED PACK TEMP CONTROL BITE PROCEDURE IAW FIM 21-62, TASK 801, BOTH CONTROLLERS CK GOOD. CLEANED AFT CABIN TEMP SENSOR FIJun 28, 2015 · N457AS · Boeing 737990ERSDR ASAA2015062312198Sensor · dirtyCONTROL CABIN TEMP BECAME UNCONTROLLABLE DURING CLIMB THROUGH FL260 ABOUT 20 MINUTES AFTER TAKEOFF. SUPPLY DUCT TEMP ROSE 44 DEGREES C AND STABILIZED. PLACING CONTROL CABIN TEMP CONTROLLER TO OFF, HAD NO IMPACT. LT PACK DISCHARGE TEMP WAS 37 DEGREES C, RIGHJun 23, 2015 · N508AS · Boeing 737890SDR ASAA2015062312197A/C Pack · malfunctionedUNABLE TO CONTROL FLIGHT DECK TEMP. SUPPLY DUCT REMAINED AT 52. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROL BITE TEST, NO FAULTS BITE TEST PASSED. PERFORMED AIR CONDITION TEMP CONTROL, OPS CHECK IAW AMM 21-60-00-804. SYS OPS NORMAL.Jun 23, 2015 · N508AS · Boeing 737890SDR VNAA2015061000009Controller · odorCREW REPORTED A STRONG ODOR OF FUEL AND EXHAUST COMING THROUGH VENTS WHEN SWAPPING BLEEDS TO APU. MAINTENANCE TROUBLESHOT AND R & R FLIGHT COMPARTMENT TEMPERATURE CONTROLLER AND CHECKED IAW AMM. ACFT RELEASED FOR SERVICE.Jun 10, 2015 · N253PS · Cndair CL6002B19SDR ASAA2015060812026Not Reported · malfunctionedSHORTLY AFTER TAKEOFF, THE FLIGHT DECK AIR TEMPERATURE BECAME UNCONTROLLABLE. BECAME EXTREMELY HOT. SUPPLY DUCT TEMPERATURE IN THE CONTROL CABIN POSITION SHOWED 70 DEG C. DESPITE TURNING DOWN THE TEMPERATURE CONTROL KNOB IN AUTO AND TURNING IT TO THE OFF POJun 8, 2015 · N468AS · Boeing 737990ERSDR ASAA2015060711958Unknown · unknownPAX REPORT OF HOT TEMPS IN THE FWD CABIN. ACCOMPLISH BITE TEST OF NR 1 & NR 2 PACK ZONE TEMP CONTROLLERS AND REPLACE TEMP SENSOR FILTERS. ACFT GROUNDED. PERFORMED BITE TEST OF NR 1 & 32 PACK ZONE TEMP CONTROLLERS. NO FAULTS LOGGED. REPLACED THE FWD AND AFTJun 7, 2015 · N471AS · Boeing 737990ERSDR ASAA2015060611978Control Valve · malfunctionedFWD CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXT ON MAST CAUTION RESET. ACFT GROUNDED. VERIFIED ZONE TRIM FAULT ON THE NR 2 ZONE TEMP CONTROLLER. REPLACED THE FORWARD CABIN ZONE TRIM MODULATING VALVE IAW AMM'S 21-61-21-000-801 AND 21-61-21-400-801. VALVEJun 6, 2015 · N516AS · Boeing 737890SDR ASAA2015060511980Module · failedAFTER ENGINE START DURING RECALL "AIR COND" LIGHT ILLUMINATES ALONG WITH "ALL" 3 ZONE TEMP LIGHTS. NO TEMP CONTROL. "AIR COND" LIGHT EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. FLT DECK AND ZONE SELECTOR FAULTS ON BOTH ZONE TEMP CONTROLLERS. REPJun 5, 2015 · N514AS · Boeing 737890SDR ASAA2015060511957Valve · failedENGINEERING REQUEST PAX REPORT OF HOT TEMPS IN THE FWD CABIN. ACCOMPLISH BITE TEST OF NR 1 & NR 2 PACK ZONE TEMP CONTROLLERS AND REPLACE TEMP SENSOR FILTERS. ACFT GROUNDED. ACCOMPLISHED BITE TEST, NUMEROUS TIMES, BOTH PACK/ZONE TEMPERATURE CONTROLLERS REF AMJun 5, 2015 · N433AS · Boeing 737990ERSDR ASAA2015053011898Control Valve · failedWITH TRIM AIR ON NO CONTROL OF CABIN TEMP. FOLLOWED QRH WITHOUT FIXING PROBLEM. SELECTED TRIM AIR OFF. UNABLE TO CONTROL TEMP IN ALL ZONES. ACFT GROUNDED. ACCOMPLISHED ZONE TEMP CONTROLLER BITES, NR 1 ZONE TEMP CONTROLLER. SHOWS TCV FAIL ON VERIFY, IAW MM 2May 30, 2015 · N423AS · Boeing 737990ERSDR ASAA2015052711877Controller · malfunctionedZONE TEMP FWD CABIN ILLUMINATED ON MASTER CAUTION RECALL. ACFT GROUNDED. BITE OF NR 2 CONTROLLER SHOWS ZONE FAULT LAST LEG. RESET FAULT & RAN BITE REF TASK 21-61-20. OPS CHECK NORMAL.May 27, 2015 · N516AS · Boeing 737890SDR ASAA2015052411815Valve · malfunctionedAFT ZONE TEMP LIGHT ON RECALL, RESETS. ACFT GROUNDED. BITE CHECKED BOTH CONTROLLERS IAW FIM 21-62, TASK 801. NR 1 HARD FAULT AFT ZONE TRIM VALVE. REPLACED PASSENGERS AFT RT TRIM MOD VALVE REF AMM 21-61-21-400-801 & 21-61-21-400-801, OP'S & LEAK CHECK GOOD.May 24, 2015 · N408AS · Boeing 737990ERSDR SIMA20150524003Universal · malfunctionedUNABLE TO CONTROL TEMP IN COCKPIT. TEMP CLIMBING THROUGH FL 190 DROPPED TO +7C IN COCKPIT. R & R NR 1 DIGITAL TEMP CONTROLLER IAW AMM-21-60-04. DID NOT FIX, SEE ITEM NR 2 THIS LOG PAGE.May 24, 2015 · N809AE · Emb EMB135KLSDR ASAA2015052211813Warning Light · false activationCONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROLLER BITE TEST. TEST PASSED IAW AMM 21-61-00. GROUND VERIFICATION SUCCESSFUL. NO HISTORY PAST 60 DAYS FOR CONT CAB ZONE TEMP.May 22, 2015 · N462AS · Boeing 737990ERSDR ASAA2015052011799Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUNINATED ON RECALL. LIGHT GOES OUT AFTER MASTER CAUTION RESET. ACFT GROUNDED. BITE CHECK TO VERIFY FAULT & RESET PACK/ZONE TEMP CONT. CONDUCTED FIM 21-62 TASK 842 TO RE-EVALUATE. ZONE TEMP LT DID NOT ILLUMINATED DEFECT WAS INMay 20, 2015 · N560AS · Boeing 737890SDR ASAA2015051911782Valve · malfunctionedON RECALL, GOT FWD CAB ZONE TEMP LIGHT. EXTINGUISHES WITH MASTER CAUTION RESET. TEMPS NORMAL. ACFT GROUNDED. PERFORMED ZONE TEMP CONTROLLER BITE ON BOTH CONTROLLERS IAW FIM 21-62, TASK 801, FOUND NR 2 CONTROLLER ZONE TRIM VALVE FAULT. REPLACED FWD CAB ZONE May 19, 2015 · N516AS · Boeing 737890SDR ASAA2015051911781Warning Light · false activationCONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATES ON MASTER CAUTION RECALL, LIGHT GOES OUT ON RESET. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE REF FIM 21-62, TASK 801. PREVIOUS FLT LOGGED, FLT DECK TRIM AIR VALVE. NOT CURRENTLY FAULTING ANY COMPONMay 19, 2015 · N537AS · Boeing 737890SDR ASAA2015051811765Warning Light · false activationCONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL AND EXTINGUISHES ON RESET. ACFT GROUNDED. NR 2 PACK ZONE TEMP CONTROLLER LOGGED FLT DECK TRIM VALVE IN FAULT HISTORY. FAULT CLEARS. RAN TEST AGAIN WITH NO FAULTS. NO HISTORY LAST 30 DAYS.May 18, 2015 · N506AS · Boeing 737890SDR ASAA2015051111691Valve · malfunctionedCONTROLLER CAB ZONE TEMP LIGHT ILLUMINATES DURING RECALL. PERFORMED QRH 2.15 ZONE TEMP CHECKLIST. ACFT GROUNDED. PERFORMED PACK ZONE TEMP CONTROLLER BITE ON BOTH 1 & 2 CONTROLLERS IAW FIM 21-62, TASK 801. CONTROLLER 2 SHOWS FLT DECK TRIM VALVE FAULT. REPLACMay 11, 2015 · N517AS · Boeing 737890SDR ASAA2015051011677Controller · faultedAFT ZONE TEMP LIGHT ILLUNINATED IN AT AT FL340. ACFT GROUNDED. PERFORMED BITE CHECK OF NR 2 PACK/ZONE TEMP CONTROLLER, FAULTED STDBY CONTROLLER FAULT. DUE TO CONTROLLER HISTORY, REPLACED NR 2 PACK/ZONE TEMP CONTROLLER IAW 21-61-20-000-801/400-801, OPS CHECK May 10, 2015 · N413AS · Boeing 737990ERSDR ASAA2015050111587Valve · malfunctionedAFTER ENGINE START, UPON MASTER RECALL, FWD CABIN ZONE TEMP LIGHT COMES ON. FLIGHT CREW ENROUTE MEL. ACFT GROUNDED. ZONE TEMP CONTROLLER NR 2 FAULTED: FWD CABIN TRIM MODULATION VALVE. REF, AMM 21-61-00. REPLACED FWD CABIN TRIM MOD VALVE WITH NEW. REF: AMMMay 1, 2015 · N462AS · Boeing 737990ERSDR ASAA2015043011586Warning Light · false activationON MASTER CAUTION RECALL, ZONE TEMP FWD CABIN LIGHT ILLUMINATED. LIGHT EXTINGUISHED WITH SYSTEM RESET. ACFT GROUNDED. ACCOMPLISHED ZONE TEMP CONTROL BITE. TEST PASSED REF AMM 21-61-00/501. GROUND VERIFICATION SUCCESSFUL. NO HISTORY.Apr 30, 2015 · N462AS · Boeing 737990ERSDR ASAA2015042611519Controller · failedON RECALL "AIR CONDITIONING" ANNUNCIATOR LIGHT NOT ILLUMINATING WITH CURRENT MEL CONDITION. ACFT GROUNDED. FOUND RIGHT PACK CONTROLLER FAILED WITH "STBY PACK" LIGHT ILLUMINATED. T/S IAW FIM 21-62, TASK 802. REPLACED RT PACK CONTROLLER IAW AMM REF 21-61-20--Apr 26, 2015 · N413AS · Boeing 737990ERSDR ASAA2015042511518Valve · malfunctionedCONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATED UPON DEPARTURE-LIGHT WENT OUT WHEN MASTER CAUTION WAS RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST IAW MM 21-61-00-700-806-002. NR 2 TEMP CONTROLLER LOGGED FLT DECK TRIM VALVE. REPLACEDApr 25, 2015 · N440AS · Boeing 737990ERSDR ASAA2015042511517Valve · failedF/A REPORTS HOT TEMPERATURE SPOT BETWEEN ROW 6 AND 13. ACFT GROUNDED. PERFORMED CABIN TEMPERATURE CONTROLLER BITE CKS. REF FIM 21-61TASK 801. FOUND FAULT ON FWD ZONE, TRIM AIR MOD VALVE. REPLACED FWD ZONE, TRIM AIR MOD VALVE REF. AMMM 21-61-21. OPS CKS NORMALApr 25, 2015 · N402AS · Boeing 737990ERSDR ASAA2015042511514Controller · malfunctionedZONE TEMP. ANNUNCIATOR LIGHT CAME ON DURING RECALL. FOLLOWED QRH PROCEDURE. ACFT GROUNDED. ACCOMPLISHED ZONE TEMP CONTROL BITE AMM 21-61-00. OPS CHECK NORMAL GROUND VERIFICATION SUCCESSFUL NO HISTORY 30 DAYS.Apr 25, 2015 · N534AS · Boeing 737890SDR ASAA2015042511513Controller · malfunctionedCONT CABIN ZONE TEMP LIGHT ILLUMINATED, UPON DEPARTURE FOLLOWED QRH LIGHT WENT OUT AFTER MASTER CAUTION RESET WAS PUSHED. ACFT GROUNDED. PERFORMED BITE CHECK ON NR 1 & 2 ZONE TEMP CONTROLLER, NO FAULTS NOTED, ZONE TEMP LIGHT REMAIN EXTINGUISHED AND NO 30 DAYApr 25, 2015 · N440AS · Boeing 737990ERSDR ASAA2015042211463Controller · failedAFTER LANDING ON RECALL THE AFT CAB ZONE TEMP ILLUMINATED. EXTINGUISHED ON RESET OF THE MASTER RECALL SYSTEM. GROUNDED - YES. WHILE ON DEFERRAL, ON RECALL "AIR CONDITIONING" ANNUNCIATOR LIGHT NOT ILLUMINATING WITH CURRENT MEL CONDITION. FOUND RIGHT PACK CONTROApr 22, 2015 · N413AS · Boeing 737990ERSDR ASAA2015042211462Valve · failedCONTROLLER CAB ZONE TEMP PRIMARY CONTROLLER INOPERATIVE. ACFT GROUNDED. REPLACED CONTROLLER CAB ZONE TEMP PRIMARY CONTROLLER AS REQUIRED. LEAK CKD GOOD, OPS CKD GOOD. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST, NO FAULTS FOUND. REF AMM 21-61-21-860-008.Apr 22, 2015 · N588AS · Boeing 737890SDR ASAA2015041411354Warning Message · false activationON RECALL,CONT CAB "ZONE TEMP" IT ILLUMINATES. RESETS WITH MASTER CAUTION. ACFT GROUNDED. NR 2 ZONE CONT LOGGED FLT DECK TRIM VALVE FAULT. CLEARED SAME AND CKS NORMAL IAW 21-61-00. GROUND CONFERANCE SUCCESSFUL.Apr 14, 2015 · N459AS · Boeing 737990ERSDR KCQA2015040901Display · malfunctionedPILOT PRIMARY FLIGHT DISPLAY (PFD), DISPLAYED A TURN IN THE OPPOSITE DIRECTION PROVIDED MISLEADING AND INACCURATE DATA TO THE PILOT IN COMMAND DURING A TURN AFTER TAKEOFF. PILOT DIVERTED TO NEAREST SUITABLE AIRPORT. AFTER UNLOADING THE CARGO AND ON A SUBSEQUENApr 9, 2015 · N299CZ · Beech 99SDR ASAA2015040411221Controller · faultedCONT CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL AFTER START. LIGHT RESETS W/ MASTER CAUTION RESET AND TEMPERATURE DOES RESPOND TO RHEOSTAT. ACFT GROUNDED. ACCOMPLISHED BITE OF TEMP CONTROLLERS, CLEARED FLIGHT DECK TRIM VALVE FAULT ON NR 2 CONTROLLER. NO FApr 4, 2015 · N431AS · Boeing 737990ERSDR ASAA2015040111201Module · failedAFTER ENGINE START AND RECALL CHECK. ALL 3 ZONE TEMPS LIGHTS ILLUMINATED. LIGHTS WOULD EXTINGUISHED ON RESET. TEMP CONTROLLERS DID NOT MOVE PACK TEMP. AFT CABIN SUPPLY DUCT AND AIR TEMP INDICATOR SHOWS HIGH TEMP WHEN SELECTOR FULL COLD AND FLUCTUATES. ACFApr 1, 2015 · N513AS · Boeing 737890SDR ASAA2015033111190Warning Light · false activationZONE TEMP CAUTION, CONT CAB, EXTINGUISHES WHEN M/C RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE PROCEDURE, REF FIM 21-62, TASK 801. FOUND FAULT ON NR 2 CONTROLLER FOR FLIGHT DECK TRIM VALVE. FAULT CLEARED ON SYS TEST. RAN APU AND PACKS,Mar 31, 2015 · N517AS · Boeing 737890SDR ASAA2015032911162Selector · failedCONT CABIN SUPPLY DUCT TEMPERATURE INDICATOR IS ERRATIC AND UNREADABLE. ACFT GROUNDED. RECONFIRMED, "CONT CAB" POSITION MALFUNCTIONING AND BEING ERRATIC. R & R CABIN TEMP SELECTOR REF AMM 21-61-07. OPS TEST NORMAL.Mar 29, 2015 · N535AS · Boeing 737890SDR ASAA2015032811138Control Panel · malfunctionedSUPPLY DUCT GAUGE READS INTERMITTENTLY HIGH. CONT-50/AFT 55-70, FWD-40. ALL ARE INTERMITTENT. F/A'S REPORT TEMP A LITTLE COOL, BUT NO WAY TO TELL ON SUPPLY GAUGE. ACFT GROUNDED. SUPPLY DUCT TEMPERATURE GAUGE DOES NOT INDICATE CABIN TEMPERATURE. REF CABIN Mar 28, 2015 · N513AS · Boeing 737890SDR ASAA2015032811144Control Module · failedON TAXI OUT SAW ALL 3 ZONE TEMP LIGHTS HAD ILLUMINATED WITH NO ASSOCIATED MASTER CAUTION. ALL 3 RESET WITH PUSH TO RESET. NO CONTROL OVER ANY TEMPERATURES. ACFT GROUNDED. BOTH ZONE TEMP CONTROLLERS FAULTED CABIN ZONE AND FLT DECK SELECTOR FAULTS. ACCOMPLISMar 28, 2015 · N513AS · Boeing 737890SDR ASAA2015032711137Module · failedAFT SUPPLY DUCT AIR TEMP INDICATION FLUCTUATES BETWEEN 20-60 DEG C, WITHOUT MOVING AFT CAB TEMP SELECTOR. ACTUAL CABIN TEMPS SEEM NORMAL. ACFT GROUNDED. VERIFIED P5-17 CAB TEMP CONTROL MODULE CAUSING FLUCTUATION. R & R P5-17 CAB TEMP CONTROL MODULE REF MM Mar 27, 2015 · N513AS · Boeing 737890SDR ASAA2015032611140Fan · failedFWD CABIN TEMP CONTROLLER ERRATIC. ACFT GROUNDED. WHILE ON DEFERRAL, F/A COMPLAIN TEMP HOT IN BACK. UNABLE TO COOL IT DOWN FROM COCKPIT BELOW 20 C DUCT TEMP. R & R FWD CABIN TEMP SENSOR FAN IAW 21-61-11. OPS TESTS COMPLETE WITH NO FAULTS.Mar 26, 2015 · N435AS · Boeing 737990ERSDR ASAA2015032511115Controller · malfunctionedCABIN FWD AND AFT CABIN TEMP. CONTROLLERS WILL NOT STABILIZE CABIN TEMP IN AUTO WITH TRIM AIR SWITCH ON. FWD TEMP CONTROLLER SEEMS MOST AFFECTED, WITH TRIM AIR OFF POSITION THE CABIN IS CONTROLLABLE IN AUTO AS THE TEMP. IS AVERAGED THROUGHOUT THE CABIN. ACFMar 25, 2015 · N435AS · Boeing 737990ERSDR ASAA2015032411101Valve · failedAUTO TEMP NOT CONTROLLING CABIN TEMPERATURE. ACFT GROUNDED. REPLACED V146 TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE MM 21-62-01. REPAIR CONFIRMATION PASSES IAW FIM 21-61, TASK 864. ABLE TO CONTROL ALL 3 ZONES INDEPENDENTLY AND IN BOTH DIRECTIONS.Mar 24, 2015 · N435AS · Boeing 737990ERSDR ASAA2015032311085Sensor · dirtyFWD CAB TEMP CONTROL VERY ERRATIC IN AUTO, WORKS WELL IN OFF. ACFT GROUNDED. CLEANED FWD CABIN TEMPERATURE SENSOR REF AMM TASK 21-61-10-100-801; ACCOMPLISHED BITE CHECK OF BOTH TEMP CONTROLLERS. NO FAULTS REF 21-61-00-700-806-002; RAN AIR CONDITIONING SYS WMar 23, 2015 · N435AS · Boeing 737990ERSDR ASAA2015031510965Warning Light · false activationDURING MASTER RECALL, "ZONE TEMP" LIGHT ILLUMINATED ON OVERHEAD PANEL, AT CONTROLLER CABIN LIGHT EXTINGUISHED WITH MASTER CAUTION RESET. AIR CONDITION SYS OPERATES NORMAL. ACFT GROUNDED. ACCOMPLISHED ZONE TEMP CONTROLLER BITE IAW FIM 21-62-801, NR 2 CONTROLMar 15, 2015 · N564AS · Boeing 737890SDR ASAA2015030910897Valve · malfunctionedCONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATED UPON RECALL, EXTINGUISHES UPON MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED TEMP CONTROLLER BITE, NR 1 AND NR 2 TEMP CONTROLLERS BOTH SHOW FLT DECK TRIM VALVE FAULTS ON BITE AND PREVIOUS FLTS. REPLACED CONTROLLMar 9, 2015 · N518AS · Boeing 737890SDR ASAA2015030910896Warning Light · false activationAFTER ENGINE START ZONE TEMP LIGHT ILLUMINATED FWD CAB. ACFT GROUNDED. PERFORMED BITE TEST OF NR 1 & NR 2 TEMP CONTROLLER, CLEARED FAULT- NO DEFECTS NOTED. ZONE TEMP LT EXTINGUISHED.Mar 9, 2015 · N516AS · Boeing 737890SDR ASAA2015030210830Valve · malfunctionedCONTROL CABIN ZONE TEMP LIGHT COMES ON DURING RECALL WITH MASTER CAUTION LIGHT. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROLLER BITE TEST, NR 2 CONTROLLER INDICATES FLT DECK TRIM VALVE FAULT, REF MM 21-61-00-700-806-002. REPLACED FLT DECK TRIM Mar 2, 2015 · N536AS · Boeing 737890
Back to JASC 2160