What it covers
For reports of the indicators, lamps and associated circuitry which indicates the air temperature in the cabin.
Service difficulty reports · 69
Reports filed under 2162, newest first.
| 2000 | 2 |
|---|---|
| 2001 | 3 |
| 2002 | 1 |
| 2003 | 2 |
| 2004 | 1 |
| 2006 | 2 |
| 2008 | 1 |
| 2009 | 1 |
| 2010 | 4 |
| 2011 | 1 |
| 2012 | 8 |
| 2013 | 1 |
| 2014 | 1 |
| 2016 | 6 |
| 2017 | 1 |
| 2018 | 7 |
| 2019 | 19 |
| 2020 | 6 |
| 2021 | 1 |
| 2022 | 1 |
SDR UIEA2022011400027None · noneRH PACK HI FLOW INHIBIT .(<P>T/S FIM 21-51- TASK 875 & W/D 21-51--21</P> / <P>RH FLOW CONTROL CARD M864 FAULT </P> / <P> </P> / <P>REMOVED CLEANED UP & INSTALLED FLOW CTL CARD M864 & OPS CHECK RH A/C PACK . SYS OK PER AMM 21-51-00/808</P>)SDR UIEA2021092702125Connector · not seatedL PACK TEMP MESSAGE IN FLIGHT. COMPLIED WITH QRH. MSG BLANKED WHEN STBY N SELECTED. TRANSFERRED TO MDDR 154153 IAW MEL 21-51-03-01 CAT C DUE 06OCT21 LOGPAGE 1397874:REVERSED DDG PERF BITE ON ASM RAM AIR ACTR AND TEMP CONTROL VALVE FAULT EXAMINED AND FOUND CONSDR UIEA2020051901077Status Message · false activationCARGO AC TEMP STATUS MSG(<P>PERFORMED BITE TEST CHECK ZONE TEMPERATURE CONTROLLERS IAW AMM 21-61-03 AND SYSTEM TEST OK.</P>)