JASC 2160
Service difficulty reports · 3,041
Reports filed under 2160 · Cabin Temperature Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA130104004Rheostat · intermittent(CAN) AFTER INSTALLING A CABIN HEATER IN THE ACFT, WE HAVE HAD ISSUES WITH THE OPERATION OF THE HEATER. WE INSTALLED A NEW LINEAR RHEOSTAT CONTROL, PN CD21399 WHICH CAME WITH THE HEATER. OVER THE LAST FEW MONTHS WE HAVE HAD 3 FAILURES OF THE UNIT. IT APPEARSDR ASAA2012122993566Controller · faultedCONT CAB ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHED WITH MASTER CAUTION RESET. PERFORMED FIM 21-62, TASK 842. BITE TEST OF NR 2 ZONE TEMP CONTROLLER HAS FAULT, FLT DECK TRIM VALVE . CLEARED FAULT AND RAN PACKS. FAULT DID NOT RETURN. INTERMITTENT FAULT IAW SDR UALA2012122107339Actuator · faultyPACK 2 ALL ZONES TEMPS VERY WARM ON DESCENT PACK 1 CURRENTLY ON DF FOR FCV. FOUND AFT CABIN TEMP SENSOR FILTER BLOCKED CLEANED BOTH MID AND AFT FILTER. PERFORMED CABIN TEMP CONTROL TEST, FAILED P2 RAM AIR OUT ACTUATOR, OPEN RIGHT PACK PANEL, CLEANED CONNECTOSDR ASAA2012122093513Modulating Valve · inoperativeF/O TEMP ZONE LIGHT ILLUMINATES ON RECALL. R & R AFT ZONE TEMP MODULATING VALVE IAW AMM 21-61-21. OPS CHECKED NORMAL.SDR ASAA2012121893480Modulating Valve · malfunctionedAFT CABIN ZONE TEMP LIGHT ON FINAL APPROACH, LIGHT EXTINGUISHED ON MASTER CAUTION RESET. REPLACED AFT CABIN TRIM AIR VALVE IAW AMM 21-61-21. PERFORMED ZONE BITE TEST OF BOTH CONTROLLERS IAW 21-61-00, ZONE TRIM FAULT LIGHT EXTINGUISHED & BOTH OPS NORMAL. AFT SDR UIEA2012121600552Control Valve · malfunctionedRT PACK TEMP CONTROL VALVE TRIPS ALERT DURING BITE TEST. REPLACED THE RT PACK TEMP CONTROL VALVE, IAW AMM 21-51-11. OPS CHECKED GOOD.SDR ASAA2012121093435Indicator · failedBACK LIGHTING FOR CABIN AIR TEMP INOPERATIVE. REPLACED CABIN TEMP INDICATOR, REF MM 21-61-32. OPS CHECK OF INDICATOR NORMAL IAW SAME.SDR ASAA2012120893425Light · malfunctionedFWD CABIN ZONE TEMP CAUTION LIGHT INOPERATIVE. COULD NOT DUPLICATE. ACCOMP FIM21-62/843. NR 1 & 2 TEMP CONTROLLER BITE, FLT, & VERIFY ALL GO, NO FAULTS LOGGED. OPERATED BOTH PACK FOR OVER A HOUR ZONE TEMP LT DID NOT COME BACK. GROUND VERIFICATION OF FWD ZONSDR UALA2012120707100Valve · out of adjustFWD CABIN TEMP CONTROL SEEMS OUT OF ADJUSTMENT. LARGE DUCT TEMP VARIATIONS TOUGH TO CONTROL. SECURED IN OPENED. REPLACE TRIM PRESSURE REG FILTERS AND REPLACE TRIM VALVE AIR FWD CABIN 12HK PER MM.SDR UALA2012120306904Modulating Valve · faultyCOCKPIT COLD. COCKPIT TRIM AIR VALVE IND SHOWS FULL HOT AND COLD AIR IS BLOWING INTO COCKPIT. REMOVED AND REPLACED FLT DECK TRIM AIR MODULATING VALVE, OPS CHECK GOOD.SDR UALA2012113006879Regulator Valve · faultyDIFFICULT TO CONTROL CABIN AND COCKPIT TEMPS, HAD TO SWITCH BETWEEN AUTO AND TRIM AIR OFF. REPLACED TRIM AIR REG VALVE. BECAUSE NO FAULTS WERE FOUND, REMOVED BOTH TRIM AIR CHECK VALVES, FOUND OK AND INSTALL PROPER, ALSO CHECKED SENSE LINE ON TRIM AIR REG VALSDR UALA2012112806841Valve · faultyHOT AIR FAULTS. REFERENCE REPEAT HOT AIR FAULTS TSM 21-63-00-810-849A PLEASE REPLACE THE TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE AS PROBLEM IS INTERMITTENT. VALVE PCN 644-0100 SEALS, PCN 751-0089 2EA IPC 21-63-03-05-070A AND ITEM 90 SEE AMM 21-63-19-4SDR ASAA2012112793377Warning Light · false activationZONE TEMP LIGHT CONTROL CABIN. EXTINGUISHES WITH MASTER CAUTION. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST IAW MM 21-61-00-700-806 HAD FLT DECK TRIM VALVE LIGHT ON DURING BITE AND PREV FLT TEST GOT GO LIGHT DURING VERIFY TEST RAN TEST SEVERAL TIMES MORE SDR HNAA2012112601072Sensor · failedSTRONG ODOR IN AFT CABIN WITH ENGINE BLEEDS ON. RETURN TO GATE FOUND AUTO TEMP TO BE INOPERATIVE. MANUAL CONTROL OPS NORMAL. R & R CABIN ZONE TEMP SENSOR IAW MM 21-60-44. OPS CHECKED GOOD. NO ODOR.SDR ASAA2012112593368Warning Light · false activationON MASTER CAUTION RECALL, CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. FLIGHT DECK TRIM VALVE FAULT ON PRIMARY CONTROLLER. ACCOMPLISHED ZONE TEMP CONTROLLER BITE WITH NO CURRENT FAULTS REF FIM 21-61-801.SDR ASAA2012112393364Modulating Valve · malfunctionedCONTROL CABIN ZONE TEMP ILLUM DURING RECALL AFTER START- EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. R & R ZONE TRIM AIR MODULATING VALVE. REF AMM 21-61-21. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE CK. NO FAULTS NOTED. LK CKD GOOD.SDR SIMA20121123009Unknown · malfunctionedON FLIGHT 4389 THE CREW REPORTED THE NR 1 PACK WAS UNABLE TO CONTROL BECAUSE IT WOULD GO FULL HOT TO FULL COLD AIR WITH HUMID SMELL. THE AIRCRAFT WAS REMOVED FROM SERVICE. PERFORMED OPERATIONAL TEST OF BOTH PACK 1 AND PACK 2 IAW EMB 140 AMM 21-60-00. THE OPSDR IXXA20121121031OValve · stuckACFT RETURNED TO DEPARTURE, DUE TO NO HEAT IN THE PASSENGER COMPARTMENT. TROUBLESHOT AND FOUND NASI MIX VALVE STUCK IN THE FULL COLD POSITION. R & R MIX VALVE IAW MM 21.04.25. OPS CHECKED GOOD.SDR ASAA2012111993322Warning Light · illuminatedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL, LIGHT RESETS NORMALLY. NR 2 CONTROLLER LOGGED FLT DECK TRIM VALVE FAULT. NO HISTORY-FAULT RESET. RAN PACK-TEMP CONTROL NORMAL. NO CURRENT FAULTS, GROUND VERIFICATION SUCCESSFUL REF FIM 21-62, TASK 842.SDR UALA2012112006695Unknown · malfunctionedREPEAT GRIPE. COCKPIT COLD. WHEN COCKPIT WARMED FIRST CLASS AND FWD CABIN GETS HOT. PERFORMED TIS MANUAL 21-6 3-00-810-815-A TEST WAS OK. INSPECTED VISIBLE DUCTING IN LOWER ACCESS COMP. NO DEFECTS NOTED.SDR UALA2012111406564Valve · faultyFORWARD CABIN TEMP EICAS MSG SAMC TEXT: SEE PREVIOUS HISTORY, ZONE TEMP CTLR AND AUX ZONE TEMP CTLR PREVIOUSLY REPLACED. SUGGEST REPLACE FWD CABIN ZONE TEMP CTL VALVE. CREW (938-13) REFUSAL WITH MEL 2161YH. REPLACED FWD TRIM AIR VALVE AMM. REPLACED FWD CABSDR ASAA2012111493299Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. LIGHT RESETS NORMALLY. ZONE TEMP CONTROLLER NR 2 WITH FLT DECK TRIM VALVE FAULT. RESET AND BOTH ZONE TEMP CONTROLLERS BITE TEST NORMAL IAW FIM 21-61, TASK 801.SDR 2012FA0000702Control Valve · failedCREW REPORTED EXCESSIVE HEAT IN COCKPIT AIR SUPPLY AND HAD NO CONTROL IN AUTOMATIC OR MANUAL MODE OF TEMPERATURE CONTROL SYSTEM. DURING INVESTIGATION OF THE DISCREPANCY THE COCKPIT TEMP CONTROL VALVE WAS FOUND TO HAVE MECHANICALLY FAILED IN THE FULL HOT POSITSDR ASAA2012101093105Indicator · erraticAIR TEMP NEEDLE SHOWING ERRATIC INDICATIONS WITH SWITCH IN ALL DIFFERENT POSITIONS. REPLACED P5-17 TEMP. CONTROL MODULE AND CABIN TEMP CONTROL INDICATOR. REF TASK 21-61-15-400-801 AND TASK 21-61-32-400-801. TEMP CONTROL INDICATION OPS NORMAL, REF TASK 21-61-SDR UALA2012101005758Control Valve · faultyCABIN TEMP CONTROL TEST FAULTS. NEW VALVE INSTALLED, OPS AND LEAK CHECKED GOOD.SDR ASAA2012100493016Warning Light · false activationON RECALL, LT PACK LIGHT ILLUMINATED. BITE SHOWS TEMP CONTROL VALVE FAULT ON NR 1 ZONE TEMP CONTROLLER. RAN BITE REF AMM 2-61-00, FAULT CLEARS AND OPS NORMAL.SDR ASAA2012100493015Warning Light · false activationAFTER START, CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. ON RECALL, LIGHT EXTINGUISHED ON RESET. QRH PROCEDURE RUN WITH NO EFFECT. NR 2 ZONE TEMP CONTROLLER LOGGED FLT DECK TRIM AIR VALVE - BITE TESTED GOOD. FAULT RESET.SDR UALA2012092905533Valve · faultyCABIN TEMP STILL HARD TO CONTROL, HAD TO GO TRIM OFF. THEN OK. ZONE TEMP CNTR FAILED FORWARD TRIM VALVE. REPLACED VALVE, OPS CHECK GOOD.SDR SIMA20120925006Coupling · blownON FLIGHT 4060 THE CREW REPORTED THAT THE PACK 2 VALVE CLOSED ON EICAS. THE CREW RESET PER AOM, PACK 2 VALVE RESET THEN CLOSED AGAIN (PACK 2 VALVE CLOSED). THIS WAS FOLLOWED BY A BURNING ODOR IN THE COCKPIT, WHICH CLEARED AFTER 3 MINUTES. THE AIRCRAFT WAS RSDR SWIA201231844Control Valve · defectiveFLIGHT ATTENDANT SMELLED A PACK BURNING IN CABIN DURING FLIGHT. ON THE GROUND FLIGHT DECK BECAME SMOKEY WITH PACKS ON. (FLT 6238) REPLACED TEMP CONTROL VALVE IN REFERENCE TO EMB 120 MM. P/N: 979990-1 S/N OFF: 2081SDR UALA2012091305173Unknown · malfunctionedMID CABIN AUTO CONTROL INOPERATIVE.SDR YENA20120909597Sensor · failedFLT 805 JFK-PLS, CREW DECLARED EMERGENCY AND AIRCRAFT RETURN TO JFK DUE TO AIR PACK 1 & 2 FAULT MESSAGE. PACK 2 TEMP AT 230 C. REMOVED AND REPLACED 35HH TEMP SENSOR IAW AMM 21-61-12. OPS CHECK GOOD.SDR UALA2012091005085Condenser · crackedCOCKPIT AIRFLOW GETS SLOW DURING CLIMBOUT AND CRUISE. COCKPIT HOT AND UNABLE TO COOL. PERFORMED VISUAL INSPECTION OF LEFT PACK - FOUND 3 INCH CRACK IN LOWER FORWARD WELD OF THE LEFT CONDENSER. REPLACED LEFT CONDENSER (10HM2) REF AIRBUS A320 AMM. LEFT PACK SDR ASAA2012091892907Warning Light · false activationZONE TEMP LIGHT ACTIVATES ON RECALL EXT WITH MC RESET. TEMP CONT 2 LOGGED FLT DECK TRIM VALVE - SYS BITE TEST GOOD. FAULT RESET.SDR ASAA2012090192800Controller · malfunctionedON MASTER CAUTION RECALL ON LANDING CHECKLIST AFT CAB ZONE TEMP LIGHT, CONT CAB ZONE TEMP LIGHT AND PACK TRIP LIGHT ILLUMINATED, EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. NR 1 PACK ZONE TEMP CONTROLLER HAD A FAULT LT ON CONTROLLER. REF MM 21-6SDR YYFA20120830001Unknown · unknownUNABLE TO CONTROL CABIN TEMP SUPPLY DUCT TEMP SUPPLY DUCT TEMP WOULD NOT GO BELOW 8 DEG F. F/A'S REPORT THAT AFT CABIN IS VERY HOT, MID A BIT COOLER. FOUND THAT AN INCREASE IN POWER CAUSES A MOMENTARY COOLING. ONCE NORMAL CRUISE WAS ESTABLISHED TEMP WOUD GOSDR UALA2012083004887Shutoff Valve · failedTRIM AIR PRSOV R RIGHT TRIM AIR PRESSURE RELIEF SHUTOFF VALVE (PRSOV) FAILED. STATUS MSG-2124202 INACTV TA MODE. REPLACED TRIM AIR PRSOV RIGHT PER MM. OPERATIONAL TEST PASSED, NO ASSOCIATED MESSAGES.SDR UALA2012082904854Unknown · malfunctionedCOCKPIT TEMP ALMOST IMPOSSIBLE TO KEEP IN COMFORT RANGE. EITHER TOO HOT OR TOO COLD. FLT CREW REPORTS WITH TRIM AIR SYSTEM OFF & PACK SYSTEM IN AUTO PACK IS CONTROLLABLE. TRIM AIR DEF PROBABLE CAUSE. BITE OF ZONE TEMP CONTROLLER FOUND NO FAULTS. RE-ESTABLSDR 9JLA2012082804512Control Valve · defectiveTHE CREW REPORTED THAT THE FLIGHTDECK TEMP COULD NOT BE CONTROLLED IN FLIGHT. TROUBLESHOOTING IDENTIFIED THE RT TEMP CONTROL VALVE AS DEFECTIVE, PN 27241287-14. THE DEFECTIVE VALVE WAS REMOVED AND AN OVERHAULED UNIT WAS INSTALLED.SDR UALA2012082304715Bypass Valve · faultyCOCKPIT TEMP HARD TO CONTROL. PACK 2 PRODUCES COOLER AIR THAN PACK 1.36 DEGREES VS 64 DEGREE. REPLACED TURBINE BYPASS VALVE AND ANTI ICE ICE VALVE. PACK OPERATION GOOD.SDR UALA2012082004642Shutoff Valve · failedTRIM AIR PRSOV L LEFT TRIM AIR PRESSURE RELIEF SHUT OFF VALVE (PRSOV) FAILED. STATUS MSG-2124201 ACTIVE CL MODE MSG-2124201 ACTIVE CL MODE. REPLACED TRIM PRSOV PER MM, OPS GOOD.SDR UALA2012081004343Valve · faultyZONE C TEMP CONTROL TARGET TEMP BLANK AT C ACCOMPLISHED AND ZONE C TRIM AIR VALVE FAILED ON GROUND TEST PRIOR SUSPECT ZONE TRIM MODULATING VALVE.SDR UALA2012081304382Valve · faultedAIR SYNOPTIC, TARGET TEMPERATURE INDICATION IS BLANK CREW COMMENTS, AIR COND RESET WILL BRING BACK INDICATION BUT THEN ALWAYS BLANKS AGAIN MAT FAULTED ZONE TRIM MOD VALVE FOR ZONE C MSG. 21-2004 RENDERED ZONE C TRIM MOD VALVE INOP PER MEL 21590.SDR ASAA2012082492772Selector · malfunctionedAIR TEMP SELECT KNOB INTERMITTENT WHEN SELECTING FWD SUPPLY DUCT. CAUSES UNRELIABLE TEMP INDICATION. ACFT GROUNDED. COULD NOT DUPLICATE - OPS NORMAL.SDR ASAA2012082392769Valve · faultedON RECALL, MASTER CAUTION AIR CONDITIONING AND CONTROL CABIN ZONE TEMP LIGHTS ILLUMINATE. ALL LIGHTS EXTINGUISH UPON PUSHING MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED FIM TASK 21-62-00-810-833 CONTROL CABIN TRIM AIR VALVE (BACKUP) FAULT ISOLATION, LOGGSDR CA120730003Mixing Valve · failed(CAN) FLIGHT CREW REPORT, AFTER DEPARTING AND AFTER COMPLETING THE TAKEOFF CHECKS F/O NOTICED THE CABIN TEMP RISING RAPIDLY AND WAS UNSUCCESSFUL TO CONTROL THE HEAT ENTERING THE COCKPIT AND CABIN. F/O TRIED TURNING THE HEAT SWITCH TO COLD, AND TURN THE TEMPERSDR UALA2012071903937Control Box · failedCIRCUIT BREAKER TRIPPED REAR PANELS. V SHOWING ON LOWER ECAM. AMBER XX'S SHOWN ON ZONE CONTROL. REMOVED, INSPECTED, AND INSTALLED ZONE TEMP CONTROL BOX. VERIFIED GOOD DUCT TEMP.SDR UALA2012071803913Valve · faultyCOND HOT AIR FAULT. INSTALLED NEW PRESSURE REGULATING VALVE PER MM. RAN PACKS, NO LEAKS OR MSG NOTED.SDR UALA2012071803907Valve · faultedHARD TO CONTROL COCKPIT, FWD CABIN, AND AFT CABIN TEMP. TROUBLESHOT PER FIM 21-60-00 PG130. REPLACED TRIM AIR MODULATOR VALVE PER MM 21-61-07.SDR QXEA2012061800466B-Nut · looseDIVERSION AT 24,000 FT, PACK TEMPS WERE UNABLE TO BE CONTROLLED. TEMP INDICATED NEAR 0C FOR OUTPUT. ATTEMPTED PACK RESETS, NO CHANGE. ATTEMPTED F/A CONTROL OF CABIN PACK, NO CHANGE. DESCENDED TO 20000 FT, NO HELP. ATTEMPTED AUTO AND MANUAL MODES, NO CHANGE.
Back to JASC 2160