JASC 2160

Service difficulty reports · 3,040

Reports filed under 2160 · Cabin Temperature Control System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2160'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASAA2022100240157Modulating Valve · faultyCON CAB ZONE TEMP ON RECALL. GROUNDED - YES. CONFIRMED FAULT, CONT CAB ZONE TEMP LIGHT ILLUMINATES ON RECALL. NO. 2 PACK/ZONE TEMP CONTROLLER SHOWS HARD FAIL "FLIGHT DECK TCV" (V143). REMOVED & REPLACED TCV REF B737-900 AMM 21-61-21, GROUND FUNCTIONAL CK & LK Oct 2, 2022 · N459AS · Boeing 737990ERSDR ABXA202209298100Controller · faultedCABIN TEMP CONTROLLERS INDICATED INOP ON EICAS FOR "FWD" , "AFT", AND "FLT DK" ON OVHD PANEL. AIRCRAFT BACK TO BLOCK AND GROUNDED BY MAINTENANCE. MAINTENANCE RESET CABIN TEMP ZONE CONTROLLER REF AMM 21-61-00 OPS CHECK OK. AIRCRAFT RETURNED TO SERVICE.Sep 28, 2022 · N219CY · Boeing 767383SDR NACA2022092500001Warning Message · illuminatedEICAS MSG: AFT CABIN TEMP. AFT CABIN TEMP EICAS MSG DEFERRED PER MEL 21-61-01-02 CAT C @ 0350Z, AC REMAINS ETOPS 180.Sep 25, 2022 · N321CM · Boeing 767323SDR ASAA2022092540080Modulating Valve · faultyCONTROL CABIN ZONE TEMP ILLUMINATED EXTINGUISHES W/ MASTER CAUTION RESET. GROUNDED - YES. REMOVED AND REPLACED CONTROL CABIN TRIM MODULATING VALVE IAW B737-800 AMM 21-61-21-000-801 AND AMM 21-61-21-000-801.Sep 25, 2022 · N513AS · Boeing 737890SDR ASAA2022092240045Control Valve · faultyCONT CABIN LIGHT ILLUMINATES DURING RECALL. GROUNDED - YES. REPLACED CONTROL CABIN TAV REF B737-800 AMM 21-61-21.Sep 22, 2022 · N516AS · Boeing 737890SDR ASAA2022091839970Modulating Valve · fault messageAFTER ENGINE START, UPON MASTER CAUTION RECALL, WE GOT "ZONE TEMP" LIGHT ON CONTROL CABIN. GOES AWAY ON RESET. GROUNDED - YES. RELEASED PER ASA MEL 21-21G FLIGHT DECK PRIMARY TEMPERATURE CONTROL INOP. ENROUTE MEL - #2 ZONE TEMP CONT LOGGED 'FLT DECK TRIM VALVESep 18, 2022 · N461AS · Boeing 737990ERSDR ASAA2022090639868None · faultyRIGHT PACK LIGHT ON RECALL DURING AFTER START CHECKLIST. GROUNDED - YES. REMOVED AND REPLACED TCV V141 REF B737-900 AMM 21-51-10.Sep 6, 2022 · N413AS · Boeing 737990ERSDR ASAA2022090539816Controller · unknownCONT CAB TEMP CABIN LIGHT ILLUMINATED ON RECALL AND EXTINGUISHED ON RESET. GROUNDED - YES. PERFORMED PZTC BITE IAW B737-800 FIM 21-62 TASK 801. #2 CONTROLLER HAD FLT DECK TRIM VALVE ON BITE, CLEARED GREEN ON VERIFY. PER FIM 21-53 TASK 821, NO FURTHER ACTION RESep 5, 2022 · N562AS · Boeing 737890SDR ASAA2022082939700Valve · faultyAFTER T/O CONT CAB ZONE TEMP LITE ILLUMINATED. RAN QRH AND ZONE TEMP LITE EXTINGUISHED. GROUNDED - YES. PER B737-900 FIM 21-62 TASK 801. PERFORMED BITE OF PZTC. CONTROLLER 2 HAD FLT DECK TRIM VALVE FAULT IN HISTORY. PERFORMED VERIFY A COUPLE TIMES. EACH TIME PAug 29, 2022 · N440AS · Boeing 737990ERSDR ASAA2022082639669Unknown · faultyAT THE GATE THE RIGHT PACK LIGHT ILLUMINATED. TEMPERATURE INDICATOR FOR R PACK WAS PEGGED HIGH. GROUNDED - YES. RIGHT PACK HAD TRIPPED OFF, ZONE TEMP CONT LOGGED TCV. RESET PACK, RAN FOR SEVERAL MINUTES - OPS CKS GOOD. ZONE TEMP BITE CKS GOOD REF B737-800 AMAug 26, 2022 · N581AS · Boeing 737SDR ASAA2022082439635Unknown · unknownCONT CAB ZONE TEMP ILLUMINATED ON RECALL, EXTINGUISHED ON RESET. GROUNDED - YES. PERFORMED B737-800 FIM 21-62 TASK 842 AND BITE IAW FIM 21-62 TASK 801. NO FAULTS IN HISTORY OR CURRENT AND VERIFY PASSES. PER INITIAL EVALUATION AULT WAS INTERMITTENT. FAULT NO LOAug 24, 2022 · N577AS · Boeing 737SDR ASAA2022080739382Regulator Valve · inoperativeCONT CAB UNABLE TO CONTROL TEMPERATURE WAS TOO COLD AT ALL PHASES OF FLIGHT EVEN AT W SETTING. GROUNDED - YES. REMOVED AND REPLACED TRIM AIR REGULATING AND S/O VALVE REF B737-900 AMM 21-62-01.Aug 7, 2022 · N459AS · Boeing 737990ERSDR ASAA2022080539448Valve · faultyRT PACK LIGHT ILLUMINATES ON RECALL RESETS ON MASTER CAUTION RESET. GROUNDED - YES. RMVD & RPLCD FWD PASS CABIN TRIM VALVE REF B737-800 AMM 21-61-21.Aug 5, 2022 · N577AS · Boeing 737890SDR ASAA2022080539381Modulating Valve · faultyLEFT PACK LIGHT ILLUMINATED ON RECALL EXTINGUISHES ON MASTER CAUTION RESET. GROUNDED - YES. REMOVED AND REPLACED FLIGHT DECK ZONE TRIM AIR MODULATING VALVE IAW B737-800 AMM 21-61-21.Aug 5, 2022 · N592AS · Boeing 737890SDR ASAA2022072739249Modulating Valve · faultyCONT CAB-ZONE TEMP LIGHT ILLUMINATED ON MASTER RECALL. CAUTION LIGHT RESETS UPON MASTER CAUTION RESET. (AFTER PUSH BACK). GROUNDED - YES. REMOVED & REPLACED TRIM AIR MODULATING VALVE, OPS BITE CK GOOD REF B737-800 AMM 21-61-21.Jul 27, 2022 · N594AS · Boeing 737890SDR IPXA2022072684570A/C Pack · abnormalINSPECTION TYPE:ETOP** ETOPS FILED OPEN**AFT CABIN TEMP MSG AND INOP LIGHT ILLUMINATED. DEFEND AFT CABIN TEMP CONT SYS PER MEL 21-61-1-2 DMP ACCOMPLISHED BY 0556511 AUTHORIZED BY 0557835 PLACARD INSTALLED. DI LOG UPDATED.Jul 25, 2022 · N394UP · Boeing 767381SDR ASAA2022071939123Modulating Valve · failedCONT CAB ZONE TEMP ILLUMINATES ON RECALL EXTINGUISHED ON MASTER CAUTION RESET. GROUNDED - YES. ACCOMPLISHED BITE TEST PER B737-800 AMM TASK 21-61-00-700-806-002. FOUND CONT CAB TRIM VALVE FAIL ON BITE & LAST FLT. AFTER TEST RESET AND FAULT IS GONE. OPS GOOD PEJul 19, 2022 · N593AS · Boeing 737890SDR ASAA2022071639114Modulating Valve · faultyCONTROL CABIN ZONE TEMP ILLUMINATED DURING MASTER CAUTION RECALL. RESET OK. GROUNDED - YES. PERFORMED BITE CK B737-800 AMM 21-61-00. FOUND TRIM VLV FLT DECK FAULT. RESET REPERFORMED BITE ALL PASS GO GREEN WITH NO FAULTS. NO HISTORY 30 DAYS.Jul 16, 2022 · N563AS · Boeing 737890SDR ASAA2022070938982Modulating Valve · failedCONT CAB ZONE ILLUMINATED, CLEARS WITH MASTER CAUTION. GROUNDED - YES. CONFIRMED FAULT, R/H PACK TEMP CONTROL BITE PROCEDURE REF B737-800 FIM 21-62 TASK 801 SHOWS HARD FAIL "FLIGHT DECK TCV" (V143). REMOVED & REPLACED SAME REF B737-800 AMM 21-61-21, LK CK & GRJul 9, 2022 · N588AS · Boeing 737890SDR ASAA2022070438920Modulating Valve · warning lightCONTROL CAB ZONE TEMP ILLUMINATED ON RECALL - GOES AWAY WHEN RESET. GROUNDED - YES. VERIFIED THAT THE "CONTROL CAB ZONE TEMP" LIGHT COMES ON WHEN ON RECALL. PERFORMED BITE CHECK OF THE PACK/ZONE TEMPERATURE CONTROLLER. CONTROLLER 2 SHOWS "FLT DECK TRIM VALVE" Jul 4, 2022 · N467AS · Boeing 737990ERSDR ASAA2022070338954Modulating Valve · faultyON RECALL ZONE TEMP LIGHT ILLUMINATES FOR CONT CAB LIGHT EXTINGUISHES WITH MASTER CAUTION RESET. GROUNDED - YES. CONFIRMED FAULT, R/H PACK/ZONE TEMP CONTROLLER SHOWS HARD FAIL FLIGHT DECK TCV (V143). REMOVED & REPLACED SAME REF B737-900 AMM 21-61-21. GROUND FUJul 3, 2022 · N493AS · Boeing 737990ERSDR ASAA2022070238929Modulating Valve · faultyCONT CABIN ZONE TEMP LIGHT ON MASTER RECALL. EXTINGUISHES ON MASTER CAUTION RESET. GROUNDED - YES. PER B737-900 FIM 21-62 TASK 842 PERFORMED TEMP CONTROLLER #2 BITE - FAULT ACTIVE & SHOWS FLT DECK TRIM VALVE. REMOVED & REPLACED FLT DECK TRIM VALVE REF B737-900Jul 2, 2022 · N479AS · Boeing 737990ERSDR ASAA2022070138900Modulating Valve · faultyCONT CAB ZONE TEMP LIGHT ILLUMINATES DURING RECALL. GROUNDED - YES. T/S PER B737-800 FIM 21-62 TASK 801 BITE OF PACK TEMP CONTROL AND FOUND FAULT ON RIGHT TEMP CONTROL VALVE. REPLACED RH TEMPERATURE CONTROL VALVE REF B737-800 AMM 21-51-10 OPS CHECK GOOD NO LEAJul 1, 2022 · N558AS · Boeing 737890SDR ASAA2022062938873Control Valve · faultedSITTING AT THE GATE WITH APU BLLED AND BOTH PACKS OFF, SUDDENLY GOT L PACK LIGHT ILLUMINATED, AND WOULD NOT RESET WITH MASTER CAUTION RESET. THIS PACK ALREADY HAS MEL 21-32B APPLIED. GROUNDED - YES. ACCOMPLISHED PACK TEMP CONTROL BITE TEST AND FOUND TCV FAULT.Jun 29, 2022 · N402AS · Boeing 737990ERSDR AALA202206244803Regulator Valve · inoperativeAIRCRAFT WAS GROUNDED: CONTROL CABIN TEMPERATURE WAS UNCONTROLLABLE COLD, RAN QUICK REFERENCE HANDBOOK. AIR INTERRUPTED BACK TO ORD DUE TO THIS PRESSURIZATION ISSUE. EMERGENCY WAS NOT DECLARED AND NOT OVERWEIGHT FOR LANDING. REMOVED AND REPLACED TRIM AIR PRESSJun 22, 2022 · N335RT · Boeing 737SDR ASAA2022061638702Master Caution · false indicationUPON MSTR RECALL PUSH ON AFTER START CONT CAB ZONE TEMP CAUTION LIGHT ILLUMINATED GOES OUT BUT W/ MSTR CAUTION SWITCH RESET. GROUNDED - YES. PERFORMED B737-800 FIM 21-62 TASK 842, NO FAULTS DETECTED.Jun 16, 2022 · N564AS · Boeing 737890SDR ASAA2022061338646Modulating Valve · intermittentZONE TEMP LIGHT ILLUMINATES ON RECALL GOES OUT ON RESET TEMP CONTROL IS NORMAL. GROUNDED - YES. ACCOMPLISHED PACK/ZONE BITE TEST. FLIGHT DECK TRIM VALVE LOGGED FAULT. RESET FAULT, RAN BITE TEST TWICE. OPS CHECK NORMAL PER B737-800 AMM 21-61-00-700-806-002.Jun 13, 2022 · N531AS · Boeing 737890SDR ASAA2022061338629Modulating Valve · faultyMASTER RECALL CAUSED LEFT (#1) PACK LIGHT TO ILLUMINATE PACK LIGHT EXTINGUISHES WITH RESET. GROUNDED - YES. REPLACED CABIN TRIM AIR MODULATING VALVE - B737-900 AMM 21-61-21.Jun 13, 2022 · N403AS · Boeing 737900ERSDR ASAA2022061238628Modulating Valve · faultyZONE TEMP LIGHT CONT CAB ON RECALL DURING DESCENT. GROUNDED - YES. REPLACED CABIN TRIM AIR MODULATING VALVE - B737-900 AMM 21-61-21.Jun 12, 2022 · N403AS · Boeing 737900ERSDR F3LA2022061300057Apu · odorDISCREPANCY: REFERENCE LP228413 DIRTY SOCK SMELL DECENDING THROUGH 10000 FEET FOR SJU FORWARD AND AFT F/A REPORT SMELL AND LIGHT HEADEDNESS EVENT LASTED APPROXIMATLY 5 MINUTES F/O REPORTS OIL NEAR PACK 2 INLET ON POST FLIGHT CABIN SMELL VERIFIED BY CAPT AND F/Jun 11, 2022 · N216FR · Airbus A320214SDR ASAA2022060738580Valve · faultedCONT CAB ZONE TEMP ON WITH M/C RECALL IT DOES EXTINGUISH WHEN RESET. GROUNDED - YES. RELEASED PER 21-21G FLIGHT DECK PRIMARY TEMP INOP. #2 ZONE TEMP CONT LOGGED FLT DECK TRIM VALVE FAULT, FAULT CLEARED & CKS GOOD PER B737-900 AMM 21-61-00. GND VERIFICATION SUCJun 7, 2022 · N493AS · Boeing 737990ERSDR AALA202205311223Sensor · failedAIRCRAFT WAS GROUNDED: UNABLE TO CONTROL CABIN ZONE F TEMPERATURE 87F AT LEVEL OFF WITH SELECTOR FULL COLD 65F. FLIGHT ATTENDANT REST BUNKS EXTREMELY HOT WITH ACRID SMELL. REMOVED AND REPLACED ZONE AIR TEMPERATURE AT ZONE F PER AMM 21-61-04. OPS CHECK OK. PERFMay 28, 2022 · N724AN · Boeing 777323SDR ASAA2022051938428Modulating Valve · inoperativeFLIGHT DECK PRIMARY TEMP CONTROLLER INOP. GROUNDED - YES. REMOVE AND REPLACED TRIM MODULATING VALVE FOR CONT CABIN PER B737-800 AMM 21-61-21. OPS CHK GOOD.May 19, 2022 · N516AS · Boeing 737890SDR ASAA2022051038255A/C Pack · faultedON MASTER CAUTION RECALL RH PACK ILLUMINATED ON MASTER CAUTION RESET, RH PACK LT EXTINGUISHED. GROUNDED - YES. PERFORMED BITE TEST PER B737-800 FIM TASK 21-62 TASK 801, FOUND FAULT MESSAGE ON ZONE TEMP CONT 2 (TCV), CLEARED FAULT AND RAN PACKS ,PACKS TESTED OKMay 10, 2022 · N514AS · Boeing 737890SDR ASAA2022050838252Modulating Valve · faultyFWD CAB ZONE TEMP LIGHT ILLUMINATED ,RESETS WITH MASTER CAUTION RESET. GROUNDED - YES. REPLACED FWD PASSENGER COMPARTMENT ZONE TRIM AIR MODULATION VALVE REF B737-800 AMM 21-61-21-400-800 THROUGH SEP 3,G,4. BITE TEST GOOD. CONTINUED THROUGH STEP 5,H,3 IN REF TOMay 8, 2022 · N530AS · Boeing 737890SDR ASAA2022050538215Filter · dirtyAFTER TAXI, CONT CABIN ZONE TEMP LIGHT CAME ON, RESET WITH RECALL. GROUNDED - YES. PERFORMED B737-800 FIM 21-62 TASK 801 ON BOTH #1 AND #2 PACK ZONE/TEMP CONTROLLERS ON #2 PACK CONTROLLER FOUND FLIGHT DECK TRIM VALVE FAULT. RESET FAULT, FAULT CLEARED, REF FIM May 5, 2022 · N531AS · Boeing 737890SDR ASAA2022050438205Control Valve · faultyCONT CAB "ZONE TEMP" LIGHT ILLUMINATES ON MC RECALL. GROUNDED - YES. ACCOMPLISHED PZTC BITE REF B737-800 AMM 21-61-00-700-806-002. PREV HISTORY SHOWS FAULT FOR FLT DECK TRIM VALVE. FAULT CLEARED UPON VERIFICATION. REMOVED & REPLACED TCV FOR CONT CABIN REF AMM May 4, 2022 · N513AS · Boeing 737890SDR ASAA2022050138186Modulating Valve · faultyZONE TEMP CAUTION LIGHT ILLUMINATES DURING RECALL. GROUNDED - YES. REPLACED THE CONTROL CABIN TRIM AIR MODULATING VALVE, LEAK AND OPS CHECK GOOD REF B737-800 AMM 21-61-21/401 AND B737-800 FIM 21-62 TASK 842.May 1, 2022 · N512AS · Boeing 737890SDR ASAA2022043038165Unknown · unknownZONE TEMP 'CONT CABIN' LIGHT ILLUMINATES ON RECALL & EXTINGUISHES WITH MASTER CAUTION RESET. GROUNDED - YES. PERFORMED CABIN TEMP CONTROLLER BITE PER B737-800 FIM 21-61-00-810-801.#2 CONTROLLER LOGGED FLIGHT DECK TRIM VALVE FAULT. RESET ON "VERIFY TEST" FAULT Apr 30, 2022 · N519AS · Boeing 737SDR ASAA2022041338054Unknown · unknownCONT CAB ZONE TEMP ILLUMINATED DURING RECALL CHECK. LIGHT EXTINGUISHED AFTER MC RESET. GROUNDED - YES. INITIAL EVALUATION, CONT CAB ZONE TEMP ON MASTER RECALL AT OVERHEAD. PERFORMED PZTC IAW B737-800 FIM 21-62 TASK 801. #2 CONTROLLER HAD FLT DECK TRIM VALVE ONApr 13, 2022 · N577AS · Boeing 737SDR ASAA2022041338032Unknown · unknownCONT CABIN ZONE TEMP ANNUNCIATOR ILLUMINATES ON MASTER CAUTION RECALL. EXTINGUISHES ON MASTER CAUTION RESET. GROUNDED - YES. VERIFIED DISCREP ON MASTER CAUTION RECALL. PERFORMED PACK TEMP CONTROL-BITE PROCEDURE REF B737-800 FIM 21-62 TASK 801 ON # 2 CONTROLLERApr 13, 2022 · N516AS · Boeing 737SDR ASAA2022041338016Master Caution · failedCONT CAB ZONE TEMP ILLUMINATION DURING MASTER CAUTION RECALL. GROUNDED - YES. REMOVED AND REPLACED FLT DECK TRIM VALVE PER B737-900 AMM 21-61-21Apr 13, 2022 · N457AS · Boeing 737990ERSDR ASAA2022041037961Valve · failedCONT CAB ZONE TEMP ILLUMINATED ON MASTER CAUTION RECALL. GROUNDED - YES. PERFORMED PACK PZTC BITE PROCEDURE REF B737-900 FIM 21-62 TASK 801. FOUND BOTH PZTC 1&2 FLAGS FLIGHT DECK TRIM VALVE HARD FAILED (FIM 21-62 TASK 833). REMOVED AND REPLACED LH PACK TAV V14Apr 10, 2022 · N481AS · Boeing 737990ERSDR ASAA2022040937924None · faultyCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. RAN QRH 2.22. LIGHT OFF ON RESET AND BACK ON WITH RECALL. GROUNDED - YES. PER B737-900 FIM 21-62 TASK 842, PERFORMED PACK TEMP CONTROL BITE PROCEDURE FIM 21-62 TASK 801. FAULT CODE SHOWS FLT DECK TRIM VALVE. PER FIM 2Apr 9, 2022 · N479AS · Boeing 737900ERSDR AALA202204082199Control Valve · faultyAIRCRAFT WAS GROUNDED: DURING CLIMB CABIN TEMPERATURE UNCONTROLLABLE. SHORTLY AFTERWORD RECEIVED RIGHT WING BODY OVERHEAT. FLIGHT DIVERTED TO CLT LANDING SAFELY. REPLACED TRIM AIR PRESSURE REGULATING AND SHUT OFF VALVE PER AMM 21-62-01-000-801 AND 21-62-01-400Apr 7, 2022 · N842NN · Boeing 737823SDR ASAA2022040637919Valve · faultyCONT CAB ZONE TEMP LIGHT ILLUMINATES ON RECALL. EXTINGUISHES W/ MASTER CAUTION RESET. GROUNDED - YES. VERIFIED CONT CAB ZONE TEMP LIGHT ILLUMINATES ON RECALL. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST REF B737-900 AMM 21-61-00. FOUND FLT DECK TRIM VALVE FAApr 6, 2022 · N481AS · Boeing 737990ERSDR ASAA2022040437916Controller · faultyZONE TEMP CONT CAB ON RECALL. GROUNDED - YES. PERFORMED PACK/ZONE TEMPERATURE CONTROLLER BITE PER B737-800 FIM 21-62 TASK 801 SHOWED FLT DECK TRIM VALVE FAULT BUT VERIFY TEST DID NOT CONFIRM FAULT. PERFORMED CABIN TEMP CONTROL AND INDICATION OPS TEST PERB737-8Apr 4, 2022 · N584AS · Boeing 737890SDR ASAA2022040237865Unknown · unknownIN MASTER CAUTION RECALL AFTER ENGINE START ZONE TEMP CONT CAB ILLUMINATED ACCOMPLISHED QRH LIGHT EXTINGUISHED UPON MASTER CAUTION CANCEL. GROUNDED - YES. PACK/ZONE TEMP CONTROLLER BITE PER B737-900 FIM 21-62 TASK 801 SHOWED FAULT FOR CONTROL CABIN TRIM VALVE.Apr 2, 2022 · N483AS · Boeing 737990ERSDR ASAA2022032837816Unknown · unknownCONT CAB PRI ZONE TEMP LT. GROUNDED - YES. ACCOMPLISHED PACK/ZONE TEMP BITE TEST REF B737-900 AMM 21-61-00. BIT AND PREV FLT SHOW FLT DECK TRIM VALVE FAULT. COMPLETED VERIFY AND FAULT CLEARED. REACCOMPLISHED TEST WITH 3 GREEN PASS GO LIGHTS.Mar 28, 2022 · N467AS · Boeing 737990ERSDR ASAA2022032637781None · faultyZONE TEMP CONTROL CABIN ON RECALL AND RESETS. GROUNDED - YES. BOTH ZONE TEMP CONTLRS LOGGED FLT DECK TRIM VALVE LAST LEG BUT TEST GOOD ON GND. REMOVED AND REPLACED CONTROL CABIN TRIM VALVE IAW B737-800 AMM 21-61-21-000-801, 21-61-21-400-801 LEAK CHECK AND OPSMar 26, 2022 · N590AS · Boeing 737890
Back to JASC 2160