Service difficulty report · Modulating Valve · Boeing 737990ER

Difficulty date
July 4, 2022
Submitted
July 6, 2022
Operation
Air carrier
Aircraft
N467AS
Make and model
Boeing 737990ER
Aircraft serial
36362
Aircraft time
29,642 hours, 9,532 cycles
Part
Modulating Valve
Part number
UNKNOWN
Condition
Warning Light
Location
Unknown
Stage of operation
NR
How discovered
V
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONTROL CAB ZONE TEMP ILLUMINATED ON RECALL - GOES AWAY WHEN RESET. GROUNDED - YES. VERIFIED THAT THE "CONTROL CAB ZONE TEMP" LIGHT COMES ON WHEN ON RECALL. PERFORMED BITE CHECK OF THE PACK/ZONE TEMPERATURE CONTROLLER. CONTROLLER 2 SHOWS "FLT DECK TRIM VALVE" FAULT. ACCOMPLISHED "VERIFY" OPS CHECK AND IT CHECKS OKAY. "CONTROL CAB ZONE TEMP" LIGHT NO LONGER COMES ON WHEN ON RECALL. NO FURTHER ACTION REQUIRED PER B737-900 FIM 21-62- TASK 832.