Service difficulty reports · 3,041

Reports filed under 2160 · Cabin Temperature Control System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2160'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASAA12511675Filter · dirtyFWD CABIN ZONE TEMP CAUTION LIGHT INOPERATIVE. RELAMPED TWICE WITH NO CHANGE, BOTH BULBS. CIRCUIT BREAKER COMFIRMED IN. CLEANED CABIN FWD TEMP FILTER REF AMM 21-61-06-100-801, SYS OPS NORMAL.Jun 10, 2012 · N538AS · Boeing 737890SDR ASAA2012060992331Control Valve · faultyCONT CAB ZONE TEMP ILLUMINATED ON RECALL. LIGHT EXTINGUISHED ON RESET. ACFT GROUNDED. BITE TEST SHOWS ON NR 2 AUTOTEMP CONTROLLER LOGGED FLT DECK TCV FAULT. R & R FLT DECK TCV (V143) DUE TO HISTORY, REF AMM TASK 21-61-21, OPS CK NORMAL.Jun 9, 2012 · N589AS · Boeing 737890SDR ASAA2012062792433Warning Light · false activationAFTER START CHECKLIST, RECALL CONT CAB ZONE TEMP ILLUMINATED ON RECALL & EXTINGUISHED ON CLEARING MASTER CAUTION. NR 2 CONTROLLER SHOWS FLT DECK TRIM VALVE FAULT ON PREVIOUS FLT, VERIFY TEST PASS. RESET FAULT. FAULT DID NOT RETURN. BITE TEST NR 2 TEMP CONTJun 2, 2012 · N516AS · Boeing 737890SDR ASAA2012061892368Control Valve · failedLEFT PACK LIGHT ILLUMINATES UPON RECALL. LIGHT RESETS UPON CANCELLING / PUSH TO RESET. MASTER CAUTION. ACFT GROUNDED. REPLACED TEMP CONTROL VALVE IAW AMM 21-51-10-400-801.Jun 1, 2012 · N570AS · Boeing 737890SDR ASAA2012061892366Control Valve · failedON PUSHBACK RECALL GETTING LT PACK LIGHT ON WITH MASTER CAUTION LIGHT ILLUMINATED, PUSHING MASTER CAUTION EXTINGUISHES PACK LIGHT. ACFT GROUNDED. R & R LT TEMP CONT VALVE. REF AMM TASK 21-51-10-000-801 & LK, OPS CHECKED GOOD.Jun 1, 2012 · N559AS · Boeing 737890SDR ASAA2012061592348Warning Light · false activationZONE TEMP LIGHT ILLUMINATED MASTER CAUTION RESETS LIGHT, PRESS RECALL & LIGHT ILLUMINATES. ACFT GROUNDED. PERFORMED PACK ZONE TEMP CONTROLLER BITE CHECK IAW AMM 21-61-00-700-806-002. OPS CHECKED GOOD. DID NOT DUPLICATE ORIGINAL DISCREPANCY AND FOUND NO MAIJun 1, 2012 · N513AS · Boeing 737890SDR ASAA2012061492347Warning Light · illuminatedLEFT PACK TRIP LIGHT CAME ON. RESET, BUT MASTER CAUTION ON RECALL. ACFT GROUNDED. FOUND LEFT PACK TEMP CONTROLLER TO HAVE THIS PACK TCV FAULT. PERFORMED BITE ON TEMP CONTROLLER- FAULT CLEARED. INTERMITTENT FAULT OK FOR SERVICE. REF FIM 21-62-00-810-830.Jun 1, 2012 · N517AS · Boeing 737890SDR ASAA12511603Warning Light · illuminatedON RECALL THE CONT CABIN ZONE TEMP LIGHT ILLUMINATES. ACFT GROUNDED. NR 2 TEMP CONT LOGGED, CONT CABIN TRIM AIR FAULT LAST FLT. PERFORMED FIM 21-62 TASK 842 & FAULT RESET BITE CHECK PASSED & GROUND FUNCTIONAL TEST PASSED IAW SAME.May 28, 2012 · N570AS · Boeing 737890SDR ANCF2012052500123Filter · defectiveDURING CLIMB THE COCKPIT AND CABIN COMPARTMENTS TEMPERATURE WENT OUT OF CONTROL COCKPIT REACH 38°C OUTLET TEMPERATURES REACH 60°C, RESETS WERE PERFORMED, IN ACCORDANCE WITH MCC UNSUCCESFUL. IN ACCORDANCE WITH AMM TASK 21-63-00-810-821 ZONE TEMPERATURE CONTROMay 25, 2012 · N612MX · Airbus A319112SDR ASAA12511564Warning Light · false activationCONTROL CABIN "ZONE TEMP" AMBER LIGHT CAME ON DURING RECALL CHECK. LIGHT EXTINGUISHED ON RESET. ACFT GROUNDED. ACCOMPLISHED FIM 21-62T801, RT PACK ZONE TEMP CONTROLLER SHOWS "FLT DECK TRIM VALVE" FAULT. ACCOMPLISHED FIM 21-62T832 FAULT RESET.May 16, 2012 · N596AS · Boeing 737890SDR USAA2012051700001Modulating Valve · faultyAFTER BEING TOWED BACK TO GATE WITH LEFT PACK SWITCH OFF, THE LEFT PACK LIGHT CAME ON AND AIRCRAFT FILLED WITH ABNOXIOUS ODOR/DIRTY SOCK SMELL. DEPLANED AIRCRAFT. DUE TO LOW APU AIR PRESSURE ON START, TURBO FAN WAS THOUGHT TO BE STUCK ON. CLOSED FAN CONTROLMay 15, 2012 · N459UW · Boeing 7374B7SDR UIEA2012051300214Control Valve · failedLEFT PACK TEMPERATURE EICAS MESSAGE. R & R PACK TEMPERATURE CONTROL VALVE IAW AMM 21-51-12. OPS CHECKED NORMAL.May 13, 2012 · N641GT · Boeing 76738ESDR ASAA12511540Modulating Valve · faultedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL LIGHT RESET NORMALLY. CONTROLLERS BITE CHECK BAD WITH CONTROL CABIN TRIM MODULATING VALVE FAULT. ALSO SYSTEM HAD A PREVIOUS WRITE UP. R & R CONTROL CABIN ZONE TRIM AIR MODULATIING VALVE IAW AMM 21-61-21-00May 11, 2012 · N536AS · Boeing 737890SDR UALA2012051102755Valve · malfunctionedUNABLE TO CONTROL CABIN TEMP. CYCLED CB C33 PER TOMC AND REGAINED CAB TEMP CONTROL. FOUND MID TRIM MODULATING VALVES IN OPEN POSITION. AS PER DF0690 CLOSED AUX MID AND MID MODULATING VALVES.May 10, 2012 · N652UA · Boeing 767322SDR ASAA12511539Modulating Valve · failedZONE TEMP CONTROL FAULTED THE FLT DECK TRIM VALVE. ACFT GROUNDED. ACCOMPLISHED FIM 21-62-00-810-832. R & R CONTROL CABIN ZONE TRIM AIR MODULATING VALVE REF MM 21-61-21-400-801 THRU STEP F. (4) . LEAK & OPS CHECKED GOOD MM 21-61-21-400-801 COMPLETED.May 10, 2012 · N579AS · Boeing 737890SDR ASAA12511530Warning Light · illuminatedZONE TEMP LIGHT ILLUMINATES ON RECALL. WHEN RESET PUSHED LIGHT EXTINGUISHES. ACFT GROUNDED. BITE CK SHOWS NR 2 CONTROLLER FLT DECK TRIM VALVE VERIFIES GO. RESET CONTROLLER RAN PACKS & RETESTED. FAULT DOES NOT RETURN. REF AMM 21-62-00-810-801.May 9, 2012 · N516AS · Boeing 737890SDR UIEA2012050900201Control Valve · inoperativeRT PACK TEMP EICAS MESSAGE CAME ON DURING INITIAL CLIMB OUT, ACCOMPLISHED CK LIST EICAS MSG WENT OUT. R & R RT TEMP CONTROL VALVE IAW AMM 21-51-12 SYS CHECKS GOOD AT THIS TIME.May 9, 2012 · N640GT · Boeing 7673S1SDR ASAA1251528Filter · cloggedF/A REPORTS ABOUT CABIN TEMPERATURE, SUGGEST THAT "FWD CABIN" AND "AFT CABIN" CONTROL KNOBS ARE PRODUCING ERRATIC SUPPLY TEMPS THAT ARE INCONSISTENT WITH KNOB POSITION. FOR INSTANCE "FWD CAB" AT 11 O'CLOCK PRODUCES 20 DEG SUPPLY TEMP CONT FROM FLIGHT DECK DIFMay 8, 2012 · N563AS · Boeing 737890SDR CA120426010Switch · malfunctioned(CAN) DURING FLIGHT CREW WERE UNABLE TO CONTROL THE CABIN TEMPERATURE, ACM OVERTEMP WARNING RECEIVED AND AT 1 POINT THEY THOUGHT THEY COULD SMELL SOME FUMES, WITH FURTHER MANIPULATION OF CONTROLS CREW WAS ABLE TO GAIN SOME CONTROL OF TEMPERATURE. ECU TEMP SWITApr 23, 2012 · Cessna 560XLSDR UALA2012042302419Shutoff Valve · inoperativeFOUND LEFT TRIM AIR PRSOV NOT CLOSING. REMOVED LEFT TRIM AIR PRSOV REF MM. INSTALLED NEW TRIM AIR PRSOV PER MM. MAT TEST PASSED.Apr 23, 2012 · N776UA · Boeing 777222SDR UALA2012042302430Indicator · faultyCABIN TEMP INDICATOR LIGHTS VERY DIM, DIFFICULT TO READ. INDICATIONS ARE READABLE.Apr 22, 2012 · N547UA · Boeing 757222SDR AALA20120421011Heat Exchanger · crackedLAX - INFLIGHT PSP-ORD CREW REPORTED TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED AFTER TAKEOFF. EMERGENCY DECLARED FLIGHT LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND RIGHT PRIMARY HEAT EXCHANGER CRACKED. REPLACED PRIMARY AND SECOApr 21, 2012 · N974TW · Doug DC983SDR SIMA20120418005Sensor · inoperativeFLIGHT 2864, THE CREW REPORTED AFTER STARTING APU & WAITING 3 MINUTES SELECTED PACK 1 & 2 ON THEY NOTICED A BURNING ODOR THROUGHOUT AIRCRAFT. FOUND COCKPIT TEMPERATURE CONTROL INOPERATIVE. REMOVED AND REPLACED THE COCKPIT AMBIENT TEMPERATURE SENSOR IAW EMB Apr 18, 2012 · N602AE · Emb EMB145LRSDR ASAA12511408Modulating Valve · faultedDURING MASTER CAUTION RECALL AFTER START ZONE TEMP (CONT CAB) ILLUMINATED. LIGHT EXTINGUISHED ON MASTER CAUTION RESET. ACFT GROUNDED. CHECKED CABIN TEMP CONTROLLERS FOR DEFECT ISOLATION. FOUND FLT DECK TRIM MOD VALVE FAULTED. COMPLETED VERIFY TEST REF MM 21Apr 15, 2012 · N513AS · Boeing 737890SDR MYWA201204160047Controller · malfunctionedZONE TEMP LIGHTS ON FWD CAB AND AFT CAB ILLUMINATE ON RECALL. ACCOMPLISHED BITE TEST ON ZONE TEMP CONTROLLERS IAW M/M TASK 21-51-00-705-275-002 AND RESET CONTROLLERS NO FAULTS NOTED SYSTEM OPS CHECK NORMAL NO LIGHTS ILLUMINATE WHEN RECALL PUSHED.Apr 15, 2012 · N752MA · Boeing 73748ESDR ASAA12511396Warning Light · false activationCONTROL CABIN ZONE TEMPERATURE ILLUMINATED ON RECALL. ACFT GROUNDED. NR 2 TEMP CONTROLLER SHOWS "FLT DECK TRIM VALVE" FAULT. RESET. FAULT DID NOT RETURN. BITE TESTED GOOD. REF FIM 21-62/T832. FUNCTION CHECK COCKPIT TEMPERATURE CONTROL GOOD. GROUND VERIFApr 13, 2012 · N592AS · Boeing 737890SDR ASAA12511394Warning Light · false activationCONTROL CABIN ZONE TEMPERATURE LIGHT ILLUMINATED ON RECALL. GOES OUT WHEN MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED PACK ZONE TEMPERATURE CONTROL BITE 21-62-00-810-801. CLEARED FAULT, DOES NOT COME BACK ON RECALL. OPS CHECKED GOOD.Apr 13, 2012 · N579AS · Boeing 737890SDR MYWA201204160046Sensor · malfunctionedFWD & AFT CABIN TEMPS CAN NOT BE EASILY CONTROLLED WITH CABIN TEMP CONTROL SYSTEM. SMALL TEMP CORRECTIONS CAUSE LARGE TEMPERATURE SWINGS HOT TO COLD, OR COLD TO HOT. REMOVED AND REPLACED AFT CABIN TEMP BULB IAW AMM 21-62-25. TEMP SELECTORS ON ALL THREE CABIApr 13, 2012 · N752MA · Boeing 73748ESDR ASAA12511393Valve · malfunctionedUPON MASTER RECALL THE CONT CABIN ZONE TEMP LIGHT ILLUMINATED AND EXTINGUISHED WHEN MASTER CAUTION SYSTEM IS RESET AS PER THE QRH. REMOVED & REPLACED CONT CABIN ZONE TEMP VLV REF MM 21 61 21 OPS & LEAK CHECK GOOD.Apr 12, 2012 · N559AS · Boeing 737890SDR MYWA201204130042Modulating Valve · failedCANNOT CONTROL CABIN TEMP ON CLIMB WITH BOTH FWD & AFT CONTROLS IN FULL HOT, SUPPLY DUCT SHOWED 14 + 17C RESPECTIVELY. CABIN VERY COLD. TROUBLESHOT CONTROL CABIN TEMP SYSTEM IAW MM 21-61-00 AND FOUND TRIM AIR MODULATING VALVE AT FAULT. REMOVED AND REPLACED Apr 10, 2012 · N752MA · Boeing 73748ESDR ASAA12511379Warning Light · false activationAFTER START CONT CABIN ZONE TEMP ILLUMINATED WITH MASTER CAUTION, RECALL LIGHT EXTINGUISHED WITH MASTER CAUTION RESET TEMP CONTROL OPS NORMAL. RAN SYSTEM TEST PER MM 21-61-00. RESET SYSTEM SYSTEM OP CHECKED GOOD. NO FAULTS NOTED AT THIS TIME.Apr 10, 2012 · N536AS · Boeing 737890SDR ASAA12511304Filter · dirtyCONT CAB ZONE TEMP LIGHT ILLUMINATED ON RECALL LIGHT WENT OUT WITH MASTER CAUTION RESET. REPLACED CONT CABIN ZONE TRIM AIR MOD VLV PER AMM 21 61 21 00 801 AND 21 6121 400 801. PERF INT EVAL OF PACK/ZONE TEMP CNTRL PER FIM 21 62 TASK 801. NR 2 CNTRL FAULTED Mar 28, 2012 · N530AS · Boeing 737890SDR UALA2012032701936Control Valve · faultyFLT DECK TEMP ISSUE, FLIGHT DIVERTED. TEMP DROPPED TO 52 DEGREES. TRIM AIR OFF-PACK STANDBY, NO HELP. REPLACED LT PACK TEMP CONTROL VALVE. AFTER RUNNING BOTH LEFT & RIGHT PACK WITH TRIM AIR OFF TEMP IN ALL ZONES STABILIZED AND WAS CONTROLLABLE. INSPECTEDMar 27, 2012 · N546UA · Boeing 757222SDR ASAA12511286Unknown · malfunctionedCONT CAB ZONE TEMP LIGHT ON MASTER CAUTION RECALL. MASTER CAUTION RESET EXTINGUISHES LIGHT. NR 2 CTRLR SHOWS FLT DECK TRIM VALVE FAULT ON PREV FLT. RESET & FAULT DID NOT RETURN BITE TEST NR 2 CTRLR GOOD. REF FIM 21 62 /T832. NO HISTORY 60 DAYS.Mar 23, 2012 · N533AS · Boeing 737890SDR ASAA12511275Modulating Valve · faultyDURING RECALL AFTER STARTING ENGINES AIR COND MASTER CAUTION LIGHT REMAIN ILLUMINATED ALONG WITH CONT CAB ZONE TEMP LIGHT. RESETS WITH MASTER CAUTION RESET. BITE CKD BOTH CONTROLLERS NR 2 CONTROLLER FAULTED FLT DECK TRIM VALVE. REPLACED R2 COCKPIT ZONE TRIMMar 18, 2012 · N512AS · Boeing 737890SDR ASAA12511252Warning System · false activationON RECALL ZONE TEMP LT CAME ON AND GOES OUT WHEN MASTER CAUTION IS PRESSED. PERFORMED FIM TASK 21 62 00 810 842 CONTROL CABIN ZONE TEMP LIGHT ON AND STAYS OFF AFTER RESET. RESET FAULT AND OPERATED PACK GROUND VERIFICATION TESTS NORMAL. NO HISTORY 60 DAYS.Mar 17, 2012 · N532AS · Boeing 737890SDR ASAA1251251Unknown · malfunctionedFLT ATTN REPORT : 6 10 PASSENGERS HOT EXTREMELY UNCOMFORTABLE MOST OF THE FLT DESPITE REPEATED ATTEMPTS FROM THE FLT DECK TO COOL IT OFF. BITE CHECKED BOTH NR 1 AND NR 2 ZONE TEMP CONTROLLERS. REF MM 21 61 00. NO FAULTS. INSPECTED PCA VENTS AT ROWS 6 10 ANMar 15, 2012 · N557AS · Boeing 737890SDR UALA2012031501718Modulating Valve · faultyCOCKPIT TEMP WILL NOT COOL BELOW 86 CABIN TEMPS ARE 74 & 69. DOES NOT OPERATE IN MANUAL OR AUTO TO COOL COCKPIT. DF'D PER MEL. REMOVED & REPLACED COCKPIT TRIM AIR MODULATING VALVE, OPS CHECK GOOD.Mar 14, 2012 · N584UA · Boeing 757222SDR UIEA2012031300091Control Valve · malfunctionedRT PACK O/H LIGHT AND EICAS CAME ON IN FLIGHT, LIGHT OUT AFTER SW PLACED IN "N". R & R TEMP CONTROL VALVE IAW AMM 21-51-12, OPS CHECKED GOOD.Mar 13, 2012 · N640GT · Boeing 76738ESDR UALA2012031401693Valve · faultyCREW REPORT: UNABLE 2 CONTROL TEMPS COCKPIT SET FULL HOT TEMP-68-FWD CABIN SET FULL COLD TEMP-74. SAMC TEXT: AFT FULL HOT TEMP-70. SECURED HOT AIR PRV CLOSED.Mar 12, 2012 · N409UA · Airbus A320232SDR ASAA12511229Unknown · malfunctionedZONE TEMP ILLUMINATED ON RECALL FOR CONT CAB. NR 2 TEMP CONT LOGGED FLT DECK TRIM AIR FAULT LAST FLT. PERFORMED FIM 21 62 TASK 842 & FAULT CLEARED. BITE CK OF BOTH CONTROLLERS PASSED & GROUND FUNCTIONAL TEST PASSED.Mar 11, 2012 · N557AS · Boeing 737890SDR ASAA12511185Fan · failedFWD CABIN TEMP SENSOR FAN FAILED. REMOVED AND REPLACED FWD CABIN TEMP SENSOR FAN PER AMM REF 21 61 11 000 801/21 61 11 000 801. OP'S CHECKS GOOD.Mar 4, 2012 · N592AS · Boeing 737890SDR SIMA20120229007Coupling · defectiveON FLIGHT 4295 PRESSURIZATION FAILED CLIMBING THROUGH 12000FT DESC TO 10000FT ATTEMPTED TO RESET PER RED ADM 1 AC WOULD NOT PRESSURIZE. THE AIRCRAFT WAS REMOVED FROM SERVICE. ON LG PAGE 3165073 REMOVED AND REPLACED COUPLING FOR DUALN TEMPERATURE CONTROL IAW Feb 29, 2012 · N817AE · Emb EMB135KLSDR CA120301004Valve · failed(CAN) WHILE ENROUTE, THE CREW WAS REPORTING A CABIN DUCT OVERHEAT AND TURNED THE SYSTEM OFF. WITH THE SYS OFF THE CREW WAS UNABLE TO MAINTAIN AN ADEQUATE TEMPERATURE IN THE CABIN OR FLIGHT DECK. THE CREW ELECTED TO DIVERT WHEN THE CABIN TEMP WAS APPROXIMATELFeb 25, 2012 · Airbus A321211SDR UALA2012022101059Valve · faultyEICAS MESSAGE FOR COCKPIT TEMP DISPLAYED AND COCKPIT TEMP INOPERATIVE LIGHT ILLUMINATED IN AUTO. MANUAL OPERATION NORM. FOUND COCKPIT TRIM AIR VALVE SLOW TO MOVE. REPLACED TRIM AIR VALVE.Feb 20, 2012 · N654UA · Boeing 767322SDR UIEA2012021900054Warning Message · false activationRIGHT PACK MX MESSAGE TEMPERTURE CONTROL VALVE ON BITE CHECK. PERFORMED FIM FIM 21-51-00, FIG 103, TABLE B TEMPERTURE CONTROL VALVE, STEP 1E CONTROL VALVE OK.Feb 19, 2012 · N640GT · Boeing 7673S1SDR UALA2012022101058Controller · inoperativeCOCKPIT AUTO TEMPERATURE CONTROL INOPERATIVE, WORKS IN MANUAL. FOUND CABIN TEMP CONTROLLER FAILED BITE. REPLACED CONTROLLER AS PER AMM. ALL OPS NORMAL, BITE TEST AND OPS CHECKED OKAY.Feb 18, 2012 · N654UA · Boeing 767322SDR ASAA12511122Control Valve · malfunctionedAFTER ENGINE START ON GROUND CONT CAB ZONE TEMP LIGHT ILLUMINATED UPON RECALL. LIGHT CANCELS WITH MASTER CAUTION RESET PER QRH PROCEDURE. PERFORMED FIM TASK 21-62-00-810-842 CONTROL CABIN ZONE TEMP LIGHT ON AND STAY OFF AFTER RESET. CONFIRMED FAULT TCV FAULFeb 17, 2012 · N597AS · Boeing 737890SDR MYWA201202160020Warning Light · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATED DURING FLIGHT DECK RECALL. PERFORMED PACK/ZONE TEMP CONTROLLER BITE PROCEDURES IAW FIM 21-62 TASK 801, NO FAULTS NOTED.Feb 16, 2012 · N734MA · Boeing 7378Q8SDR ASAA12511091Modulating Valve · faultyON RECALL THE AIR COND AND ZONE TEMP CONT CAB ILLUMINATED. RAN QRC MAINT CONT CONTACTED. BITE TESTED ZONE TEMP. CONTROLLERS AND FOUND FAULT ON NR 2 CONT FLT DECK TRIM VALVE. REPLACED THE PRIMARY FLIGHT DECK TRIM AIR MODULATING VALVE PER MM 21 61 21 000 ANFeb 12, 2012 · N535AS · Boeing 737890
Back to JASC 2160